Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Automated Luminaire Design and Local Manufacturing for Highly Efficient, Customized Lighting Solutions

In response to the growing demand for tailorable and energy-efficient lighting solutions, Eaton and partners Synopsys and Rensselaer Polytechnical Institute were funded to develop an automated luminaire design method that was capable of achieving best in class efficiency while being locally manufactured at an affordable cost. This program was broken into four key technology areas, automated optics design, additively manufactured optical material characterization, printed electronics, and additively manufactured mechanical components.

99 GENERAL AND MISCELLANEOUS↗

Optical filters made from random metasurfaces using Bayesian optimization

Abstract We theoretically investigate the ability to design optical filters from a single material and a single layer of randomly dispersed resonant dielectric particles, defining a random metasurface. Using a Bayesian and generalized Mie inverse-design approach, we design particle radii distributions that give rise to longpass, shortpass, bandpass, and bandstop spectral bands in the infrared. The optical response is shown to be directly related to electric and magnetic multipole scattering of the constituent particles and their near field coupling. We discuss the effect of the particle size distribution and particle–particle coupling interactions on filter design in random systems lacking long-range order.

Materials Science↗

Mission-driven design methodology for optical systems

Disclosed are devices, systems and methods for a mission-driven design framework for optical systems. An exemplary method for improving the design of an optical system includes receive a first plurality of parameters indicative of performance requirements of the optical system, receive a second plurality of parameters representative of characteristics of one or more components in the optical system, generate a mathematical representation that combines the first plurality of parameters and the second plurality of parameters, perform a sensitivity analysis to obtain a ranking of parameters from the first plurality of parameters and the second plurality of parameters, select, based on the ranking of the parameters, at least one parameter that produces a largest change in the mathematical representation, and produce a constraint file comprising the at least one parameter for ingestion by a design tool to enable the design of the optical system.

Higbee, Shawn D.↗

Optical waveguides having flattened high order modes

A deterministic methodology is provided for designing optical fibers that support field-flattened, ring-like higher order modes. The effective and group indices of its modes can be tuned by adjusting the widths of the guide's field-flattened layers or the average index of certain groups of layers. The approach outlined here provides a path to designing fibers that simultaneously have large mode areas and large separations between the propagation constants of its modes.

47 OTHER INSTRUMENTATION↗

Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact folded metasurface spectrometer

Abstract An optical design space that can highly benefit from the recent developments in metasurfaces is the folded optics architecture where light is confined between reflective surfaces, and the wavefront is controlled at the reflective interfaces. In this manuscript, we introduce the concept of folded metasurface optics by demonstrating a compact spectrometer made from a 1-mm-thick glass slab with a volume of 7 cubic millimeters. The spectrometer has a resolution of ~1.2 nm, resolving more than 80 spectral points from 760 to 860 nm. The device is composed of three reflective dielectric metasurfaces, all fabricated in a single lithographic step on one side of a substrate, which simultaneously acts as the propagation space for light. The folded metasystem design can be applied to many optical systems, such as optical signal processors, interferometers, hyperspectral imagers, and computational optical systems, significantly reducing their sizes and increasing their mechanical robustness and potential for integration.

47 OTHER INSTRUMENTATION↗

Methods and algorithms for computer synthesis of holographic elements to obtain a complex impulse response of optical information processing systems based on modern spatial light modulators

The possibilities of designing optical devices for data processing and imaging based on the manipulation of coherent light beams by means of spatial light modulators (SLMs) are investigated. A review of commercially available SLMs is presented and the limitations of their complex modulation characteristics are analysed. The main problem of using present-day SLMs is the lack of the ability to modulate directly all states within a unit circle in the complex plane. In this regard, the characteristics of current methods for the synthesis of holographic elements are described that implement a given complex impulse response of the optical system and are optimal for using SLMs with purely amplitude, purely phase, and hybrid amplitude – phase modulation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband unidirectional visible imaging using wafer-scale nano-fabrication of multi-layer diffractive optical processors

We present a broadband and polarization-insensitive unidirectional imager that operates at the visible part of the spectrum, where image formation occurs in one direction, while in the opposite direction, it is blocked. This approach is enabled by deep learning-driven diffractive optical design with wafer-scale nano-fabrication using high-purity fused silica to ensure optical transparency and thermal stability. Our design achieves unidirectional imaging across three visible wavelengths (covering red, green, and blue parts of the spectrum), and we experimentally validated this broadband unidirectional imager by creating high-fidelity images in the forward direction and generating weak, distorted output patterns in the backward direction, in alignment with our numerical simulations. This work demonstrates wafer-scale production of diffractive optical processors, featuring 16 levels of nanoscale phase features distributed across two axially aligned diffractive layers for visible unidirectional imaging. This approach facilitates mass-scale production of ~0.5 billion nanoscale phase features per wafer, supporting high-throughput manufacturing of hundreds to thousands of multi-layer diffractive processors suitable for large apertures and parallel processing of multiple tasks. Beyond broadband unidirectional imaging in the visible spectrum, this study establishes a pathway for artificial-intelligence-enabled diffractive optics with versatile applications, signaling a new era in optical device functionality with industrial-level, massively scalable fabrication.

36 MATERIALS SCIENCE↗

Design of an achromatic and uncoupled medical gantry for radiation therapy

We are presenting the layout and the optics of a beam line to be used as a medical gantry in radiation therapy. The optical properties of the gantry's beam line are such as to make the beam line achromatic and uncoupled. These two properties make the beam spot size, which is delivered and focused by the gantry, on the tumor of the patient, independent of the angular orientation of the gantry. In this paper we present the layout of the magnetic elements of the gantry, and also present the theoretical basis for the optics design of such a gantry. A medical gantry, as it is used in the radiation treatment of cancer patients, is the last part of the beam optical system, of the accelerator complex, which delivers and focuses the beam on the tumor. The curved line shown in figure 1 is a schematic diagram of a gantry which can rotate about a horizontal axis. The particle beam (green arrow in fig. 1) enters the gantry, and is guided by the gantry on the tumor (red spot in fig. 1). As the gantry rotates about the axis shown in figure 1, the beam exiting the gantry always lies on a plane normal to the rotation axis at the point of the icocenter. Thus the gantry facilitates the ability of the beam delivery system, to deliver the beam at the tumor, which is placed at the icocenter, from any angle on this vertical plane, which is normal to the rotation angle of the gantry as stated earlier. The gantry consists of dipoles and quadrupoles elements whose median symmetry plane lies on a plane which contains the rotation axis of the gantry. In this paper we define this plane as the 'plane of the gantry'. As the beam is transported along the axis of rotation of the gantry and before it enters the gantry, it is focused by 'normal' quadrupoles and experiences no linear beam coupling. Subsequently the beam enters the gantry, and is transported by the gantry to the delivery point which is the tumor. The transported beam at the tumor is still linearly uncoupled as long as the plane of the gantry lies either, on the horizontal, or the vertical plane. In these two orientations of the gantry the dipoles and the quadrupoles are 'normal' therefore the linear R-transport-matrix appears linearly uncoupled. As the gantry rotates about this horizontal axis, to irradiate the tumor at a different angle, the linear beam coupling is unavoidable since the coordinate system of the gantry's quadrupoles is rotated with respect to the coordinate system of the quadrupoles at the entrance of the gantry which are located along the axis of rotation. As a result, in this rotated coordinate system, the beam will be linearly coupled as it is transported by the gantry to the tumor and the beam size at the location of the tumor will vary in size depending on the orientation of the gantry. In this paper we present a method which makes the beam transport R-matrix linearly uncoupled, achromatic and independent of the orientation angle of the gantry as is proven in the following section.

43 PARTICLE ACCELERATORS↗

Design of beam optics for the future circular collider e + e - collider rings

A beam optics scheme has been designed for the future circular collider- e + e - (FCC-ee). The main characteristics of the design are: beam energy 45 to 175 GeV, 100 km circumference with two interaction points (IPs) per ring, horizontal crossing angle of 30 mrad at the IP and the crab-waist scheme [P. Raimondi, D. Shatilov, and M. Zobov, arXiv:physics/0702033; P. Raimondi, M. Zobov, and D. Shatilov, in Proceedings of the 22nd Particle Accelerator Conference, PAC-2007, Albuquerque, NM (IEEE, New York, 2007), p. TUPAN037.] with local chromaticity correction. The crab-waist scheme is implemented within the local chromaticity correction system without additional sextupoles, by reducing the strength of one of the two sextupoles for vertical chromatic correction at each side of the IP. So-called “tapering” of the magnets is applied, which scales all fields of the magnets according to the local beam energy to compensate for the effect of synchrotron radiation (SR) loss along the ring. An asymmetric layout near the interaction region reduces the critical energy of SR photons on the incoming side of the IP to values below 100 keV, while matching the geometry to the beam line of the FCC proton collider (FCC-hh) [A. Chancé et al., Proceedings of IPAC’16, 9–13 May 2016, Busan, Korea, TUPMW020 (2016).] as closely as possible. Sufficient transverse/longitudinal dynamic aperture (DA) has been obtained, including major dynamical effects, to assure an adequate beam lifetime in the presence of beamstrahlung and top-up injection. In particular, a momentum acceptance larger than ±2% has been obtained, which is better than the momentum acceptance of typical collider rings by about a factor of 2. The effects of the detector solenoids including their compensation elements are taken into account as well as synchrotron radiation in all magnets. The optics presented in this study is a step toward a full conceptual design for the collider. Finally, a number of issues have been identified for further study.

43 PARTICLE ACCELERATORS↗

Plastic Laminate Antireflective Coatings for Millimeter-Wave Optics in BICEP Array

The BICEP/Keck series of experiments target the cosmic microwave background at degree-scale resolution from the South Pole. Over the next few years, the “Stage-3” BICEP Array (BA) telescope will improve the program’s frequency coverage and sensitivity to primordial B-mode polarization by an order of magnitude. The first receiver in the array, BA1, began observing at 30/40 GHz in early 2020. The next two receivers, BA2 and BA3, are currently being assembled and will map the southern sky at frequencies ranging from 95 to 150 GHz. Common to all BA receivers is a refractive, on-axis, cryogenic optical design that focuses microwave radiation onto a focal plane populated with antenna-coupled bolometers. High-performance antireflective coatings up to 760 mm in aperture are needed for each element in the optical chain, and must withstand repeated thermal cycles down to 4 K. Here, in this work, we present the design and fabrication of the 30/40 GHz anti-reflection coatings for the recently deployed BA1 receiver, with indices matched to its various polyethylene, nylon and alumina optical components. We describe an epoxy coating technique designed for alumina optics, which achieves better than 80% transmission at room temperature. For polyethylene optical elements, we present a new heat-compression approach that allows low-density polytetrafluoroethylene AR layers to reach sub-percent reflected power. We describe the planned use of these methods for the next BA cryostats, which may inform technological choices for future small-aperture telescopes of the CMB-S4 experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of the CLIC Baseline Collimation System

Important efforts have recently been dedicated to the improvement of the design of the baseline collimation system of the Compact Linear Collider (CLIC). Different aspects of the design have been optimized: the transverse collimation depths have been recalculated in order to reduce the collimator wakefield effects while maintaining a good efficiency in cleaning the undesired beam halo; the geometric design of the spoilers have also been reviewed to minimize wakefields; in addition, the optics design have been polished to improve the collimation efficiency. This paper describes the current status of the CLIC collimation system after this optimization.

43 PARTICLE ACCELERATORS↗

Hybrid optical-thermal devices and materials for light manipulation and radiative cooling

In this work, we report on optical design and applications of hybrid meso-scale devices and materials that combine optical and thermal management functionalities owing to their tailored resonant interaction with light in visible and infrared frequency bands. We outline a general approach to designing such materials, and discuss two specific applications in detail. One example is a hybrid optical-thermal antenna with sub-wavelength light focusing, which simultaneously enables intensity enhancement at the operating wavelength in the visible and reduction of the operating temperature. The enhancement is achieved via light recycling in the form of whispering-gallery modes trapped in an optical microcavity, while cooling functionality is realized via a combination of reduced optical absorption and radiative cooling. The other example is a fabric that is opaque in the visible range yet highly transparent in the infrared, which allows the human body to efficiently shed energy in the form of thermal emission. Such fabrics can find numerous applications for personal thermal management and for buildings energy efficiency improvement.

36 MATERIALS SCIENCE↗

Non-descanned multifocal multiphoton microscopy with a multianode photomultiplier tube

Multifocal multiphoton microscopy (MMM) improves imaging speed over a point scanning approach by parallelizing the excitation process. Early versions of MMM relied on imaging detectors to record emission signals from multiple foci simultaneously. For many turbid biological specimens, the scattering of emission photons results in blurred images and degrades the signal-to-noise ratio (SNR). We have recently demonstrated that a multianode photomultiplier tube (MAPMT) placed in a descanned configuration can effectively collect scattered emission photons from each focus into their corresponding anodes significantly improving image SNR for highly scattering specimens. Unfortunately, a descanned MMM has a longer detection path resulting in substantial emission photon loss. Optical design constraints in a descanned geometry further results in significant optical aberrations especially for large field-of-view (FOV), high NA objectives. Here, we introduce a non-descanned MMM based on MAPMT that substantially overcomes most of these drawbacks. We show that we improve signal efficiency up to fourfold with limited image SNR degradation due to scattered emission photons. The excitation foci can also be spaced wider to cover the full FOV of the objective with minimal aberrations. The performance of this system is demonstrated by imaging interneuron morphological structures deep in the brains of living mice.

36 MATERIALS SCIENCE↗

Optics and Systems Design of the Ring-to-Second Target Transport Beam-Line for the SNS Second Target Station

The Second Target Station (STS) project at the Spallation Neutron Source (SNS) is being developed to provide world-leading cold neutron brightness for next-generation neutron scattering experiments. The STS Accelerator Systems (AS) scope includes the design and implementation of the Ring-to-Second Target (RTST) proton beam transport line, which extracts 1.3 GeV proton beam pulses from the existing Ring-to-Beam Transport (RTBT) system and delivers them to the STS target. The RTST design emphasizes operational reliability [high reliability], low activation [minimum activation of components and the tunnel], maintainability, and compatibility with existing SNS infrastructure through extensive reuse of proven RTBT systems and components. The beamline includes a new extraction region, a transport lattice consisting of dipole, quadrupole, and corrector magnets, beam instrumentation systems, vacuum systems, personnel protection systems, and radiation shielding systems. Beam optics and particle tracking studies were performed using PyORBIT to validate extraction trajectories, beam transport, and target beam spot requirements [60–90 cm² beam spot area]. This paper presents the optics design philosophy, extraction system architecture, transport lattice design, instrumentation strategy, vacuum system approach, and radiation protection integration for the RTST beamline. Particle tracking simulations indicate successful beam transport without beam loss under nominal operating conditions. The RTST is designed to transport 1.3 GeV proton beam pulses at repetition rates up to 15 Hz, delivering nominal beam power of 700 kW to the Second Target Station.

Baron, Alex [ORNL]↗

Towards 10 meV resolution: The design of an ultrahigh resolution soft X-ray RIXS spectrometer

Here we present the optical design of the Centurion soft X-ray resonant inelastic X-ray scattering (RIXS) spectrometer to be located on the SIX beamline at NSLS-II. The spectrometer is designed to reach a resolving power of 100 000 at 1000 eV at its best resolution. It is also designed to have continuously variable 2θ motion over a range of 112° using a custom triple rotating flange. We have analyzed several possible spectrometer designs capable of reaching the target resolution. After careful analysis, we have adopted a Hettrick-Underwood spectrometer design, with an additional plane mirror to maintain a fixed direction for the outgoing beam. The spectrometer can cancel defocus and coma aberrations at all energies, has an erect focal plane, and minimizes mechanical motions of the detector. When the beamline resolution is accounted for, the net spectral resolution will be 14 meV at 1000 eV. Lastly, this will open up many low energy excitations to study and will expand greatly the power of soft X-ray RIXS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary investigation on young’s modulus measurement of cantilever beam by integrating nanoindenter with optical system

Nanoindenter has been used to directly indent on the cantilever beam to measure Young’s modulus such that the substrate effects can be avoided. However, the deflections of cantilever beam are indirectly extracted from the displacement of nanoindenter and therefore their measurement results are easily influenced by local behaviors around the indentation. In this paper, to the authors’ best knowledge, this is the first time that the nanoindenter is integrated with an optical system to measure Young’s modulus of cantilever beam. The deflection of cantilever beam is directly measured from a specially designed optical system. The influences of substrate effects and local behaviors around indentation are simultaneously avoided from the proposed methodology.

36 MATERIALS SCIENCE↗

Giant Modulation of Refractive Index from Picoscale Atomic Displacements

Abstract It is shown that structural disorder—in the form of anisotropic, picoscale atomic displacements—modulates the refractive index tensor and results in the giant optical anisotropy observed in BaTiS 3 , a quasi‐1D hexagonal chalcogenide. Single‐crystal X‐ray diffraction studies reveal the presence of antipolar displacements of Ti atoms within adjacent TiS 6 chains along the c ‐axis, and threefold degenerate Ti displacements in the a – b plane. 47/49 Ti solid‐state NMR provides additional evidence for those Ti displacements in the form of a three‐horned NMR lineshape resulting from a low symmetry local environment around Ti atoms. Scanning transmission electron microscopy is used to directly observe the globally disordered Ti a–b plane displacements and find them to be ordered locally over a few unit cells. First‐principles calculations show that the Ti a – b plane displacements selectively reduce the refractive index along the ab ‐plane, while having minimal impact on the refractive index along the chain direction, thus resulting in a giant enhancement in the optical anisotropy. By showing a strong connection between structural disorder with picoscale displacements and the optical response in BaTiS 3 , this study opens a pathway for designing optical materials with high refractive index and functionalities such as large optical anisotropy and nonlinearity.

36 MATERIALS SCIENCE↗