Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Signatures of nonthermal carriers in nonlinear photoluminescence

Ultrafast light emission from plasmonic nanostructures provides a sensitive probe of the energetic electrons generated by intense optical excitation. The way this emission scales with excitation intensity has long been read through the lens of heated electron populations at an elevated temperature, yet this picture cannot reconcile the variety of behaviors seen across different materials and experiments. We argue that transient nonthermal electrons play a far larger role than has been appreciated. We present a unified description that reproduces emission behavior across diverse systems and outline experiments needed to resolve their signatures.

nanoscale materials↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

A Concept of a Convection–Cloud Chamber to Study Aerosol–Cloud–Drizzle Interactions

Understanding and quantifying the full chain of processes from aerosol activation to drizzle formation, and the associated feedbacks to the aerosol chemical and physical properties, all within a turbulent cloud are some of the toughest challenges in atmospheric chemistry and physics and are keys to the cloud–precipitation puzzle. This paper describes a concept for a new type of research facility consisting of a cloud chamber plus associated instrumentation and computational models, to explore aerosol–cloud interactions and processing, cloud optical properties, entrainment–cloud interactions, and quantitative assessment of drizzle onset. The envisioned design is for a 3 m × 3 m × 9 m chamber, such that the height is sufficient to achieve long lifetimes for aerosol processing and for significant drizzle growth by collision and coalescence. A suite of computational tools for simulating microphysical properties in the chamber provides a digital twin for designing the chamber and a range of example experiments. Theory and test results from novel remote sensing systems for exploring chemical and physical interactions and evolution of aerosols, cloud droplets, and drizzle within turbulent clouds are described. Testing of technology needed for the operation of a large-volume chamber, including aerosol generation methods and novel materials for water vapor boundary conditions, is described. Simulations suggest that spatially uniform turbulence and microphysical properties can be sustained in a steady state, with reasonable aerosol and water vapor fluxes, and that substantial drizzle can be produced through collision and coalescence of cloud droplets. Remaining challenges for more detailed engineering design and a discussion of possible first-light experiments are described.

54 ENVIRONMENTAL SCIENCES↗

Luminescent Materials for the Detection of Economically Critical Metals in Harsh Environments

Renewable energy technologies used for electric vehicles and wind turbines are heavily reliant upon metals, such as rare earth elements, cobalt, lithium, and nickel. Indeed, there are 50 minerals that are currently considered “economically critical” by the 2022 United States Geological Survey. With anticipated global adoption of renewable energy technologies, producing sufficient metals to meet this demand presents a significant challenge, particularly due to the current monopolistic market for many of these metals. The production of metals from unconventional sources, such as coal utilization byproducts, is one of many promising strategies to boost domestic supply. However, sensitive, rapid, and inexpensive characterization technologies are needed to minimize production costs associated with metals prospecting and processing. Photoluminescence-based sensing techniques are particularly intriguing due to their potential for low cost and portability, coupled with high sensitivity and selectivity. This presentation focuses on the development of high-performance sensing materials for a range of critical metals, including metal-organic frameworks capable of sensitizing detection of parts-per-billion concentrations of six different rare earth elements, nanoparticles that can detect down to 600 parts-per-billion levels of cobalt, and thin films that sense aluminum down to 120 parts-per-billion. These materials are highly selective, capable of withstanding low pH conditions, and provide a response within minutes. Importantly, each sensing material is integrated with a custom-built, fully portable fiber-optic spectrometer for potential field deployment, providing significant cost savings over commercial instruments, along with potential advantages such as material regeneration for use across multiple sensing cycles and solvent removal for enhanced emission signal. These results highlight the exciting potential of luminescence platforms as cost-effective alternatives for metals characterization.

Crawford, Scott↗

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE↗

Towards the development of resonantly enhanced laser-based diagnostics for molten salt reactor safeguards

The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Evaluation of the hyperspectral radiometer (HSR1) at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site

Abstract. The Peak Design Ltd hyperspectral radiometer (HSR1) was tested at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site in Lamont, Oklahoma, for 2 months from May to July 2022. The HSR1 is a prototype instrument that measures total (Ftotal) and diffuse (Fdiffuse) spectral irradiance from 360 to 1100 nm with a spectral resolution of 3 nm. The HSR1 spectral irradiance measurements are compared to nearby collocated spectral radiometers, including two multifilter rotating shadowband radiometers (MFRSRs) and the Shortwave Array Spectroradiometer–Hemispheric (SASHe) radiometer. The Ftotal at 500 nm for the HSR1 compared to the MFRSRs has a mean (relative) difference of 0.01 W m−2 nm−1 (1 %–2 %). The HSR1 mean Fdiffuse at 500 nm is smaller than the MFRSRs' by 0.03–0.04 (10 %) W m−2 nm−1. The HSR1 clear-sky aerosol optical depth (AOD) is also retrieved by considering Langley regressions and compared to collocated instruments such as the Cimel sunphotometer (CSPHOT), MFRSRs, and SASHe. The mean HSR1 AOD at 500 nm is larger than the CSPHOT's by 0.010 (8 %) and larger than the MFRSRs' by 0.007–0.017 (6 %–18 %). In general, good agreement between the HSR1 and other instruments is found in terms of the Ftotal, Fdiffuse, and AODs at 500 nm. The HSR1 quantities are also compared at other wavelengths to the collocated instruments. The comparisons are within ∼ 10 % for the Ftotal and Fdiffuse, except for 940 nm, where there is relatively larger disagreement. The AOD comparisons are within ∼ 10 % at 415 and 440 nm; however, a relatively larger disagreement in the AOD comparison is found for higher wavelengths.

54 ENVIRONMENTAL SCIENCES↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the Impact of Radio-mode Feedback on the Properties of the Cool Circumgalactic Medium

We explore the influence of radio-mode feedback on the properties of the cool circumgalactic medium (CGM). To this end, we assemble a statistical sample of approximately 30,000 radio galaxies with background quasars by combining optical spectroscopic measurements of luminous red galaxies and quasars from the year 1 data set of the Dark Energy Spectroscopic Instrument and radio sources from the LOw-Frequency ARray Two-metre Sky Survey (LoTSS) DR2 catalog and the Very Large Array Sky Survey (VLASS) quick-look catalog. Galaxies with similar optical properties but with no radio counterparts in LoTSS and VLASS are selected as the control group. We measure the cool CGM properties of radio galaxies and their control samples traced by Mg ii absorption lines, including covering fraction, rest equivalent width, and gas kinematics. Our results show no significant difference in the properties of gas around radio galaxies and their control sample, indicating that the operating radio-mode feedback of massive galaxies does not produce detectable effects on the properties of the cool CGM. Finally, we show that the CGM of radio galaxies contains a nonnegligible amount of cool gas with approximately 10 10 M ⊙ . This abundance can place a stringent constraint on the radio-mode feedback models.

79 ASTRONOMY AND ASTROPHYSICS↗

Mirror-centered representation of a focusing hyperbolic mirror for X-ray beamlines

Conic sections are commonly used in reflective X-ray optics. Hyperbolic mirrors can focus a converging light source and are frequently paired with elliptical or parabolic mirrors in Wolter type configurations. This paper derives the closed-form expression for a mirror-centered hyperbolic shape, with zero-slope at the origin. Combined with the slope and curvature, such an expression facilitates metrology, manufacturing and mirror-bending calculations. Previous works consider ellipses, parabolas, magnifying hyperbolas or employ lengthy approximations. Here, the exact shape function is given in terms of the mirror incidence angle and the source and image distances.

47 OTHER INSTRUMENTATION↗

A cryogenic white light absorption spectroscopy setup with in situ gamma irradiation and thermo-optical annealing for optical fiber radiation-induced attenuation characterization

Silica optical fiber sensors offer a fast, distributed measurement solution in various cryogenic and radiation environments, such as magnets for fusion power. Under these conditions, light-absorbing point defects limit lifetime via radiation-induced attenuation (RIA). To support RIA kinetics prediction, we present an in situ, broadband absorption spectroscopy setup combining gamma irradiation with liquid nitrogen cooling. The apparatus enables continuous monitoring of narrowband RIA levels and the use of secondary optical annealing light sources, alongside broadband spectrum measurements to characterize RIA defects through spectrum decomposition. Initial results confirm the inevitable photobleaching effect of the probe light source, which must be accounted for. In addition, we report RIA kinetics during cycles of gamma irradiation at 77 K and isochronal thermal annealing steps from liquid nitrogen to room temperature, showcasing the setup’s ability to replicate real fiber operation scenarios. These instruments form an ideal platform to further study the kinetics of RIA coupled with thermal and optical annealing.

Absorption spectroscopy↗

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION↗

Product ion distributions using H 3 O + proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS): mechanisms, transmission effects, and instrument-to-instrument variability

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) using hydronium ion (H3O+) ionization is widely used for the measurement of volatile organic compounds (VOCs) both indoors and outdoors. H3O+ ionization, as well as the associated chemistry in an ion–molecule reactor, is known to generate product ion distributions (PIDs) that include other product ions besides the proton-transfer product. We present a method, using gas-chromatography pre-separation, for quantifying PIDs from PTR-MS measurements of nearly 100 VOCs of different functional types including alcohols, ketones, aldehydes, acids, aromatics, organohalides, and alkenes. We characterize instrument configuration effects on PIDs and find that reactor reduced electric field strength (E/N), ion optic voltage gradients, and quadrupole settings have the strongest impact on measured PIDs. Through an interlaboratory comparison of PIDs measured from calibration cylinders, we characterized the variability of PID production from the same model of PTR-MS across seven participating laboratories. Product ion variability was generally smaller (e.g., < 20 %) for ions with larger contributions to the PIDs (e.g., > 0.30) but less predictable for product ions formed through O2+ and NO+ reactions. We present a publicly available library of H3O+ PTR-MS PIDs that will be updated periodically with user-provided data for the continued investigation into instrument-to-instrument variability of PIDs.

Link, Michael F. (ORCID:0000000218412455)↗

Fiber-Optic Sensing for Earthquake Hazards Research, Monitoring, and Early Warning

The use of fiber‐optic sensing systems in seismology has exploded in the past decade. Despite an ever‐growing library of ground‐breaking studies, questions remain about the potential of fiber‐optic sensing technologies as tools for advancing if not revolutionizing earthquake‐hazards‐related research, monitoring, and early warning systems. A working group convened to explore these topics; we comprehensively examined the application of fiber optics in various aspects of earthquake hazards, encompassing earthquake source processes, crustal imaging, data archiving, and technological challenges. There is great potential for fiber‐optic systems to advance earthquake monitoring and understanding, but to fully unlock their capabilities requires continued progress in key areas of research and development, including instrument testing and validation, increased dynamic range for applications focused on larger earthquakes, and continued improvement in subsurface and source imaging methods. A key current stumbling block results from the lack of clear data archiving requirements, and we propose an initial strategy that balances data volume requirements with preserving key data for a broad range of future studies. In addition, we demonstrate the potential for fiber‐optic sensing to impact monitoring efforts by documenting the data completeness in a number of long‐term experiments. Finally, we outline the features of a instrument testing facility that would enable progress toward reliable and standardized distributed acoustic sensing data. Overcoming these current obstacles would facilitate progress in fiber‐optic sensing and unlock its potential application to a broad range of earthquake hazard problems.

58 GEOSCIENCES↗