Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARABOLIC FLIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Cardiovascular and Body Fluid Adjustments During Bed Rest and Space Flight

Although a few scientific bed rest (BR) studies were conducted soon after World War II, advent of the space program provided impetus for utilizing prolonged (days-months) BR, which employed the horizontal or 6 degree head-down tilt (HDT) body positions, to simulate responses of healthy people to microgravity. Shorter (hours) HDT protocols were used to study initial mechanisms of the acclimation-deconditioning (reduction of physical fitness) syndromes. Of the major physiological factors modified during BR, reduced force on bones, ligaments, and muscles, and greatly reduced hydrostatic pressure within the cardiovascular system, the latter: which involves shifts of blood from the lower extremities into the upper body, increase in central venous pressure, and diuresis, appears to be the initial stimulus for acclimation. Increase in central venous pressure occurs in subjects during weightless parabolic flight, but not in astronauts early during orbital flight. But significant reduction in total body water (hypohydration) and plasma volume (hypovolemia) occurs in subjects during both BR and microgravity. Response of interstitial fluid volume is not as clear, It has been reported to increase during BR, and it may have increased in Skylab II and IV astronauts. Reduction of total body water, and greater proportional reduction of extracellular volume, indicates increased cellular volume which may contribute to inflight cephalic edema. Cerebral pressure abates after a few days of HDT, but not during flight. accompanied by normal (eugravity) blood constituent concentrations suggesting some degree of acclimation had occurred. But during reentry, with moderately increased +Gz (head-to-foot) acceleration and gravitational force, the microgravity "euhydration" becomes functional progressive dehydration contributing to the general reentry syndrome (GRS) which, upon landing the Shuttle, can and often results in gastrointestinal distress, disorientation, vertigo, fatigue, and fainting. Various pre-reentry hyperhydration procedures have been utilized to counteract the GRS. Thus, the somewhat decreased central venous pressure and lack of diuresis early in spaceflight suggests mechanisms other than the Gauer-Henry reflex are more important for maintaining fluid volume homeostasis in astronauts. Inflight hypohydration and hypovolemia are more important for maintaining fluid volume homeostasis in astronauts.

Greenleaf, John E.↗

Maturation of In-space Welding in Reduced Gravity and Reduced Pressure Environments Through Progression to Suborbital Flight Experiments

Development of in-space welding (ISW) is a key and enabling manufacturing technology as welding is currently involved in producing approximately 90% of durable goods, and this trend is expected to hold for in-space manufacturing as well. ISW is critical to a sustainable space economy. To mature in-space welding, numerous gaps must be closed since NASA has not made a weld in space in 50 years. Advancing laser beam welding (LBW) towards a suborbital flight demonstration will help mature the process for in-space assembly & manufacturing (ISAM) through demonstration in relevant environments and achieving technology readiness milestones. LBW technologies and science improved by this work will benefit in-space manufacturing, long-term sustainability of space structures & operations, and the overall space economy. Ground-based welding of aerospace hardware requires an Edisonian approach to qualify a welding process; however, this approach is infeasible for ISW qualification due to mass, volume, logistic, and cost challenges inherent to the space environment. To address this challenge, we are conducting ground and suborbital tests with partners performing parabolic flights to gather data on LBW processes and infuse them into NASA & partner missions. This progression from ground to flight experiments will elucidate relevant physics during LBW: 1) reduced gravity, 2) reduced pressure, and 3) extreme temperature. Data from post-flight evaluation and in situ instrumentation will feed integrated computational materials engineering (ICME) tools to reduce the burden of ISW infusion by establishing a link between space and terrestrial environments, ultimately accelerating the qualification of LBW in space.

in-space welding↗

Venipuncture and intravenous infusion access during zero-gravity flight

The purpose of this experiment is to establish the difficulty associated with securing an intravenous (IV) catheter in place in microgravity flight and the techniques applicable in training the Crew Medical Officer (CMO) for Space Station Freedom, as well as aiding in the selection of appropriate hardware and supplies for the Health Maintenance Facility (HMF). The objectives are the following: (1) to determine the difficulties associated with venipuncture in a microgravity environment; (2) to evaluate the various methods of securing an IV catheter and attached tubing for infusion with regard to the unique environment; (3) to evaluate the various materials available for securing an intravenous catheter in place; and (4) to evaluate the fluid therapy administration system when functioning in a complete system. The inflight test procedures and other aspects of the KC-135 parabolic flight test to simulate microgravity are presented.

Krupa, Debra T.↗

Particular Characterisation of an In-Vitro-DTH Test to Monitor Cellular Immunity - Applications for Patient Care and Space Flight

Goal:i) Characterization of the role of the main immune reactive cell types contributing to the cellular immune response in the in-vitro DTH and ii) Validation of the in-vitro DTH under different clinical and field conditions. Methods:As positive control whole blood was incubated in the in-vitro DTH, supernatants were gathered after 12, 24 and 48h. Readout parameters of this test are cytokines in the assay's supernatant. To determine the role of T-cells, monocytes and natural killer (NK), these cell populations were depleted using magnetic beads prior to in-vitro-DTH incubation. Validation of the test has occurred under clinical (HIV-patients, ICU) and field-conditions (parabolic/space-flights, confinement). Results:T-cell depletion abandoned almost any IL-2 production and reduced IFN-gamma production irrespective of the type of antigen, whereas CD56 depleted cultures tended to lower IL-2 secretion and IFN-gamma and to parallel a IL-10-increase after viral challenge. This IL-10-increase was seen also in CD14-depleted setups. DTH read-out was significantly different under acute stress (parabolic flight) or chronic stress (ISS), respectively. Preliminary data of HIV infected patients demonstrate that this test can display the contemporary immune status during an antiviral therapy. Conclusion:The in-vitro DTH mirrors adaptive and innate immune activation and may serve as tool also for longitudinal follow up of Th1/Th2 weighed immune response under adverse life conditions on earth and in space. It is planned to implement the assay in the on the ISS (MoCISS).

Feurecker, M.↗

Effect of Changing Weight and Mass on Human Performance in a Lunar Prototype Spacesuit

Physical effort, compensation, and controllability in a spacesuit can be affected by suit mass and gravity level. Because of limitations in certain reduced-gravity simulators and the finite selection of lunar prototype suits, it is difficult to ascertain how a change in suit mass affects suited human performance. One method of simulating a change in mass is to vary the total gravity-adjusted weight (TGAW), which is defined as the sum of the suit mass and subject mass, multiplied by the gravity level. PURPOSE: To determine if two methods of changing TGAW during parabolic flight - changing suit mass or gravity level - affect subjective ratings of suited human performance equally.METHODS: A custom weight support structure was connected to a lunar prototype spacesuit, allowing the addition of mass to the suit while maintaining a near-constant center of mass. In the varied-weight (VW) series, suit mass (120 kg) was constant at 0.1-g, 0.17-g, and 0.3-g, yielding TGAWs of 196, 333, and 588 N, assuming an 80-kg subject. In the varied-mass (VM) series, gravity level was constant at 0.17-g and suit mass was 89, 120, and 181 kg, yielding TGAWs of 282, 333, and 435 N. The 333 N condition was common to both series. Direct comparison was not possible due to limited adjustability of suit mass and limited options for parabolic profiles. Five astronaut subjects (80.311.8 kg) completed 4 different tasks (walk, bag pickup, lunge, and shoveling) in all conditions and provided ratings of perceived exertion (RPE) and the gravity compensation and performance scale (GCPS) upon completion of each task. RESULTS: Where VM and VW series overlapped, RPE and GCPS trend lines were similar. Mean RPE and GCPS at 333 N was 8.4 and 3.7. Mean RPE and GCPS for VM was 7.8 and 3.8 for 282 N and 9.8 and 4.1 for 435 N. Extrapolation of the VM trend to match VW TGAWs 196 and 588 N predicts an RPE of 6.5 and 12.3 and GCPS of 4.4 and 5.9, whereas the measured VW values for RPE were 8.1 and 9.8 and GCPS were 4.4 and 3.7. CONCLUSION: Modeling a change in suit mass by altering weight alone may be an adequate simulation through a limited range when looking at gross metrics of subjective suited human performance. Whether altering weight alone will be sufficient for more precise metrics of human performance, and across a wider range of activities, still needs further study

Chappell, Steve↗

Effect of Changing Weight and Mass on Human Performance in a Lunar Prototype Spacesuit

Physical effort, compensation, and controllability in a spacesuit can be affected by suit mass and gravity level. Because of limitations in certain reduced-gravity simulators and the finite selection of lunar prototype suits, it is difficult to ascertain how a change in suit mass affects suited human performance. One method of simulating a change in mass is to vary the total gravity-adjusted weight (TGAW), which is defined as the sum of the suit mass and subject mass, multiplied by the gravity level. PURPOSE: To determine if two methods of changing TGAW during parabolic flight - changing suit mass or gravity level - affect subjective ratings of suited human performance equally. METHODS: A custom weight support structure was connected to a lunar prototype spacesuit, allowing the addition of mass to the suit while maintaining a near-constant center of mass. In the varied-weight (VW) series, suit mass (120 kg) was constant at 0.1 G, 0.17 G, and 0.3 G, yielding TGAWs of 196, 333, and 588 N, assuming an 80-kg subject. In the varied-mass (VM) series, gravity level was constant at 0.17 G and suit mass was 89, 120, and 181 kg, yielding TGAWs of 282, 333, and 435 N. The 333 N condition was common to both series. Direct comparison was not possible due to limited adjustability of suit mass and limited options for parabolic profiles. Five astronaut subjects (80.3 11.8 kg) completed 4 different tasks (walk, bag pickup, lunge, and shoveling) in all conditions and provided ratings of perceived exertion (RPE) and the gravity compensation and performance scale (GCPS) upon completion of each task. RESULTS: Where VM and VW series overlapped, RPE and GCPS trendlines were similar. Mean RPE and GCPS at 333 N was 8.4 and 3.7. Mean RPE and GCPS for VM was 7.8 and 3.8 for 282 N and 9.8 and 4.1 for 435 N. Extrapolation of the VM trend to match VW TGAWs 196 and 588 N predicts an RPE of 6.5 and 12.3 and GCPS of 4.4 and 5.9, whereas the measured VW values for RPE were 8.1 and 9.8 and GCPS were 4.4 and 3.7. CONCLUSION: Modeling a change in suit mass by altering weight alone may be an adequate simulation through a limited range when looking at gross metrics of subjective suited human performance. Whether altering weight alone will be sufficient for more precise metrics of human performance, and across a wider range of activities, still needs further study.

Norcross, Jason R.↗

Principles of Fluid Dynamic Similarity Analysis for Slosh Experiments

Most tank slosh test programs are not conducted with flight hardware in a flight-like environment due to cost and schedule constraints. Instead, subscale tanks are typically tested on the ground. If the “real”, flight liquid in the tank is a cryogenic propellant, sometimes a cryogen is used during testing, but more often a simulant liquid is used. Fluid dynamic similarity analysis, or “scaling analysis” as it is sometimes called, for slosh examines nondimensional numbers to determine which fluid dynamic regime(s) a tank is operating in. If the relevant nondimensional numbers of a scale tank test are similar enough to the real tank’s nondimensional numbers, then it is likely that the scale test data will be similar to what would be obtained with the real tank. This type of analysis is useful for guiding experiment design, test liquid selection, and for understanding the physical relevance of prior test data to a specific application. The authors have performed scaling analyses for many slosh test programs conducted in ground, parabolic flight, suborbital, and in-orbit environments. Basics of how to perform the analysis, along with select examples from ground and microgravity environments, are presented. Suggestions for various assumptions and compromises to make are discussed. Limitations and challenges are also discussed.

slosh↗

Stroboscopic Vision as a Treatment for Space Motion Sickness

Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill Jones we have evaluated stroboscopic vision as a method of preventing motion sickness. Given that the data presented by professor Melvill Jones were primarily post hoc results following a study not designed to investigate motion sickness, it is unclear how motion sickness results were actually determined. Building on these original results, we undertook a three part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness using: (1) visual field reversal, (2) Reading while riding in a car (with or without external vision present), and (3) making large pitch head movements during parabolic flight.

Reschke, Millard F.↗

Stroboscopic Vision as a Treatment Motion Sickness

Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill-Jones, we have evaluated stroboscopic vision as a method of preventing motion sickness. Methods: Nineteen subjects read text while making +/-20deg head movements in the horizontal plane at 0.2 Hz while wearing left-right reversing prisms during exposure to 4 Hz stroboscopic or normal room illumination. Testing was repeated using LCD shutter glasses as the stroboscopic source with an additional 19 subjects. Results: With Strobe, motion sickness was significantly lower than with normal room illumination. Results with the LCD shutter glasses were analogous to those observed with environmental strobe. Conclusions: Stroboscopic illumination appears to be effective where retinal slip is a factor in eliciting motion sickness. Additional research is evaluating the glasses efficacy for, carsickness, sickness in parabolic flight and seasickness. There is evidence from pilot studies showing that the glasses reduce saccade velocity to visually presented targets by approximately half of the normal values. It is interesting to note that adaptation to space flight may also slow saccade velocity.

Reschke, Millard F.↗

Design and Testing of the BionicWingSat in a Zero-g Flight Campaign - A 2U-CubeSat with Deployable, Biologically-Inspired Wings

In this paper, recent developments in the design, manufacturing, and testing of a novel deployable structure with several potential applications in space will be described. Through a cooperative effort of the German Aerospace Center (DLR) and the National Aeronautics and Space Administration (NASA), a biologically inspired structurally integrated membrane featuring distributed functional elements has been developed and tested in a 2U CubeSat called BionicWingSat. Such a membrane structure could be useful for several applications in which a relatively flat area is desirable such as solar sails, drag sails, or solar shades. For SmallSats and CubeSats, the design proposed also has the desirable property of being self-deploying without the need for powered deployment mechanisms. Building on previous work inspired by the wings of earwigs, the research presented in this paper includes structural design of self-deploying hinges, a survey of various advanced additive layer manufacturing (ALM) methods for making hinges, mechanical characterization of the hinges, and finite element analysis (FEA) of the hinges. In this work, the conflicting goals of maximizing deployed structural stiffness, maximizing deployed area, maximizing stowed packaging efficiency, and maximizing resistance to creep when stowed must be considered. The resulting design concept is a gossamer structure that cannot support its own weight in gravity. For this reason, a focus in this paper is on a parabolic flight test campaign in which 24 fully integrated wings on two BionicWingSats were tested in a microgravity environment. From this test campaign, several lessons were learned regarding the wing design and procedures for carrying out microgravity tests of this manner.

CubeSat↗

Design and Testing of the BionicWingSat in a Zero-g Flight Campaign - A 2U-CubeSat with Deployable, Biologically-Inspired Wings

In this paper, recent developments in the design, manufacturing, and testing of a novel deployable structure with several potential applications in space will be described. Through a cooperative effort of the German Aerospace Center (DLR) and the National Aeronautics and Space Administration (NASA), a biologically inspired structurally integrated membrane featuring distributed functional elements has been developed and tested in a 2U CubeSat called BionicWingSat. Such a membrane structure could be useful for several applications in which a relatively flat area is desirable such as solar sails, drag sails, or solar shades. For SmallSats and CubeSats, the design proposed also has the desirable property of being self-deploying without the need for powered deployment mechanisms. Building on previous work inspired by the wings of earwigs, the research presented in this paper includes structural design of self-deploying hinges, a survey of various advanced additive layer manufacturing (ALM) methods for making hinges, mechanical characterization of the hinges, and finite element analysis (FEA) of the hinges. In this work, the conflicting goals of maximizing deployed structural stiffness, maximizing deployed area, maximizing stowed packaging efficiency, and maximizing resistance to creep when stowed must be considered. The resulting design concept is a gossamer structure that cannot support its own weight in gravity. For this reason, a focus in this paper is on a parabolic flight test campaign in which 24 fully integrated wings on two BionicWingSats were tested in a microgravity environment. From this test campaign, several lessons were learned regarding the wing design and procedures for carrying out microgravity tests of this manner.

CubeSat↗

Inhomogeneity of pulmonary ventilation during sustained microgravity as determined by single-breath washouts

Gravity is known to cause inhomogeneity of ventilation. Nongravitational factors are also recognized, but their relative contribution is not understood. We therefore studied ventilatory inhomogeneity during sustained microgravity during the 9-day flight of Spacelab SLS-1. All seven crew members performed single-breath nitrogen washouts. They inspired a vital capacity breath of 100% oxygen with a bolus of argon at the start of inspiration, and the inspiratory and expiratory flow rates were controlled at 0.5 l/s. Control measurements in normal gravity (1 G) were made pre- and postflight in the standing and supine position. Compared with the standing 1-G measurements, there was a marked decrease in ventilatory inhomogeneity during microgravity, as evidenced by the significant reductions in cardiogenic oscillations, slope of phase III, and height of phase IV for nitrogen and argon. However, argon phase IV volume was not reduced, and considerable ventilatory inhomogeneity remained. For example, the heights of the cardiogenic oscillations during microgravity for nitrogen and argon were 44 and 24%, respectively, of their values at 1 G, whereas the slopes of phase III for nitrogen and argon were 78 and 29%, respectively, of those at 1 G. The presence of a phase IV in microgravity is strong evidence that airway closure still occurs in the absence of gravity. The results were qualitatively similar to those found previously during short periods of 0 G in parabolic flight.

Guy, Harold J. B.↗

Context-Specific Adaptation of Gravity-Dependent Vestibular Reflex Responses

Stabilization of the eyes and head during body movements is important for maintaining balance and keeping the images of objects stationary on our retinas. Impairment of this ability can lead to disorientation and reduced performance in sensorimotor tasks such as piloting of spacecraft. In the absence of a normal earth gravity field, the dynamics of head stabilization, and the interpretation of vestibular signals that sense gravity and linear acceleration, are subject to change. Transitions between different gravitoinertial force environments - as during different phases of space flight - provide an extreme test of the adaptive mechanisms that maintain these reflexive abilities. It is vitally important to determine human adaptive capabilities in such a circumstance, so that we can know to what extent the sensorimotor skills acquired in one gravity environment will transfer to others. Our work lays the foundation for understanding these capabilities, and for determining how we can aid the processes of adaptation and readaptation. An integrated set of experiments addresses this issue. We use the general approach of adapting some type of reflexive eye movement (saccades, the angular vestibulo-ocular reflex (AVOR), the linear vestibulo-ocular reflex (LVOR)), or the vestibulo-collic reflex (VCR), to a particular change in gain or phase in one condition of gravitoiner-tial force, and adapting to a different gain or phase (or asking for no change) in a second gravitoinertial force condition, and then seeing if the gravitoinertial force itself - the context cue - can recall the previously learned adapted responses. The majority of the experiments in the laboratory use the direction of vertical gaze or the direction of gravity (head tilt) as the context cue. This allows us to study context-specificity in a ground-based setting. One set of experiments, to be performed in parabolic flight, specifically uses the magnitude of gravitoinertial force as a context cue. This is a much better analog of the situation encountered in space flight. Various experiments investigate the behavioral properties, neurophysiological basis, and anatomical substrate of context-specific learning mechanisms. We use otolith (gravity) signals as the contextual cue for switching between adapted states of the saccadic system, the angular and linear vestibulo-ocular reflexes, and the VCR. (By LVOR we mean the oculomotor response - horizontal, vertical, and torsional - to linear translation of the head and body.) We are studying the effect of context on adaptation of saccade gain, phase and gain of the AVOR and LVOR, on ocular counterrolling (OCR) in response to static head tilt, and on head/neck reflexes (VCR) in response to rotation in different orientations. Such research is particularly germane to potential problems of postural and oculomotor control upon exposure to different gravitational environments.

Shelhamer, Mark J.↗

Myotonometry as a Surrogate Measure of Muscle Strength

Space flight-induced muscle atrophy/neuromuscular degradation and the consequent decrements in crew-member performance are of increasing concern as mission duration lengthens, and planetary exploration after extended space flight is planned. Pre- to post-flight strength measures have demonstrated that specific countermeasures, such as resistive exercise, are effective at countering microgravity-induced muscle atrophy and preventing decrements in muscle strength. However, in-flight assessment/monitoring of exercise countermeasure effectiveness will be essential during exploration class missions due to their duration. The ability to modify an exercise countermeasure prescription based on such real-time information will allow each individual crew member to perform the optimal amount and type of exercise countermeasure to maintain performance. In addition, such measures can be used to determine if a crew member is physically capable of performing a particular mission-related task during exploration class missions. The challenges faced in acquiring such data are those common to all space operations, namely the requirement for light-weight, low power, mechanically reliable technologies that make valid measurements in microgravity, in this case of muscle strength/neuromuscular function. Here we describe a simple, light-weight, low power, non-invasive device, known as the Myotonometer, that measures tissue stiffness as an indirect measure of muscle contractile state and muscle force production. Repeat myotonometer measurements made at the same location on the surface of the rectis femoris muscle (as determined using a 3D locator device, SEM plus or minus 0.34 mm) were shown to be reproducible over time at both maximal voluntary contraction (MVC) and at rest in a total of 17 sedentary subjects assessed three times over a period of seven days. In addition, graded voluntary isometric force production (i.e. 20%, 40%, 60%, 80% & 100% of MVC) during knee extension was shown to be significantly (p less than 0.01) correlated with contemporaneous myotonometer measurements made on the rectis femoris muscle in a total of 16 healthy subjects (8 males, 8 females). Further-more, this device has been operationally tested during parabolic flight demonstrating its suitability for use in a microgravity environment. Our data indicates that the Myotonometer is a viable surrogate measure of muscle contractile state/tone and of muscle strength/force production. Additional studies are required to assess the suitability of this technique for assessing these measures in de-conditioned subjects such as crew-members.

Ang, B. S.↗

Laser diagnostics for microgravity droplet studies

An instrument has been designed, built, and tested for performing laser diagnostic measurements of droplet combustion in low-gravity-flight aircraft. Nonintrusive measurements are of particular importance for droplet combustion (the simplest example of non-premixed combustion) and transport in microgravity environments, where physical contact would introduce an unacceptable level of perturbations. The resolution of these diagnostics can also isolate transport to length scales much smaller than the droplet diameter. These techniques can be configured to instantaneously map an entire flow field in two and three dimensions, providing either qualitative or quantitative information on the distribution of a desired scalar or vector quantity. Detailing the gas-phase flow field and position of the flame front can be achieved using planar laser-induced fluorescence (PLIF) of OH or another flame front marker. An alternative approach is to obtain LIF from a diagnostic seed included in the liquid phase fuel; it would be consumed at the flame front. The main advantage to this approach is that it is easier to choose the wavelength of the molecular absorption which coincides with convenient laser wavelengths rather than finding lasers which can be configured to access OH. Our present method uses a nitrogen-pumped dye laser tuned to a sodium absorption and addition of small concentrations of NaCl to the fuel. Particle image velocimetry (PIV) is a laser-based technique which has recently had its practicality greatly enhanced by the development of high-resolution CCD cameras and the increase in speed and capacity of computer systems. With this technique, a seeded flow is illuminated with a double-pulsed laser sheet to generate a double exposure image on a film or CCD camera. Computer analysis of the image is used to determine the particle velocity vectors and, thus, the gas velocity within the plane of the laser sheet. Our current experiment uses PIV for measuring relative droplet gas-phase velocities in a parabolic flight environment. The results show successful application of PLIF relative to luminosity and radical emission near 308 nm. PIV results are less successful due to gas thermal expansion deflecting the seed particles away from the measurement volume. PIV is applicable for measurements in the absence of combustion.

Winter, Michael↗

Integrated Model of the Eye/Optic Nerve Head Biomechanical Environment

Visual Impairment and Intracranial Pressure (VIIP) syndrome is a concern for long-duration space flight. Previously, it has been suggested that ocular changes observed in VIIP syndrome are related to the cephalad fluid shift that results in altered fluid pressures [1]. We are investigating the impact of changes in intracranial pressure (ICP) using a combination of numerical models, which simulate the effects of various environment conditions, including finite element (FE) models of the posterior eye. The specific interest is to understand how altered pressures due to gravitational changes affect the biomechanical environment of tissues of the posterior eye and optic nerve sheath. METHODS: Additional description of the numerical modeling is provided in the IWS abstract by Nelson et al. In brief, to simulate the effects of a cephalad fluid shift on the cardiovascular and ocular systems, we utilized a lumped-parameter compartment model of these systems. The outputs of this lumped-parameter model then inform boundary conditions (pressures) for a finite element model of the optic nerve head (Figure 1). As an example, we show here a simulation of postural change from supine to 15 degree head-down tilt (HDT), with primary outcomes being the predicted change in strains at the optic nerve head (ONH) region, specifically in the lamina cribrosa (LC), retrolaminar optic nerve, and prelaminar neural tissue (PLNT). The strain field can be decomposed into three orthogonal components, denoted as the first, second and third principal strains. We compare the peak tensile (first principal) and compressive (third principal) strains, since elevated strain alters cell phenotype and induces tissue remodeling. RESULTS AND CONCLUSIONS: Our lumped-parameter model predicted an IOP increase of c. 7 mmHg after 21 minutes of 15 degree HDT, which agreed with previous reports of IOP in HDT [1]. The corresponding FEM simulations predicted a relative increase in the magnitudes of the peak tensile and compressive strains in the lamina cribrosa of 42 and 43, respectively (Fig. 2). The corresponding changes in the optic nerve strains were 17 and 39, while in the PLNT they were 47 and 43. These magnitudes of relative elevations in peak strains may induce a phenotypic response in resident mechano-responsive resident cells [2]. This approach may be expanded to investigate other environmental changes (e.g. parabolic flight). Through our VIIP SCHOLAR project, we will validate and improve these integrated models by measuring patient-specific changes in optic nerve sheath geometry in patients with idiopathic intracranial hypertension before and after lumbar puncture and CSF removal.

biomechanics↗

Demonstration and analysis of volumetric additive manufacturing via sub-orbital spaceflight testing

Computed Axial Lithography (CAL) represents a significant advancement in the emerging field of Volumetric Additive Manufacturing (VAM). CAL addresses key limitations of traditional photopolymer additive manufacturing technologies, by eliminating the need for layering and support structures. Unlike conventional methods, CAL prints components by illuminating all points within a desired geometry simultaneously, using tomographic reconstruction to form the object in a single step. This unique approach eliminates the relative motion between the object and the precursor material, enabling faster printing speeds and reducing the waste associated with support structures. However, CAL parts require post-processing steps before they can be utilized. CAL's core attributes make it particularly suited for In-Space Manufacturing (ISM), due to its fast fabrication times, wide breadth of materials it can use, and minimized footprint. CAL has been successfully demonstrated in microgravity during parabolic flight experiments. However to fully validate and understand CAL's behaviour in microgravity, all manufacturing and post-processing steps must be integrated. In June 2024, we conducted SpaceCAL Mission 3, testing this entire workflow on a suborbital flight aboard Virgin Galactic's SpaceShipTwo. During ~140 s of microgravity, the system autonomously manufactured and post-processed four parts using PEGDA700 resin. Post-flight analysis showed that 2/4 parts were recognisable, while others were distorted due to bubble formation from residual water droplets, off-axis optical aberrations, and non-uniform solvent rinsing. Despite these limitations, this study represents the first integrated CAL workflow in space, providing an initial experimental demonstration and analysis for closed-loop in-space manufacturing.

Waddell, Taylor [Department of Mechanical Engineer↗