Search NASA⌕ Search

SEARCH · Search NASA

Results for “PCM energy storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

194 records · Page 11

Experimental Study on Charging and Discharging Performance of a Dual-Purpose Underground Thermal Battery

A dual-purpose underground thermal battery (DPUTB) was proposed for Grid-interactive Efficient Buildings. It integrates underground thermal energy storage with a shallow-buried ground heat exchanger (less than 6 m deep). The charging and discharging performance of a lab-scale DPUTB were experimentally investigated. The test results show that the lab-scale (1:125 in volume) DPUTB can provide 34 W cooling continuously for 3.7 h with a supply water temperature below 14°C. The water temperature rise of the inner tank was slowed down during the discharging process due to the phase change of the phase change material (PCM). Thermal storage capacity was increased by 156% using the PCM that only occupied 19% volume of the inner tank. The heat lost from the inner tank was recovered in the outer tank and led to the efficiency improvement of a ground source heat pump.

Wang, Lingshi↗

Neutron Absorber Plate Characterization Plan for Criticality Experiments Design

After being used in nuclear installations, depleted fuel can still be highly reactive and must be handled securely to prevent any radiological or criticality concerns. In particular, spent fuel from use in nuclear power reactors must be stored and transported in specifically designed containers using neutron absorber materials to prevent criticality. Various neutron absorber material types exist and are manufactured by various entities, as thoroughly described in the Handbook of Neutron Absorber Materials for Spent Nuclear Fuel Storage and Transportation Applications written by EPRI. Presently, one of the most modern and most widely used types of neutron absorber material contains particles of boron carbide, or B 4 C, embedded in aluminum matrix: Boralcan, manufactured by Rio Tinto. It is very important for the community to know as much as possible about such neutron absorber materials. Therefore, in the recent years, a US Department of Energy National Nuclear Security Administration–Nuclear Criticality Safety Program funded project initiated design of an experiment that places Boralcan neutron-absorbing plates in an established critical assembly using low-enriched uranium fuel at the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories. The goal of the experiment is to produce high-quality benchmark data to submit to the International Criticality Safety Benchmark Evaluation Project (ICSBEP), for use in validating calculational tools and nuclear data by criticality safety analysts. The project, named IER-554, is currently in its final design stage, following a successful preliminary design. In the work documented in the design study, ten critical configurations using Boralcan neutron absorber plates were designed, and the experiment was proven to be feasible, with a predicted low k eff uncertainty around 100 pcm. An overview of the modeled cutout of the critical assembly with a Boralcan plate is shown in Figure 1, representing one of the configurations planned for the critical experiments. Before the plates are inserted in the critical assembly, it is necessary to know more about their composition and uniformity. This summary focuses on the plate characterization plans. Each plate will undergo (1) neutron transmission measurements at different locations to determine the 10 B areal density and (2) an in-depth x-ray computed tomography (XCT) examination to obtain the exact Sizes and distribution of the B4C powder particles inside the plates. In parallel, plate modeling studies are performed with a goal to determine the validity of the currently used approximation of modeling the neutron absorber plates as a homogeneous mixture of Aluminum 1100 alloy and B4C— instead of explicitly modeling the B4C particles. By using the experimental 10 B areal density measurements, and the exact size and location of the B4C particles obtained by XCT, a plate model can theoretically be built that reproduces the plate with extremely high fidelity. The results of this modeling study could increase the confidence of the criticality safety community in its modeling methods when using this type of neutron absorber material, and the industry could use these validations to change the boron loading credit limits from the U.S. Nuclear Regulatory Commission standard review plan for dry cask storage of spent nuclear fuel. The modeling calculations are performed with SCALE 6.3.0 using the KENO V.a sequence for criticality calculations with the ENDF/B-VIII.0 continuous-energy cross section library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating Utility-Scale PV-Battery Hybrids in an Operational Model for the Bulk Power System

Systems that combine solar photovoltaic and battery energy storage technologies (PV-BES) are increasingly being proposed and deployed on the bulk power system. The operations and value of PV-BES systems have been extensively studied from the project developer's perspective through analyses that maximize plant-level revenue. However, PV-BES hybrids' operational characteristics are seldom studied from the perspective of bulk power system operators, who seek to optimize the performance of a suite of generation and storage assets that are connected via the transmission network. This work presents modeling approaches for representing and evaluating PV-BES hybrids in a model that optimizes operations across the bulk power system. Its novel contributions include demonstrating a technique to modify a unit commitment and dispatch model to represent the operational synergies of PV-BES hybrids. In particular, we describe the challenges and an approach for representing so-called DC-coupled PV-BES - which utilize a single bi-directional inverter - as a dispatchable resource in a commercial, production cost model (PCM), PLEXOS. We demonstrate this technique in a PCM study of the Los Angeles Department of Water and Power (LADWP) test system, by replacing existing PV and battery generators on the test system with our PV-BES hybrids. We then pursue scenario analysis that is designed to isolate the various drivers of operational strategies for DC-coupled PV-BES hybrids, including the nature of coupling, PV penetration on the system, and varying inverter loading ratios (or degrees of over-sizing of the PV field). Results from the analysis include utilization profiles for the PV DC energy across available pathways, dispatch profiles for the battery component, and the hybrid technologies' impacts on system-wide production costs. The approach presented in this paper can be used in any PCM that is looking to study PV-BES hybrids as a resource in different power system configurations and services.

14 SOLAR ENERGY↗

In‐operando crystallization study of zinc nitrate hexahydrate using zinc oxide nucleators

Abstract Supercooling (∆T Sup ) is one of the crucial problems in utilizing a phase change material (PCM), which has been attempted to overcome using nucleators possessing small lattice disregistry without comprehensive understanding of the nucleation phenomenon. Here, this work studies the interactions between nucleators and PCM via in‐operando direct visualization for the first time, to the best of our knowledge, to better understand the crystallization process during freezing of a PCM using zinc nitrate hexahydrate (ZNH) and a zinc oxide (ZnO) nucleator. According to our in‐operando study, freezing was randomly initiated by only a fraction of the nucleator particles during each thermal cycling. However, previously unresponsive nucleators also suddenly crystalized PCM when the propagating crystal encountered them, improving the crystal initiation and thereby ∆T Sup . Consequently, for equal wt% of ZnO, better nucleation behavior was obtained using uniformly distributed small nucleator particles throughout the PCM, as compared to either large or poorly distributed aggregated nucleators. DSC results using ZnO‐needle as nucleator confirmed a 38% and 33.3% lower ∆T Sup upon employing 5 wt% small (individual) particles (~4 μm on average), as compared to using equal wt% of small (aggregated) particle clusters (~200 μm) and large particles (~46 μm), respectively. Crystallization of ZNH caused additional hair‐like ZnO growth preferentially decorated along lateral faces of the original nucleator particles. The in‐operando studies are valuable tools to correlate inherent crystallization phenomena to the practical thermal energy storage properties of the system.

Chakraborty, Anirban↗

Automated Parameterized CFD Simulations of Phase-Change Material Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers is typically computationally intensive due to the relative complex time-dependent underlying physics. This paper presents a study investigating a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 37oC nominal melting temperature, leveraging automated parametric CFD simulations. The computational domain is reduced to 2D axisymmetric for a segment of the HX comprising a region in between two fins with constant wall temperature as boundary condition. This approach allows for faster evaluations of the transient thermal characteristics for a given design space of interest. Correlations and reduced order models (ROM’s) are developed. Results indicate that the ROM’s reproduce the CFD simulations with high accuracy for designs from the training data set, however, designs from cross-validation and test sets do not always have good agreement. The limited number of designs in the training set is a possible cause for the lack of robustness of the ROM’s and thus additional training designs will be added in future work. The ROM’s solve the simulations on average 500,000 times faster than CFD.

25 ENERGY STORAGE↗

In-situ observation of calcium chloride hexahydrate phase separation via neutron imaging

Inorganic salt hydrate offers a low-cost thermal energy storage solution with high energy density, but phase separation during thermal cycling poses a significant challenge, leading to irreversible performance degradation. In this research, neutron radiography was used to investigate phase separation in calcium chloride hexahydrate (CaCl₂·6H₂O, CCH) during thermal cycling to track its gradual accumulation into calcium chloride tetrahydrate (CaCl₂·4H₂O, CC4). Through in-situ visualization, phase separation and CC4 sedimentation were observed to occur during the cooling phase between 301.40 K and 304.80 K. CC4 accumulated linearly to 7.99 wt% after 10 thermal cycles. Crystallization and multi-cycle conversion models were developed to validate neutron imaging results of CC4 formation. The predicted CC4 content after 10 thermal cycles closely aligned with experimental observations. Neutron imaging offers a novel approach to investigate salt hydrate phase change materials (PCMs). It enables in-situ visualization of sub-hydrate (CC4) formation from original hydrate (CCH) in metastable phase change range (between 301.40 ± 0.66 K and 304.80 ± 0.60 K). Thereby, it provides a new insight of understanding the basis of phase separation mechanism and paves the way for future research of improving PCM thermal cycling performance.

Li, Yucen [The University of Tennessee, Knoxville]↗

A Novel Framework for Performance Evaluation and Design Optimization of PCM Embedded Heat Exchangers for the Built Environment

This research sheds light on the performance evaluation and design optimization of PCM-HXs for the built environment, addressing several barriers to practical issues to PCM-HX commercialization such as modeling aspects (i.e., modeling expertise and computational / time investment, etc.), manufacturing aspects (i.e., at-scale manufacturing, cost assessments, etc.) and experimental performance assessment (i.e., reliable experimental data, assessment of multiple PCM-working fluid combinations, etc.). We present a novel, comprehensive, and experimentally-validated design optimization framework for PCM-HXs capable of simulating any PCM-HX geometry with reasonable accuracy and significant computational time savings when compared to traditional CFD-based design practices. The framework was validated for a wide range of PCM-HX configurations, including a design optimization for a domestic hot water heater application where TES partially replaces electrical heating input. The resulting PCM-HXs were found to deliver 34-68% of the total daily hot water supply with only 5-10% package volume increase from the water heater, thus within U.S. DOE targets for TES systems. To identify the most promising HXs for PCM applications, first-order geometry and cost analyses were conducted based on off-the-shelf HX products. As part of this work, 9 PCM-HX prototypes were manufactured using additive and conventional manufacturing methods. Detailed economy-of-scale assessments were conducted for the most promising PCM-HXs and were found to have a good outlook for the next 5-10 years. The PCM-HX design optimization framework was validated through comprehensive in-house experimental testing using newly-developed PCM-to-fluid test facilities. In total,10 total in-house component-level experiments were conducted using these prototypes, including 9 with water and 1 with refrigerant (R410A) as the working fluid. It was found that the framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time without manual design changes, eliminating the need for time-consuming and expensive prototyping efforts as part of the design process. As part of this work, a publicly-available PCM web tool was released which includes a PCM property database (531 PCMs) and PCM-HX modeling tool to assist the design community on common PCM-HX use-cases, e.g., single/multiple flow path(s) fluid-to-PCM and air-to-fluid-to-PCM configurations (https://ceeeweb.umd.edu/pcmapp/). This work will accelerate the design and time to market for next generation PCM-HXs.

25 ENERGY STORAGE↗

Atomistic insights into the heat conductance across the interfaces between erythritol and different metals: A non-equilibrium molecular dynamics study

The heat conductance across the interface between a phase change material (PCM) and the metal shell is important for thermal design of latent heat storage systems. Non-equilibrium molecular dynamics simulations were carried out in this work to unravel, at the atomistic level, the interfacial heat conductance mechanisms between erythritol (the most promising medium-temperature polyol PCM) and two different metals (i.e., copper and aluminum). The interfacial contact ratio was introduced as a parameter to represent different contact conditions at the interfaces, for example, different surface roughness levels of the metals. It was found that with the increase of interfacial contact ratio, the temperature difference between the erythritol/metal interfaces decreases, whereas the interfacial heat transfer coefficient increases gradually. At the perfect contact condition, i.e., the interfacial contact ratio reaches 100%, the interfacial heat transfer coefficients across the erythritol/Cu and erythritol/Al interfaces were predicted to be 398 ± 26 MW/m 2 K and 544 ± 11 MW/m 2 K, respectively. The interfacial heat conductance of erythritol/Al is better than that of erythritol/Cu. The mismatch of atomic spectral density across the interfaces between erythritol and the two metals was analyzed and distinguished. These results could guide the selection of packaging materials and the thermal design of erythritol-based latent heat storage systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

High-Density, Low-Hysteresis Storage Using Hydrated Salts in Surface-Functionalized Hydrogels (Final Technical Report)

Nearly 70 years ago, Glauber’s salt was identified as a leading phase change material (PCM) in terms of its heat storage density (~2x paraffin), thermal conductivity (~1W/m·K), safety, availability and cost (~$\$$100/ton). However, the complex issues of supercooling and incongruent melting due to phase separation have prevented realization of the promise. The addition of thickeners and nucleating agents such as borax solve these issues but only over few cycles. This work aims to (a) resolve long-standing challenges with Glauber’s salt as a thermal storage material through a unique materials approach, (b) to characterize the new material’s properties that are relevant to performance and (c) to explore its incorporation into commercial water heaters. The materials concept involves encapsulating the salt in custom-designed, large-mesh hydrogels that enable breakthrough advances. Specifically, (1) the choice of mesh size and polymer chemistry control diffusion of salt/water and help to eliminate phase segregation. With the hydrogel itself occupying <10% volume, there is little loss in storage density compared to another encapsulation. (2) Specific nucleation centers that covalently tether to the hydrogel trigger heterogeneous nucleation, eliminating supercooling-associated hysteresis losses. The fact that they are spatially tethered, prevents the loss in performance over multiple freeze/thaw cycles (>100). We report extensive characterization of the hydrogel complex in terms of its storage density, freezing/melting temperature, cycling losses, rheological properties, aging and thermal conductivity. The novel material developed in this work is a significant advancement over the state-of-art. Finally, we investigate its potential as a thermal storage material for commercial/residential water heating and identify scenarios in which its deployment is advantageous.

25 ENERGY STORAGE↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Grid Impact of Oregon Offshore Wind [Slides]

This analysis used high-resolution offshore wind data and a detailed production cost model (PCM) of the Western Interconnection to explore the value and operational impact of integrating offshore wind along Oregon's coastline. Leveraging local technical stakeholder expertise and input, we determined a set of scenarios to explore. These scenarios vary both offshore wind capacities and the Western Interconnection generation and transmission infrastructure. From the scenario modeling and analysis, we identified the following key findings. In addition, we simulated a subset of the scenarios for a range of historical weather years (2007-2013), to understand the robustness of our findings to different weather conditions. Trans-coastal transmission constraints and congestion are the key drivers to the curtailment of Oregon offshore wind. Once power can be delivered into the Willamette Valley, there are few system constraints that lead to a significant curtailment of offshore wind off the coast of Oregon. Approximately 2.6 GW of installed offshore wind capacity can be integrated into Oregon's power system without major upgrades to trans-coastal transmission while avoiding significant curtailment. The system value provided by offshore wind ranges between $\$65$ /MWh and $\$85$ /MWh across the various scenarios considered. Offshore wind heavily influences the flow of the cross Cascade transmission. Across all scenarios, we found a robust relationship of approximately 500-550 MW decrease in the hourly flow of the cross Cascade transmission for every 1,000 MW of hourly offshore wind generation. However, we also found there was not a strong relationship between the highest cross-Cascade transmission flow hours and high offshore wind generation, limiting the extent to which offshore wind can be considered a non-wires alternative to cross cascade transmission. Depending on the meteorological year, 880-1,580 MW and 1,650-3,100 MW can be counted on to serve coastal loads with 2.6 GW and 5 GW of offshore wind capacity, respectively. Offshore wind allows for more optimal daily and hourly scheduling of hydropower, while still complying with various technical and regulatory constraints on the water resource. Oregon offshore wind has the potential to contribute to the evening net load peak in California (i.e., mitigate duck curve challenges), however transmission congestion between California and Oregon limits this contribution. Co-located storage at the point of interconnection for offshore wind reduces curtailment when trans-coastal transmission is not upgraded, providing a non-wires alternative to increase offshore wind capacity beyond 2.6 GW.

17 WIND ENERGY↗