Search NASA⌕ Search

SEARCH · Search NASA

Results for “PDMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Gadolinium silicide (Gd 5 Si 4 ) nanoparticles for tuneable broad band microwave absorption

We report that soft magnetic Gd 5 Si 4 nanoparticles exhibit excellent microwave absorption in the Ku-band (12.4-18 GHz) when dispersed in poly (dimethyl siloxane), PDMS. The minimum experimentally recorded reflection loss (RL) of Gd 5 Si 4 -PDMS nanocomposite is -69 dB, with a large bandwidth for a single 6 mm-thick layer. The bandwidth can be further extended by using a novel design where 1 mm-thick layers of the nanocomposite are arranged into a modified pyramid-shaped absorber. Standard electromagnetic (EM) simulations confirm experimental results.

36 MATERIALS SCIENCE↗

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

WE-AB-207B-03: A Computational Methodology for Determination of CTV-To-PTV Margins with Inter Fractional Shape Variations Based On a Statistical Point Distribution Model for Prostate Cancer Radiation Therapy

Purpose: Our assumption was that interfractional shape variations of target volumes could not be negligible for determination of clinical target volume (CTV)-to-planning target volume (PTV) margins. The aim of this study was to investigate this assumption as a simulation study by developing a computational framework of CTV-to-PTV margins with taking the interfractional shape variations into account based on point distribution model (PDM) Methods: The systematic and random errors for interfractional shape variations and translations of target volumes were evaluated for four types of CTV regions (only a prostate, a prostate plus proximal 1-cm seminal vesicles, a prostate plus proximal 2-cm seminal vesicles, and a prostate plus whole seminal vesicles). The CTV regions were delineated depending on prostate cancer risk groups on planning computed tomography (CT) and cone beam CT (CBCT) images of 73 fractions of 10 patients. The random and systematic errors for shape variations of CTV regions were derived from PDMs of CTV surfaces for all fractions of each patient. Systematic errors of shape variations of CTV regions were derived by comparing PDMs between planning CTV surfaces and average CTV surfaces. Finally, anisotropic CTV-to-PTV margins with shape variations in 6 directions (anterior, posterior, superior, inferior, right, and left) were computed by using a van Herk margin formula. Results: Differences between CTV-to-PTV margins with and without shape variations ranged from 0.7 to 1.7 mm in anterior direction, 1.0 to 2.8 mm in posterior direction, 0.8 to 2.8 mm in superior direction, 0.6 to 1.6 mm in inferior direction, 1.4 to 4.4 mm in right direction, and 1.3 to 5.2 mm in left direction. Conclusion: More than 1.0 mm additional margins were needed at least in 3 directions to guarantee CTV coverage due to shape variations. Therefore, shape variations should be taken into account for the determination of CTV-to-PTV margins.

60 APPLIED LIFE SCIENCES↗

Elastomeric microparticles for acoustic mediated bioseparations

Background: Acoustophoresis has been utilized successfully in applications including cell trapping, focusing, and purification. One current limitation of acoustophoresis for cell sorting is the reliance on the inherent physical properties of cells (e.g., compressibility, density) instead of selecting cells based upon biologically relevant surface presenting antigens. Introducing an acoustophoretic cell sorting approach that allows biochemical specificity may overcome this limitation, thus advancing the value of acoustophoresis approaches for both the basic research and clinical fields. Results: The results presented herein demonstrate the ability for negative acoustic contrast particles (NACPs) to specifically capture and transport positive acoustic contrast particles (PACPs) to the antinode of an ultrasound standing wave. Emulsification and post curing of pre-polymers, either polydimethylsiloxane (PDMS) or polyvinylmethylsiloxane (PVMS), within aqueous surfactant solution results in the formation of stable NACPs that focus onto pressure antinodes. We used either photochemical reactions with biotin-tetrafluorophenyl azide (biotin-TFPA) or end-functionalization of Pluronic F108 surfactant to biofunctionalize NACPs. These biotinylated NACPs bind specifically to streptavidin polystyrene microparticles (as cell surrogates) and transport them to the pressure antinode within an acoustofluidic chip. Conclusion: To the best of our knowledge, this is the first demonstration of using NACPs as carriers for transport of PACPs in an ultrasound standing wave. By using different silicones (i.e., PDMS, PVMS) and curing chemistries, we demonstrate versatility of silicone materials for NACPs and advance the understanding of useful approaches for preparing NACPs. This bioseparation scheme holds potential for applications requiring rapid, continuous separations such as sorting and analysis of cells and biomolecules.

59 BASIC BIOLOGICAL SCIENCES↗

Low Temperature Studies on DC745U Pressure Pads

DC745U is a silica-filled solid silicone elastomer used to manufacture pressure pads for a variety of applications. The material is proprietary to Dow Corning and thus very little information on its composition and properties is available. A considerable amount of characterization work has been conducted (Denisse Ortiz-Acosta W-1-TR-0098U/ LA-UR-12-23612) on DC745U. Based on these studies an estimate of the composition of the polymer was obtained. DC745U is composed of ≤ 100 wt% dimethyl siloxane repeat units, ≤1.5 wt% of methylphenyl siloxane, and ≤ 1 wt% methylvinyl siloxane groups. The methylvinyl siloxane groups are used as crosslink sites. The polymer is cured using a vinyl-specific peroxide, Varox DBPH-50, at 160ºC to form a polymer network. The structure and composition of this polymer network provide DC745U its unique properties. The methylphenyl siloxane repeat unit was added to improve DC745U’s thermal properties when compared to polydimethylsiloxane (PDMS). PDMS has a glass transition temperature of -120ºC and a melting temperature of -40ºC. It is believed that the phenyl group in DC745U improves thermal properties by inhibiting crystallization. This report describes the results obtained from low temperature thermal, mechanical and molecular characterization. These studies were conducted to improve our understanding of low temperature crystallization kinetics and thermal kinetics under compression strain and to determine if the pad undergoes stress deformations under these extreme conditions. Results described herein address several knowledge gaps previously stated in the report W-1-TR-0098U. Experiments described here include Differential Scanning Calorimetry (DSC), Dynamic Mechanical Analysis (DMA), Nuclear Magnetic Resonance (NMR), and mechanical (stress/strain) tests.

36 MATERIALS SCIENCE↗

Resolving and Measuring Diffusion in Complex Interfaces: Exploring New Capabilities

This exploratory LDRD targeted the use of a new high resolution spectroscopic diffusion capabilities developed at Sandia to resolve transport processes at interfaces in heterogeneous polymer materials. In particular, the combination of high resolution magic angle spinning (HRMAS) nuclear magnetic resonance (NMR) spectroscopy with pulsed field gradient (PFG) diffusion experiments were used to directly explore interface diffusion within heterogeneous polymer composites, including measuring diffusion for individual chemical species in multi-component mixtures. Several different types of heterogeneous polymer systems were studied using these HRMAS NMR diffusion capabilities to probe the resolution limitations, determine the spatial length scales involved, and explore the general applicability to specific heterogeneous systems. The investigations pursued included a) the direct measurement of the diffusion for poly(dimethyl siloxane) polymer (PDMS) on nano-porous materials, b) measurement of penetrant diffusion in additive manufactures (3D printed) processed PDMS composites, and c) the measurement of diffusion in swollen polymers/penetrant mixtures within nano-confined aluminum oxide membranes. The NMR diffusion results obtained were encouraging and allowed for an improved understanding of diffusion and transport processes at the molecular level, while at the same time demonstrating that the spatial heterogeneity that can be resolved using HRMAS NMR PFG diffusion experiment must be larger than ~μm length scales, expect for polymer transport within nanoporous carbons where additional chemical resolution improves the resolvable heterogeneous length scale to hundreds of nm.

36 MATERIALS SCIENCE↗

Physical Properties of Low-Molecular Weight Polydimethylsiloxane Fluids

Physical property measurements including viscosity, density, thermal conductivity, and heat capacity of low-molecular weight polydimethylsiloxane (PDMS) fluids were measured over a wide temperature range (-50°C to 150°C when possible). Properties of blends of 1 cSt and 20 cSt PDMS fluids were also investigated. Uncertainties in the measurements are cited. These measurements will provide greater fidelity predictions of environmental sensing device behavior in hot and cold environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single Pass Laser Process for Super-Hydrophobic Flexible Surfaces with Micro/Nano Hierarchical Structures

Wetting has been studied in various fields: chemical industry, automobile manufacturing, food companies, and even life sciences. In these studies, super-hydrophobic surfaces have been achieved through complex steps and processes. To realize super-hydrophobicity, however, we demonstrated a simple and single pass laser process for the fabrication of micro/nano hierarchical structures on the flexible polytetrafluoroethylene (PTFE, Teflon) surface. The fabricated hierarchical structures helped increase the hydrophobicity by augmenting the surface roughness and promoting air-trapping. In addition, we employed a low-cost and high-throughput replication process producing numerous polydimethylsiloxane (PDMS) replicas from the laser-processed PTFE film. Thanks to the anti-adhesive characteristics of PTFE and the elasticity of PDMS, the structure perfectly transferred to the replica without any mechanical failure. Moreover, our designed mesh patterns offered the possibility of large area applications through varying the process parameters (pitch, beam spot size, laser fluence, and scan speed). Even though mesh patterns had relatively large pitch (190 μm), we were able to achieve high contact angle (>150°). Through pneumatically deformed structure, we clearly showed that the shape of the droplets on our laser-processed super-hydrophobic surface was spherical. Based on these outcomes, we can expect our single laser pulse exposure process can overcome many drawbacks and offer opportunities for advancing applications of the wetting phenomena.

36 MATERIALS SCIENCE↗

Performance of Graphene/Polydimethylsiloxane Surfaces against S. aureus and P. aeruginosa Single- and Dual-Species Biofilms

The increasing incidence of implant-associated infections has prompted the development of effective strategies to prevent biofilm formation on these devices. In this work, pristine graphene nanoplatelet/polydimethylsiloxane (GNP/PDMS) surfaces containing different GNP loadings (1, 2, 3, 4, and 5 wt%) were produced and evaluated on their ability to mitigate biofilm development. After GNP loading optimization, the most promising surface was tested against single- and dual-species biofilms of Staphylococcus aureus and Pseudomonas aeruginosa. The antibiofilm activity of GNP/PDMS surfaces was determined by the quantification of total, viable, culturable, and viable but nonculturable (VBNC) cells, as well as by confocal laser scanning microscopy (CLSM). Results showed that 5 wt% GNP loading reduced the number of total (57%), viable (69%), culturable (55%), and VBNC cells (85%) of S. aureus biofilms compared to PDMS. A decrease of 25% in total cells and about 52% in viable, culturable, and VBNC cells was observed for P. aeruginosa biofilms. Dual-species biofilms demonstrated higher resistance to the antimicrobial activity of GNP surfaces, with lower biofilm cell reductions (of up to 29% when compared to single-species biofilms). Still, the effectiveness of these surfaces in suppressing single- and dual-species biofilm formation was confirmed by CLSM analysis, where a decrease in biofilm biovolume (83% for S. aureus biofilms and 42% for P. aeruginosa and dual-species biofilms) and thickness (on average 72%) was obtained. Overall, these results showed that pristine GNPs dispersed into the PDMS matrix were able to inhibit biofilm growth, being a starting point for the fabrication of novel surface coatings based on functionalized GNP/PDMS composites.

Oliveira, Isabel M.↗

Organosiloxane working fluids for the liquid droplet radiator

Siloxane-based working fluids for advanced space radiators requiring direct fluid exposure to the space environment are evaluated. Isolation of five candidate fluids by vacuum distillation from existing siloxane polymers is discussed. The five fluids recovered include a polydimethylsiloxane, three phenyl-containing siloxanes, and a methylhexylsiloxane. Vapor pressures and viscosities for the five fluids are reported over the temperature range of 250 to 400 K. Use of thermal-gravimetric analysis to reliably estimate vapor pressures of 10 to the -8 power Pascals is described. Polydimethylsiloxane (PDMS) and polymethylphenylsiloxane (PMPS) are selected from the five candidate fluids based on favorable vapor pressure and viscosity, as well as perceived stability in low-Earth orbit environments. Characterization of these fluids by infrared spectroscopy, Si-29 NMR, gel-permeation chromatography, and liquid chromatography is presented. Both fluids consist of narrow molecular weight distributions, with average molecular weights of about 2500 for PDMS and 1300 for PMPS.

Buch, R. R.↗

CO2 Acquisition Membrane (CAM)

The objective of CAM is to develop, test, and analyze thin film membrane materials for separation and purification of carbon dioxide (CO2) from mixtures of gases, such as those found in the Martian atmosphere. The membranes are targeted toward In Situ Resource Utilization (ISRU) applications that will operate in extraterrestrial environments and support future unmanned and human space missions. A primary application is the Sabatier Electrolysis process that uses Mars atmosphere CO2 as raw material for producing water, oxygen, and methane for rocket fuel and habitat support. Other applications include use as an inlet filter to collect and concentrate Mars atmospheric argon and nitrogen gases for habitat pressurization, and to remove CO2 from breathing gases in Closed Environment Life Support Systems (CELSS). CAM membrane materials include crystalline faujasite (FAU) zeolite and rubbery polymers such as silicone rubber (PDMS) that have been shown in the literature and via molecular simulation to favor adsorption and permeation of CO2 over nitrogen and argon. Pure gas permeation tests using commercial PDMS membranes have shown that both CO2 permeance and the separation factor relative to other gases increase as the temperature decreases, and low (Delta)P(Sub CO2) favors higher separation factors. The ideal CO2/N2 separation factor increases from 7.5 to 17.5 as temperature decreases from 22 C to -30 C. For gas mixtures containing CO2, N2, and Ar, plasticization decreased the separation factors from 4.5 to 6 over the same temperature range. We currently synthesize and test our own Na(+) FAU zeolite membranes using standard formulations and secondary growth methods on porous alumina. Preliminary tests with a Na(+) FAU membrane at 22 C show a He/SF6 ideal separation factor of 62, exceeding the Knudsen diffusion selectivity by an order of magnitude. This shows that the membrane is relatively free from large defects and associated non-selective (viscous flow) transport mechanisms. The Membrane Test Facility (MTF) has been developed to measure membrane permeance over a wide range of temperature and pressure. The facility uses two volume compartments separated by the membrane that are instrumented to measure temperature, delta pressure across the membrane, and gas composition. A thermal shroud supports and encloses the membrane, and provides temperature control. Methods were developed to determine membrane permeance using the first order decay of the pressure difference between the sealed compartments, using the total pressure for pure gases, and partial pressure of each species in gas mixtures. The technique provides an end-to-end measurement of gas permeance that includes concentration polarization effects. Experiments have shown that in addition to membrane permeance properties, the geometry and design of associated structures play an important role in how membrane systems will function on Mars.

Mason, Larry W.↗

Dielectric relaxation behavior of poly(acrylonitri1e-co-methacrylonitrile) microcapsules dispersed in a silicone matrix

The dielectric relaxation behavior of poly(acry1onitrile-co-methacrylonitrile) dispersed in a cured polydimethyl siloxane (PDMS) matrix as microcapsules was investigated over multiple thermal cycles and at varying concentrations. The copolymer microcapsules contained an isopentane core. In the PDMS matrix this copolymer displayed a pronounced relaxation signal at temperatures above the glass transition of the copolymers due to Maxwell-Wagner-Sillars (MWS) relaxation. The mechanism of MWS relaxation interpreted by the Havriliak-Negami and Kohlrausch-Williams-Watts relaxation functions was found to be very similar to previous studies of neat polyacrylonitrile and its copolymer. The activation energy of the relaxation decreased over successive thermal cycling coincident with a decreasing strength of the relaxation. These observations were attributed to the decreasing concentration of nitrile groups due to intramolecular cyclizations.

Park, Taigyoo↗

Dielectric Relaxation Behavior of Poly(acrylonitrile-co-methacrylonitrile) Microcapsules Dispersed in a Silicone Matrix

The dielectric relaxation behavior of poly(acrylonitrile-co-methacrylonitrile) dispersed in a cured polydimethyl siloxane (PDMS) matrix as microcapsules was investigated over multiple thermal cycles and at varying concentrations. The copolymer microcapsules contained an isopentane core. In the PDMS matrix this copolymer displayed a pronounced relaxation signal at temperatures above the glass transition of the copolymers due to Maxwell-Wagner-Sillars (MWS) relaxation. The mechanism of MWS relaxation interpreted by the Havriliak-Negami and Kohlrausch-Williams-Watts relaxation functions was found to be very similar to previous studies of neat polyacrylonitrile and its copolymer. The activation energy of the relaxation decreased over successive thermal cycling coincident with a decreasing strength of the relaxation. These observations were attributed to the decreasing concentration of nitrile groups due to intramolecular cyclizations.

Park, Taigyoo↗

Fabricating PFPE Membranes for Microfluidic Valves and Pumps

A process has been developed for fabricating membranes of a perfluoropolyether (PFPE) and integrating them into valves and pumps in laboratory-on-achip microfluidic devices. Membranes of poly(tetrafluoroethylene) [PTFE] and poly(dimethylsilane) [PDMS] have been considered for this purpose and found wanting. By making it possible to use PFPE instead of PTFE or PDMS, the present process expands the array of options for further development of microfluidic devices for diverse applications that could include detection of biochemicals of interest, detection of toxins and biowarfare agents, synthesis and analysis of proteins, medical diagnosis, and synthesis of fuels.

Greer, Frank↗

Silicone-Rubber Microvalves Actuated by Paraffin

Microvalves containing silicone-rubber seals actuated by heating and cooling of paraffin have been proposed for development as integral components of microfluidic systems. In comparison with other microvalves actuated by various means (electrostatic, electromagnetic, piezoelectric, pneumatic, and others), the proposed valves (1) would contain simpler structures that could be fabricated at lower cost and (2) could be actuated by simpler (and thus less expensive) control systems. Each valve according to the proposal would include a flow channel bounded on one side by a flat surface and on the other side by a curved surface defined by an arched-cross-section, elastic seal made of silicone rubber [polydimethylsilane (PDMS)]. The seal would be sized and shaped so that the elasticity of the PDMS would hold the channel open except when the seal was pressed down onto the flat surface to close the channel. The principle of actuation would exploit the fact that upon melting or freezing, the volume of a typical paraffin increases or decreases, respectively, by about 15 percent. In a valve according to the proposal, the seal face opposite that of the channel would be in contact with a piston-like plug of paraffin. In the case of a valve designed to be normally open at ambient temperature, one would use a paraffin having a melting temperature above ambient. The seal would be pushed against the flat surface to close the channel by heating the paraffin above its melting temperature. In the case of a valve designed to be normally closed at ambient temperature, one would use a paraffin having a melting temperature below ambient. The seal would be allowed to spring away from the flat surface to open the channel by cooling the paraffin below its melting temperature. The availability of paraffins that have melting temperatures from 70 to +80 C should make it possible to develop a variety of normally closed and normally open valves. The figure depicts examples of prototype normally open and normally closed valves according to the proposal. In each valve, an arch cross section defining a channel having dimensions of the order of tens of micrometers would be formed in a silicone-rubber sheet about 40 m thick. The silicone rubber sheet would be hermetically sealed to a lower glass plate that would define the sealing surface and to an upper glass plate containing a well. The well would be filled with paraffin and capped with a rigid restraining layer of epoxy. In the normally open valve, the paraffin would have a melting temperature above ambient (e.g., 40 C) and the wall of the well would be coated with a layer of titanium that would serve as an electric heater. In the normally closed valve, the paraffin would have a melting temperature below ambient (e.g.-5 C). Instead of a heater in the well, the normally closed valve would include a thermoelectric cooler on top of the epoxy cap.

Svelha, Danielle↗

Design and Delivery of a Filter for Removal of Siloxanes from the ISS Atmosphere

Dimethylsilanediol (DMSD) has been identified as a problematic chemical contaminant aboard ISS. This contaminant was initially identified in the ISS condensate and in the Water Processor Assembly (WPA) product water in 2010 when an increasing total organic carbon (TOC) trend was detected in the water produced by the WPA. DMSD is not a crew health hazard at the levels observed in the product water, but it may degrade the performance of the Oxygen Generation System (OGS) which uses product produced by the WPA for electrolysis. In addition, DMSD can prevent the effective operation of the WPA catalytic reactor, and necessitates early replacement of Multifiltration Beds in the WPA. An investigation into the source of DMSD has determined that polydimethylsiloxanes (PDMSs) are hydrolyzing in the Condensing Heat Exchanger (CHX) to form DMSD. PDMSs are prevalent aboard ISS from a variety of sources, including crew hygiene products, adhesives, caulks, lubricants, and various nonmetallics. TPDMSs are also implicated in CHX hydrophilic coating degradation, rendering it hydrophobic and adversely affecting its ability to effectively transmit water to the condensate bus. Eventually this loss in performance results in water droplets in the air flow out of the CHX core, which can lead to microbial growth in the air ducts and can impact the performance of downstream systems. Design concepts have now been developed for removing PDMS in the air stream before it can reach the CHX core, thus preventing degradation of the coating and decomposition of the PDMS to DMSD. This paper summarizes the current status of the effort to deliver filters to ISS for removing PDMSs from the atmosphere before they can adversely impact the performance of the CHX coating and the WPA.

Carter, Layne↗

Tunable Piezoelectricity of Multifunctional Boron Nitride Nanotube/Poly(dimethylsiloxane) Stretchable Composites

Boron nitride nanotubes (BNNT) uniformly dispersed in stretchable materials, such as poly(dimethylsiloxane) (PDMS), could create the next generation of composites with augmented mechanical, thermal, and piezoelectric characteristics. This work reports tunable piezoelectricity of multifunctional BNNT/PDMS stretchable composites prepared via co-solvent blending with tetrahydrofuran (THF) to disperse BNNTs in PDMS while avoiding sonication or functionalization. The resultant stretchable BNNT/PDMS composites demonstrate augmented Young’s modulus (200% increase at 9 wt% BNNT) and thermal conductivity (120% increase at 9 wt% BNNT) without losing stretchability. Further-more, BNNT/PDMS composites demonstrate piezoelectric responses that are linearly proportional to BNNT wt%, achieving a piezoelectric constant (|d33|) of 18 pmV−1 at 9 wt% BNNT without poling, which is competitive with commercial piezoelectric polymers. Uniquely, BNNT/PDMS accommodates tensile strains up to 60% without plastic deformation by aligning BNNTs, which enhances the composites’ piezoelectric response approximately five times. Finally, the combined stretchable and piezoelectric nature of the composite was exploited to produce a vibration sensor sensitive to low-frequency (≈1 kHz) excitation. This is the first demonstration of multifunctional, stretchable BNNT/PDMS composites with enhanced mechanical strength and thermal conductivity and furthermore tunable piezoelectric response by varying BNNT wt% and applied strain, permitting applications in soft actuators and vibration sensors.

Boron Nitride Nanotubes, Polydimethylsiloxane, Pie↗

CLARREO Pathfinder as a SI-traceable Reference for Satellite Intercalibration

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) consists of an Earthviewing reflected solar (RS) spectrometer that will measure the Earth-reflected solar radiation from International Space Station with an SI-traceable radiometric uncertainty of 0.3% (1-sigma). The high-accuracy CPF measurements will provide an in-orbit reference for intercalibrating other spaceflight RS instruments. The CPF intercalibration team has been tasked to develop a state-of-the-art approach to calibrate the shortwave channel (300-5000 nm) of the Clouds and the Earth’s Radiant Energy System (CERES) instrument and the reflective solar bands (RSB) of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, both onboard the NOAA-20 satellite, against the CPF benchmark measurements. The aimed intercalibration methodology uncertainty for both the target instruments is also 0.3%. To meet this stringent intercalibration accuracy, the CPF team has developed methods for mitigating the impacts of spatial, spectral, and angular differences between the intercalibration footprints from the CPF and target instruments. To further alleviate uncertainty, the CPF team will employ Polarization Distribution Models (PDMs) to characterize the polarization state of the Earth-reflected radiance as a function of the intercalibration footprint scene type, solar and viewing geometry, and wavelength. The PDMs will assist in identifying low-polarized scene radiances for meticulously intercalibrating the polarization sensitive VIIRS instrument against the significantly-less polarization-sensitive CPF instrument. This paper will highlight the CPF mission overview, the details of the CPF intercalibration approach, and additional outcomes of the CPF intercalibration studies that may benefit the broader remote sensing community.community.

Hyperspectral↗