Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ghost imaging of phase objects with classical incoherent light

We describe an optical setup for performing spatial Fourier filtering in ghost imaging with classical incoherent light. This is achieved by a modification of the conventional geometry for lensless ghost imaging. It is shown on the basis of classical coherence theory that with this technique one can realize what we call phase-contrast ghost imaging to visualize pure phase objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

What a difference a delay makes! CT urogram: a pictorial essay

Purpose: The aim of this pictorial essay is to demonstrate several cases where the diagnosis would have been difficult or impossible without the excretory phase image of CT urography. Methods: A brief discussion of CT urography technique and dose reduction is followed by several cases illustrating the utility of CT urography. Results: CT urography has become the primary imaging modality for evaluation of hematuria, as well as in the staging and surveillance of urinary tract malignancies. CT urography includes a non-contrast phase and contrast-enhanced nephrographic and excretory (delayed) phases. While the three phases add to the diagnostic ability of CT urography, it also adds potential patient radiation dose. Several techniques including automatic exposure control, iterative reconstruction algorithms, higher noise tolerance, and split-bolus have been successfully used to mitigate dose. The excretory phase is timed such that the excreted contrast opacifies the urinary collecting system and allows for greater detection of filling defects or other abnormalities. Sixteen cases illustrating the utility of excretory phase imaging are reviewed. Conclusions: Excretory phase imaging of CT urography can be an essential tool for detecting and appropriately characterizing urinary tract malignancies, renal papillary and medullary abnormalities, CT radiolucent stones, congenital abnormalities, certain chronic inflammatory conditions, and perinephric collections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray phase contrast imaging: Transmission functions separable in cylindrical coordinates

A Fresnel-Kirchhoff integral can be used to calculate x-ray phase contrast images when the transmission function is known. Here expressions for image intensity are derived for objects with axial symmetry for an x-ray source with non-vanishing dimensions. An expression for the image intensity is given for an x-ray source whose intensity distribution is described by a Gaussian function, from which an expression for the limiting case of a point source of radiation is found. The expressions for image intensity are evaluated for cases where the magnification is substantially greater than one, as would be employed in biological imaging. Experiments using a microfocus x-ray tube and charge coupled device camera are reported to determine the capability of the method for imaging small spherical objects, such as gold particles, which might find application as contrast agents in biomedical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid HIFU autofocusing using the entire MR-ARFI image

Phase aberrations and attenuations caused by bone can defocus HIFU in the brain and organs behind the ribcage. To refocus the beam, MR-ARFI can be used to measure tissue displacements created by each element in the transducer, and optimize driving signal delays and amplitudes. We introduce a new MR-ARFI-based autofocusing method that requires many fewer image acquisitions than current methods. The method is validated in simulations of bone and brain HIFU transducers, and compared to a conventional method.

60 APPLIED LIFE SCIENCES↗

Piezoresponse and magnetic properties of multiferroic (1−x)Bi{sub 0.9}Dy{sub 0.1}FeO{sub 3}–xPbTiO{sub 3} solid solution

The multiferroic solid solution of (1−x)[0.9BiFeO{sub 3}–0.1DyFeO{sub 3}]–xPbTiO{sub 3} with compositions around the morphotropic phase boundary has been synthesized in the form of ceramics and characterized by Piezoresponse Force Microscope (PFM) and Superconducting Quantum Interference Device. Both the original local polar domain structure and the domain evolution after poling have been studied by PFM. The PFM phase imaging has revealed some interesting details of poling and domain switching process: The out-of-plane phase image shows a uniform direction of polarization along the applied electric field, while the in-plane phase image indicates two kinds of domains with antiparallel polarizations. This kind of poled domain structure is explained based on the orientations of the polarization as permitted by the rhombohedral crystal symmetry in grains of different crystallographic orientations. The magnetic properties measured within the temperature range from 1.8 K to 300 K reveal an interesting sequence of magnetic transitions from a weakly ferromagnetic order (WFM{sub 1}) to an antiferromagnetic state (AFM), and then to another weak ferromagnetic phase (WFM{sub 2}), upon cooling. A preliminary magnetic phase diagram is proposed for BDF-34PT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Size estimates of Titan's aerosols based on Voyager high-phase-angle images

Limits on the physical properties of the scattering haze near the top of Titan's atmosphere are derived from data obtained from seven high-phase-angle images from Voyager 1 and 2. From the ratio of the intensities observed at two different high phase angles, an estimate can be made of the forward-scattering lobe of the single-scattering phase function. Comparing the forward-scattering estimate with diffraction lobes from particles of different radii, it is concluded that the average radius of the particles found in the upper few tenths of an optical depth exceeds 0.19 micron. Judging from data observed at four different phase angles, the haze particles probably have a refractive index near 1.6 and a mean size of about 0.5 micron, if the widths of their diffraction peaks are close to those for equal-volume spheres. However, the highly polarizing nature of the particles over a broad wavelength-bandpass (Tomasko and Smith, 1982; West et al, 1983) combined with their forward-scattering behavior makes it very unlikely that the particles are spherical. The nonsphericity contributes to the uncertainty about the radii of the particles, but it is thought that the average radius is several tenths of a micron.

Rages, K.↗

Phase-Contrast Imaging of Nanostructures with Incoherent Femtosecond Laser Driven Soft X-Ray Source

Application of polychromatic (1.5-15 nm) soft X-ray emission of a spatially large (>0.1 mm) bright femtosecond laser driven plasma source for propagation based phase contrast imaging of nanometer thick foils and biological samples is considered. Diffraction and phase contrast effects increased quality and contrast of the experimental images, registered by LiF crystal X-ray detector with submicron resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Melting temperature of bismuth to 55 GPa using synchrotron X-ray phase contrast imaging

The melting temperature of elemental bismuth under high pressure has been measured to 55 GPa using synchrotron X-ray phase-contrast imaging in the laser-heated diamond anvil cell. Imaging of solid-liquid interface formation, combined with radiometric temperature and X-ray diffraction measurements, reveals a pronounced reduction in melting boundary slope in Bi-V with pressure. The unusually steep initial slope is attributed to low configurational entropy of melting, arising from structural ordering and coordination matching in the cool liquid, while slope reduction is driven by entropy increase correlated with significant liquid structure changes with rising pressure and temperature. Finally, the data rule out kinetic effects on melting in shock compression experiments and demonstrate the need for improved theoretical phase diagrams.

Materials science↗

The structure of dodecagonal (Ta,V){sub 1.6}Te imaged by phase-contrast scanning transmission electron microscopy

While HRTEM is the well-established method to characterize the structure of dodecagonal tantalum (vanadium) telluride quasicrystals and their periodic approximants, phase-contrast imaging performed on an aberration-corrected scanning transmission electron microscope (STEM) represents a favorable alternative. The (Ta,V){sub 151}Te{sub 74} clusters, the basic structural unit in all these phases, can be visualized with high resolution. A dependence of the image contrast on defocus and specimen thickness has been observed. In thin areas, the projected crystal potential is basically imaged with either dark or bright contrast at two defocus values close to Scherzer defocus as confirmed by image simulations utilizing the principle of reciprocity. Models for square-triangle tilings describing the arrangement of the basic clusters can be derived from such images. - Graphical abstract: PC-STEM image of a (Ta,V){sub 151}Te{sub 74} cluster. Highlights: Black-Right-Pointing-Pointer C{sub s}-corrected STEM is applied for the characterization of dodecagonal quasicrystals. Black-Right-Pointing-Pointer The projected potential of the structure is mirrored in the images. Black-Right-Pointing-Pointer Phase-contrast STEM imaging depends on defocus and thickness. Black-Right-Pointing-Pointer For simulations of phase-contrast STEM images, the reciprocity theorem is applicable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Interactive 4D-STEM Phase-Contrast Imaging From Electron Event Representation Data: Less computation with the right representation

The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.

4D-STEM↗

Double sided grating fabrication for high energy X-ray phase contrast imaging

State of the art grating fabrication currently limits the maximum source energy that can be used in lab based x-ray phase contrast imaging (XPCI) systems. In order to move to higher source energies, and image high density materials or image through encapsulating barriers, new grating fabrication methods are needed. In this work we have analyzed a new modality for grating fabrication that involves precision alignment of etched gratings on both sides of a substrate, effectively doubling the thickness of the grating. Furthermore, we have achieved a front-to-backside feature alignment accuracy of 0.5 µm demonstrating a methodology that can be applied to any grating fabrication approach extending the attainable aspect ratios allowing higher energy lab based XPCI systems.

36 MATERIALS SCIENCE↗

Simultaneous 8.2 keV phase-contrast imaging and 24.6 keV X-ray diffraction from shock-compressed matter at the LCLS

In this paper, we demonstrate simultaneous phase-contrast imaging (PCI) and X-ray diffraction from shock compressed matter at the Matter in Extreme Conditions endstation, at the Linac Coherent Light Source (LCLS). We utilize the chromaticity from compound refractive X-ray lenses to focus the 24.6 keV 3rd order undulator harmonic of the LCLS to a spot size of 5 μm on target to perform X-ray diffraction. Simultaneous PCI from the 8.2 keV fundamental X-ray beam is used to visualize and measure the transient properties of the shock wave over a 500 μm field of view. Furthermore, we demonstrate the ability to extend the reciprocal space measurements by 5 Å –1 , relative to the fundamental X-ray energy, by utilizing X-ray diffraction from the 3rd harmonic of the LCLS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase contrast imaging measurements of reversed shear Alfven eigenmodes during sawteeth in Alcator C-Mod

Reversed shear Alfven eigenmodes (RSAEs) have been observed with the phase contrast imaging diagnostic and Mirnov coils during the sawtooth cycle in Alcator C-mod [M. Greenwald et al., Nucl. Fusion 45, S109 (2005)] plasmas with minority ion-cyclotron resonance heating. Both down-chirping RSAEs and up-chirping RSAEs have been observed during the sawtooth cycle. Experimental measurements of the spatial structure of the RSAEs are compared to theoretical models based on the code NOVA[C. Z. Cheng and M. S. Chance, J. Comput. Phys. 71, 124 (1987)] and used to derive constraints on the q profile. It is shown that the observed RSAEs can be understood by assuming a reversed shear q profile (up chirping) or a q profile with a local maximum (down chirping) with q{approx_equal}1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Mode Converted Ion Cyclotron Wave with Phase Contrast Imaging in Alcator C-Mod and Comparisons with Synthetic PCI Simulations in TORIC

Mode converted ion cyclotron wave (ICW) has been observed with phase contrast imaging (PCI) in D-{sup 3}He plasmas in Alcator C-Mod. The measurements were carried out with the optical heterodyne technique using acousto-optic modulators which modulate the CO2 laser beam intensity near the ion cyclotron frequency. With recently improved calibration of the PCI system using a calibrated sound wave source, the measurements have been compared with the full-wave code TORIC, as interpreted by a synthetic diagnostic. Because of the line-integrated nature of the PCI signal, the predictions are sensitive to the exact wave field pattern. The simulations are found to be in qualitative agreement with the measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Phase Contrast Imaging (XPCI) System

Sandia National Laboratories (Sandia) and Carestream Health, Inc. (CHI) collaborated on the development of a grating-based X-ray Phase Contrast Imaging (XPCI) system at Sandia. The purpose of the agreement was to share research and development knowledge, resources, and capabilities in the advancement of XPCI that would be mutually beneficial to CHI and Sandia. In the course of this agreement Sandia designed and built an XPCI apparatus including opto-mechanical design, source and x-ray detector selection, software interface, hardware assembly, and system alignment. Data acquisition and image reconstruction were demonstrated at both CHI and Sandia. XPCI is a new imaging modality that enables non-destructive inspection of low density materials not previously possible with conventional x-ray. The technique fills a capability gap valuable to both the industry partner in their technical portfolio and in national security applications important to Sandia and the DOE mission space.

47 OTHER INSTRUMENTATION↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗

Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗