Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOMULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Absolute ultraviolet spectrophotometry of: alpha CMa, gamma Ori, kappa Ori, and alpha Leo; and a continuing calibration program and some preliminary results

Spectral observations of the stars alpha CMa, gamma Ori, kappa Ori, and alpha Leo have been obtained in the range 1150 to 4000 Angstroms, using rocket borne spectrometers. The payloads have a 13-inch diameter telescope, a rotatable concave diffraction grating, and three pulse counting photomultiplier photometers. The laboratory standards used as photometric references derive their primary calibration directly or indirectly from the National Bureau of Standards. An error range of up to + or - 10 percent is attributed to these laboratory standards; + or - 8 percent to the calibration procedure; and + or - 10 percent is assigned as an accidental error range.

Evans, D. C.↗

Radiation noise in a high sensitivity star sensor

An extremely accurate attitude determination was developed for space applications. This system uses a high sensitivity star sensor in which the photomultiplier tube is subject to noise generated by space radiations. The space radiation induced noise arises from trapped electrons, solar protons and other ionizing radiations, as well as from dim star background. The solar activity and hence the electron and proton environments are predicted through the end of the twentieth century. The available data for the response of the phototube to proton, electron, gamma ray, and bremsstrahlung radiations are reviewed and new experimental data is presented. A simulation was developed which represents the characteristics of the effect of radiations on the star sensor, including the non-stationarity of the backgrounds.

Parkinson, J. B.↗

The Fraunhofer line discriminator: An airborne fluorometer

An experimental Fraunhofer Line Discriminator (FLD) can differentiate and measure solar-stimulated luminescence when viewed against a background of reflected light. Key elements are two extremely sensitive photomultipliers, two glass-spaced Fabry-Perot filters having a bandwidth less than 1 A, and an analog computer. As in conventional fluorometers, concentration of a fluorescent substance is measured by comparison with standards. Quantitative use is probably accurate only at low altitudes but detection of luminescent substances should be possible from any altitude. Applications of the present FLD include remote sensing of fluorescent dyes used in studies of current dynamics. The basic technique is applicable to detection of oil spills, monitoring of pollutants, and sensing over land areas.

Stoertz, G. E.↗

Development of a tape transport bacterial detection system

The feasibility of a tape transport chemiluminescence system for bacterial monitoring of regenerated water was demonstrated using a manually operated laboratory breadboard. The principle of detection is based on measuring the increase in chemiluminescence produced by the catalytic action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are distinguished from nonviable by comparing the signals of incubated and unincubated water samples. Using optimized protocols, sensitivities were obtained with 400 ml suspensions of E. coli and Cl. sporogenes. The sensitivity of the unincubated cycle E. coli (aerobe) was found to be 30 to 35 cells/m1, and that of the Cl. sporogenes (anaerobe) was 1000 to 10,000 cells/m1. The lower sensitivity toward Cl. sporogenes is attributed to several factors, namely the lower cytochrome content, the tendency to sporulate, long lag periods and the lower growth rate of Clostridia in general. The operational procedures used for processing the incubated and unincubated samples involved the following sequence: (1) concentrating the sample by filtration through a membrane filter, (2) washing with Dextrose-Thioglycollate Broth (3) incubating (0 to 4 hrs as required), (4) washing with 4M Urea, and (5) reacting with reagent in front of a photomultiplier tube. The signal output was recorded on a strip chart recorder.

Witz, S.↗

Apollo 15 laser altimeter, part D

The laser altimeter, consisting of a Q switched ruby laser, transmitting optics, counting timer, receiving optics, and a photomultiplier is described. Harmonic analysis of the mission data is also presented.

Robertson, F. L.↗

Modification of codes NUALGAM and BREMRAD, Volume 1

The NUGAM2 code predicts forward and backward angular energy differential and integrated distributions for gamma photons and fluorescent radiation emerging from finite laminar transport media. It determines buildup and albedo data for scientific research and engineering purposes; it also predicts the emission characteristics of finite radioisotope sources. The results are shown to be in very good agreement with available published data. The code predicts data for many situations in which no published data is available in the energy range up to 5 MeV. The NUGAM3 code predicts the pulse height response of inorganic (NaI and CsI) scintillation detectors to gamma photons. Because it allows the scintillator to be clad and mounted on a photomultiplier as in the experimental or industrial application, it is a more practical and thus useful code than others previously reported. Results are in excellent agreement with published Monte Carlo and experimental data in the energy range up to 4.5 MeV.

Steyn, J. J.↗

Radiative transfer effects behind reflected shock waves

Theoretical studies are reported which were largely centered on the nonequilibrium coupling of collisional, ionization, and radiative transfer processes behind reflected shock waves in nitrogen. Experimental studies included broad-band photomultiplier radiative intensity measurements, luminosity photographs of the reflected shock wave front, end-wall heat transfer measurements, and reflected shock velocity time-history measurements. The results of these activities are summarized, and comparisons between the theoretical and experimental results are discussed.

Nerem, R. M.↗

Functional characteristics of the OGO main body airglow photometer

The OGO-4 main body airglow photometer used a trialkali cathode photomultiplier to sense light at selected wavelengths between 2500 and 6300A corresponding to important emissions in the aurora and night airglow at emission rates ranging from a few rayleighs to about 200 kilorayleighs. The optical, electronic, and mechanical systems are described in terms of their functional characteristics.

Reed, E. I.↗

Advanced technical developments in support of scientific experiments in space

A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.

Lamport, J. E.↗

Light-detection electronics for a Raman lidar

A light-detection system for an optical radar, or lidar, unit to be used for remote temperature and composition measurements was designed, built, and bench tested. This detection system processes three return signal wavelengths: two Raman wavelengths, and the Rayleigh-Mie wavelength at 694.3 nanometers. Means of coping with photomultiplier tube instabilities and limitations are discussed. Circuits for gain control, ranging, and digitizing are included. The phototube gains can be switched fully on in 80 meters (450 nsec) or off in 30 meters (200 nsec) of range. The range circuit processes signals from 0.1 to 2 kilometers, with an estimated range resolution of less than 5 meters.

Leser, R. J.↗

The temporal characteristics of the terrestrial radiation belt

The terrestrial radiation belt effects on the detectors in the Wisconsin equipment are considered. The lowest dark count rate observed in orbit, compared with that measured in the thermal vacuum test on the ground, shows no measurable difference for the solar blind ASCOP 541-F photomultiplier tubes while the EMI-6256B tubes show an increase in minimum dark count of a factor of from 20 to 150 times that observed on the ground. All instruments are perturbed when in the South Atlantic anomaly, but the EMI tubes are by far the most sensitive to it. Indeed, the effect never goes away.

Mcnall, J. F.↗

Absolute ultraviolet spectrophotometry of Alpha Canis Majoris, Gamma Orionis, Kappa Orionis and Alpha Leonis

Spectral observations of the stars Alpha Canis Majoris, Gamma Orionis, Kappa Orionis and Alpha Leonis have been obtained in the range 1150-4000 A, using rocket borne spectrometers. The payloads have a 13-inch diameter telescope, a rotatable concave diffraction grating, and three pulse counting photomultiplier photometers. The observations are systematically lower than those of Carruthers (1968) at 1270 A, of Smith (1967) at 1376 A, and of Campbell (1970) at 2150 and 2550 A. The data are also about 15 percent lower than the ground-based photometry reported by Schild, Peterson and Oke (1971). The OAO-2 short wavelength scanner calibration agrees with the alpha Leo observations, but disagrees for Kappa Ori and Gamma Ori.

Evans, D. C.↗

Supernovae studied with a ground level atmospheric fluorescence

A monitoring experiment was undertaken late 1968 to search for photon bursts of extraterrestrial origin. The experiment and the results of the observations to date are summarized. The method of detection employs ground-based photomultiplier tubes which are sensitive to the secondary fluorescence light that would be produced when the primary pulse is absorbed in the atmosphere.

Bertsch, D. L.↗

Fabry lens.

Discussion of the properties, operation, and applications of the Fabry lens. As used in stellar photometry, a Fabry lens is nothing more than a simple converging lens inserted into the optical train of a photometer to construct an image of the objective on the photomultiplier cathode. The thereby derived advantages are reviewed, and some techniques designed to maximize these advantages are outlined.

Michlovic, J.↗

Electronic systems for the new multichannel spectrometer at Sacramento Peak.

Description of the design features and operation of a new multichannel solar spectrometer to be used for ground-based observations of active regions whose X-ray and EUV emissions are studied by the OSO-H and other satellites. The electronic systems associated with the instrument include (1) an electrooptical guider controlled by a punched paper tape capable of making raster scans of selected portions of the solar disk, (2) a programmer unit that applies paper-tape commands to various portions of the instrument, (3) a closed-loop servosystem for the vacuum heliostat, (4) stepping motor controls for spectral scans, (5) a 40-channel photomultiplier readout, and (6) a magnetometer. Preliminary solar observations indicate satisfactory performance of the system.

Hobbs, R. W.↗

Single photon detection and timing in the Lunar Laser Ranging Experiment.

The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

Poultney, S. K.↗

Laser Doppler anemometer for water tunnel applications.

A laser Doppler anemometer for three-dimensional velocity measurement in liquids and gases under a wide range of laboratory conditions has been developed. The instrument is particularly well suited for water tunnel applications. It is portable, easily aligned, and inexpensive (excluding electronic units). It operates in backscatter or forward scatter mode. In both cases all optical components, including laser and photomultiplier, remain on a common base. The system has built-in traversing capability and an aiming device for visualizing the focal (test) point. Design details and representative velocity measurements are given.

Bossel, H. H.↗