Synchrophasor Data Anomaly Detection on Grid Edge by 5G Communication and Adjacent Compute

The fifth-generation mobile communication (5G) technology offers the opportunities to enhance the grid real-time monitoring. The 5G-enabled phasor measurement units (PMUs) features flexible positioning and cost-effective long-term maintenance, without constraints of fixing wire. This paper is the first to demonstrate the applicability of 5G in PMU communication, and the experiment was carried out at Verizon non-standalone testbed at Pacific Northwest National Laboratory (PNNL) Advanced Wireless Communication lab. The performance of 5G-enabled PMU communication setup is reviewed and discussed in this paper, and the paper presents a real-time dynamic linear model (DML) based synchrophasor data anomaly detection application. Last but not least, the practicability of implementing 5G for wide-area protection strategies is explored and discussed by analyzing the experimental results.

5G, Synchrophasor data, machine learning, anomaly ↗

Self-Healing Attack-Resilient PMU Network for Power System Operation

In this paper, we propose a self-healing phasor measurement unit (PMU) network that exploits the features of dynamic and programmable configuration in a software-defined networking infrastructure to achieve resiliency against cyber-attacks. After a cyber-attack, the configuration of network switches is changed to isolate the compromised PMUs/phasor data concentrators to prevent further propagation of the attack; meanwhile, the disconnected yet uncompromised PMUs will be reconnected to the network to "self-heal" and thus restore the observability of the power system. Specifically, we formulate an integer linear programming model to minimize the overhead of the self-healing process (e.g., the recovery latency), while considering the constraints of power system observability, hardware resources, and network topology. We also propose a heuristic algorithm to decrease the computational complexity. Case studies of a PMU network based on the IEEE 30-bus and 118-bus systems are used to validate the effectiveness of the self-healing mechanism.

Cybersecurity↗

Frequency Event Categorization in Power Distribution Systems Using Micro PMU Measurements

Frequency is an important metric for power stability. To enhance the situational awareness in power distribution systems, this article proposes a data-driven approach that utilizes the data from micro phasor measurement units (μPMU) to categorize frequency events observed in distribution feeders. The proposed approach has three layers, each of which analyzes if a frequency event is propagated from the transmission system, formed inside a distribution feeder or falsely produced by instantaneous frequency (IF) estimation algorithms, respectively. In the first layer, the Granger causality is utilized to compare the causal relations from measurements across different locations to decide if an event is propagated from the transmission side. In the second layer, a trained sparse coding dictionary is utilized to unmix the physical causes of a frequency event. In the third layer, a moving z-score based event-pair detector is applied to identify if a frequency event is algorithm-induced. The proposed approach is tested using the μPMU measurements collected from Lawrence Berkeley National Laboratory (LBNL) and Riverside Public Utility (RPU).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Metrics for Assessment of Smart Grid Data Integrity Attacks

There is an emerging consensus that the nation’s electricity grid is vulnerable to cyber attacks. This vulnerability arises from the increasing reliance on using remote measurements, transmitting them over legacy data networks to system operators who make critical decisions based on available data. Data integrity attacks are a class of cyber attacks that involve a compromise of information that is processed by the grid operator. This information can include meter readings of injected power at remote generators, power flows on transmission lines, and relay states. These data integrity attacks have consequences only when the system operator responds to compromised data by redispatching generation under normal or contingency protocols. These consequences include (a) financial losses from sub-optimal economic dispatch to service loads, (b) robustness/resiliency losses from placing the grid at operating points that are at greater risk from contingencies, and (c) systemic losses resulting from cascading failures induced by poor operational choices. This paper is focused on understanding the connections between grid operational procedures and cyber attacks. We first offer two examples to illustrate how data integrity attacks can cause economic and physical damage by misleading operators into taking inappropriate decisions. We then focus on unobservable data integrity attacks involving power meter data. These are coordinated attacks where the compromised data are consistent with the physics of power flow, and are therefore passed by any bad data detection algorithm. We develop metrics to assess the economic impact of these attacks under re-dispatch decisions using optimal power flow methods. These metrics can be use to prioritize the adoption of appropriate countermeasures including PMU placement, encryption, hardware upgrades, and advance attack detection algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Closed-Form Solution for Synchrophasor Data Correction under GPS Spoofing Attack

Phasor Measurement Units (PMUs) are increasingly being deployed to augment monitoring, protection and control applications in the power grid. PMUs rely on the Global Positioning System (GPS) for generation of time-synchronized and accurate measurements. However, civilian GPS signals, being unencrypted, are susceptible to GPS spoofing attacks (GSA). Hence ensuring the integrity of GPS-timing dependent synchrophasor data has become critical. In this paper, a closed-form analytical solution for estimating the GSA phase shift has been proposed and integrated to the spoofing detection & correction framework. Extensive simulations have been performed in order to verify the accuracy of the solution in determining the location and the phase shift of the compromised PMU. Time domain dynamic simulations presented in this paper demonstrate the applicability of the proposed solution for near-real-time detection of GSA, and this will enable faster detection and correction of phase angles of compromised synchrophasor data.

Synchrophasor, PMUs, GPS, Spoofing, Data Correctio↗

Definition of System Angle Reference for Distribution Level Synchronized Angle Measurement Applications

Distribution phasor measurement units (DPMUs) provide power grid operators unprecedented system monitoring opportunities with local-area, synchronized, low latency, and high-resolution measurements. All raw angle measurements in DPMUs need a common angle reference for comparison since the phase is likely to be shifted by transformers in distribution network. To obtain a robust reference under conditions of data loss or local oscillation, this letter proposes a definition of system angle reference for DPMU. The effectiveness of this system angle is confirmed via real measurement data collected by DPMUs.

42 ENGINEERING↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Recent Development of Frequency Estimation Methods for Future Smart Grid

The frequency estimated by the Phasor Measurement Unit (PMU) is a critical index of power system status and supports many smart grid applications. The future smart grid features high penetration of renewables and more fast-moving power electronics inverters but raises challenges to the reliable frequency estimation. This article presents three methods to address these challenges. First, an enhanced zero-crossing algorithm was developed to track the fast-changing frequency in system dynamics. Second, we propose a technology that can tolerate the system transient and suppress the outliers. Third, an algorithm was developed to export high time-resolution frequency estimations with minimum computational effort. All of the proposed methods are realized in hardware and compared with classical frequency estimation methods. The testing results indicate that the proposed methods have excellent performance. They can be used in future PMUs and provide reliable and high time resolution data for smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SHARP-Net: Platform for Self-Healing and Attack Resilient PMU Networks

Synchrophasor technology plays a pivotal role in developing the next generation of wide-area monitoring, protection, and control in the smart grid environment. As technology and communications infrastructures evolve, however, so do the attack surfaces in the synchrophasor network that can be exploited by advanced persistent threat (APT) actors to affect power system stability and reliability. In this paper, we propose a novel platform for developing a self-healing and attack-resilient PMU network (SHARP-Net) by instituting a state-of-the-art intrusion detection system (IDS) with an intrusion mitigation system (IMS) and an alert management system (AMS). In particular, the proposed platform detects anomalies during cyberattacks on phasor data concentrators (PDCs) based on the rules defined in the IDS, then the generated alerts are published to the IMS through the AMS. The proposed IMS proceeds to take automated corrective responses to mitigate cyberattacks by reconfiguring the synchrophasor network to isolate the compromised PDCs, and it orchestrates new PDCs to prevent the future propagation of attacks. Further, the IMS restores the system's observability by reconnecting the new PDCs to make the grid attack-resilient. In this work, the SHARP-Net platform is developed by using Python-based libraries, minimega's software-defined network, and virtual machine orchestration. We implement and validate the proposed SHARP-Net architecture by testing a PMU network in the smart grid environment. SHARP-Net showed promising performance in detecting cyberattacks and mitigating them through the network reconfiguration.

computer architecture↗

Evaluation of electrostatic charge effects on the data processing system and the orbiter communication and tracking receivers

An analysis of radiated interference test results obtained from frictionally charged Orbiter TPS tile was presented. The tests included the measurement of noise pick-up by Orbiter S-band, L-band, C-band, and Ku-band antennas located beneath the tiles in a manner simulating their installation on Orbiter. In addition, the radiated field characteristics resulting from the static discharge was determined. The results are analyzed as to their effect on data bus equipment and on Orbiter Communications and Tracking (C&T) receivers. It was concluded that the radiated interference should have no effect on MDM's. However the CPU, IOP and PMU enclosures require some minor modification to assure immunity from P-static interference. Orbiter antenna tests indicate that the S-band receiver should not be affected by P-static noise. The TACAN and Radar Altimeter performance appears to be adequate but with a small margin. MSBLS performance is uncertain because laboratory instrumentation cannot approach the MSBLS sensitivity.

Lawton, R. M.↗

An Introduction to Goodness of Fit for PMU Parameter Estimation

New results of measurements of phasor-like signals are presented based on our previous work on the topic. In this document an improved estimation method is described. The algorithm (which is realized in MATLAB software) is discussed. We examine the effect of noisy and distorted signals on the Goodness of Fit metric. The estimation method is shown to be performing very well with clean data and with a measurement window as short as a half a cycle and as few as 5 samples per cycle. The Goodness of Fit decreases predictably with added phase noise, and seems to be acceptable even with visible distortion in the signal. While the exact results we obtain are specific to our method of estimation, the Goodness of Fit method could be implemented in any phasor measurement unit.

97 MATHEMATICS AND COMPUTING↗

Adaptive Linear State Estimation for Unbalanced Distribution System

The inclusion of PMU functionality in distribution relays enables the implementation of a linear state estimator (LSE) in Distribution Systems (DS). However, the unbalanced topology and phase coupling in distribution lines necessitate modifications to the LSE formulation. Additionally, the higher fault frequency in distribution systems requires a state estimation approach that is resilient to contingencies. This work proposes an adaptive linear state estimation algorithm tailored for unbalanced distribution systems with single-phase and two-phase laterals. Furthermore, a modified Optimal PMU Placement (OPP) strategy is introduced to ensure full observability in distribution systems with single-phase and two-phase buses. To maintain adaptability to topology changes, the state estimator incorporates circuit breaker status data provided by PMUs, ensuring robust performance during topology changes triggered by faults. The performance of the algorithm is verified on the IEEE 13-bus, 34-bus, and 123-bus systems.

PMUs↗

Electromechanical Mode Estimation in the Presence of Periodic Forced Oscillations

Electromechanical modes are inherent to any inter-connected power systems which provide a measure of the small-signal stability margin of the system. A number of algorithms have been developed for the estimation of these modes using synchrophasor measurements. However, most of these algorithms are not designed to operate in the presence of forced oscillations (FO). These FOs are results of periodic rogue input driving the system. When FOs are present, estimates of system modes can be biased depending on the frequency and the amplitude of the FOs. To tackle this problem, a new algorithm is proposed in this paper to estimate system modes in the presence of FOs. In the proposed method, the over-determined modified Yule-Walker method which is used to estimate AR coefficients of an ARMA (Auto-Regressive Moving-Average) signal model is extended to an ARMA with exogenous input (ARMAX) model that incorporates the presence of FOs. Two versions of the proposed method are included in this paper based on the requirement of the information of the duration of FOs in the signal. Furthermore, the results obtained by implementing the proposed algorithm on simulated data and real-world data validate the effectiveness of both versions of the proposed method.

42 ENGINEERING↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Demonstration of a Novel Synchrophasor-based Situational Awareness System: Wide Area Power System Visualization, On-line Event Replay and Early Warning of Grid Problems

Since the large North Eastern power system blackout on August 14, 2003, U.S. electric utilities have spent lot of effort on preventing power system cascading outages. Two of the main causes of the August 14, 2003 blackout were inadequate situational awareness and inadequate operator training In addition to the enhancements of the infrastructure of the interconnected power systems, more research and development of advanced power system applications are required for improving the wide-area security monitoring, operation and planning in order to prevent large- scale cascading outages of interconnected power systems. It is critically important for improving the wide-area situation awareness of the operators or operational engineers and regional reliability coordinators of large interconnected systems. With the installation of large number of phasor measurement units (PMU) and the related communication infrastructure, it will be possible to improve the operators’ situation awareness and to quickly identify the sequence of events during a large system disturbance for the post-event analysis using the real-time or historical synchrophasor data. The purpose of this project was to develop and demonstrate a novel synchrophasor-based comprehensive situational awareness system for control centers of power transmission systems. The developed system named WASA (Wide Area Situation Awareness) is intended to improve situational awareness at control centers of the power system operators and regional reliability coordinators. It consists of following main software modules: • Wide-area visualizations of real-time frequency, voltage, and phase angle measurements and their contour displays for security monitoring. • Online detection and location of a major event (location, time, size, and type, such as generator or line outage). • Near-real-time event replay (in seconds) after a major event occurs. • Early warning of potential wide-area stability problems. The system has been deployed and demonstrated at the Tennessee Valley Authority (TVA) and ISO New England system using real-time synchrophasor data from openPDC. Apart from the software product, the outcome of this project consists of a set of technical reports and papers describing the mathematical foundations and computational approaches of different tools and modules, implementation issues and considerations, lessons learned, and the results of lidation processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real Time Effective Impedance Estimation for Power System State Estimation

Here, we introduce two tools-the Effective Impedance State Estimator (EISE), and the Real Time Effective Impedance Estimator (RTEIE). The EISE is novel in that it is an entirely data-driven state estimator, and does not require a network model. Thus, the EISE is well suited for applications in which an accurate network model is not available. Instead of using a network impedance model, the EISE uses an effective impedance network model that is learned online by the RTEIE. The RTEIE recursively estimates the effective impedance network model using phasor measurement unit (PMU) measurements. The mathematical reasoning for using an effective impedance model, rather than a full network impedance model, is given. The recursive estimation framework allows the RTEIE to take the entire history of phasor measurements into account to produce a model estimate, while still adjusting to changes in the network impedance due to external factors such as topology changes and temperature. The merits of the RTEIE and EISE are demonstrated by comparing the accuracy of the EISE with a conventional state estimator on a toy network.

24 POWER TRANSMISSION AND DISTRIBUTION↗