Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characteristics of a four element gyromagnetic nonlinear transmission line array high power microwave source

In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of ±16.7° is also demonstrated, and the associated general radiation pattern is detailed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hidden Moving Target Defense against False Data Injection in Distribution Network Reconfiguration

This paper introduces Moving Target Defense (MTD) in distribution system against False Data Injection (FDI) attacks on the supervisory control and data acquisition (SCADA) system. Based on the AC power flow model, a hidden MTD (HMTD) strategy is constructed in combination with network reconfiguration by minimizing the system loss and line power flow differences before and after the HMTD. The proposed HMTD-based network reconfiguration is formulated as a mixed-integer nonlinear programming (MINLP) problem. A refined Genetic Algorithm (GA) is proposed to solve it. Numerical test is conducted in a modified IEEE-66 bus system. The simulation results show that the proposed model reduces the power loss introduced by the HMTD as well as yields a stealthy MTD to the attackers. The impact of HMTD on the system performance is also compared with that of the existing MTD strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Automatic Load-Frequency Control with Optimality in Power Systems

With the increasing penetration of renewable energy resources, power systems face new challenges in balancing power supply and demand and maintaining the nominal frequency. This paper studies load control to handle these challenges. In particular, a fully distributed automatic load control algorithm, which only needs local measurement and local communication, is proposed. We prove that the control algorithm globally converges to an optimal operating point which minimizes the total disutility of users, restores the nominal frequency and the scheduled tie-line power flows, and respects the thermal constraints of transmission lines. It is also shown that the convergence still holds even when inaccurate system parameters are used in the control algorithm. Lastly, the effectiveness, optimality, and robustness of the proposed algorithm are demonstrated via numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uniform redundancy allocation maximizes the robustness of flow networks against cascading failures

We study the robustness of flow networks against cascading failures under a partial load redistribution model. In particular, we consider a flow network of N lines with initial loads L 1 ,...,L N and free spaces (i.e., redundant space) S 1 ,...,S N that are independent and identically distributed with joint distribution P LS (x,y) = P[L ≤ x, S ≤ y]. The capacity C i is the maximum load allowed on line i and is given by C i = L i + S i . Furthermore, when a line fails due to overloading, it is removed from the system and (1 – ε) fraction of the load it was carrying is redistributed equally among all remaining lines in the system. The rest (i.e., ε fraction) of the load is assumed to be lost or absorbed, e.g., due to advanced circuitry disconnecting overloaded power lines or an interconnected network or material absorbing a fraction of the flow from overloaded lines. We analyze the robustness of this flow network against random attacks that remove a p fraction of the lines. Our contributions include (i) deriving the final fraction of alive lines n ∞ (p,ε) for all p,εϵ(0,1) and confirming the results via extensive simulations; (ii) showing that partial redistribution might lead to (depending on the parameter 0 < ε ≤ 1) the order of transition at the critical attack size p* changing from first to second-order; and (iii) proving analytically that flow networks achieve maximum robustness [quantified by the area ∫$^{1}_{0}$ n ∞ (p,ε)dp] when all lines have the same free space regardless of their initial load. The optimality of equal free-space allocation is also confirmed on real-world data from the UK National Power Grid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Automatic Load-Frequency Control with Optimality in Power Systems: Preprint

With increasing penetrations of renewable energy resources, power systems face new challenges in balancing supply and demand and maintaining nominal frequency. This paper studies load control to handle these challenges. In particular, a fully distributed automatic load control algorithm, which needs only local measurement and local communications, is proposed. We prove that the control algorithm globally converges to an optimal operating point that minimizes the total disutility of users, restores the nominal frequency and the scheduled tie-line power flows, and respects the thermal constraints of transmission lines. We also show that the convergence holds even when inaccurate system parameters are used in the control algorithm. Last, the effectiveness, optimality, and robustness of the proposed algorithm are demonstrated via numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MRT 7365: Power flow physics and key physics phenomena

The Z accelerator at Sandia National Laboratories conducts z-pinch experiments at 26 MA in support of DOE missions in stockpile stewardship, dynamic materials, fusion, and other basic sciences. Increasing the current delivered to the z-pinch would extend our reach in each of these disciplines. To achieve increases in current and accelerator efficiency, a fraction of Z’s shots are set aside for research into transmission-line power flow. These shots, with supporting simulations and theory, are incorporated into this Advanced Diagnostics milestone report. The efficiency of Z is reduced as some portion of the total current is shunted across the transmission-line gaps prior to the load. This is referred to as “current loss”. Electrode plasmas have long been implicated in this process, so the bulk of dedicated power-flow experiments are designed to measure the plasma environment. The experimental analyses are enhanced by simulations conducted using realistic hardware and Z voltage pulses. In the same way that diagnostics are continually being improved for sensitivity and resolution, the modeling capability is continually being improved to provide faster and more realistic simulations. The specifics of the experimental hardware, diagnostics, simulations, and algorithm developments are provided in this report. The combined analysis of simulation and data confirms that electrode plasmas have the most detrimental impact on current delivery. Experiments over the last three years have tested the theoretical current-loss mechanisms of enhanced ion current, plasma gap closure, and Hall-related current. These mechanisms are not mutually exclusive and may be coincident in the final feed as well as in upstream transmission lines. The final-feed geometries tested here, however, observe lower-density plasmas without dominant ion currents which is consistent with a Hall-related current. The picture of plasma formation and transport formed from experiment and simulation is informing hardware designs being fielded on Z now and being proposed for the Next-Generation Pulsed Power (NGPP) facility. In this picture, the strong magnetic fields that heat the electrodes above particle emission thresholds also confine the charged particles near the surface. Some portion of the plasmas thus formed is transported into the transmission-line gap under the force of the electric field, with aid from plasma instabilities. The gap plasmas are then transported towards the load by a cross-field drift, where they accumulate and contribute to a likely Hall-related cross-gap current. The achievements in experimental execution, model validation, and physical analysis presented in this report set the stage for continued progress in power flow and load diagnostics on Z. The planned shot schedule for Z and Mykonos will provide data for extrapolation to higher current to ensure the predicted performance and efficiency of a NGPP facility.

43 PARTICLE ACCELERATORS↗

Imprint of DESI fiber assignment on the anisotropic power spectrum of emission line galaxies

The Dark Energy Spectroscopic Instrument (DESI), a multiplexed fiber-fed spectrograph, is a Stage-IV ground-based dark energy experiment aiming to measure redshifts for 29 million Emission-Line Galaxies (ELG), 4 million Luminous Red Galaxies (LRG), and 2 million Quasi-Stellar Objects (QSO). The survey design includes a pattern of tiling on the sky, the locations of the fiber positioners in the focal plane of the telescope, and an observation strategy determined by a fiber assignment algorithm that optimizes the allocation of fibers to targets. This strategy allows a given region to be covered on average five times for a five-year survey, with a typical variation of about 1.5 about the mean, which imprints a spatially-dependent pattern on the galaxy clustering. In this study, we investigate the systematic effects of the fiber assignment coverage on the anisotropic galaxy clustering of ELGs and show that, in the absence of any corrections, it leads to discrepancies of order ten percent on large scales for the power spectrum multipoles. We introduce a method where objects in a random catalog are assigned a coverage, and the mean density is separately computed for each coverage factor. We show that this method reduces, but does not eliminate the effect. We next investigate the angular dependence of the contaminated signal, arguing that it is mostly localized to purely transverse modes. We demonstrate that the cleanest way to remove the contaminating signal is to perform an analysis of the anisotropic power spectrum P( k ,μ) and remove the lowest μ bin, leaving μ > 0 modes accurate at the few-percent level. Here, μ is the cosine of the angle between the line-of-sight and the direction of $\vec k$. Lastly, we also investigate two alternative definitions of the random catalog and show that they are comparable but less effective than the coverage randoms method.

79 ASTRONOMY AND ASTROPHYSICS↗

Modular Hybrid Solid State Transformer (H-SST) for Next Generation Flexible and Adaptable Large Power Transformer (LPT) (Final Technical Report)

A 500 kVA HSST, the world first of such system, has been successfully developed. The HSST has the capability to regulate the power flow of the transmission or distribution power lines, or provide voltage regulation. The HSST design is modular therefore it has the ability to be connected in series of parallel to form a large power transformer with smart controllability. The project has enabled a high TRL level prototype be demonstrated at University of Texas at Austin which can lead to additional commercialization and demonstration opportunities. A large number of students were trained under this program that will benefit the power grid industry. A number of publications are published at well known international conferences and journals, further accomplish the mission of knowledge development and dissemination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Brownfields to Brightfields: A Sustainability Initiative at DOE'S East Tennessee Technology Park Cleanup - 16120

As DOE works toward completing their cleanup mission at the East Tennessee Technology Park (ETTP), the ultimate goal is to return property no longer needed for government use to the community for beneficial re-use. The vision for ETTP is to transform the former gaseous diffusion facility into a commercial industrial park, leveraging the site's infrastructure to attract businesses to the site. While hundreds of acres at ETTP have been transferred for re-use, areas within the former production footprint of the site have future use restricted due to the presence of residual contamination, underground structures and utilities and/or physical features that limit their reuse potential. Brownfield redevelopment with solar energy generation has proven to be an excellent option for beneficial reuse and sustainability thanks to the flexible nature of solar photovoltaic technology and design that can address the restrictions and limitations of the site. Developing a solar project on a cleanup site can be challenging due to a large number of stakeholders and regulatory compliance issues of the environmental legacy at DOE cleanup sites; however, the challenges can be offset by the available infrastructure and low cost property. The requirement for large amounts of land or surface area is a major constraint to the growth of photovoltaic solar systems. An average solar generating facility requires 2 or more hectares (5 acres) for each megawatt (MW) of power generated. Re-using land that is otherwise un-developable provides a cost effective site for renewable energy generation to innovative solar developers. At ETTP, DOE's Oak Ridge Office of Environmental Management and the community reuse organization (Community Reuse Organization of East Tennessee - CROET) supported a local small business (Restoration Services, Inc. - RSI) familiar with the site and environmental regulations to secure a power purchase agreement with the regional electric provider (Tennessee Valley Authority - TVA) for a 1 MW utility-scale photovoltaic solar facility. The solar facility, Powerhouse Six, was developed through a commercial partnership (RSI and Vis Solis, Inc.) that worked closely with the lead ETTP site cleanup contractor (URS-CH2M Oak Ridge LLC - UCOR) and the local government. The selected site at ETTP had limitations on subsurface disturbance to 10 feet below ground surface because of utility ducts and residual contamination. Near surface relics (facility foundation remnants) were also found to prohibit ground penetration. A photovoltaic solar design using a ballasted ground mount system was developed to conform to the restrictions. The ballasted system could follow existing land contours, eliminating the need for any extensive site preparation and avoiding the risk of ground penetration. The lead cleanup contractor's role in facilitating the completion of this project included making the necessary environmental assessment documentation available to obtain the construction notice to proceed from the regional electric provider. They accelerated the transfer of ETTP power lines and electric demand to the city electric department to accommodate connection to the electric grid and supplied the communication connection required for metering the electric power generation. DOE's support along with their cleanup contractor's re-industrialization program and power integration group provided regular communication with the project stakeholders for more than six months to facilitate the early transfer of the utility infrastructure. Powerhouse Six sustainability benefits: - Generates enough clean energy to power more than 100 homes or prevents pollution equivalent to removing 240 cars from the road annually (1,141 metric tons of carbon dioxide); - Provides Brownfield reuse/redevelopment at ETTP; - Eliminates the generation of wastes through excavation and saves money to cleanup other areas for re-use; - Supports regional electric provider's renewable energy initiative; - Offers community economic development/ jobs and property tax income to the City of Oak Ridge; - Demonstrates benefit of ETTP re-industrialization; - Provides long-term lease payments to the community reuse organization; - Supports DOE renewable energy goals; - Demonstrates collaboration between DOE and a public utility for renewable energy development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Connecting Renewables Directly to the Grid: Resilient Multi-Terminal HVDC Networks with High-Voltage High-Frequency Electronics

GENI Project: GE is developing electricity transmission hardware that could connect distributed renewable energy sources, like wind farms, directly to the grid—eliminating the need to feed the energy generated through intermediate power conversion stations before they enter the grid. GE is using the advanced semiconductor material silicon carbide (SiC) to conduct electricity through its transmission hardware because SiC can operate at higher voltage levels than semiconductors made out of other materials. This high-voltage capability is important because electricity must be converted to high-voltage levels before it can be sent along the grid’s network of transmission lines. Power companies do this because less electricity is lost along the lines when the voltage is high.

ARPA-E↗

Lightning location system supervising Swedish power transmission network

For electric utilities, the ability to prevent or minimize lightning damage on personnel and power systems is of great importance. Therefore, the Swedish State Power Board, has been using data since 1983 from a nationwide lightning location system (LLS) for accurately locating lightning ground strikes. Lightning data is distributed and presented on color graphic displays at regional power network control centers as well as at the national power system control center for optimal data use. The main objectives for use of LLS data are: supervising the power system for optimal and safe use of the transmission and generating capacity during periods of thunderstorms; warning service to maintenance and service crews at power line and substations to end operations hazardous when lightning; rapid positioning of emergency crews to locate network damage at areas of detected lightning; and post analysis of power outages and transmission faults in relation to lightning, using archived lightning data for determination of appropriate design and insulation levels of equipment. Staff have found LLS data useful and economically justified since the availability of power system has increased as well as level of personnel safety.

Melin, Stefan A.↗

Novel Health Assessment Techniques for a Modern Power Distribution System

Distribution systems are large and complex systems that grow over time. When contingencies occur dispatchers, engineers, and executives need to know the answer to the question, "How bad is it?", in order to make timely and meaningful decisions. Therefore, a scalable method to add context to system conditions is needed. In this paper we present novel deviation-based techniques which enable scaled bus voltage and line power measurement deviations to quickly assess local and global health, and lend context to the severity of contingencies. The proposed techniques are demonstrated using simulations of line-to-line, line-to-ground, and three-phases-to-ground fault conditions on an IEEE 33-bus distribution model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harmonics of 60 Hz in power systems caused by geomagnetic disturbances

Simultaneous VLF/ULF observations carried out near Winnipeg, Manitoba show that geomagnetic disturbances control the behavior of harmonics of 60 Hz man-made electric power. The harmonics of 60 Hz detected by the VLF receiver are at multiples of 180 Hz, indicating that they originated from a 3 phase ac power system. Under geomagnetically quiet conditions, only odd harmonics of 70 Hz were detected. In disturbed conditions, both odd and even harmonics were excited. The strength of each harmonic changed concurrently with geomagnetic pulsation (ULF) activity. These findings seem to indicate that a portion of telluric currents shunted into the power line system through the neutrals of the Y-connected transformers give rise to a dc bias to the transformer core materials and that it distorts their hysteresis loops, activating harmonics of 60 Hz power. A mathematical proof is given that a hysteresis loop having a point of symmetry generates odd harmonics only, whereas loops lacking in point-symmetry generally give rise to both odd and even harmonics. A general formula was obtained to calculate the strength of each harmonic based on the shape of the hysteresis loop.

Hayashi, K.↗

Broadband Communications Using High Voltage Transmission Lines - A Review

The possibilities afforded by using an existing transmission line infrastructure for the transport of broadband communications are many ranging from (conventional) A-to-B point-to-point links, to integration of Wi-Fi access points mounted at defined network (power and communications) locations, to operation as a fault-tolerant, rollover backup communications fabric (in conjunction with other transport media, such as optical fiber or terrestrial microwave). As stated by RCR Wireless reporter Jeff Kagan – regarding an ongoing in-field demonstration - “This is so much more cost effective for the company and so much easier for them to deliver an ultra-fast, gigabit speed, wireless internet connection anywhere there are power lines.” The same situation arises for a utility looking to augment or simply deploy a communications fabric in their region via treating the transmission line infrastructure as a communication fabric thereby reducing the cost and complexity of deployment. A circa 2020 review of broadband over powerlines (BPL) is presented here.

42 ENGINEERING↗

Distribution system simulator

In a series of tests performed under the Department of Energy auspices, power line carrier propagation was observed to be anomalous under certain circumstances. To investigate the cause, a distribution system simulator was constructed. The simulator was a physical simulator that accurately represented the distribution system from below power frequency to above 50 kHz. Effects such as phase-to-phase coupling and skin effect were modeled. Construction details of the simulator, and experimental results from its use are presented.

Bahrami, K. A.↗

Multi-epoch spectroscopy of dwarf galaxies with AGN signatures: identifying sources with persistent broad Hα emission

We use time-domain optical spectroscopy to distinguish between broad emission lines powered by accreting black holes (BHs) and stellar processes (i.e., supernovae) for 16 galaxies identified as active galactic nucleus (AGN) candidates by Reines et al (2013). Our study is primarily focused on those objects with narrow emission line ratios dominated by star formation, for which the origin of the broad Hα emission was unclear. Based on follow-up spectroscopy, we find that the broad Hα emission has faded or was ambiguous for all of the star-forming objects (14/16), over baselines ranging from 5–14 years, suggesting a transient stellar process was responsible for the broad emission in previous Sloan Digital Sky Survey observations. For the two objects in our follow-up sample with narrow-line AGN signatures (RGG 9 and RGG 119), we find persistent broad Hα emission consistent with an AGN origin. Additionally, we use high spectral resolution observations to measure stellar velocity dispersions for 15 objects in the Reines et al. (2013) sample, all with narrow-line ratios indicating the presence of an AGN. Stellar masses range from ∼5×10{sup 8} to 3×10{sup 9} M {sub ⊙}, and we measure σ{sub ∗} in the range of 28--71 km s{sup −1}. These σ{sub ∗} correspond to some of the lowest-mass galaxies with optical signatures of AGN activity. We show that RGG 119, the one object that has both a measured σ{sub ∗} and persistent broad Hα emission, falls near the extrapolation of the M{sub BH}−σ{sub ⋆} relation to the low-mass end.

79 ASTRONOMY AND ASTROPHYSICS↗

Line-Focus Solar Power Plant Cost Reduction Plan (Milestone Report)

Line-focus solar collectors, in particular parabolic trough collectors, are the most mature and proven technology available for producing central electricity from concentrated solar energy. Because this technology has over 25 years of successful operational experience, resulting in a low perceived risk, it is likely that it will continue to be a favorite of investors for some time. Theconcentrating solar power (CSP) industry is developing parabolic trough projects that will cost billions of dollars, and it is supporting these projects with hundreds of millions of dollars of research and development funding. While this technology offers many advantages over conventional electricity generation -- such as utilizing plentiful domestic renewable fuel and having very low emissionsof greenhouse gases and air pollutants -- it provides electricity in the intermediate power market at about twice the cost of its conventional competitor, combined cycle natural gas. The purpose of this document is to define a set of activities from fiscal year 2011 to fiscal year 2016 that will make this technology economically competitive with conventional means.

14 SOLAR ENERGY↗

Dependence of Z-R Relations on the Rain Type Classification Scheme

The TRMM Global Validation Program is giving us a unique opportunity to compare radar datasets from different sites since they are analyzed in a relatively uniform procedure. Monthly Ze-R relations for four different sites (i.e, Melbourne Florida, Houston Texas, Darwin Australia and Kwajalein Atoll) were derived. The relations were obtained using the Window Probability Matching Method (WPMM). This version of the PMM relies on matching unconditional probabilities of rain rates, R, and radar reflectivity, Ze, using rain gauge and radar data, respectively. This procedure was done separately for convective and stratiform rain type using the Steiner classification procedure. The radar and gauge data from all sites were quality controlled using the same algorithms, which include also an automatic procedure to filter unreliable rain gauge data upon comparison to radar data. An adjusted power law Z-R for each rain type was also derived by comparing the radar-gauge coincident pairs in order to adjust the total monthly rainfall to match the gauges. The obtained PMM based Ze-R relations are found to be curved lines in log-log space rather than any straight line power law. While the PMM based Ze-R curves were always distinctly different between the convective and stratiform rain, the power law based Z-R, in few cases, was found to be the same for both types. In general, a given reflectivity was matched to a much lower rain intensity in the convective rainfall as compared to that in stratiform rainfall. These findings are inherently contradictory to previous findings based on disdrometer data and suggest some precaution for using the latter Z-R relations on radar data when the partition of stratiform and convective rainfall amount is in concern. The inverse trends in the relations might be caused by effects such as partial beam fillings, the use of different classification schemes, as well as having a distinct difference in the Z-R relations between the initial convective and the trailing transition regions as suggested by recent findings.

Amitai, Eyal↗