Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Atom-probe tomography of tribological boundary films resulting from boron-based oil additives

Correlative characterization using atom-probe tomography (APT) and transmission electron microscopy (TEM) was performed on a tribofilm formed during sliding frictional testing with a fully formulated engine oil, which also contains a boron-based additive. The tribofilm formed is ~15 nm thick and consists of oxides of iron and compounds of B, Ca, P, and S, which are present in the additive. This study provides strong evidence for boron being embedded in the tribofilm, which effectively reduces friction and wear losses.

Atom-probe tomography↗

Dynamics of Water Molecules and Ions in Concentrated Lithium Chloride Solutions Probed with Ultrafast 2D IR Spectroscopy

Water and ion dynamics in concentrated LiCl solutions were studied using ultrafast 2D IR spectroscopy with the methyl thiocyanate (MeSCN) CN stretch as the vibrational probe. The IR absorption spectrum of MeSCN has two peaks, one peak for water associated with the nitrogen lone pair of MeSCN (W) and the other peak corresponding to Li + associated with the lone pair (L). To extract the spectral diffusion (structural dynamics) of W and L species, we developed a method that isolates the peak of interest by subtracting the 2D Gaussian proxies of multiple interfering peaks. Center line slope data (normalized frequency–frequency correlation function) for 2D bands from the W and L are fit with triexponential functions. The fastest component (1.1–1.6 ps) is assigned to local hydrogen bond length fluctuations. The intermediate timescale (~4.0 ps) corresponds to the hydrogen bond network rearrangement. The slowest component decays in ~40 ps and corresponds to ion pair and ion cluster dynamics. The very similar W and L spectral diffusion indicates that the motions of the water and ions are strongly coupled. Orientational relaxations of the W and L species were extracted using a new method to eliminate the effects of overlapping peaks. The results show that MeSCN bound to water undergoes orientational relaxation significantly faster than MeSCN bound to Li + . The orientational and spectral diffusion results are compared. In conclusion, a Stark coupling model is used to extract the root mean square average electric field caused by the ion clouds along the CN moiety as a function of concentration.

14 SOLAR ENERGY↗

Sub-10 nm Probing of Ferroelectricity in Heterogeneous Materials by Machine Learning Enabled Contact Kelvin Probe Force Microscopy

Reducing the dimensions of ferroelectric materials down to the nanoscale has strong implications on the ferroelectric polarization pattern and on the ability to switch the polarization. As the size of ferroelectric domains shrinks to the nanometer scale, the heterogeneity of the polarization pattern becomes increasingly pronounced, enabling a large variety of possible polar textures in nanocrystalline and nanocomposite materials. Critical to the understanding of fundamental physics of such materials and hence their applications in electronic nanodevices is the ability to investigate their ferroelectric polarization at the nanoscale in a nondestructive way. We show that contact Kelvin probe force microscopy (cKPFM) combined with a k-means response clustering algorithm enables to measure the ferroelectric response at a mapping resolution of 8 nm. In a BaTiO 3 thin film on silicon composed of tetragonal and hexagonal nanocrystals, we determine a nanoscale lateral distribution of discrete ferroelectric response clusters, fully consistent with the nanostructure determined by transmission electron microscopy. Moreover, we apply this data clustering method to the cKPFM responses measured at different temperatures, which allows us to follow the corresponding change in the polarization pattern as the Curie temperature is approached and across the phase transition. This work opens up perspectives for mapping complex ferroelectric polarization textures such as curled/swirled polar textures that can be stabilized in epitaxial heterostructures and more generally for mapping the polar domain distribution of any spatially highly heterogeneous ferroelectric materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PROBING STRESS EFFECTS IN SINGLE CRYSTAL ORGANIC TRANSISTORS BY SCANNING KELVIN PROBE MICROSCOPY

We report scanning Kelvin probe microscopy (SKPM) of single crystal difluoro bis(triethylsilylethynyl) anthradithiophene (diF-TESADT) organic transistors. SKPM provides a direct measurement of the intrinsic charge transport in the crystals independent of contact effects and reveals that degradation of device performance occurs over a time period of minutes as the diF-TESADT crystal becomes charged.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning probe microscope simulator for the assessment of noise in scanning probe microscopy controllers

We present an electronic circuit that allows to calibrate and troubleshoot scanning probe microscopy (SPM) controllers with respect to their noise performance. The control signal in an SPM is typically highly nonlinear—the tunneling current in scanning tunneling microscopy (STM) varies exponentially with distance. The exponential current-versus-voltage characteristics of diodes allow to model the current dependence in STM. Additional inputs allow to simulate the effects of external perturbations and the reactions of the control electronics. We characterized the noise performance of the feedback controller using the apparent topography roughness of recorded images. For a comparison of different STM controllers, an optimal gain parameter was determined by exploring settling times through a rectangular perturbation signal. We used the circuit to directly compare the performance of two types of SPM controllers used in our laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing phonon softening in ferroelectrics by scanning probe microwave spectroscopy

Microwave measurements have recently been successfully applied to measure ferroelectric materials on the nanoscale, including detection of polarization switching and ferroelectric domain walls. In this study we discuss the question of whether scanning probe microscopy operating at microwave frequency can identify the changes associated with the soft phonon dynamics in a ferroic. The analytical expressions for the electric potential, complex impedance, and dielectric losses are derived and analyzed, since these physical quantities are linked to experimentally measurable properties of the ferroic. As a ferroic we consider virtual or proper ferroelectric with an optic phonon mode that softens at a Curie point. We also consider a decay mechanism linked to the conductance of the ferroic, thus manifesting itself as the dielectric loss in the material. Our key finding is that the influence of the soft phonon dispersion on the surface potential distribution, complex impedance, and dielectric losses are evidently strong in the vicinity (~10–30 K) of the Curie temperature. Additionally, we quantified how the spatial distribution and frequency spectra of the complex impedance and the dielectric losses react on the dynamics of the soft phonons near the Curie point. These results set the stage for characterization of polar phase transitions with nanoscale microwave measurements, providing a complementary approach to well established electromechanical measurements for fundamental understanding of ferroelectric properties as well as their applications in telecommunication and computing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Infrared Microscopy as a Probe of Composition within a Model Biofuel Cell Electrode Prepared from Trametes versicolor Laccase

Abstract Infrared microscopy was applied in the study of laccase biofuel cell electrodes that demonstrated high current and power densities traceable to the use of a low equivalent weight (EW), short side chain (Aquivion) ionomer in the catalyst layer. The electrodes were prepared from a biocatalyst ink composed of orientation‐directing anthracene‐modified multi‐walled carbon nanotubes (An‐MWCNTs) in a dispersion of ionomer exchanged by hydrophobic cations. The ink was applied to an electronically conductive carbon felt support that was hot‐pressed to a Nafion‐NRE 212 (51 μm thickness) membrane, forming the framework for an air‐breathing biofuel cell cathode. Infrared microscopy sampling was performed with the use of a micro‐attenuated total reflection probe that enabled spectra to be recorded from ∼32 μm diameter circular spatial regions on the materials investigated. Sensitivity to deformation of the soft polymer membrane‐based materials was assessed through trial experiments on pure membrane samples before approaching the compositionally more complex biofuel cell electrodes. In studies of laccase cathodes, infrared spectral features of enzyme, buffer anions and surrounding An‐MWCNTs were identified. Heterogeneity in the spatial distribution of components and unexpected bands traceable to insoluble copper salts were detected. The results suggest directions for improving electrode activity and bring to light needs for advancing quantitative interpretations.

Liang, Ying↗

Design and expected performance of a fast neutron attenuation probe for light element density measurements

In this paper, we present the design and expected performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20–30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8±0.5% of the true value. Lastly, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5–10% level for a two hour scan time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Molecular Chirality by Orbital-Angular-Momentum-Carrying X-ray Pulses

A twisted X-ray beam with orbital angular momentum is employed in a theoretical study to probe molecular chirality. A nonlocal response description of the matter-field coupling is adopted to account for the field short wavelength and the structured spatial profile. In this study, we use the minimal-coupling Hamiltonian, which implicitly takes into account the multipole contributions to all orders. The combined interactions of the spin and orbital angular momentum of the X-ray beam give rise to circular-helical dichroism signals, which are stronger than ordinary circular dichroism signals, and may serve as a useful tool for the study of molecular chirality in the X-ray regime.

74 ATOMIC AND MOLECULAR PHYSICS↗

Orientational Pair Correlations in a Dipolar Molecular Liquid: Time-Resolved Resonant and Nonresonant Pump–Probe Spectroscopies

Orientational pair correlations (OPCs), when they are sufficiently strong in a liquid, contain information on the interplay between structure and dynamics that arise from intermolecular interactions. Consequently, the quantification of OPCs remains a subject of substantial interest in current experimental and theoretical work. In the case of benzonitrile, the importance of OPCs remains ambiguous owing to the use of model-dependent analyses or reliance on a single spectroscopic technique. In this work, IR polarization selective pump-probe (PSPP) and optical heterodyne-detected optical Kerr effect (OHD-OKE) experiments were used to quantify OPCs in benzonitrile. These methods measure single molecule and collective relaxation, respectively. Comparison of the orientational correlation function (PSPP) of the naturally abundant 13CN stretching mode and the polarizability anisotropy relaxation (OHD-OKE) of the liquid revealed that collective reorientation was a factor of 1.56 ± 0.08 slower than the single molecule reorientation time. The two types of measurements on dilute benzonitrile in carbon tetrachloride were the same within experimental error. These results support the proposition that OPCs exist and arise from the formation of parallel-aligned intermolecular structures in the neat liquid.

14 SOLAR ENERGY↗

Reductive Dissolution Mechanisms at the Hematite-Electrolyte Interface Probed by In Situ X-ray Scattering

The electron-catalyzed dissolution and reprecipitation of iron (oxyhydr)oxides constitute critical steps in natural geochemical iron cycling. However, the atomic-scale mechanisms of reductive dissolution and oxidative precipitation of Fe2+ remain poorly understood because they are difficult to directly experimentally probe. Using in situ synchrotron X-ray scattering and a novel electrochemical cell, we interrogate the interfacial structure between the hematite (?-Fe2O3) (11 ¯02) surface and acidic aqueous solution (5 mM Na2SO4, pH 4.0) under controlled electrochemical potential from open circuit to cathodic bias as the reductive dissolution potential is approached and then exceeded. The crystalline order of the surface improves under mild reducing conditions, and the surface Fe stoichiometry changes with cathodic bias. After significant reductive dissolution occurs and cathodic bias is removed, dissolved Fe is re-deposited, forming a disordered interface. Unlike at circumneutral pH, water layers at the hematite interface with acidic solution are poorly ordered, likely due to the adsorption of sulfate from the electrolyte. These results provide a novel atomic-scale view into the behavior of reducible transition metal oxide surfaces under fluctuating (electro)chemical conditions.

McBriarty, Martin E.↗