Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Non-Gaussian Nature of Prostate Motion Based on Real-Time Intrafraction Tracking

Purpose: The objective of this work is to test the validity of the Gaussian approximation for prostate motion through characterization of its spatial distribution. Methods and Materials: Real-time intrafraction prostate motion was observed using Calypso 4-dimensional (4D) nonradioactive electromagnetic tracking system. We report the results from a total of 1024 fractions from 31 prostate cancer patients. First, the correlation of prostate motion in right/left (RL), anteroposterior (AP), and superoinferior (SI) direction were determined using Pearson's correlation of coefficient. Then the spatial distribution of prostate motion was analyzed for individual fraction, individual patient including all fractions, and all patients including all fractions. The displacement in RL, AP, SI, oblique, or total direction is fitted into a Gaussian distribution, and a Lilliefors test was used to evaluate the validity of the hypothesis that the displacement is normally distributed. Results: There is high correlation in AP/SI direction (61% of fractions with medium or strong correlation). This is consistent with the longitudinal oblique motion of the prostate, and likely the effect from respiration on an organ confined within the genitourinary diaphragm with the rectum sitting posteriorly and bladder sitting superiorly. In all directions, the non-Gaussian distribution is more common for individual fraction, individual patient including all fractions, and all patients including all fractions. The spatial distribution of prostate motion shows an elongated shape in oblique direction, indicating a higher range of motion in the AP and SI directions. Conclusions: Our results showed that the prostate motion is highly correlated in AP and SI direction, indicating an oblique motion preference. In addition, the spatial distribution of prostate motion is elongated in an oblique direction, indicating that the organ motion dosimetric modeling using Gaussian kernel may need to be modified to account for the particular organ motion character of prostate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Causes of Mortality After Dose-Escalated Radiation Therapy and Androgen Deprivation for High-Risk Prostate Cancer

Purpose: Men with high-risk prostate cancer have other competing causes of mortality; however, current risk stratification schema do not account for comorbidities. We aim to identify the causes of death and factors predictive for mortality in this population. Methods and Materials: A total of 660 patients with high-risk prostate cancer were treated with definitive high-dose external beam radiation therapy (≥74 Gy) and androgen deprivation (AD) between 1996 and 2009 at a single institution. Cox proportional hazards regression analysis was conducted to determine factors predictive of survival. Results: The median radiation dose was 78 Gy, median duration of AD was 6 months, and median follow-up was 74 months. The 10-year overall survival (OS) was 60.6%. Prostate cancer was the leading single cause of death, with 10-year mortality of 14.1% (95% CI 10.7-17.6), compared with other cancers (8.4%, 95% CI 5.7-11.1), cardiovascular disease (7.3%, 95% CI 4.7-9.9), and all other causes (10.4%, 95% CI 7.2-13.6). On multivariate analysis, older age (HR 1.55, P=.002) and Charlson comorbidity index score (CS) ≥1 (HR 2.20, P<.0001) were significant factors predictive of OS, whereas Gleason score, T stage, prostate-specific antigen, duration of AD, radiation dose, smoking history, and body mass index were not. Men younger than 70 years of age with CS = 0 were more likely to die of prostate cancer than any other cause, whereas older men or those with CS ≥1 more commonly suffered non-prostate cancer death. The cumulative incidences of prostate cancer-specific mortality were similar regardless of age or comorbidities (P=.60). Conclusions: Men with high-risk prostate cancer are more likely to die of causes other than prostate cancer, except for the subgroup of men younger than 70 years of age without comorbidities. Only older age and presence of comorbidities significantly predicted for OS, whereas prostate cancer- and treatment-related factors did not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric implications of residual seminal vesicle motion in fiducial-guided intensity-modulated radiotherapy for prostate cancer

To determine whether residual interfraction seminal vesicle (SV) displacement necessitates specific planning target volume (PTV) margins during fiducial-guided intensity modulated radiation therapy (IMRT) of the prostate. A planning computed tomography (CT) scan and 2 subsequent CT scans were prospectively obtained for 20 prostate cancer patients with intraprostatic fiducial markers. After CT registration, SV displacement relative to the prostate was quantified as a function of margin size for both the proximal (1 cm) SV (PSV) and the full SV (FSV). Two IMRT plans were simulated for each patient (prostate + PSV and prostate + FSV) both with a uniform 5-mm PTV margin. Minimum clinical target volume (CTV) dose (D{sub min}) and the volume of SV receiving 95% of the prescription dose (V{sub 95%}) were assessed during treatment and compared with the initial plan. In all cases, SV displacement with respect to the prostate was greater for the FSV compared with the PSV. To ensure at least 95% geometrical coverage of the CTV for 90% of patients, margins of 5 and 8 mm were required for the PSV and FSV, respectively. Dosimetrically, residual SV displacement had minimal impact on PSV coverage compared with FSV coverage. For the PSV D{sub min} was {>=}95% of the prescribed dose in 90% of patients with an overall mean V{sub 95%} of 99.6 {+-} 0.8%; for the FSV D{sub min} was {>=}95% of the prescribed dose in only 45% of patients with a mean V{sub 95%} of 97.9 {+-} 2.4%. The SVs move differentially from the prostate and exhibit greater variation with increasing distance from the prostate. For plans targeting just the prostate and PSVs, 5-mm PTV expansions are adequate. However, despite daily localization of the prostate, larger PTV margins are required for cases where the intent is to completely cover the FSV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imaging

Purpose: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. In this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. Methods: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. Results: MAPPER was evaluated on 13 patient studies from two independent datasets—Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2. State-of-the-art MRI-TRUS fusion methods report RMSE of 3.06–2.07 mm. Conclusions: MAPPER aligns MRI and TRUS imagery without manual intervention ensuring efficient, reproducible registration. MAPPER has a similar RMSE to state-of-the-art methods that require manual intervention.

60 APPLIED LIFE SCIENCES↗

SU-E-T-12: A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants

Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images. Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using patients’ PSA values as well as patients’ survival are warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-434: Fixed Margin Or Online Adaptation for Intermediate-Risk Prostate Stereotactic Body Radiation Therapy? A Dosimetric Study

Purpose: To investigate the choice of fixed margin or online adaptation when treating intermediate-risk prostate cancer including seminal vesicles (SV) using stereotactic body radiation therapy (SBRT). Methods: 9 prostate SBRT patients were retrospectively studied. All patients were implanted with fiducial markers in the prostate for daily localization and verification. Each patient had 5 pairs of pre-treatment and post-treatment cone-beam CT (CBCT) per protocol. SVs were contoured on planning CT and all CBCTs by one attending physician. Simultaneous integral boost (SIB) IMRT plans were developed to deliver 25Gy/5fx to the SV while delivering 37Gy/5fx to the prostate. A 3mm isotropic margin was added to the prostate while a 5 mm isotropic margin was used for the SV. The planning CT was registered to daily pre-treatment and post-treatment CBCT based on fiducial markers in the prostate to mimic online prostate localization; and the SV on daily CBCT was transferred to the CT structure set after the prostates were aligned. Daily pre-treatment and post-treatment SV dose coverage and the organ-at-risk (OAR) sparing were evaluated for the SIB regimen. At least 95% of the SV need to receive the prescription dose (5Gy per fraction). Results: For the total of 90 daily SVs analyzed (ten CBCTs for each of nine patients), only 45 daily SVs (50%) were able to meet the coverage that 95% of the SV received 25Gy. The OAR sparing performance was acceptable for most of the dosimetric constraints in low-risk prostate SBRT protocol with only two exceptions in bladder V100 (cc). Conclusion: A fixed 5mm margin for SV is not sufficient to provide consistent daily dose coverage due to SV’s substantial inter- and intra-fractional motion relative to the prostate. This finding calls for innovative strategies in margin design as well as online treatment adaptation. This work is partially supported a master research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be a useful tool in image-guided interventions for prostate-cancer diagnosis and treatment.

60 APPLIED LIFE SCIENCES↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MiR-141-3p promotes prostate cancer cell proliferation through inhibiting kruppel-like factor-9 expression

Evidence has revealed that some microRNAs play a critical role in tumor proliferation. We demonstrated that miR-141-3p appears to be a novel oncogene miRNA, which promotes prostate tumorigenesis and facilitates the stemness of prostate cancer cells via suppressing a key transcription factor kruppel-like factor-9 (KLF9). KLF9 is the core effector protein that might suppress tumor growth. MiR-141-3p is upregulated in prostate cancer cells and tissues compared to non-tumorigenic prostate epithelial cells and prostate tissues. MiR-141-3p positively regulated proliferation, spheroid formation, and expression of the stemness factors OCT-4, Nanog, SOX-9, Bmil, CCND1, and CD44 in PC-3 cells. Restoration of miR-141-3p suppresses the expression of the transcription factor KLF9 in PC-3 and accelerates prostate tumorigenesis via targeted binding with its 3′-UTR. Downregulation of KLF9 enhances spheres formation of prostate cancer cells. Our results suggest that miR-141-3p/KLF9 may play an important role in regulating the growth of prostate cancer and is a potential target of prevention and therapy. - Highlights: • MiR-141-3p is upregulated in human prostate cancer. • MiR-141-3p induces cell proliferation and apoptosis resistance. • KLF9 is a direct and functional target of miR-141-3p.

60 APPLIED LIFE SCIENCES↗

miR-410–3p promotes prostate cancer progression via regulating PTEN/AKT/mTOR signaling pathway

Prostate cancer has become one of commonest urologic tumors in male. In recent years, miRNAs are continually attracting attentions of researchers for their special regulatory function in human cancers. Previous study has revealed that miR-410 acts as a biomarker for the diagnosis of prostate cancer. Whereas, the specific biological function of miR-410–3p in prostate cancer remains unknown. The aim of this study is to explore the function and molecular mechanism of miR-410–3p in prostate cancer. The high expression of miR-410–3p was examined in prostate cancer tissues and cell lines by qRT-PCR. Next, the prognostic value was identified by Kaplan Meier method. High expression of miR-410–3p indicated poor prognosis of prostate cancer patients. To investigate the biological function of miR-410–3p in prostate cancer, loss-of function assays were designed and performed in two prostate cancer cell lines (PC3 and DU145). As a result, downregulated miR-410–3p suppressed cell proliferation, migration and EMT progress. Moreover, flow cytometry analysis was performed to determine that the acceleration effects of miR-410–3p on cell apoptosis. Mechanistically, further analysis demonstrated that the effects of miR-410–3p exert oncogenic functions through downregulating PTEN. All findings in this study revealed that miR-410–3p inhibits prostate cancer progression via downregulating PTEN/AKT/mTOR signaling pathway.

60 APPLIED LIFE SCIENCES↗

Segmental Urethral Dosimetry and Urinary Toxicity in Patients With No Urinary Symptoms Before Permanent Prostate Brachytherapy

Purpose: To determine whether segmental urethral dosimetry is predictive for the degree of urinary morbidity after prostate brachytherapy in patients with no urinary symptoms before prostate brachytherapy. Methods and Materials: Between May 2000 and November 2005, 1,107 patients underwent iodine-125 monotherapy with urethral sparing techniques. A total of 166 patients fulfilled the selection criteria: baseline (International Prostate Symptom Score) IPSS {<=}5, no androgen deprivation therapy, and prostate ultrasound planning volumes (PUTV) <45 mL. The median follow-up was 44 months. Urinary morbidity was defined by maximum increase in IPSS, time to IPSS resolution, maximum Radiation Therapy Oncology Group (RTOG) score, time to RTOG resolution, and urinary retention. Surrogate deviated urethra was contoured and doses calculated at the base, mid-prostate, apex, and urogenital diaphragm. Univariate and multivariate analysis was used to evaluate urethral and prostate dosimetry, age, PUTV, and number of needles for their association with urinary morbidity. Results: Urethral dose was fairly constant in all urethra segments except prostate base, where the variation in does was large. On multivariate analysis, higher urethral base D50, V100, and larger PUTV were predictive for higher maximum increase in IPSS. Higher urethral base V100 and larger PUTV predicted for prolonged IPSS resolution. Higher urethral base D50 and larger needle number predicted for longer RTOG resolution. Higher urethral base V100 predicted for RTOG {>=}2 toxicity. Conclusions: Radiation dose to the urethral base, larger PUTV, and needle number, predicted for increased urinary toxicity after prostate brachytherapy. Correlation between urinary morbidity and urethral base dosimetry may reflect a large variation in urethral dose observed at the prostate base.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of Intrafraction Prostate Motion: Accuracy of Pre- and Post-Treatment Imaging and Intermittent Imaging

Purpose: To evaluate whether pre- and post-treatment imaging (immediately before and after a radiation therapy treatment fraction) and intermittent imaging (at intervals during a treatment fraction) are accurate predictors of prostate motion during the delivery of radiation. Methods and Materials: The Calypso 4D Localization System was used to continuously track the prostate during radiation delivery in 35 prostate cancer patients, for a total of 1,157 fractions (28-45 per patient). Predictions of prostate motion away from isocenter were modeled for a pre- and post-treatment imaging schedule and for multiple intermittent intrafraction imaging schedules and compared with the actual continuous tracking data. The endpoint was drift of the prostate beyond a certain radial displacement for a duration of more than 30 s, 1 min, and 2 min. Results were used to evaluate the sensitivity and specificity of these models as an evaluation of intrafraction prostate motion. Results: The sensitivity of pre- and post-treatment imaging in determining 30 s of intrafraction prostate motion greater than 3, 5, or 7 mm for all fractions was low, with values of 53%, 49%, and 39%, respectively. The specificity of pre- and post-treatment imaging was high for all displacements. The sensitivity of intermittent imaging improved with increasing sampling rate. Conclusions: These results suggest that pre- and post-treatment imaging is not a sensitive method of assessing intrafraction prostate motion, and that intermittent imaging is sufficiently sensitive only at a high sampling rate. These findings support the value of continuous, real-time tracking in prostate cancer radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive Factors for Acute and Late Urinary Toxicity After Permanent Prostate Brachytherapy: Long-Term Outcome in 712 Consecutive Patients

Purpose: To describe the frequency of acute and late Radiation Therapy Oncology Group (RTOG) urinary toxicity, associated predictive factors, and resolution of International Prostate Symptom Score (IPSS) in 712 consecutive prostate brachytherapy patients. Methods and Materials: Patients underwent implantation between 1998 and 2003 (median follow-up, 57 months). The IPSS and RTOG toxicity data were prospectively collected. The patient, treatment, and implant factors were examined for an association with urinary toxicity. The time to IPSS resolution was examined using Kaplan-Meier curves, and multivariate modeling of IPSS resolution was done using Cox proportional hazards regression analysis. Logistic regression analysis was used to examine the factors associated with urinary toxicity. Results: The IPSS returned to baseline at a median of 12.6 months. On multivariate analysis, patients with a high baseline IPSS had a quicker resolution of their IPSS. Higher prostate D90 (dose covering 90% of the prostate), maximal postimplant IPSS, and urinary retention slowed the IPSS resolution time. The rate of the actuarial 5-year late urinary (>12 months) RTOG Grade 0, 1, 2, 3, and 4 was 32%, 36%, 24%, 6.2%, and 0.1%, respectively. At 7 years, the prevalence of RTOG Grade 0-1 was 92.5%. Patients with a larger prostate volume, greater number of needles, greater baseline IPSS, and use of hormonal therapy had more acute toxicity. On multivariate analysis, the significant predictors for late greater than or equal to RTOG toxicity 2 were a greater baseline IPSS, maximal postimplant IPSS, presence of acute toxicity, and higher prostate V150 (volume of the prostate covered by 150% of the dose). More recently implanted patients had less acute urinary toxicity and patients given hormonal therapy had less late urinary toxicity (all p < 0.02). Conclusion: Most urinary symptoms resolved within 12 months after prostate brachytherapy, and significant long-term urinary toxicity was very low. Refined patient selection and greater technical experience in prostate brachytherapy were associated with less urinary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in Prostate Shape and Volume and Their Implications for Radiotherapy After Introduction of Endorectal Balloon as Determined by MRI at 3T

Purpose: To determine the changes in prostate shape and volume after the introduction of an endorectal coil (ERC) by means of magnetic resonance imaging (MRI) at 3T. Methods and materials: A total of 44 consecutive patients with biopsy-proven prostate cancer underwent separate MRI examinations at 3T with a body array coil and subsequently with an ERC inflated with 50 mL of fluid. Prospectively, two experienced readers independently evaluated all data sets in random order. The maximal anteroposterior, right-to-left, and craniocaudal prostate diameters, as well as the total prostate and peripheral zone and central gland volumes were measured before and after ERC introduction. The changes in prostate shape and volume were analyzed using Wilcoxon's test for paired samples. Results: The introduction of the ERC significantly changed the prostate shape in all three directions, with mean changes in the anteroposterior, right-to-left, and craniocaudal diameters of 15.7% (5.5 mm), 7.7% (3.5 mm), and 6.3% (2.2 mm), respectively. The mean total prostate, peripheral zone, and central gland volume decreased significantly after ERC introduction by 17.9% (8.3 cm{sup 3}), 21.6% (4.8 cm{sup 3}), and 14.2% (3.4 cm{sup 3}), respectively. Conclusion: ERC introduction as observed by 3T MRI changed the prostate shape and volume significantly. The mean anteroposterior diameter was reduced by nearly one-sixth of its original diameter, and the mean total prostate volume was decreased by approximately 18%. This could cause difficulties and should be considered when using ERC-based MRI for MRI-computed tomography fusion and radiotherapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual Prostate Cancer in Patients Treated With Endocrine Therapy With or Without Radical Radiotherapy: A Side Study of the SPCG-7 Randomized Trial

Purpose: The Scandinavian Prostate Cancer Group-7 randomized trial demonstrated a survival benefit of combined endocrine therapy and external-beam radiotherapy over endocrine therapy alone in patients with high-risk prostate cancer. In a subset of the study population, the incidence and clinical implications of residual prostate cancer in posttreatment prostate biopsy specimens was evaluated. Methods and Materials: Biopsy specimens were obtained from 120 of 875 men in the Scandinavian Prostate Cancer Group-7 study. Results: Biopsies were performed at median of 45 months follow-up. In 63 patients receiving endocrine treatment only and 57 patients receiving combined treatment, residual cancer was found in 66% (n = 41) and 22% (n = 12), respectively (p < 0.0001). The vast majority of residual tumors were poorly differentiated (Gleason score {>=}8). Endocrine therapy alone was predictive of residual prostate cancer: odds ratio 7.49 (3.18-17.7), p < 0.0001. In patients with positive vs. negative biopsy the incidences of clinical events were as follows: biochemical recurrence 74% vs. 27% (p < 0.0001), local progression 26% vs. 4.7% (p = 0.002), distant recurrence 17% vs. 9.4% (p = 0.27), clinical recurrence 36% vs. 13% (p = 0.006), cancer-specific death 19% vs. 9.7% (p = 0.025). In multivariable analysis, biochemical recurrence was significantly associated with residual cancer: hazard ratio 2.69 (1.45-4.99), p = 0.002, and endocrine therapy alone hazard ratio 3.45 (1.80-6.62), p < 0.0001. Conclusions: Radiotherapy combined with hormones improved local tumor control in comparison with endocrine therapy alone. Residual prostate cancer was significantly associated with serum prostate-specific antigen recurrence, local tumor progression, clinical recurrence, and cancer-specific death in univariable analysis. Residual cancer was predictive of prostate-specific antigen recurrence in multivariable analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Nomogram to Predict the Risk of Acute Urinary Retention After I-125 Prostate Brachytherapy

Purpose: Acute urinary retention (AUR) after iodine-125 (I-125) prostate brachytherapy negatively influences long-term quality of life and therefore should be prevented. We aimed to develop a nomogram to preoperatively predict the risk of AUR. Methods: Using the preoperative data of 714 consecutive patients who underwent I-125 prostate brachytherapy between 2005 and 2008 at our department, we modeled the probability of AUR. Multivariate logistic regression analysis was used to assess the predictive ability of a set of pretreatment predictors and the additional value of a new risk factor (the extent of prostate protrusion into the bladder). The performance of the final model was assessed with calibration and discrimination measures. Results: Of the 714 patients, 57 patients (8.0%) developed AUR after implantation. Multivariate analysis showed that the combination of prostate volume, IPSS score, neoadjuvant hormonal treatment and the extent of prostate protrusion contribute to the prediction of AUR. The discriminative value (receiver operator characteristic area, ROC) of the basic model (including prostate volume, International Prostate Symptom Score, and neoadjuvant hormonal treatment) to predict the development of AUR was 0.70. The addition of prostate protrusion significantly increased the discriminative power of the model (ROC 0.82). Calibration of this final model was good. The nomogram showed that among patients with a low sum score (<18 points), the risk of AUR was only 0%-5%. However, in patients with a high sum score (>35 points), the risk of AUR was more than 20%. Conclusion: This nomogram is a useful tool for physicians to predict the risk of AUR after I-125 prostate brachytherapy. The nomogram can aid in individualized treatment decision-making and patient counseling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alignment Focus of Daily Image Guidance for Concurrent Treatment of Prostate and Pelvic Lymph Nodes

Purpose: To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. Methods and Materials: A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. Results: For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. Conclusion: For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗