Finite element analysis of a composite artificial ankle

Ultra-light carbon fiber composite materials are being utilized in artificial limbs with increasing frequency in recent years. Dr. Arthur Copes, an orthotist from Baton Rouge, Louisiana, has developed a graphite expoxy composite material artificial ankle (Copes/Bionic Ankle) that is intended to be used by amputees who require the most advanced above-and-below-the-knee prosthetic devices. The Copes/Bionic Ankle is designed to reproduce the function of the natural ankle joint by allowing the composite material to act as a spring mechanism without the use of metal mechanical parts. NASA Marshall Space Flight Center has agreed to participate in the design effort by providing the structural analysis of the artificial ankle design.

Perkins, Leigh Ann↗

Ultrasonic Inspection With Angular-Power-Spectrum Scanning

Principal advantage of angular-power-spectrum scanning (APSS) is that, unlike x-radiography and prior ultrasonic techniques, it reveals subtle distributions of microstructural features; e.g., variations in densities of micropores or regions in which fibers and matrices are poorly bonded to each other. Potential applications include development and characterization of composite-material components of large structures, such as buildings and bridges; determination of quality and detection of damage in fiberglass hulls, surfboards, ladders, and scaffolds; and development of porous prosthetic skins and complicated "smart" materials. Superposed diffraction patterns give clues to internal structural features of ceramic composites.

Generazio, Edward R.↗

Computed Flow Through An Artificial Heart Valve

Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

Rogers, Stewart E.↗

Image remapping strategies applied as protheses for the visually impaired

Maculopathy and retinitis pigmentosa (rp) are two vision defects which render the afflicted person with impaired ability to read and recognize visual patterns. For some time there has been interest and work on the use of image remapping techniques to provide a visual aid for individuals with these impairments. The basic concept is to remap an image according to some mathematical transformation such that the image is warped around a maculopathic defect (scotoma) or within the rp foveal region of retinal sensitivity. NASA/JSC has been pursuing this research using angle invariant transformations with testing of the resulting remapping using subjects and facilities of the University of Houston, College of Optometry. Testing is facilitated by use of a hardware device, the Programmable Remapper, to provide the remapping of video images. This report presents the results of studies of alternative remapping transformations with the objective of improving subject reading rates and pattern recognition. In particular a form of conformal transformation was developed which provides for a smooth warping of an image around a scotoma. In such a case it is shown that distortion of characters and lines of characters is minimized which should lead to enhanced character recognition. In addition studies were made of alternative transformations which, although not conformal, provide for similar low character distortion remapping. A second, non-conformal transformation was studied for remapping of images to aid rp impairments. In this case a transformation was investigated which allows remapping of a vision field into a circular area representing the foveal retina region. The size and spatial representation of the image are selectable. It is shown that parametric adjustments allow for a wide variation of how a visual field is presented to the sensitive retina. This study also presents some preliminary considerations of how a prosthetic device could be implemented in a practical sense, vis-a-vis, size, weight and portability.

Johnson, Curtis D.↗

Scientific American Inventions From Outer Space: Everyday Uses For NASA Technology

The purpose of this book is to present some of the inventions highlighted in the yearly publication of the National Aeronautics and Space Administration (NASA) Spinoff. These inventions cover a wide range, some of which include improvements in health, medicine, public safety, energy, environment, resource management, computer technology, automation, construction, transportation, and manufacturing technology. NASA technology has brought forth thousands of commercial products which include athletic shoes, portable x-ray machines, and scratch-resistant sunglasses, guidance systems, lasers, solar power, robotics and prosthetic devices. These products are examples of NASA research innovations which have positively impacted the community.

Baker, David↗

Keeping Cool in Extreme Heat

Through a partnership with Unitika Ltd., NASA's Langley Research Center created a foam based on high temperature resistant polyimide chemistry. Licensed non-exclusively to SORDAL, Inc., the low-density foam, named TEEK, can be processed into forms or used to fill structures such as honeycomb. TEEK offers superior insulation and support qualities, with heat and flame resistance abilities.TEEK is a practical selection for hull insulation in the shipbuilding industry, with numerous potential applications in aerospace applications, fire-resistant construction materials, and a wide range of consumer products that will improve safety and energy efficiency. Other opportunities are available in the areas of automotive coatings and sealants, electrical components, and recreational equipment. SORDAL has introduced its new product in several different forms, under the name "SOLREX". The company is developing a new product called SORDAL Paper(TM) that will be used in conjunction with the polyimide foam to offer thermal protection in various products, such as fire resistant garments and prosthetics.

Source record↗

Teeing Off With an Entirely New Material

Liquidmetal(R) alloy is part of an entirely new class of vitrified metals, and is also known as metallic glass, or Vitreloy(R). A vitrified metal is a frozen liquid that fails to crystallize during solidification, unlike common metals such as titanium, steel, and aluminum. The technology takes the non-crystalline structure of glass and combines it with the properties of metal, a combination not found in nature, allowing for a product that offers the strength of a metal with the elasticity of a polymer. This unique technology is more than twice as strong as titanium and has a higher elastic limit. Liquidmetal(R) Golf presents this space-age development in a complete line golf clubs. Clubs made with this technology have a lower vibration response along with a softer, more solid feel. Because less energy is absorbed by the club's head upon impact, more energy is transferred directly to the ball. Vitreloy has potential commercial uses in sporting equipment: tennis rackets, bicycle frames, and baseball bats. The material may find applications in the medical industry for the manufacturing of surgical instruments and prosthetics. The Liquidmetal alloy is projected to replace many high performance materials, such as titanium, in the industries of aerospace, defense, military, automotives, medical instrumentation, and sporting goods

Source record↗

Prototyping the Future

Advanced Ceramics Research (ACR) of Tucson, Arizona, researches transforming scientific concepts into technological achievement. Through the SBIR (Small Business Innovative Research) program, ACR developed a high pressure and temperature fused deposition system, a prototyping system that is known as extrusion freeform fabrication. This system is useful in manufacturing prosthetics. ACR also developed a three-dimensional rapid prototyping process in which physical models are quickly created directly from computer generated models. Marshall Space Flight Center also contracted ACR to fabricate a set of ceramic engines to be appraised for a solar thermal rocket engine test program.

Source record↗

Balance System

TherEx Inc.'s AT-1 Computerized Ataxiameter precisely evaluates posture and balance disturbances that commonly accompany neurological and musculoskeletal disorders. Complete system includes two-strain gauged footplates, signal conditioning circuitry, a computer monitor, printer and a stand-alone tiltable balance platform. AT-1 serves as assessment tool, treatment monitor, and rehabilitation training device. It allows clinician to document quantitatively the outcome of treatment and analyze data over time to develop outcome standards for several classifications of patients. It can evaluate specifically the effects of surgery, drug treatment, physical therapy or prosthetic devices.

Source record↗

Reliability Analysis of Brittle Material Structures - Including MEMS(?) - With the CARES/Life Program

Brittle materials are being used, or considered, for a wide variety of high tech applications that operate in harsh environments, including static and rotating turbine parts. thermal protection systems, dental prosthetics, fuel cells, oxygen transport membranes, radomes, and MEMS. Designing components to sustain repeated load without fracturing while using the minimum amount of material requires the use of a probabilistic design methodology. The CARES/Life code provides a general-purpose analysis tool that predicts the probability of failure of a ceramic component as a function of its time in service. For this presentation an interview of the CARES/Life program will be provided. Emphasis will be placed on describing the latest enhancements to the code for reliability analysis with time varying loads and temperatures (fully transient reliability analysis). Also, early efforts in investigating the validity of using Weibull statistics, the basis of the CARES/Life program, to characterize the strength of MEMS structures will be described as as well as the version of CARES/Life for MEMS (CARES/MEMS) being prepared which incorporates single crystal and edge flaw reliability analysis capability. It is hoped this talk will open a dialog for potential collaboration in the area of MEMS testing and life prediction.

Nemeth, Noel N.↗

Removal of Biologically Active Organic Contaminants using Atomic Oxygen

Biomedical devices that are to come into contact with living tissue, such as prosthetic and other implants for the human body and the containers used to store and transport them, are together cleaned of non-living, but biologically active organic materials, including endotoxins such as lipopolysaccharides, and assembled into a hermetically sealed package without recontamination. This is achieved by cleaning both the device and package components together in an apparatus, which includes a hermetically sealed chamber, in which they are contacted with atomic oxygen which biocleans them, by oxidizing the biologically active organic materials. The apparatus also includes means for manipulating the device and container and hermetically sealing the cleaned device into the cleaned container to form the package. A calibrated witness coupon visually indicates whether or not the device and container have received enough exposure to the atomic oxygen to have removed the organic materials from their surfaces. Gamma radiation is then used to sterilize the device in the sealed container.

Bruce A Banks↗

Biomaterials and Magnetic fields for Cancer Therapy

The field of biomaterials has emerged as an important topic in the purview of NASA s new vision of research activities in the Microgravity Research Division. Although this area has an extensive track record in the medical field as borne out by the routine use of polymeric sutures, implant devices, and prosthetics, novel applications such as tissue engineering, artificial heart valves and controlled drug delivery are beginning to be developed. Besides the medical field, biomaterials and bio-inspired technologies are finding use in a host of emerging interdisciplinary fields such as self-healing and self-assembling structures, biosensors, fuel systems etc. The field of magnetic fluid technology has several potential applications in medicine. One of the emerging fields is the area of controlled drug delivery, which has seen its evolution from the basic oral delivery system to pulmonary to transdermal to direct inoculations. In cancer treatment by chemotherapy for example, targeted and controlled drug delivery has received vast scrutiny and substantial research and development effort, due to the high potency of the drugs involved and the resulting requirement to keep the exposure of the drugs to surrounding healthy tissue to a minimum. The use of magnetic particles in conjunction with a static magnetic field allows smart targeting and retention of the particles at a desired site within the body with the material transport provided by blood perfusion. Once so located, the therapeutical aspect (radiation, chemotherapy, hyperthermia, etc.) of the treatment, now highly localized, can be implemented.

Ramachandran, Narayanan↗

Surgical evaluation of candidates for cochlear implants

The customary presentation of surgical procedures to patients in the United States consists of discussions on alternative treatment methods, risks of the procedure(s) under consideration, and potential benefits for the patient. Because the contents of the normal speech signal have not been defined in a way that permits a surgeon systematically to provide alternative auditory signals to a deaf patient, the burden is placed on the surgeon to make an arbitrary selection of candidates and available devices for cochlear prosthetic implantation. In an attempt to obtain some information regarding the ability of a deaf patient to use electrical signals to detect and understand speech, the Good Samaritan Hospital and Neurological Sciences Institute cochlear implant team has routinely performed tympanotomies using local anesthesia and has positioned temporary electrodes onto the round windows of implant candidates. The purpose of this paper is to review our experience with this procedure and to provide some observations that may be useful in a comprehensive preoperative evaluation for totally deaf patients who are being considered for cochlear implantation.

Non-NASA Center↗

In-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation

An in-line pressure-flow module for in vitro modelling of haemodynamics and biosensor validation has been developed. Studies show that good accuracy can be achieved in the measurement of pressure and of flow, in steady and pulstile flow systems. The model can be used for development, testing and evaluation of cardiovascular-mechanical-electrical anlogue models, cardiovascular prosthetics (i.e. valves, vascular grafts) and pressure and flow biosensors.

NASA Discipline Cardiopulmonary↗

Short-term hemodynamic performance of the mitral Carpentier-Edwards PERIMOUNT pericardial valve. Carpentier-Edwards PERIMOUNT Investigators

BACKGROUND: Although long-term durability data exist, little data are available concerning the hemodynamic performance of the Carpentier-Edwards PERIMOUNT pericardial valve in the mitral position. METHODS: Sixty-nine patients who were implanted with mitral PERIMOUNT valves at seven international centers between January 1996 and February 1997 consented to participate in a short-term echocardiography follow-up. Echocardiographs were collected at a mean of 600+/-133 days after implantation (range, 110 to 889 days); all underwent blinded core lab analysis. RESULTS: At follow-up, peak gradients were 9.09+/-3.43 mm Hg (mean, 4.36+/-1.79 mm Hg) and varied inversely with valve size (p < 0.05). The effective orifice areas were 2.5+/-0.6 cm2 and tended to increase with valve size (p = 0.08). Trace mitral regurgitation (MR) was common (n = 48), 9 patients had mild MR, 1 had moderate MR, none had severe MR. All MR was central (n = 55) or indeterminate (n = 3). No paravalvular leaks were observed. Mitral regurgitation flow areas were 3.4+/-2.8 cm2 and were without significant volumes. CONCLUSIONS: In this multicenter study, these mitral valves are associated with trace, although physiologically insignificant, central MR. Despite known echocardiographic limitations, the PERIMOUNT mitral valves exhibit similar hemodynamics to other prosthetic valves.

Clinical Trial↗

Chronic recording of regenerating VIIIth nerve axons with a sieve electrode

A micromachined silicon substrate sieve electrode was implanted within transected toadfish (Opsanus tau) otolith nerves. High fidelity, single unit neural activity was recorded from seven alert and unrestrained fish 30 to 60 days after implantation. Fibrous coatings of genetically engineered bioactive protein polymers and nerve guide tubes increased the number of axons regenerating through the electrode pores when compared with controls. Sieve electrodes have potential as permanent interfaces to the nervous system and to bridge missing connections between severed or damaged nerves and muscles. Recorded impulses might also be amplified and used to control prosthetic devices.

NASA Discipline Neuroscience↗

Development of a hydraulic model of the human systemic circulation

Physical and numeric models of the human circulation are constructed for a number of objectives, including studies and training in physiologic control, interpretation of clinical observations, and testing of prosthetic cardiovascular devices. For many of these purposes it is important to quantitatively validate the dynamic response of the models in terms of the input impedance (Z = oscillatory pressure/oscillatory flow). To address this need, the authors developed an improved physical model. Using a computer study, the authors first identified the configuration of lumped parameter elements in a model of the systemic circulation; the result was a good match with human aortic input impedance with a minimum number of elements. Design, construction, and testing of a hydraulic model analogous to the computer model followed. Numeric results showed that a three element model with two resistors and one compliance produced reasonable matching without undue complication. The subsequent analogous hydraulic model included adjustable resistors incorporating a sliding plate to vary the flow area through a porous material and an adjustable compliance consisting of a variable-volume air chamber. The response of the hydraulic model compared favorably with other circulation models.

NASA Program Biomedical Research and Countermeasur↗

A mechanical energy analysis of gait initiation

The analysis of gait initiation (the transient state between standing and walking) is an important diagnostic tool to study pathologic gait and to evaluate prosthetic devices. While past studies have quantified mechanical energy of the body during steady-state gait, to date no one has computed the mechanical energy of the body during gait initiation. In this study, gait initiation in seven normal male subjects was studied using a mechanical energy analysis to compute total body energy. The data showed three separate states: quiet standing, gait initiation, and steady-state gait. During gait initiation, the trends in the energy data for the individual segments were similar to those seen during steady-state gait (and in Winter DA, Quanbury AO, Reimer GD. Analysis of instantaneous energy of normal gait. J Biochem 1976;9:253-257), but diminished in amplitude. However, these amplitudes increased to those seen in steady-state during the gait initiation event (GIE), with the greatest increase occurring in the second step due to the push-off of the foundation leg. The baseline level of mechanical energy was due to the potential energy of the individual segments, while the cyclic nature of the data was indicative of the kinetic energy of the particular leg in swing phase during that step. The data presented showed differences in energy trends during gait initiation from those of steady state, thereby demonstrating the importance of this event in the study of locomotion.