Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Chemical engineering design of CO oxidation catalysts

How a chemical reaction engineer would approach the challenge of designing a CO oxidation catalyst for pulsed CO2 lasers is described. CO oxidation catalysts have a long history of application, of course, so it is instructive to first consider the special requirements of the laser application and then to compare them to the characteristics of existing processes which utilize CO oxidation catalysts. All CO2 laser applications require a CO oxidation catalyst with the following characteristics: (1) active at stoichiometric ratios of O2 and CO, (2) no inhibition by CO2 or other components of the laser environment, (3) releases no particulates during vibration or thermal cycling, and (4) long lifetime with a stable activity. In all applications, low consumption of power is desirable, a characteristic especially critical in aerospace applications and, thus, catalyst activity at low temperatures is highly desirable. High power lasers with high pulse repetition rates inherently require circulation of the gas mixture and this forced circulation is available for moving gas past the catalyst. Low repetition rate lasers, however, do not inherently require gas circulation, so a catalyst that did not require such circulation would be favorable from the standpoint of minimum power consumption. Lasers designed for atmospheric penetration of their infrared radiation utilize CO2 formed from rare isotopes of oxygen and this application has the additional constraint that normal abundance oxygen isotopes in the catalyst must not exchange with rare isotopes in the gas mixture.

Herz, Richard K.↗

Component variations and their effects on bipolar nickel-hydrogen cell performance

A 50 cell bipolar nickel-hydrogen battery was assembled to demonstrate the feasibility of constructing a high voltage stack of cells. Various component combinations were tested in this battery. The battery had approximately 1 ampere-hour of capacity and was constructed from components with an active area of 2" X 2". The components were parametrically varied to give a comparison of nickel electrodes, hydrogen electrodes, separators, fill procedures and electrolyte reservoir plate thicknesses. Groups of five cells were constructed using the same components; ten combinations were tested in all. The battery was thoroughly characterized at various change and discharge rates as well as with various pulse patterns and rates. Over a period of 1400 40% DOD LEO cycles some of the groups began to exhibit performance differences. In general, only separator variations had a significant effect on cell performance. It also appears that shunt currents may have been operating within the stack, resulting in electrolyte transfer from one cell to another, thus contributing to cell performance variations.

Manzo, Michelle A.↗

Kinetic study of the reaction CH (X 2Pi) + H2 yields CH2 (X 3B1) + H in the temperature range 372 to 675 K

The kinetics of the reversible reaction CH (X 2Pi) + H2 yields CH2 (X 3B1) + H at 372-675 K and total pressure 100 torr (mainly Ar) is investigated experimentally. The ground-state CH radicals are produced by photolysis of CHBr3 using 10-mJ 266-nm laser pulses (repetition rate 10 Hz) and monitored by measuring the fluorescence induced by a 429.8-nm dye laser, in the apparatus described by Berman et al. (1982) and Berman and Lin (1984). The results are presented in tables and graphs and characterized. The absolute rate constants for the forward and reverse reactions are determined, and their temperature dependence is given by Arrhenius expressions and formulas obtained in transition-state-theory calculations. The heat of formation of CH2 at 0 K is estimated (assuming that the recombination reaction CH2 + H has zero activation energy) as 92.6 + or - 0.5 kcal/mol.

Zabarnick, S.↗

General autonomic components of motion sickness

This report refers to a body of investigations directed toward the examination of autonomic nervous system responses to motion sickness. Heart rate, respiration rate, finger pulse volume, and basal skin resistance were measured on 127 men and women before, during, and after exposure to a nauseogenic rotating chair test. Significant changes in all autonomic responses were observed across the tests (p less than .05). Significant differences in autonomic responses among groups divided according to motion sickness susceptibility were also observed (p less than .05). Results suggest that the examination of autonomic responses as an objective indicator of motion sickness malaise is warranted and may contribute to the overall understanding of the syndrome.

Cowings, Patricia S.↗

Collection and analysis of specific ELINT Signal Parameters

This report was a followup to, Collection and Analysis of Specific ELINT Signal Parameters, DTIC A166507, 23 June 1985. The programs and hardware assembled for the above mentioned report were used to analyze two types of radar, the PPS-6 and the HOOD radars. The typical ELINT parameters of frequency, pulse width, and pulse repetition rate were collected and analyzed.

Wilson, Lonnie A.↗

Component variations and their effects on bipolar nickel-hydrogen cell performance

A 50 cell bipolar nickel-hydrogen battery was assembled to demonstrate the feasibility of constructing a high voltage stack of cells. Various component combinations were tested in this battery. The battery had approximately 1 ampere-hour of capacity and was constructed from components with an active area of 2 x 2 inches. The components were parametrically varied to give a comparison of nickel electrodes, hydrogen electrodes, separators, fill procedures and electrolyte reservoir plate thicknesses. Groups of five cells were constructed using the same components; ten combinations were tested in all. The battery was thoroughly characterized at various change and discharge rates as well as with various pulse patterns and rates. Over a period of 1400 40-percent DOD LEO cycles some of the groups began to exhibit performance differences. In general, only separator variations had a significant effect on cell performance. It also appears that shunt currents may have been operating within the stack, resulting in electrolyte transfer from one cell to another, thus contributing to cell performance variations.

Manzo, Michelle A.↗

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.↗

Estimations of ABL fluxes and other turbulence parameters from Doppler lidar data

Techniques for extracting boundary layer parameters from measurements of a short pulse CO2 Doppler Lidar are described. The radial velocity measurements have a range resolution of 150 m. With a pulse repetition rate of 20 Hz, it is possible to perform scannings in two perpendicular vertical planes in approx. 72 s. By continuously operating the Lidar for about an hour, one can extract stable statistics of the radial velocities. Assuming that the turbulence is horizontally homogeneous, the mean wind, its standard deviations, and the momentum fluxes were estimated. From the vertically pointing beam, the first, second, and third moments of the vertical velocity were also estimated. Spectral analysis of the radial velocities is also performed from which, by examining the amplitude of the power spectrum at the inertial range, the kinetic energy dissipation was deduced. Finally, using the statistical form of the Navier-Stokes equations, the surface heat flux is derived as the residual balance between the vertical gradient of the third moment of the vertical velocity and the kinetic energy dissipation.

Tzvi, Gal-Chen↗

Adaptive optics in coherent lidar wind measurements: A feasibility study

Laser Doppler radar (lidar) is widely used for remote sensing of wind velocities. Usable wavelengths for the laser are limited by the effects of atmospheric turbulence. An adaptive optical system is proposed to compensate for turbulence effects on signal power. The feasibility of an adaptive system is considered in light of the effects of speckle from the aerosol target. It is concluded that adaptive optics is a promising technique for improving the performance of a 2 micron lidar wind measurement system. The chief technical challenges are a laser that will give the required output and pulse repetition rate, a combined Hartmann sensor and heterodyne detector, and a suitable reconstruction algorithm.

Leland, Robert P.↗

A pulsed CO2 Doppler lidar for boundary layer monitoring

A monostatic, master oscillator power amplifier (MOPA), CO2 pulsed Doppler lidar was constructed and tested. The system is compact (120 x 60 cm), operates at high pulse repetition rates (greater than 1 kHz) and is intended for simultaneous Doppler/Differential Absorption Lidar (DIAL) monitoring of the planetary boundary layer. Details of the system design, hard target calibrations, and aerosol returns are presented.

Pearson, Guy N.↗

Dependence of hydrogen arcjet operation on electrode geometry

The dependence of 2 kW hydrogen arcjet performance on cathode to anode electrode spacing was evaluated at specific impulses of 900 and 1000 s. Less than 2 absolute percent change in efficiency was measured for the spacings tested which did not repeat the 14 absolute percent variation reported in earlier work with similar electrode designs. A different nozzle configuration was used to quantify the variation in hydrogen arcjet performance over an extended range of electrode spacing. Electrode gap variation resulted in less than 3 absolute percent change in efficiency. These null results suggested that electrode spacing is decoupled from hydrogen arcjet performance considerations over the ranges tested. Initial studies were conducted on hydrogen arcjet ignition. The dependence of breakdown voltage on mass flow rate and hydrogen arcjet ignition on rates of pulse repetition and pulse voltage rise were also included for comparison with previous results obtained using simulated hydrazine.

Pencil, Eric J.↗

Dependence of hydrogen arcjet operation on electrode geometry

The dependence of 2kW hydrogen arcjet performance on cathode to anode electrode spacing was evaluated at specific impulses of 900 and 1000 s. Less than 2 absolute percent change in efficiency was measured for the spacings tested which did not repeat the 14 absolute percent variation reported in earlier work with similar electrode designs. A different nozzle configuration was used to quantify the variation in hydrogen arcjet performance over an extended range of electrode spacing. Electrode gap variation resulted in less than 3 absolute percent change in efficiency. These null results suggested that electrode spacing is decoupled from hydrogen arcjet ignition. The dependence of breakdown voltage on mass flow rate and electrode agreed with Paschen curves for hydrogen. Preliminary characterization of the dependence of hydrogen arcjet ignition on rates of pulse repetition and pulse voltage rise were also included for comparison with previous results obtained using simulated hydrazine.

Pencil, Eric J.↗

Shaping Transmitted Pulses To Provide Synchronizing Signals

Report presents theoretical analysis of relationships among: shapes and bandwidths of data pulses in pulse-amplitude modulation (PAM) and quadrature amplitude modulation (QAM); pulse-repetition rates (baud rates); and presence or absence of sinusoidal baud-frequency components in envelopes (magnitudes) of overall received signals.

Satorius, Edgar H.↗

Generating Submillimeter-Wave Frequencies From Laser Pulses

Semiconductor photoconductive switches generate electrical pulses containing submillimeter-wavelength carrier signals (frequency between 300 and 3,000 GHz) and harmonics thereof when illuminated with short-rise-time pulses from lasers. Device of this type used as local oscilator in heterodyne submillimeter-wave receiver. Electrical output of device coupled via transmission line, waveguide, or antenna to mixer circuitry of receiver. Phase delays between optically activated semiconductor switches determine output carrier frequencies. N electrical pulses generated by each laser pulse. Thus, fundamental output frequency is N times laser-pulse-repetition rate.

Spencer, Michael G.↗

Effect of prolonged LBNP and saline ingestion on plasma volume and orthostatic responses during bed rest

Orthostatic intolerance remains a significant problem following space flight despite frequent use of the saline fluid-loading countermeasure and volitional use of an anti-gravity suite during reentry and landing. The purpose of this project is to examine the plasma volume (PV), endocrine, and orthostatic responses of bedrested subjects following 2-hr and 4-hr treatments of lower body negative pressure (LBNP) and saline ingestion. Ten healthy men were randomly assigned into 2 groups. Group A underwent a 4-hr LBNP/saline treatment on best rest day 5 and the 2-hr treatment on day 11. Group B underwent the 2-hr treatment on day 6 and the 4-hr treatment on day 10. Blood volume was determined before and after bed rest using radiolabelling. Changes in PV between measurements were calculated from changes in hematocrit and estimated red cell volume. Urinary excretion of anti-diuretic hormone (ADH) and aldosterone (ALD) were measured each day during the study. Orthostatic responses were measured using a ramp LBNP protocol before bed rest, before each treatment, and 24 hours after each treatment. Both 2-hr and 4-hr treatments resulted in a restoration of PV to pre-bed rest levels which persisted at least 24 hours. This increase in PV was associated with significant increases in urinary excretion of ADH and ALD. Twenty-four hours after the 4-hr treatment, the heart rate and pulse pressure response to LBNP were significantly lower and stroke volumes during LBNP were increased. Twenty-four hours after the 2-hr treatment, there was no evidence of improvement in orthostatic responses. These results suggest that a countermeasure which simply restores PV during space flight may not be sufficient for restoring orthostatic responses.

Fortney, Suzanne M.↗

In situ detection of tropospheric OH and HO2 by laser-induced fluorescence in a detection chamber at low pressure

Just as in the method of Hard and O'Brien, ambient air is pulled through an approximately 1 mm diameter inlet into a detection chamber that is maintained at a pressure of 2.4 torr. The ambient air stream travels through the detection chamber with a velocity of greater than 100 m sec(exp -1) in a narrow stream, constrained by the addition of an inert gas flow (0.4 torr). The OH molecule is both excited and detected in the A(exp 2)Sigma (v' = 0) yields X(exp 2)II (v'' = 0) transition at 308 nm. Light from a copper vapor-pumped dye laser (rep. rate = 10kHz; pulse length = 20 ns; linewidth = .1 cm(exp -1), and average power = 15 mW), resonant with the Q(sub 1)(3) transition, is multipassed through a White cell and intercepts the air stream as 24 non-overlapping 2mm by 5mm beams. A fast microchannel plate detector is turned off during the laser pulse to prevent saturation of the detector due to Rayleigh and chamber scattering. It is turned on 30-100 nsec after the end of the laser pulse for 300 ns to collect resonance fluorescence from OH. HO2 is detected by chemical conversion to OH by reaction with reagent NO, followed by OH detection. Both the detection sensitivity and the inlet characteristics must be understood for any in situ instrument. For the calibration of the detection sensitivity, OH is produced quantitatively by the fast H + NO2 yields OH + NO reaction in a low pressure, flowing discharge tube connected to the detection chamber. The inlet transmission of OH inlet is calibrated separately.

Brune, William H.↗

High Spectral Resolution Lidar Measurements Using an I2 Absorption Filter

The University of Wisconsin high spectral resolution lidar (HSRL) measures optical properties of the atmosphere by separating the Doppler-broadened molecular backscatter return from the unbroadened aerosol return. The HSRL was modified to use an I2 absorption cell The modified HSRL transmitter uses a continuously pumped, Q-switched, injection seeded, frequency doubled Nd:YAG laser operating at a 4 kHz pulse repetition rate. This laser is tunable over a 124 GHz frequency range by temperature tuning the seed laser under computer control.

Eloranta, E. W.↗

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗