Search NASA⌕ Search

SEARCH · Search NASA

Results for “PUMPS, FUEL - FAKIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Estimating Pump Blockage

Blockage predicted for all components including inducers, impellers and diffusers. Pump performance predicted by semiempirical method shows excellent agreement with test results in Space Shuttle main-engine highpressure fuel turbopump. Comparisons of pump efficiency show equally good agreement of calculated values with experimental ones. Method improves current estimation methods based solely on subjective engineering judgment.

Chung, W.↗

Effect of Viscosity on Fuel Leakage Between Lapped Plungers and Sleeves and on the Discharge from a Pump-Injection System

Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.

Rothrock, A M↗

Heat Pumps and the Electrification of Heating

70 to 80% of building energy load in Alaska is heating. About 81% of residential heating is supplied via on-site combustion of fossil fuels. How can heat pumps provide heat energy from renewable sources?

Alaska↗

Durability Study of a High-Pressure Common Rail Fuel Injection System Using Lubricity Additive-Dosed Gasoline-Like Fuel—Improved Endurance with Upgraded Hardware

Gasoline compression ignition (GCI) is a promising combustion technology that can help the commercial transportation sector achieve operational flexibility and meet upcoming criteria pollutant regulations. However, high-pressure fuel injection systems (>1000 bar) are needed to enable GCI and fully realize its benefits compared to conventional diesel combustion. This work is a continuation of previous durability studies that identified three key technical risks after running gasoline-like fuel through a heavy-duty, common rail injection system: (i) cavitation damage to the inlet check valve of the high-pressure pump, (ii) loss of injector fueling capacity, (iii) cavitation erosion of the injector nozzle holes. Upgraded hardware solutions were tested on a consistent 400- to 800-hour NATO durability cycle with the same gasoline-like fuel as previous studies. The upgraded pump showed no signs of abnormal wear or cavitation damage to the inlet check valve. In contrast to previous studies, there were no signs of pump performance degradation observed after 400 hours of testing. Material selection and design upgrades were also made to the injector which, only showed a 6.5% loss in fueling capacity after 800 hours of durability testing compared to 49.3% previously. Finally, geometric nozzle hole features such as higher inlet radius of curvature and higher K-factor were found to correlate with reduced cavitation erosion. However, mitigation of eccentric radial needle motion (i.e., wobble) is likely needed to further suppress cavitation. In general, the results from this study indicate there are viable hardware-based solutions for improving the endurance of high-pressure systems when running with gasoline-like fuel.

33 ADVANCED PROPULSION SYSTEMS↗

Incentivizing Cold-Climate Efficiency in Juneau (Final Report)

This is the final technical report for the DOE EERE BTO project Incentivizing Cold-Climate Efficiency in Juneau. The project implemented a community energy campaign to deploy heat pumps and efficiency for residents of Juneau, in Southeast Alaska. The project helped Juneau make progress towards its renewable energy goal of reaching 80% renewable energy for space heating by 2045. The Incentivizing Cold-Climate Efficiency in Juneau (ICE-Juneau) project began in 2020 and concluded three years later in 2023. During that time, a group of implementation partners and a research advisory team instituted a beneficial electrification campaign to promote energy savings and carbon reduction in residences of Juneau, Alaska. The campaign, Thermalize Juneau, focused on the installation of single head ductless mini-split heat pumps along with other efficiency upgrades. Thermalize Juneau was the first campaign of its kind in Alaska. After several months of planning, registration opened to the public in early 2021, and over the course of six months 164 participants enrolled. Campaign staff provided education to homeowners on heat pumps and efficiency, and each participant received a one-on-one heat pump assessment using a custom Microsoft Excel-based calculator that estimated energy savings for their residence based on building characteristics and past utility bills. Participants could also obtain a free energy audit from one of the two local energy auditors to further inform their decision. A heat pump installer, electrician, and builder were selected via a competitive RFP process. Participants who felt ready to install a heat pump or other efficiency upgrades received a site visit and custom quote from each of these contractors free of charge, and if they still felt energy upgrades were right for them, could move forward with an individual contract. Participants received a $400 heat pump installation rebate, offered by the installer if 40 heat pump installations occurred through the campaign. Overall, the campaign facilitated 75 heat pump installations (including participants that went with another contractor or heat pump model) and 30 efficiency upgrades (including participants that went with another builder or did DIY upgrades). The campaign created 3 new jobs as the heat pump installer hired an administrative assistant and two apprentices over the course of the campaign. It also helped Juneau work toward achieving its renewable energy goal of 80% renewable energy for space heating by 2045 by upgrading houses from fuel oil to heat pumps powered by the hydropower electric grid. Researchers conducted four surveys to inform Thermalize Juneau and future energy campaigns. The first surveyed existing and prospective heat pump owners in Juneau to identify barriers the campaign could address and inform recruitment efforts. Entry and exit surveys provided information on participant demographics, goals, outcomes, and suggestions for improving future campaigns. And a final survey of community members who had not participated in Thermalize Juneau gave insight on ways future campaigns could include a greater diversity of participants so they could realize similar benefits. Researchers also used pre-campaign energy modeling to predict energy savings, which was then compared to the savings estimated through aggregation of heat pump assessments and energy audits, and later to actual energy savings of 10 participants who installed a heat pump and were able to provide complete energy use data sets. In addition to energy savings, and to assist the electric utility in future planning efforts, researchers analyzed the overall change in electric use across participants with energy data and heat pump installations. They also completed a life cycle cost analysis, showing positive net present values for those displacing a fuel oil appliance, and a more mixed case for those switching from electric baseboard. This project proved the feasibility of energy campaigns, with a goal of beneficial electrification, in cold, remote locations. The Thermalize Juneau team compiled a Guidebook to Thermalize Campaigns, available online. In addition to documenting what occurred in Alaska’s first thermalize campaign, it provides tips and resources for other communities wishing to implement a similar program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tests of several bearing materials lubricated by gasoline

This investigation on the relative wear of several bearing materials lubricated by gasoline was conducted at the Langley Memorial Aeronautical Laboratory, as part of a general research on fuel injection engines for aircraft. The specific purpose of the work was to find a durable bearing material for gear pumps to be used for the delivery of gasoline and diesel engine fuel oil at moderate pressures to the high pressure pumps of fuel injection engines.

Joachin, W F↗

The impact of helium on plasma-driven hydrogen permeation and implications for direct internal recycling in the fusion fuel cycle

Abstract Metal foil pumps (MFPs) are the leading technology for direct internal recycling (DIR) of hydrogen isotopes from the plasma exhaust in future fusion plants. MFPs rely on the concept of superpermeation, where superthermal H atoms directly absorb into the metal foil, rapidly diffuse, and desorb downstream. To date, studies of superpermeation have predominantly employed either pure hydrogen or in some cases trace levels of impurities. The plasma exhaust is expected to contain just ∼1% helium, but in DIR the source gas would be enriched in helium as hydrogen isotopes are extracted. In this work, we explore the impact of helium on hydrogen superpermeation at low temperature (75 °C–200 °C) using Pd-based foils. To first order, the flux scaled linearly with the hydrogen mole fraction. Stable permeation was observed until the helium fraction reached ∼80%, where the flux began to decline slowly with time. In addition, short term (1–5 min) exposure to pure helium plasma significantly attenuated subsequent hydrogen plasma permeation, and the degree was more dramatic at elevated temperature. This attenuation was correlated with He retention in the foils, which was detected by time-of-flight secondary ion mass spectrometry at low levels (<0.1 at. %) and limited to the near surface (<10 nm). Similar trends were observed among all alloys (Pd, PdAg, PdCu), and the foils were restored to full performance with an Ar + sputter clean. The potential for helium plasma exposure to impact MFP performance under these conditions has not been previously reported, and these findings have significant implications to the design and implementation of practical DIR systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Passive fuel-Cell Surface power System (PaCeSS)

This effort produces a fully-passive surface power generation capability for fuel cell technology. The concept replaces the actively pumped thermal management of a state of the art (SOA) fuel cell/electrolyzer stack with a passive 2-phase thermosyphon for heat transport and a passive shape memory actuating radiator for temperature management. The concept addresses NASA fuel cell technology roadmap needs for greater reliability and longer operating life by eliminating life limiting elements of SOA fuel cell system design that drive failure modes associated with moving parts and control complexity. Applications map to surface power (primary fuel cell), surface energy storage (regenerable fuel cell) and in-situ resource utilization (electrolyzer/unitized reversible fuel cell). The first year of this effort concluded with independent demonstrations of 2-phase thermosyphon heat transport from a simulated fuel cell and temperature driven actuation of a shape memory actuating radiator. Results are in-character with underlying physics and demonstrate the potential to realize the objectives of this concept. his effort produces a fully-passive surface power generation capability for fuel cell technology. The concept replaces the actively pumped thermal management of a state of the art (SOA) fuel cell/electrolyzer stack with a passive 2-phase thermosyphon for heat transport and a passive shape memory actuating radiator for temperature management.

deionized water↗

Experimental findings from zero-tank net positive suction head operation of the J-2 hydrogen pump

The results of a series of liquid hydrogen turbopump tests to demonstrate the feasibility of zero-tank net positive suction head are presented. A J-2 engine hydrogen pump and S-IVB stage fuel feed system were used for this investigation. The pump was operated at flows and speeds equivalent to normal J-2 engine operating conditions and at hydrogen bulk temperatures between 39 and 45 R. These tests show zero-tank not positive suction head to be a realistic operating mode that should be considered for future applications.

Stinson, H. P.↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Coherent Anti-Stokes Raman Scattering (CARS) as a Probe for Supersonic Hydrogen-Fuel/Air Mixing

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic non-reacting fuel-air mixing experiment. Experiments were conducted in NASA Langley Research Center s Direct Connect Supersonic Combustion Test Facility. Under normal operation of this facility, hydrogen and air burn to increase the enthalpy of the test gas and O2 is added to simulate air. This gas is expanded through a Mach 2 nozzle and into a combustor model where fuel is then injected, mixes and burns. In the present experiment the O2 of the test gas is replaced by N2. The lack of oxidizer inhibited combustion of the injected H2 fuel jet allowing the fuel/air mixing process to be studied. CARS measurements were performed 427 mm downstream of the nozzle exit and 260 mm downstream of the fuel injector. Maps were obtained of the mean temperature, as well as the N2, O2 and H2 mean mole fraction fields. A map of mean H2O vapor mole fraction was also inferred from these measurements. Correlations between different measured parameters and their fluctuations are presented. The CARS measurements are compared with a preliminary computational prediction of the flow.

Danehy, P. M.↗

Advanced space transportation technologies

A wide range of propulsion technologies for space transportation are discussed in the literature. It is clear from the literature review that a single propulsion technology cannot satisfy the many mission needs in space. Many of the technologies tested, proposed, or in experimental stages relate to: chemical and nuclear fuel; radiative and corpuscular external energy source; tethers; cannons; and electromagnetic acceleration. The scope and limitation of these technologies is well tabulated in the literature. Prior experience has shown that an extensive amount of fuel needs to be carried along for the return mission. This requirement puts additional constraints on the lift off rocket technology and limits the payload capacity. Consider the possibility of refueling in space. If the return fuel supply is guaranteed, it will not only be possible to lift off more payload but also to provide security and safety of the mission. Exploration to deep space where solar sails and thermal effects fade would also be possible. Refueling would also facilitate travel on the planet of exploration. This aspect of space transportation prompts the present investigation. The particle emissions from the Sun's corona will be collected under three different conditions: in space closer to the Sun, in the Van Allen Belts; and on the Moon. It is proposed to convert the particle state into gaseous, liquid, or solid state and store it for refueling space vehicles. These facilities may be called space pump stations and the fuel collected as space fuel. Preliminary estimates of fuel collection at all three sites will be made. Future work will continue towards advancing the art of collection rate and design schemes for pumping stations.

Raj, Rishi S.↗

Development of Passive Fuel Cell Thermal Management Technology

The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA exploration program. The passive thermal management system relies on heat conduction within the cooling plate to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack rather than using a pumped loop cooling system to convectively remove the heat. Using the passive approach eliminates the need for a coolant pump and other cooling loop components which reduces fuel cell system mass and improves overall system reliability. Previous analysis had identified that low density, ultra-high thermal conductivity materials would be needed for the cooling plates in order to achieve the desired reductions in mass and the highly uniform thermal heat sink for each cell within a fuel cell stack. A pyrolytic graphite material was identified and fabricated into a thin plate using different methods. Also a development project with Thermacore, Inc. resulted in a planar heat pipe. Thermal conductivity tests were done using these materials. The results indicated that lightweight passive fuel cell cooling is feasible.

Burke, Kenneth A.↗

Alternative All-Metal Scroll Pump Design

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. There have been development efforts to design an all-metal scroll pump design alternative to the Normetex style. The first generation was fabricated out of machined stainless steel, but the thermal management and increased weight were not ideal. To mitigate the weight, an aluminum version was designed. The tritium holdup on untreated aluminum surfaces can be greater than stainless steel, so the wetted aluminum surfaces were electroless plated in nickel and then electroplated in gold. The development effort outlined in this report details the design of an improved version of the stainless steel version.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Size Up or Size Down? National Analysis of Heat Pump Sizing and Impacts

Electrification of on-site fossil fuel combustion in buildings is recognized as a key component of achieving global greenhouse gas emissions targets. Air-source heat pumps are an efficient approach for space heating electrification. However, a major barrier to heat pump adoption is the high installation cost relative to furnaces and air conditioners. Because the installation cost of heat pumps - especially cold climate models - is dependent on their size, it is important to understand the distribution of heat pump sizes using different sizing methods and factors that impact heat pump sizing. In this study, we use sub-hourly physics simulations of 550,000 statistically representative dwelling units to analyze the distribution of heat pump size in the U.S. for three different efficiency levels of heat pumps, with and without building insulation and air sealing upgrades. We will present results from the national analysis of different factors affecting heat pump sizing along with the impact of sizing decisions on upgrade costs and operating costs.

electrification↗