Search NASA⌕ Search

SEARCH · Search NASA

Results for “PWM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High-temperature brushless DC motor controller

A motor control system for deployment in high temperature environments includes a controller; a first half-bridge circuit that includes a first high-side switching element and a first low-side switching element; a second half-bridge circuit that includes a second high-side switching element and a second low-side switching element; and a third half-bridge circuit that includes a third high-side switching element and a third; low-side switching element. The motor controller is arranged to apply a pulse width modulation (PWM) scheme to switch the first half-bridge circuit, second half-bridge circuit, and third half-bridge circuit to power a motor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of lumen degradation and remaining useful life of LEDs using particle filter

With the development of light-emitting diode (LED) technology, light emitting diodes system is becoming a popular light source in daily life and industry area. It has shown that Led from same factory and work under same working condition, may have significantly different behavior. Therefore, it is very important to learn the fail mechanisms, especially in the case of safety critical and harsh environment application. This paper focus on a prognostic health management (PHM) method based on the measurement of forward voltage and forward current of bare LED under harsh environment. In this paper, experiment has been done with ten samples. Ten pristine bare LEDs have been tested at 85°C while simultaneously being subjected to 85% humid environment. Pulse width modulation (PWM) control method has been employed to drive the bare LED in order to reduce the heat effect caused by forward current and high frequency (300HZ) data acquisition has been used to measure the peak forward voltage and forward current. Test to failure (lumen drops to 70 percent) data has been measured to study the effects of high temperature and humid environment loadings on the bare LED. Also, solid state cooling method with peltier cooler has been used to control the temperature of LED in the integrating sphere when take the measurement of lumen flux. The shift of forward voltage forward current curve and lumen degradation has been recorded to help build the fail model and predicted the remaining useful life. In this method, particle filter has been employed to predict the remaining useful life (RUL) of the bare LED and give us a whole picture how Led system fails. Result shows that predication of remaining useful life of Led, made by the particle filter model works under reasonable limit, and hence this method can be employed to predict the failure of Led caused by thermal and humid stress under harsh environment.

42 ENGINEERING↗

Distributed control system for parallel-connected DC boost converters

The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Matrix converter operating in current control mode using feed forward signals

A matrix converter system having a current control mode operation is provided. The system includes a matrix converter having a switching matrix. The matrix converter is coupled at its low-voltage side to a generator and at its output load side to a load. A controller having a pulse width modulation (PWM) control circuit is configured to control the matrix converter via its switching matrix to increase energy within the internal inductances of the generator when the switching matrix causes a short circuit. A feed forward calculator is configured to calculate a feed forward output phase angle. The feed forward output phase angle is an estimation of an angle between an output current vector and an output voltage vector that represent feedback signals of current and voltage output by the matrix converter. The angular position of the voltage output vector is adjusted as a function of the feed forward output phase angle to align angular position or phase angle of the voltage output vector that represents the voltage output with a selected angular position or phase angle.

42 ENGINEERING↗

Unfolder-based single-stage AC-AC conversion system

An power converter includes an unfolder connected to a three-phase source and has an output connection with a positive terminal, a negative terminal and a neutral terminal. The unfolder creates two unipolar piece-wise sinusoidal DC voltage waveforms offset by a half of a period. A three-input converter connected to the unfolder produces a quasi-sinusoidal output voltage across output terminals. Switches of the converter selectively connect the positive, negative and neutral inputs across the output terminals. A PWM controller controls a first duty ratio and a second duty ratio for the converter based on a phase angle of the source and a modulation index generated from an error signal related to a control variable. The duty ratios are time varying with a fundamental frequency of the source. The modulation index relates to output voltage of the converter, peak voltage or current of the source and/or peak current at the output terminals.

Teeneti, Chakridhar Reddy↗

A New Approach to Robot Motor Control

This essay details the motor control improvements to Fermilab's Remote Viewing Robot (RVR). It is a robot tasked with remotely investigating issues within the accelerator tunnels at Fermilab. Initially controlled by a single Raspberry Pi that housed all the robot s operations, the RVR will now use a Raspberry Pi Pico W for its motor control. This was achieved using Pulse Width Modulation (PWM) to allow for precise speed and torque control for the robot. This enhances the robot s reliability. By addressing the challenge of navigating high radiation environments, the upgrade helps assist the RVR s goal of decreasing the need for human intervention in accelerator tunnels.

Lopez, Jacob↗

A Comparison of Battery Charge Controller Technologies for Wave Energy Converters: Preprint

Wave energy is a uniquely challenging field for electrical system designers. High peak and low average power potential with a constantly varying energy input is difficult to harness and control through conventional means. To power the blue economy, low-powered wave energy converters (WECs) need batteries for energy storage. Safely and effectively charging batteries from waves requires a charge controller to properly monitor and control voltage and current going to the battery. Currently, off-the-shelf charge controllers exist for other renewable generation such as wind, hydro, and solar. Two topologies were validated: a buck converter and a pulse width modulation (PWM) charge controller. Using an in-lab dry testbed, wave energy power inputs were simulated to properly validate the effectiveness of existing charge controller technologies, identifying the shortcomings and improvements needed to effectively harness wave energy.

battery storage↗

Solar-battery integrated DC system

A DC bus is connected to a PV array, a battery or both, to power a grid connected inverter load on the bus. A system and method is described for controlling current flow on a DC bus regardless of the type of inverter. A converter receives a DC battery voltage. A switching module controls current flow through the converter. A current generator generates a reference current in response to a reference voltage. A comparator connected at the output of the current generator compares the reference current with a battery current and outputs a signal to a controller. The controller generates a reference value. A PWM generator modulates the switch module to control current flow and energy flow between the DC bus and the battery. The current from the DC bus to the inverter is controlled to allow proper grid-connected operation regardless of inverter type.

Atcitty, Stanley↗

Digitally Controlled High Availability Power Supply

This paper reports the design and test results on novel topology, high-efficiency, and low operating temperature, 1,320-watt power modules for high availability power supplies. The modules permit parallel operation for N+1 redundancy with hot swap capability. An embedded DSP provides intelligent start-up and shutdown, output regulation, general control and fault detection. PWM modules in the DSP drive the FET switches at 20 to 100 kHz. The DSP also ensures current sharing between modules, synchronized switching, and soft start up for hot swapping. The module voltage and current have dedicated ADCs (>200 kS/sec) to provide pulse-by-pulse output control. A Dual CAN bus interface provides for low cost redundant control paths. Over-rated module components provide high reliability and high efficiency at full load. Low on-resistance FETs replace conventional diodes in the buck regulator. Saturable inductors limit the FET reverse diode current during switching. The modules operate in a two-quadrant mode, allowing bipolar output from complimentary module groups. Controllable, low resistance FETs at the input and output provide fault isolation and allow module hot swapping.

43 PARTICLE ACCELERATORS↗

Digitally Controlled High Availability Power Supply

This paper will report on the test results of a prototype 1320 watt power module for a high availability power supply. The module will allow parallel operation for N+1 redundancy with hot swap capability. The two quadrant output of each module allows pairs of modules to provide a 4 quadrant (bipolar) operation. Each module employs a novel 4 FET buck regulator arranged in a bridge configuration. Each side of the bridge alternately conducts through a small saturable ferrite that limits the reverse current in the FET body diode during turn off. This allows hard switching of the FETs with low switching losses. The module is designed with over-rated components to provide high reliability and better then 97% efficiency at full load. The modules use a Microchip DSP for control, monitoring, and fault detection. The switching FETS are driven by PWM modules in the DSP at 60 KHz. A Dual CAN bus interface provides for low cost redundant control paths. The DSP will also provide current sharing between modules, synchronized switching, and soft start up for hot swapping. The input and output of each module have low resistance FETs to allow hot swapping and isolation of faulted units.

42 ENGINEERING↗

Repurposing Inactive Oil and Gas Wells for Energy Storage: Maximizing the Potential Via Optimal Drivetrain Control: Preprint

In recent years, there has been a growing emphasis on utilizing energy storage to enhance grid resilience against disruptive events. While renewable energy supply continues to expand, gravity-based solutions like pumped hydro remain dominant in the commercial space. However, their geographical limitations constrain availability, scalability, and increase costs for co-locating solar and wind energy. An alternative approach proposes repurposing idle oil and gas wells located closer to existing grid infrastructure, offering a promising and cost-effective solution. This paper addresses the optimization and control of a regenerative drive system coupled to an interior permanent magnet synchronous machine in a 300-meter well with a 100-Newton weight. The study employs a dynamic MATLAB/Simulink model to simulate the operation of the electric drivetrain system during storage and discharge operations. The results demonstrate an initial round-trip efficiency of 85.9% for the electrical system alone and identify crucial factors for maximizing efficiency. The optimized operation and control of the electromechanical drivetrain system hold great potential for minimizing the levelized cost of storage while maximizing efficiency and revenue generation.

ENERGY STORAGE,ENGINEERING↗

Analytical Expression for DC Link Capacitor Current in a Cascaded H-Bridge Multi-Level Active Front-End Converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. The analytical results have been validated with detailed simulations and hardware results.

cascaded H-bridge, carrier-based PWM, dc-link capa↗

Decentralized Carrier Interleaving in Cascaded Multilevel DC-AC Converters: Preprint

Cascaded dc-ac converters with interleaved carriers are commonly used in applications where elevated voltages and low-distortion multilevel waveforms are needed. Example applications include modular multilevel converters and solid-state transformers. In such systems, carrier interleaving is generally achieved via communication among the stacked converters or a centralized controller. Due to the large number of converters in such a system, existing approaches entail significant wiring complexity and communication may limit resilience to failures. In this paper, we introduce a control strategy which achieves communication-free carrier interleaving among series-connected converters. The proposed controller is embedded within each converter control loop and only requires measurements available at each set of converter terminals. We formulate a dynamic system model and show that the system converges to the interleaved condition irrespective of the number of converters in the stack. After outlining a practical method for digital implementation, experiments are shown on a hardware-in-the-loop setup.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fixed switching frequency predictive control of an asymmetric source dual inverter system with a floating bridge for multilevel operation

In this study, we propose a modified modulated model predictive control (MMPC) scheme to control an open-end winding induction motor drive using an asymmetric source dual inverter with one floating bridge. The control algorithm uses a modulation algorithm within the cost function optimisation scheme to avoid variable switching frequency. The voltage of the floating capacitor is regulated utilising predefined redundant switching sequences as well as the voltage vector location is identified to improve calculation time. Lastly, the proposed MMPC scheme enhances the output performance with comparison to the model predictive control scheme. Experimental results are presented to verify theory and simulation results.

42 ENGINEERING↗

A Comprehensive Approach towards Multi-Objective EMI Filter Design Optimization in High-Frequency SiC-Based Motor Drives

With rapid penetration of high-frequency, highdensity power electronics into the industry, controlling the system generated EMI becomes one of the major design challenges. Designing practical optimized EMI filters require simultaneous consideration of multiple aspects - including electromagnetic couplings, magnetic materials, practical component parasitics and their impacts at high-frequencies, and also the overall manufacturing costs. The multi-dimensional nature of the problem often results in overcompensated designs that hurt the system efficiency and power density. This paper focuses on a comprehensive design platform (developed in MATLAB) towards designing high-density, optimized, highly efficient EMI filters by analyzing the generated noise spectrum and evaluating a vast array of potential solutions before outputting an optimized filter solution. The proposed tool includes database-based component selection, optimal topology selection, multistage filter design, overall optimization for volume, mass, cost and total loss. The proposed filter has been thoroughly evaluated in a PSIM simulation environment emulating the hardware in CRD300DA12EXM3, a 300kW three-phase inverter from Wolfspeed with an RL load representing a motor drive application. Furthermore, a 20kHz switching frequency is chosen and impacts of the motor high-frequency characteristics on the generated EMI noise spectrum of the overall system have been analyzed.

42 ENGINEERING↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration

This paper presents an innovative wave energy conversion system that integrates an interleaved Cuk converter with advanced nonlinear control for seamless grid integration. The system efficiently extracts power on the DC side using the interleaved Cuk converter, while an inverter manages power transfer to the grid or load on the AC side. A nonlinear control architecture, based on the Lyapunov energy function, ensures stable and optimal operation under varying wave conditions, effectively addressing the challenges of variability and unpredictability inherent in wave energy. The proposed system also incorporates features to enhance power quality and minimize losses, making it a robust solution for renewable energy integration. The system's effectiveness in harnessing wave energy and achieving smooth grid integration is validated through comprehensive computer simulations in MATLAB/Simulink, with case study results demonstrating its capabilities.

HYDRO ENERGY,TIDAL AND WAVE POWER↗