Search NASA⌕ Search

SEARCH · Search NASA

Results for “Partial Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High Temperature Corrosion of Silicon Carbide and Silicon Nitride in Water Vapor

Silicon carbide (SiC) and silicon nitride (Si3N4) are proposed for applications in high temperature combustion environments containing water vapor. Both SiC and Si3N4 react with water vapor to form a silica (SiO2) scale. It is therefore important to understand the durability of SiC, Si3N4 and SiO2 in water vapor. Thermogravimetric analyses, furnace exposures and burner rig results were obtained for these materials in water vapor at temperatures between 1100 and 1450 C and water vapor partial pressures ranging from 0.1 to 3.1 atm. First, the oxidation of SiC and Si3N4 in water vapor is considered. The parabolic kinetic rate law, rate dependence on water vapor partial pressure, and oxidation mechanism are discussed. Second, the volatilization of silica to form Si(OH)4(g) is examined. Mass spectrometric results, the linear kinetic rate law and a volatilization model based on diffusion through a gas boundary layer are discussed. Finally, the combined oxidation and volatilization reactions, which occur when SiC or Si3N4 are exposed in a water vapor-containing environment, are presented. Both experimental evidence and a model for the paralinear kinetic rate law are shown for these simultaneous oxidation and volatilization reactions.

Opila, E. J.↗

Vacuum leak detector features higher sensitivity

Technique for measuring partial pressures utilizes extremely large resonance scattering cross section of xenon at 1471 angstroms to scatter light in a vacuum cell. Output signal of ultraviolet-sensitive photodetector is proportional to the partial pressure and to the rate of inleakage of xenon probe gas.

Barrington, A. E.↗

Possibility to sound the atmospheric ozone by a radiosonde equipped with two temperature sensors, sensitive and non-sensitive to the long wave radiation

The sensitiveness of white coated thermistor sensors and non-sensitiveness of the gold coated over white thermistor sensors (which have been manufactured by a vacuum evaporation process) to long wave radiation were ascertained by some simple experiments in-room and also by analyses of some results of experimental soundings. From results of analyses on the temperature discrepancies caused by long wave radiation, the possibility to sound the atmospheric ozone partial pressure by a radiosonde equipped with two kinds of sensors, sensitive and non-sensitive to the long wave radiation was suggested, and the test results of the newly developed software for the deduction of ozone partial pressure in upper layers was also shown. However, it was found that the following is the necessary condition to realize the purpose. The sounding should be made by a radiosonde equipped with three sensors, instead of two, one being non-sensitive to the long wave radiation perfectly, and the other two also non-sensitive partially to the downward one, with two different angles of exposure upward. It is essential for the realization of the purpose to get two different values of temperature discrepancies simultaneously observed by the three sensors mentioned above and to avoid the troublesome effects of the upward long wave radiation.

Kitaoka, T.↗

Use of a nitrogen-argon plasma to improve adherence of sputtered titanium carbide coatings on steel

Friction and wear experiments on 440-C steel surfaces that had been RF-sputtered with titanium carbide when a small percentage of nitrogen was added to the plasma were conducted. X-ray photoelectron spectroscopy and X-ray diffraction were used to analyze the resultant coatings. Results indicate that a small partial pressure of nitrogen (about 0.5%) markedly improves the adherence, friction, and wear properties when compared with coatings applied on sputter-etched oxidized surfaces or in the presence of a small oxygen partial pressure. The improvements are related to the formation of an interface containing a mixture of the nitrides of titanium and iron, which are harder than their corresponding oxides.

Brainard, W. A.↗

International Space Station (ISS) Major Constituent Analyzer (MCA) On-Orbit Performance

The Major Constituent Analyzer (MCA) is an essential part of the International Space Station (ISS) environmental control and life support system. The analyzer provides continuous readout of the partial pressures of six gases, nitrogen (N2), oxygen (O2), hydrogen (H2), carbon dioxide (CO2), methane (CH4) and water vapor (H2O) in the various ISS US. on-orbit modules. Continuous readout of the partial pressures of these gases is critical to verifying safe operation of the Atmosphere Revitalization (AR) system, Atmosphere Control System (ACS), and crew safety for Airlock Extravehicular Activities (EVAs). The MCA encountered some operational interruptions since being launched to orbit on Flight 5A in February 2001. Electronic, software, and hardware modifications and on-orbit crew maintenance of the MCA were necessary to restore its capability. This paper describes the modifications and the on-orbit maintenance performed to return the MCA to operational status, including brief explanations of the MCA failures and the associated hardware and electronic modifications. Operational procedures that were required to return the MCA to operational status, and the more recent successes of supporting both Russian and U.S. ISS EVA preparations, are also discussed

Reysa, Richard↗

Study program to develop and evaluate die and container materials for the growth of silicon ribbons

The development and evaluation of proprietary coatings of pure silicon carbide, silicon nitride, and aluminum nitride on less pure hot pressed substrates of the respective ceramic materials, is described. Silicon sessile drop experiments were performed on coated test specimens under controlled oxygen partial pressure. Prior to testing, X-ray diffraction and SEM characterization was performed. The reaction interfaces were characterized after testing with optical and scanning electron microscopy and Auger electron spectroscopy. Increasing the oxygen partial pressure was found to increase the molten silicon contact angle, apparently because adsorbed oxygen lowers the solid-vapor interfacial free energy. It was also found that adsorbed oxygen increased the degree of attack of molten silicon upon the chemical vapor deposited coatings. Cost projections show that reasonably priced, coated, molten silicon resistant refractory material shapes are obtainable.

Addington, L. A.↗

Effect of nitrogen-containing plasma on adherence, friction, and wear of radiofrequency-sputtered titanium carbide coatings

Friction and wear experiments on 440C steel surfaces that were rf sputtered with titanium carbide when a small percentage of nitrogen was added to the plasma were conducted. Both X-ray photoelectron spectroscopy and X-ray diffraction were used to analyze the resultant coatings. Results indicate that the small partial pressure of nitrogen (approximately 0.5 percent) markedly improves the adherence, friction, and wear properties when compared with coatings applied to sputter-etched surfaces, oxidized surfaces, or in the presence of a small oxygen partial pressure. The improvements are related to the formation of an interface containing a mixture of the nitrides of titanium and iron, which are harder than their corresponding oxides.

Brainard, W. A.↗

Effect of Nitrogen Gas on the Lifetime of Carbon Nanotube Field Emitters for Electron-Impact Ionization Mass Spectrometry

The lifetime of a patterned carbon nanotube film is evaluated for use as the cold cathode field emission ionization source of a miniaturized mass spectrometer. Emitted current is measured as a function of time for varying partial pressures of nitrogen gas to explore the robustness and lifetime of carbon nanotube cathodes near the expected operational voltages (70-100 eV) for efficient ionization in mass spectrometry. As expected, cathode lifetime scales inversely with partial pressure of nitrogen. Results are presented within the context of previous carbon nanotube investigations, and implications for planetary science mass spectrometry applications are discussed.

Getty, Stephanie A.↗

Defect chemistry and characterization of Hg sub 1x Cd sub x Te

Single crystal samples of undoped and doped Hg sub 1-x Cd sub x Te were annealed at varying temperatures and partial pressures of Hg. Hall effect and mobility measurements were carried out on these samples after quenching to room temperature. Based on the variation of the carrier concentration and the carrier mobility as a function of the partial pressure of Hg temperature, and dopant concentration, defect models were established for the doped and the undoped crystals. These models indicate that the native acceptor defects in both Hg0.8Cd0.2Te and Hg0.6Cd0.4Te doubly ionized and the native donor defects are negligible in concentration, implying that p to n conversion in these alloys occurs due only to residual donors. Incorporation mechanism of copper, indium, iodine, and phosphorus were investigated. A large concentration of indium is found to be paired with the native acceptor defects. Results on crystals doped with phosphorus indicate that phosphorus behaves amphoterically, acting as a donor on Hg lattice sites and as an acceptor intersitially on Te lattice sites. A majority of the phosphorus is found to be present as neutral species formed from the pairing reaction between phosphorus on Hg lattice sites and phosphorus in interstitial sites. Equilibrium constants for the intrinsic excitation reaction, as well as for the incorporation of the different dopants and the native acceptor defects were established.

Vydyanath, H. R.↗

Improved adherence of T1C coatings to steel

Modified process for RF sputtering of titanium carbide coatings onto 440-C steel has resulted in improved adherence. Small partial pressure of nitrogen, approximately 0.5 percent, during first minutes of deposition markedby improved adherence, friction, and wear properties when compared with coatings applied on sputter-etched surfaces, or oxidized surfaces or in presence of small oxygen partial pressure. X-ray photoelectron spectroscopy and X-ray diffraction were used to characterize resultant coatings.

Brainard, W. A.↗

Evaluation of Ionic Liquids for Closed Air Revitalization

This document is the final report resulting from the work conducted by undergraduate students at the University of South Alabama during the 2018/2019 academic year and was prepared by the undergraduate students. As NASA pushes the boundaries further into space, the current technologies within the various life support systems must be improved upon. One such improvement is needed to the current air revitalization systems, specifically sorbents that can capture CO2 more effectively from enclosed habitats. Ionic liquids (ILs) have been considered as absorbents for flue gas, but little research has been done to test the ability of ILs at ambient pressures and relatively low concentration of CO2. The experiment outlined below utilizes the task-specific ionic liquid, tetramethylammonium taurinate (TMN), in a commercial off the shelf absorption system to capture CO2. The CO2 stream is combined with nitrogen to produce an inlet gas concentration relevant to close air revitalization applications. At an inlet gas flow with a CO2 partial pressure of 3.8 torr the system was capable of removing just under 97% of the inlet CO2. The concentration of CO2 in the outlet stream, partial pressure 0.16 torr, was less than that of atmospheric air. The duty required to separate the absorbed gas from the ionic liquid as well to cool the ionic liquid to be reintroduced to the column were acquired utilizing laboratory cooling/heating baths. These results show that TMN may be an efficient candidate for consideration in closed air revitalization.

Duck, Gerald↗

Ozone profiles above Palmer Station, Antarctica

NASA's Goddard Space Flight Center/Wallops Flight Facility conducted a series of 52 balloon-borne measurements of vertical ozone profiles over the National Science Foundation (NSF) research facility at Palmer Station, Antarctica (64 deg 46 S, 64 deg 3 W) between August 9 and October 24, 1987. High resolution measurements were made from ground level to an average of 10 mb. While much variation was seen in the profile amounts of ozone, it is clear that a progressive depletion of ozone occurred during the measurement period, with maximum depletion taking place in the 17 to 19 km altitude region. Ozone partial pressures dropped by about 95 percent in this region. Shown here are plotted time dependences of ozone amounts observed at 17 km and at arbitrarily selected altitudes below (13 km) and above (24 km) the region of maximum depletion. Ozone partial pressure at 17 km is about 150nb in early August, and has decreased to less than 10nb in the minimums in October. The loss rate is of the order of 1.5 percent/day. In summary, a progressive depletion in stratospheric ozone over Palmer Station was observed from August to October, 1987. Maximum depletion occurred in the 17 to 19 km range, and amounted to 95 percent. Total ozone overburden decreased by up to 50 percent during the same period.

Torres, Arnold L.↗

Simultaneous in situ Optical Monitoring Techniques during Crystal Growth of ZnSe by Physical Vapor Transport

ZnSe crystals grown in sealed ampoules by the physical vapor transport method were monitored in situ using three techniques, simultaneously. A Michelson interferometer was set-up to observe the growth rate and surface morphological evolution. An interference pattern (interferogram) is formed by the interaction between the reflection of a HeNe laser (632.8 nm wavelength) off the crystal-vapor interface and a reference beam from the same laser. Preliminary results indicate that the rate of growth/thermal-etching can be calculated using analog data acquisition and simple fringe counting techniques. Gross surface features may also be observed using a digital frame grabber and fringe analysis software. The second in situ technique uses optical absorption to determine the partial pressures of the vapor species. The Se2 and Zn vapor species present in the sealed ampoule absorb light at characteristic wavelengths. The optical absorption is determined by monitoring the light intensity difference between the sample and reference beams. The Se2 Partial pressure profile along the length of the ampoule was estimated from the vibronic absorption peaks at 340.5, 350.8, 361.3 and 379.2 nm using the Beer's law constants established in the calibration runs of pure Se. Finally, because the high temperature crystal growth furnace contains windows, in situ visual observation of the growing crystal is also possible. The use of these techniques not only permits in situ investigation of high temperature vapor growth of semiconductors, but also offers the potential for real time feed back on the growing crystal and allows the possibility of actively controlling the growth process.

Su, C.- H.↗

Transportation of volatile elements in thermally evolving planetesimals: An important role of metallic iron

Ordinary chondrites are considered to have experienced thermal metamorphism in small bodies. We are interested in behaviors of volatile elements in such a kind of thermally evolving planetesimals. Volatile elements generally have high vapor pressures at high temperature. In porous bodies, with a high gas permeability, volatile elements are transported efficiently over a long range. Behavior of volatile elements transported by permeable gas flow can be handled by an equation whose form is similar to that of the equation of thermal diffusion. We can follow transportation of heats and volatile elements in planetesimals, when parameters in these equations, initial conditions and chemical behavior of volatile elements are given. Recently, we discovered that nitrogen in equilibrated H-chondrites is mainly trapped in taenite (f.c.c. Fe-Ni), probably dissolved in interstitial sites. Fegley suggests that metallic iron cannot trap nitrogen in the solar nebula gas due to its very low nitrogen partial pressure. Approximately 1 bar of nitrogen pressure is required to explain the nitrogen content in taenite. We may expect high nitrogen gas partial pressure (possibly produced by vaporization of nitrogen-bearing solids such as organic materials) at the interior of thermally evolving planetesimals. Kinetic behavior of nitrogen in taenite suggests that it can easily be equilibrated with the ambient nitrogen gas at temperatures of approximately 500 C or higher. We consider that nitrogen is trapped in taenite through a nitrogen redistribution process occurred during the thermal metamorphic event.

Hashizume, K.↗

The effect of water on the thermal expansion behavior of FM5055 carbon phenolic

The effect of water on the thermal expansion behavior of FM5055 carbon phenolic is studied using a theory of mixtures approach. A partial pressure expression for the water constituent was obtained based upon certain assumptions regarding the thermodynamic state of water as it resides in the free volumes of the polymer. A simple constitutive model is used to simulate the polymer strain due to the application of the partial pressure of water. The resulting theory is applied to model the effect of moisture on the thermal expansion of FM5055 carbon phenolic specimens. The application of the theory results in calculated strains which were in close agreement with the measured strains.

Sullivan, Roy M.↗

First-Principles Study of Molecular Hydrogen Activation by Defects in Boron Nitride

Here, we used density functional theory simulations in combination with ab initio thermodynamics to determine the H 2 partial pressure (p H2 )-dependent energetics associated with H 2 activation and recovery at various defect sites in hexagonal boron nitride (h-BN). We found that some defects are very reactive with hydrogen, thereby definitely trapping hydrogen in defective h-BN. However, depending on hydrogen partial pressure, less reactive defect sites can be populated. Because of the lower binding capability of these sites, they would allow hydrogen to be recycled and recovered. For small defect sizes, we found that hydrogen preferentially binds to nitrogen sites by forming N–H bonds, and if no N sites are available then boron sites would be the next to bind hydrogen. Hydrogen dissociation via frustrated Lewis pair is found to be more favorable than forming only N–H bonds but only if the defect size is large enough to accommodate steric effects. For specific conditions such as T = 400 K, p H2 = 1 bar, and only considering one molecular H 2 per defect, three defects, namely, the N monovacancy, 3V(1B2N), and hexagonal 6V(3B3N) could play a role in both the activation and recycling of H 2 as they would be reacting enough to allow a favorable splitting of H 2 while not binding too strongly to allow its recovery. More broadly, a range of p H2 and hydrogen loading conditions were investigated for different types of defects and the finding suggests that p H2 could be used to fine-tune the Gibbs free energy of hydrogenation, thereby allowing several types of defects at different hydrogen loading contents to play a role in the activation/recovery process of H 2 in defective h-BN.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operation and testing of Mark 10 Mod 3 underwater breathing apparatus

Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.

Milwee, W. I., Jr.↗

Water Vapor Effects on Silica-Forming Ceramics

Silica-forming ceramics such as SiC and Si3N4 are proposed for applications in combustion environments. These environments contain water vapor as a product of combustion. Oxidation of silica-formers is more rapid in water vapor than in oxygen. Parabolic oxidation rates increase with the water vapor partial pressure with a power law exponent value close to one. Molecular water vapor is therefore the mobile species in silica. Rapid oxidation rates and large amounts of gases generated during the oxidation reaction in high water vapor pressures may result in bubble formation in the silica and nonprotective scale formation. It is also shown that silica reacts with water vapor to form Si(OH)4(g). Silica volatility has been modeled using a laminar flow boundary layer controlled reaction equation. Silica volatility depends on the partial pressure of water vapor, the total pressure, and the gas velocity. Simultaneous oxidation and volatilization reactions have been modeled with paralinear kinetics.

Opila, E. J.↗