Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Characteristics of differential charging of ATS-6

Thirteen days of data collected by the Auroral Particle Experiment onboard the ATS 6 were analyzed emphasizing peculiarities in the electron data attributed to differential charging. On one of these days the satellite was eclipsed by the earth at local midnight. Spectrograms were used to examine the data. It is concluded that differential charging is responsible for returning photoelectrons to the spacecraft up to a couple hundred eV, depending on the spacecraft charge. It is believed that the Minnesota experiment on ATS 6 is largely responsible for producing a potential barrier that returns particles and produces intense spon spots in the count rates.

Johnson, B.↗

Low intensity X-ray and gamma-ray spectrometer

A low intensity X-ray and gamma ray spectrometer for imaging, counting, and energy resolving of single invisible radiation particles is described. The spectrometer includes a converting device for converting single invisible radiation particles to visible light photons. Another converting device converts the visible light photons to photoelectrons. A fiber optics coupling device couples together the two converting devices. An intensifying device intensifies the photoelectrons by an average gain factor of between 10 to the 4th power and 10 to the 7th power. The tensifying device is an anti-ion feedback microchannel plate amplifier which is operated substantially below saturation. A displaying device displays the intensified photoelectrons. The displaying device 32 indicates the spatial position, number, and energy of the incoming single invisible radiation particles.

Yin, L. I.↗

Monte Carlo Simulations of Background Spectra in Integral Imager Detectors

Predictions of the expected gamma-ray backgrounds in the ISGRI (CdTe) and PiCsIT (Csl) detectors on INTEGRAL due to cosmic-ray interactions and the diffuse gamma-ray background have been made using a coupled set of Monte Carlo radiation transport codes (HETC, FLUKA, EGS4, and MORSE) and a detailed, 3-D mass model of the spacecraft and detector assemblies. The simulations include both the prompt background component from induced hadronic and electromagnetic cascades and the delayed component due to emissions from induced radioactivity. Background spectra have been obtained with and without the use of active (BGO) shielding and charged particle rejection to evaluate the effectiveness of anticoincidence counting on background rejection.

Armstrong, T. W.↗

Interstellar Pickup Hydrogen Observations from the Pioneer 10 and 11 Plasma Analyzers

The Pioneer 10 and 11 Ames plasma analyzers included off-angle integrating counters used for the first exploration of magnetospheric plasmas at Jupiter and Saturn. When summed over multi-day intervals during interplanetary cruise, at times of relatively constant solar wind speed during 1972 to 1977, the resulting count rates show a dependence on acceptance energies of the plasma analyzer deflection plates. The count rates could be produced by energetic charged particles, solar wind protons moving at a large angle to the bulk flow, and interstellar pickup ions. We interpret the more energetic of two peaks that are sometimes observed as the signature of interstellar pickup hydrogen. This peak is located at just below twice the solar wind speed (V(sub SW)), when near 3 AU heliocentric distance, decreasing to just above V(sub SW) as the heliocentric distance increases. Also, in the 8 to 12 AU range of heliocentric distances, we identify the pickup hydrogen signature as a shelf that ends at an edge located below 2V(sub SW). During these observations, the spacecraft longitude relative to the upstream interstellar flow changes roughly from 25 deg, to 155 deg at the larger heliocentric distance. The peak at the smaller heliocentric distances is most consistent with a velocity distribution that is a shell in phase space, with limited thickening as the pickup ions are assimilated into the solar wind flow.

Mihalov, J. D.↗

Auroral, Polar Cap, and Polar Cusp Modeling and Data Analysis for the IMAGE Mission and LENA Instrument

One of the chief mysteries in the LENA perigee pass data is the lack of an apparent auroral oval in the images. Another is that in some cases ENA are seen from any direction near the Earth regardless of the latitude of the spacecraft. These facts lead one to ask a fundamental question: Is the instrument responding to ENA primarily? One possible way to get out of the "ambiguity" of the data is to assume that at least part of the signal is produced by something other than ENA. The two main candidates for this "something else" are UV light and energetic charged particles. UV light could only effect the instrument when its fan shaped aperture points toward the source. The most intense of which will be the sun, with day glow being the second strongest and the auroral zone, the third. We can rule out UV light as a prime source of counts in the perigee pass data for the following reasons: 1) The perigee pass signal is different in form and much stronger than the sun pulse signal seen just before or just after perigee; 2) There is no indication of the auroral zone, which would produce at least two peaks in the counts versus spin phase curve; 3) Mike Colliers' analysis of the sun pulse signal shows that it varies with the flux of the solar wind and not with variations in the solar UV flux. Charge particles that enter the aperture of the instrument and produce counts would show up when the instrument looks in the direction from which they come. In all of the data I am analyzing voltages were being applied to the collimators so that most charged particles should have been excluded from the instrument but this effect could still show up where the flux of energetic particles is high enough. The most likely place would be in the auroral zone where energetic electrons and protons precipitate. If these particles are producing counts then they should be seen when the instrument looks in and near the zenith direction. In nearly all of the perigee passes the zenith direction is devoid of counts.

Wilson, Gordon R.↗

South Atlantic Anomaly Entry and Exit as Measured by the X-Ray Timing Explorer

The Rossi X-ray Timing Explorer (RXTE) carries instruments that must switch off high voltages (HV) when passing through the South Atlantic Anomaly (SAA). The High Energy X-ray Timing Experiment (HEXTE) contains a particle monitor that detects the increased particle flux associated with the SAA and autonomously reduces its voltage. The Proportional Counter Array (PCA) relies on uplinked predictions of SAA entry/exit times based on ephemeris data provided by the Flight Dynamics Facility. A third instrument, the All-Sky Monitor (ASM) also uses a predicted SAA model to reduce voltage when passing through the SAA. Data collected from the HEXTE particle monitor, as well as other instrument readings near the times of SAA entry/exit offer the potential for refining models of the boundaries of the SAA. The SAA has an increased particle flux which causes high rates of detection in the RXTE instruments designed to observe x-rays. The high counting rates could degrade the PCA if HV is not reduced during SAA passages. On the other hand, PCA downtime can be minimized and the science return can be optimized by having the best possible model of the SAA boundary. Thus, the PCA team planned an extensive effort during in-orbit checkout to utilize both the HEXTE particle monitor data and instrument counting rates to refine the model of the SAA boundary. The times of SAA entry and exit are compared with the definitive epemeris to determine the precise location (latitude and longitude) of the SAA boundary. Over time, the SAA and its perimeter were mapped. The RXTE Science Operations Center is continuously working to feed back the results of this effort into the science scheduling process, improving the SAA model as it affects the RXTE instruments, thus obtaining more accurate estimates of the SAA entry/exit times.

Smith, Evan↗

Upper limits for X-ray and energetic neutral particle emission from Jupiter - Voyager-1 results

The X-ray sensitivity of the low energy proton channels in the Low Energy Charged Particle (LECP) experiment and its directional measurements determined whether X-rays from Jupiter can be recognized as additional flux above background as Voyager 1 approached the planet. Between about 230 and about 100 R(J), a statistically significant count rate was detected interpreted as X-rays and/or neutral particles. Such an X-ray flux leads to estimates of precipitating electrons over the Jovian polar caps which are 200 times larger than over observed electron fluxes in the Io plasma torus.

Kirsch, E.↗

Particle acceleration due to shocks in the interplanetary field: High time resolution data and simulation results

Data were examined from two experiments aboard the Explorer 50 (IMP 8) spacecraft. The Johns Hopkins University/Applied Lab Charged Particle Measurement Experiment (CPME) provides 10.12 second resolution ion and electron count rates as well as 5.5 minute or longer averages of the same, with data sampled in the ecliptic plane. The high time resolution of the data allows for an explicit, point by point, merging of the magnetic field and particle data and thus a close examination of the pre- and post-shock conditions and particle fluxes associated with large angle oblique shocks in the interplanetary field. A computer simulation has been developed wherein sample particle trajectories, taken from observed fluxes, are allowed to interact with a planar shock either forward or backward in time. One event, the 1974 Day 312 shock, is examined in detail.

Kessel, R. L.↗

First Order Transport of a Cold Uniform Ellipsoid of Charge

A single particle has a 6-element phase space vector $s = (x, γv)$ where $γv =\frac{p}{m}$ s proportional to the relativistic momentum. The ellipsoid is represented by a 21-element vector $(s, C, V)$ where $s$ is the phase space location of the centroid. $C$ is the 3 × 3 covariance matrix defined by $C_{ij} = ⟨δx_iδx_j⟩$, where $δx$ is the distance of a particle from the centroid $x$. $C$ is symmetric so only counts as 6 elements of the overall vector. $V$ is a general 3 × 3 matrix that determines the velocity distribution in the bunch by $δ(γv) = Vδx$. In total this makes 6 + 6 + 9 = 21 elements.

43 PARTICLE ACCELERATORS↗

Cloud condensation nucleus counter by impactor sampling technique

Unlike typical CCN counters, this device counts the numbers of water droplets condensed on aerosol particles sampled on a microcover glass at various different relative humidities. The relative humidities ranged from 75 percent to a calculated value of 110 percent. A schematic of the apparatus is shown. The individual CCN can be identified in an optical micrograph and scanning electron micrograph and may be inspected for their chemical composition later.

Ohtake, T.↗

The function and response of an improved stratospheric condensation nucleus counter

An improved condensation nucleus counter (CNC) for use in the stratosphere is described. The University of Minnesota CNC (UMCNC) has a sequential saturator and condenser and uses n-butyl alcohol as the working fluid. The use of a coaxial saturator flow, with aerosol in the center and filtered, alcohol-laden air around it, speeds the response of this instrument and improves its stability as pressure changes. The counting efficiency has been studied as a function of particle size and pressure. The UMCNC provides an accurate measure of submicron aerosol concentration as long as the number distribution is not dominated by sub-0.02 micron diameter aerosol. The response of the UMCNC is compared with that of other stratospheric condensation nucleus counters, and the results of a (near) comparison with a balloon-borne condensation nucleus counter are presented. The UMCNC has operated 14 times on a NASA U-2 aircraft at altitudes from 8 to 21.5 km.

Wilson, J. C.↗

Small conductive particle sensor

An electrostatic conductive fiber detector is disclosed for use in detecting, counting and measuring the length of fibers down to 0.1 mm and below with increased accuracy and reliability over prior art devices. It can be used for detection of fibers suspending in a flowing gas, in a nonflowing gas, or in a vacuum and its accumulated counts over a period of time is essentially unaffected by velocity of the fibers being detected.

Taback, I.↗

Intensity oscillation of low energy solar particles observed on the IMP 7 satellite

Solar flare particles in the energy range from 125 to 160 KeV per charge were detected and analyzed by an electrostatic deflection vs energy instrument on board the Explorer 47 (IMP 7) satellite. On the basis of a harmonic analysis of the counting rates, an approximating formula is obtained for the fluctuation of the particle flux. The oscillation frequency varies from flare to flare and is of the order of approximately .002 per sec. The physical implications of the finding are discussed.

Fan, C. Y.↗

Fast Multipole Methods for Three-Dimensional N-body Problems

We are developing computational tools for the simulations of three-dimensional flows past bodies undergoing arbitrary motions. High resolution viscous vortex methods have been developed that allow for extended simulations of two-dimensional configurations such as vortex generators. Our objective is to extend this methodology to three dimensions and develop a robust computational scheme for the simulation of such flows. A fundamental issue in the use of vortex methods is the ability of employing efficiently large numbers of computational elements to resolve the large range of scales that exist in complex flows. The traditional cost of the method scales as Omicron (N(sup 2)) as the N computational elements/particles induce velocities at each other, making the method unacceptable for simulations involving more than a few tens of thousands of particles. In the last decade fast methods have been developed that have operation counts of Omicron (N log N) or Omicron (N) (referred to as BH and GR respectively) depending on the details of the algorithm. These methods are based on the observation that the effect of a cluster of particles at a certain distance may be approximated by a finite series expansion. In order to exploit this observation we need to decompose the element population spatially into clusters of particles and build a hierarchy of clusters (a tree data structure) - smaller neighboring clusters combine to form a cluster of the next size up in the hierarchy and so on. This hierarchy of clusters allows one to determine efficiently when the approximation is valid. This algorithm is an N-body solver that appears in many fields of engineering and science. Some examples of its diverse use are in astrophysics, molecular dynamics, micro-magnetics, boundary element simulations of electromagnetic problems, and computer animation. More recently these N-body solvers have been implemented and applied in simulations involving vortex methods. Koumoutsakos and Leonard (1995) implemented the GR scheme in two dimensions for vector computer architectures allowing for simulations of bluff body flows using millions of particles. Winckelmans presented three-dimensional, viscous simulations of interacting vortex rings, using vortons and an implementation of a BH scheme for parallel computer architectures. Bhatt presented a vortex filament method to perform inviscid vortex ring interactions, with an alternative implementation of a BH scheme for a Connection Machine parallel computer architecture.

Koumoutsakos, P.↗

Project environmental microbiology as related to planetary quarantine

The viability and dry heat resistance of indigenous microflora associated with small soil particles were investigated. An aluminum boat TDT CUP-TSA solid media system was developed for the analyses; a complete description of the technique is included. Data cited here were obtained using analyses of individual soil particles. Detailed particle viability profiles for dry heat effects were determined for Kennedy Space Center soil. At 110 C at least some particles retained viability through a heating period of between 8 and 16 hours. Single particles heated at 125 C for 80 minutes or longer did not show evidence of viability under test conditions. Preliminary aerobic, mesophilic plate counts of the 74-88 micron m soil fraction yielded mean values of 16.2 organisms per dark particle and 2.6 organisms per light particle. Heat treatment of particles in a dry atmosphere did not appear to increase the rate of inactivation for in situ soil particle microflora.

Pflug, I. J.↗

CMOS Charged Particle Spectrometers

Integrated circuits manufactured in CMOS technology, have been developed as diffusion-based charged particle spectrometers for space applications. A four-chip spectrometer designed to count protons and heavier ions was flown on the Clementine spacecraft, and the spectrometer proton response is compared to GOES-6 proton data for the 21 Feb. 1994 solar proton event.

charged↗

Performance and operating envelope of imaging and scattering particle sizing instruments

Scattering and imaging type particle sizing instruments are analyzed in terms of their ability to make accurate determinations of particle size distributions, number density, and total mass. Sources of counting and sizing errors are explained. Ways are described of identifying these errors and how these errors can effect the measurements.

Hovenac, Edward A.↗