Search NASA⌕ Search

SEARCH · Search NASA

Results for “Passive flow control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Dynamics of active liquid interfaces

Controlling interfaces of phase-separating fluid mixtures is key to the creation of diverse functional soft materials. Traditionally, this is accomplished with surface-modifying chemical agents. Using experiment and theory, we studied how mechanical activity shapes soft interfaces that separate an active and a passive fluid. Chaotic flows in the active fluid give rise to giant interfacial fluctuations and noninertial propagating active waves. At high activities, stresses disrupt interface continuity and drive droplet generation, producing an emulsion-like active state composed of finite-sized droplets. When in contact with a solid boundary, active interfaces exhibit nonequilibrium wetting transitions, in which the fluid climbs the wall against gravity. These results demonstrate the promise of mechanically driven interfaces for creating a new class of soft active matter.

Science & Technology - Other Topics↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Entry Dispersion Analysis for the Stardust Comet Sample Return Capsule

Stardust will be the first mission to return samples from beyond the Earth-Moon system. The sample return capsule, which is passively controlled during the fastest Earth entry ever, will land by parachute in Utah. The present study analyzes the entry, descent, and landing of the returning sample capsule. The effects of two aerodynamic instabilities are revealed (one in the high altitude free molecular regime and the other in the transonic/subsonic flow regime). These instabilities could lead to unacceptably large excursions in the angle-of-attack near peak heating and main parachute deployment, respectively. To reduce the excursions resulting from the high altitude instability, the entry spin rate of the capsule is increased. To stabilize the excursions from the transonic/subsonic instability, a drogue chute with deployment triggered by an accelerometer and timer is added prior to main parachute deployment. A Monte Carlo dispersion analysis of the modified entry (from which the impact of off-nominal conditions during the entry is ascertained) shows that the capsule attitude excursions near peak heating and drogue chute deployment are within Stardust program limits. Additionally, the size of the resulting 3-sigma landing ellipse is 83.5 km in downrange by 29.2 km in crossrange, which is within the Utah Test and Training Range boundaries.

Desai, Prasun N.↗

Evaluation of advanced component concepts for an integrated environmental control/life support, resistojet control system

Flow restricting devices were studied for their suitability as liquid water propellant flow limiters for the biowaste resistojet. Flow limiting during the start-up transient is required to prevent thrustor instabilities and icing which could result in heater failure in the electrical resistance heated thrustor (resistojet). The study was directed toward simple devices which would function passively (i.e., without power except from the propellant flow itself), and would offer high reliability and simplicity. In addition to the flow limiting devices, a thermal pumping system was studied to determine whether CO2, desorbed from molecular sieves could be pumped thermally in a space station application. The thermal pump is considered a possible replacement for mechanical pumps. It involves a cyclic, constant volume cryopumping system which employs space radiators to achieve the cryotemperatures. The frozen CO2 would be vaporized periodically, using a waste heat loop, to attain sufficient pressure to transfer a large portion of the trapped CO2 to storage tanks.

Halbach, C. R.↗

Assimilation of Sentinel 1 and SMAP – Based Satellite Soil Moisture Retrievals into SWAT Hydrological Model: the Impact of Satellite Revisit Time and Product Spatial Resolution on Flood Simulations in Small Basins

In runoff generation process, soil moisture plays an important role as it controls the magnitude of the flood events to the rainfall inputs. In this study, we investigated the ability of a new era of satellite soil moisture retrievals to improve the Soil & Water Assessment Tool (SWAT) daily discharge simulations via soil moisture data assimilation for two small (< 500 km2) and hydrologically different catchments located in Central Italy. We ingested 1) the Soil Moisture Active and Passive (SMAP) Enhanced L3 Radiometer Global Daily 9 km EASE-Grid soil moisture, 2) the Advanced SCATterometer (ASCAT) H113 soil moisture product released within the EUMETSAT Satellite Application Facility on Support to Operational Hydrology and Water Management (H-SAF) which has a nearly daily temporal resolution and sampling of 12.5 km, and 3) a fused ASCAT/Sentinel-1 (S1) satellite soil moisture product named SCATSAR-SWI with temporal and spatial sampling of 1 day and 1 km, respectively into SWAT hydrological model via Ensemble Kalman Filter (EnKF). Different configurations were tested with the aim of exploring the effect of the hydrological regime, the land use conditions, the spatial sampling and the revisit time of the products (which controls the amount of available data to be potentially ingested). Results show a general improvement of SWAT discharge simulations for all products in terms of error and Nash Sutcliffe efficiency index. In particular, we found a relatively good behavior of both the active and the passive products in terms of low flows improvement especially for the catchment characterized by a higher baseflow component. The benefit of the higher spatial resolution of SCATSAR obtained via S1 over ASCAT was small likely due to very challenging areas for S1 retrieval. Eventually, better performances were obtained for the passive product in the more forested catchment. With the aim of exploring the benefit of having more frequent satellite soil moisture observations to be ingested, we tested the performance of the ASCAT product with a reduced temporal sampling obtained by temporally matching ASCAT observations to that of SMAP. The results show a significant reduction of the performance of ASCAT, suggesting that the correction frequency (due to the higher number of observations available) for small catchments is an important aspect for improving flood forecasting as it helps to adjust more frequently the soil moisture pre-storm conditions.

Small basins↗

Assimilation of Sentinel 1 and SMAP–based satellite soil moisture retrievals into SWAT hydrological model: the impact of satellite revisit time and product spatial resolution on flood simulations in small basins

In runoff generation process, soil moisture plays an important role as it controls the magnitude of the flood events in response to the rainfall inputs. In this study, we investigated the ability of a new era of satellite soil moisture retrievals to improve the Soil & Water Assessment Tool (SWAT) daily discharge simulations via soil moisture data assimilation for two small (< 500 km2) and hydrologically different catchments located in Central Italy. We ingested 1) the Soil Moisture Active and Passive (SMAP) Enhanced L3 Radiometer Global Daily 9 km EASE-Grid soil moisture, 2) the Advanced SCATterometer (ASCAT) H113 soil moisture product released within the EUMETSAT Satellite Application Facility on Support to Operational Hydrology and Water Management (HSAF) which has a nearly daily temporal resolution and sampling of 12.5 km, and 3) a fused ASCAT/Sentinel-1 (S1) satellite soil moisture product named SCATSAR-SWI with temporal and spatial sampling of 1 day and 1 km, respectively into SWAT hydrological model via the Ensemble Kalman Filter (EnKF). Different configurations were tested with the aim of exploring the effect of the hydrological regime, the land use conditions, the spatial sampling and the revisit time of the products (which controls the amount of available data to be potentially ingested). Results show a general improvement of SWAT discharge simulations for all products in terms of error and Nash Sutcliffe efficiency index. In particular, we found a relatively good behavior of both the active and the passive products in terms of low flows improvement especially for the catchment characterized by a higher baseflow component. The benefit of the higher spatial resolution of SCATSAR-SWI obtained via S1 over ASCAT was small, likely due to very challenging areas for the S1 retrieval. Eventually, better performances were obtained for the passive product in the more forested catchment. With the aim of exploring the benefit of having more frequent satellite soil moisture observations to be ingested, we tested the performance of the ASCAT product with a reduced temporal sampling obtained by temporally matching ASCAT observations to that of SMAP. The results show a significant reduction of the performance of ASCAT, suggesting that the correction frequency (due to the higher number of observations available) for small catchments is an important aspect for improving flood forecasting as it helps to adjust more frequently the pre-storm soil moisture conditions.

Shima Azimi↗

Seasonal mixing from intermittent flow drives concentration-discharge behaviour in a stream affected by coal mine drainage

Abandoned mining operations continue to severely degrade many ecosystems worldwide by releasing acidic water and/or heavy metals into surface and groundwater. Contaminant concentrations in affected streams vary with discharge in patterns that reflect both geochemical reactions and variable mixing of contaminated and non-contaminated waters. However, controls on concentration-discharge (C-Q) patterns remain unclear, particularly for constituents that experience changing solubility across redox and pH gradients. Understanding the C-Q behaviour of contaminants aids in predicting both downstream transport and effects on aquatic life under variable flow. Here, we examined the C-Q behaviours of non-reactive (Na, K, Ca, Mg, Cl - ) and reactive (Fe, Mn, Al, H + , SO 4 2- ) solutes in a stream contaminated with acid mine drainage in northeastern Ohio, USA. Concentration-discharge patterns at the watershed outlet primarily reflected mixing of contaminated baseflow with intermittent inputs of high pH water draining from a passive limestone treatment system into the stream. The treatment system acted as an ephemeral tributary that mitigated contamination in the stream by diluting solutes, raising pH, and driving metal precipitation, but only when flow was present during wet seasons. Consequently, AMD-derived reactive solutes (H + , Fe, Mn, Al) decreased with increasing stream discharge while relatively conservative solutes (e.g., Ca, Mg, K, Na) decreased only slightly or were chemostatic. This study highlights both the unique C-Q patterns of reactive solutes when compared to those of non-reactive solutes and the potential for intermittent streams to control C-Q behaviour in headwater catchments.

58 GEOSCIENCES↗

Investigation of passive shock wave-boundary layer control for transonic airfoil drag reduction

The passive drag control concept, consisting of a porous surface with a cavity beneath it, was investigated with a 12-percent-thick circular arc and a 14-percent-thick supercritical airfoil mounted on the test section bottom wall. The porous surface was positioned in the shock wave/boundary layer interaction region. The flow circulating through the porous surface, from the downstream to the upstream of the terminating shock wave location, produced a lambda shock wave system and a pressure decrease in the downstream region minimizing the flow separation. The wake impact pressure data show an appreciably drag reduction with the porous surface at transonic speeds. To determine the optimum size of porosity and cavity, tunnel tests were conducted with different airfoil porosities, cavities and flow Mach numbers. A higher drag reduction was obtained by the 2.5 percent porosity and the 1/4-inch deep cavity.

Nagamatsu, H. T.↗

Unconventional colloidal aggregation in chiral bacterial baths

Abstract When in equilibrium, thermal forces agitate molecules, which then diffuse, collide and bind to form materials. However, the space of accessible structures in which micron-scale particles can be organized by thermal forces is limited, owing to the slow dynamics and metastable states. Active agents in a passive fluid generate forces and flows, forming a bath with active fluctuations. Two unanswered questions are whether those active agents can drive the assembly of passive components into unconventional states and which material properties they will exhibit. Here we show that passive, sticky beads immersed in a bath of swimmingEscherichia colibacteria aggregate into unconventional clusters and gels that are controlled by the activity of the bath. We observe a slow but persistent rotation of the aggregates that originates in the chirality of theE. coliflagella and directs aggregation into structures that are not accessible thermally. We elucidate the aggregation mechanism with a numerical model of spinning, sticky beads and reproduce quantitatively the experimental results. We show that internal activity controls the phase diagram and the structure of the aggregates. Overall, our results highlight the promising role of active baths in designing the structural and mechanical properties of materials with unconventional phases.

Physics↗

Investigation to optimize the passive shock wave-boundary layer control for supercritical airfoil drag reduction

The optimization of passive shock wave/boundary layer control for supercritical airfoil drag reduction was investigated in a 3 in. x 15.4 in. Transonic Blowdown Wind Tunnel. A 14% thick supercritical airfoil was tested with 0%, 1.42% and 2.8% porosities at Mach numbers of .70 to .83. The 1.42% case incorporated a linear increase in porosity with the flow direction while the 2.8% case was uniform porosity. The static pressure distributions over the airfoil, the wake impact pressure data for determining the profile drag, and the Schlieren photographs for porous surface airfoils are presented and compared with the results for solid-surface airfoils. While the results show that linear 1.42% porosity actually led to a slight increase in drag it was found that the uniform 2.8% porosity can lead to a drag reduction of 46% at M = .81.

Nagamatsu, H. T.↗

Turbulent drag reduction research

Research in the area of turbulent drag reduction for attached flows is summarized. The most promising passive techniques utilize non-planar geometry. Of particular interest is the suitability of these devices for retrofit of existing vehicles. Five methods for reducing turbulent skin friction drag on bodies/fuselages are discussed. They are: (1) large-eddy breakup devices; (2) riblets; (3) slot injection optimization; (4) control of Emmons spot generation; and (5) relaminarization through massive suction. Except for the Emmons spot work these methods all indicate the possibility of sizable net reductions in skin friction for laboratory conditions.

Bushnell, D. M.↗

The passive control of compressible boundary layer growth by boundary layer trips

The passive control of compressible boundary layer growth by boundary layer trips has been studied experimentally. Axisymmetric trips and three dimensional trips were used in this study. The nomial freestream Mach numbers are 1.5 and 4. The results show that trips are effective in promoting boundary layer growth. Trips are more effective for Mach 1.5 flows than for Mach 4 flows.

Chou, J. H.↗

Enhanced Synchronization Stability of Grid-Forming Inverters With Passivity-Based Virtual Oscillator Control

In this article, a passivity-based virtual oscillator control strategy with enhanced synchronization stability for grid-forming inverters (GFMs) is proposed. By adopting the port-controlled Hamiltonian system theory for orbital stabilization problems, an energy pumping-and-damping block is proposed to render GFMs globally asymptotically stable with respect to the prespecified solutions of the power-flow equations from any initial condition. This allows for stable integrations of GFMs to any other globally asymptotically stable systems without their explicit knowledge, e.g., helping maintain synchronism with the bulk power system in a wide range of short-circuit-ratio conditions or under large disturbances and keeping synchronism among multiple GFMs in power systems. Herein, both simulations and experiments are presented to demonstrate the proposed control approach.

42 ENGINEERING↗

The effects of SO 2 exposure on three-way catalysts for passive SCR operation

We report efficient lean-burn gasoline engines cannot employ traditional three-way catalysts (TWCs) to control NO X emissions due to excess oxygen. Passive selective catalytic reduction (pSCR) is a process designed to control NOx by generating NH 3 over the TWC during fuel-rich operation, storing it on a downstream SCR, and then converting NOx during fuel-lean operation. This work is focused on studying sulfur effects on this promising strategy. Two hydrothermally-aged commercial catalysts were studied for their effectiveness in the presence of SO 2 : a Pd-based TWC and a TWC with NO X storage. The sulfated samples were evaluated in a flow reactor under pSCR conditions and with targeted reactions. SO 2 inhibited the water gas shift and steam reforming reactions, decreasing (but not eliminating) NH 3 production; however, initial activity is recoverable after a simple thermal treatment at 650 °C. This work will prove valuable in understanding, mitigating, and even reversing the effects of SO 2 inhibition on real pSCR systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of 12 days exposure to simulated microgravity on central circulatory hemodynamics in the rhesus monkey

Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.

NASA Discipline Cardiopulmonary↗

A Source-Term Based Boundary Layer Bleed/Effusion Model for Passive Shock Control

A modeling framework for boundary layer effusion has been developed based on the use of source (or sink) terms instead of the usual practice of specifying bleed directly as a boundary condition. This framework allows the surface boundary condition (i.e. isothermal wall, adiabatic wall, slip wall, etc.) to remain unaltered in the presence of bleed. This approach also lends itself to easily permit the addition of empirical models for second order effects that are not easily accounted for by simply defining effective transpiration values. Two effusion models formulated for supersonic flows have been implemented into this framework; the Doerffer/Bohning law and the Slater formulation. These models were applied to unit problems that contain key aspects of the flow physics applicable to bleed systems designed for hypersonic air-breathing propulsion systems. The ability of each model to predict bulk bleed properties was assessed, as well as the response of the boundary layer as it passes through and downstream of a porous bleed system. The model assessment was performed with and without the presence of shock waves. Three-dimensional CFD simulations that included the geometric details of the porous plate bleed systems were also carried out to supplement the experimental data, and provide additional insights into the bleed flow physics. Overall, both bleed formulations fared well for the tests performed in this study. However, the sample of test problems considered in this effort was not large enough to permit a comprehensive validation of the models.

Baurle, Robert A.↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Zero-Boil-Off Tank (ZBOT) Experiment: Ground-Based Validation of Self-Pressurization and Pressure Control Two-Phase CFD Model

Integral to all phases of NASA's projected space and planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. Cryogen vaporization due to heat leaks into the tank from its surroundings and support structure can cause self-pressurization relieved through venting. This has led to a desire to develop innovative pressure control designs based on mixing of the bulk tank fluid together with some form of active or passive cooling to allow storage of the cryogenic fluid with zero or reduced boil-off. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small scale tank pressurization and pressure control experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. The hardware for ZBOT-1 flew to ISS on the OA-7 flight in April 2017 and operations are planned to begin in September 2017, encompassing more than 90 tests. This paper presents preliminary results from ZBOT's ground-based research delineating both pressurization and pressure reduction trends in the sealed test tank. Tank self-pressurization tests are conducted under three modes: VJ heating, strip heating and simultaneous VJ and strip heating in attempt to simulate heat leaks from the environment, the support structure and both. The jet mixing pressure control studies are performed either from an elevated uniform temperature condition or from thermally stratified conditions following a self-pressurization run. Jet flow rates are varied from 2-25 cm/s spanning a range of jet Re number in laminar, transitional, and turbulent regimes and a range of Weber numbers covering no ullage penetration, partial penetration and complete ullage penetration and break-up (only in microgravity). Numerical prediction of a two-phase CFD model are compared to experimental 1g results to both validate the model and also indicate the effect of the residual non-condensable gas on evolution of pressure and temperature distributions in the tank during pressurization and pressure control.

microgravity evaporation condensatio↗