Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Charges on a suspended silicon nitride membrane under a high-energy electron beam

Thin silicon nitride (SiN x ) membranes are widely used in gas and liquid phase transmission electron microscopy (TEM) and as phase plates to enhance imaging contrast. SiN x contains trap sites for both positive and negative charges, which can be manipulated by high-energy electron irradiation, external potential biasing, or light exposure. Charge accumulation on the membrane can significantly affect in situ TEM processes, including chemical and electrochemical reactions, nanoparticle dynamics, and catalytic activity, or introduce unwanted phase shifts when used as a phase plate. Here, in this study, charge accumulation on suspended SiN x membranes was investigated using off-axis electron holography combined with model-free charge analysis, supported by custom finite element analysis (FEA) simulations. An average residual positive charge density of approximately 2.8 × 10 −4 C m −2 was measured. Localized and stable regions of both positive and negative charges were identified on the membrane. The global positive and localized positive/negative charges give rise to strong electric fields and electroosmotic slip velocities at the membrane surface, which are sufficient to induce non-Brownian particle behavior and directional fluid flow, offering a physical explanation for previously observed anomalies in particle dynamics, nucleation, and growth during gas and liquid phase TEM experiments. These results provide a benchmark for understanding charge behavior at SiNx interfaces in gas and liquid phase TEM. Furthermore, the FEA simulations establish a framework for future investigations into charge distribution, electrostatic potentials, and electrical double layers at solid–liquid interfaces, particularly in complex geometries and chemically dynamic environments.

Suspended silicon↗

An Off-Axis Four-Quadrant Phase Mask (FQPM) Coronagraph for Palomar: High-Contrast Near Bright Stars Imager

Direct detection of planets around nearby stars requires the development of high-contrast imaging techniques because of the high difference between their respective fluxes. This led us to test a new coronagraphic approach based on the use of phase mask instead of dark occulting ones. Combined with high-level wavefront correction on an unobscured off-axis section of a large telescope, this method allows imaging very close to the star. Calculations indicate that for a given ground-based on-axis telescope, use of such an off-axis coronagraph provides a near-neighbor detection capability superior to that of a traditional coronagraph utilizing the full telescope aperture. Setting up a laboratory experiment working in near infrared allowed us to demonstrate the principle of the method, and a rejection of 2000:1 has already been achieved.

coronagraphy↗

Scalable method for micro-CT analysis enables large scale quantitative characterization of brain lesions and implants

Anatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.

3-D reconstruction↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

Freestanding high-aspect-ratio gold masks for low-energy, phase-based x-ray microscopy

High-resolution, x-ray phase contrast microscopy, a key technique with promising potential in biomedical imaging and diagnostics, is based on narrow-slit high-aspect-ratio gold gratings. Here we present the development, fabrication details, and experimental testing of the freestanding 10 μm thick gold membrane masks with an array of 0.9–1.5 μm void slit apertures for a novel low-energy x-ray microscope. The overall mask size is 4 mm × 4 mm, with a grating pitch of 7.5 μm, 6.0–6.6 μm wide gold bars are supported by 3 μm wide crosslinks at 400 μm intervals. The fabrication process is based on gold electroplating into a silicon mold coated with various thin films to form a voltage barrier, plating base, and sacrificial layer, followed by the mold removal to obtain the freestanding gold membrane with void slit apertures. We discuss key aspects for the materials and processes, including gold structures homogeneity, residual stresses, and prevention of collapsing of the grid elements. We further demonstrate the possibility to obtain high-resolution, high contrast 2D images of biological samples using an incoherent, rotating anode x-ray tube.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Modeling the Interaction of Laser-Produced Proton Beams with Matter

A major goal of this project is to significantly increase our understanding of isochoric heating of matter using laser produced proton beams, and the associated high energy density (HED) and warm dense matter (WDM) regimes generated. This will benefit research fields such as planetary science, fusion energy, plasma physics, and material science. For example, it will enhance our understanding of WDM properties of iron and silica under conditions encountered in planetary interiors and diagnostic components in fusion devices exposed to high fluxes of energetic plasma ions. The project is motivated by recent experiments that irradiated Si targets with proton beams generated by the 20 TW-laser at the SLAC MEC end-station. The HED/WDM states are probed using the 50 fs hard X-rays available in the 3rd harmonic of the LCLS. As part of this project, results from the phase contrast X-ray imaging, which shows the generation of compression waves that produces rear surface spallation, are compared with results from the 3D multi-physics multi- material code, PISALE, that combines Arbitrary Lagrangian-Eulerian (ALE) hydrodynamics with Adaptive Mesh Refinement (AMR). This comparison required modifications to several physics models in the PISALE (Pacific Island Structured-AMR with ALE) code. An important aspect of this project is the continued training of graduate students in HED physics and in conducting complex multiphysics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Microscopic Characterization of Protein Crystals

The microscopic mapping of the variation in degree of perfection and in type of defects in entire protein crystals by x-rays may well be a prerequisite for better understanding causes of lattice imperfections, the growth history, and properties of protein crystals. However, x-ray microscopic characterization of bulk protein crystals, in the as-grown state, is frequently more challenging than that of small molecular crystals due to the experimental difficulties arising largely from the unique features possessed by protein crystals. In this presentation, we will illustrate ssme recent activities in employing coherence-based phase contrast x-ray imaging and high-angular-resolution diffraction techniques for mapping microdefects and the degree of perfection of protein crystals, and demonstrate a correlation between crystal perfection, diffraction phenomena., and crystallization conditions. The observed features and phenomena will be discussed in context to gain insight into the nature of defects, nucleation and growth, and the properties of protein crystals.

Hu, Z. W.↗

A Uniform Analysis of Debris Discs with the Gemini Planet Imager II: Constraints on Dust Density Distribution Using Empirically Informed Scattering Phase Functions

Spatially resolved images of debris discs are necessary to determine disc morphological properties and the scattering phase function (SPF) thatantifies the brightness of scattered light as a function of phase angle. Current high-contrast imaging instruments have successfully resolved several dozens of debris discs around other stars, but few studies have investigated trends in the scattered-light, resolved population of debris discs in a uniform and consistent manner. We have combined Karhunen-Loeve Image Projection (KLIP) with radiative-transfer disc forward modelling in order to obtain the highest-quality image reductions and constrain disc morphological properties of eight debris discs imaged by the Gemini Planet Imager at H -band with a consistent and uniformly applied approach. In describing the scattering properties of our models, we assume a common SPF informed from solar system dust scattering measurements and apply it to all systems. We identify a diverse range of dust density properties among the sample, including critical radius, radial width, and vertical width. We also identify radially narrow and vertically extended discs that may have resulted from substellar companion perturbations, along with a tentative positive trend in disc eccentricity with relative disc width. We also find that using a common SPF can achieve reasonable model fits for discs that are axisymmetric and asymmetric when fitting models to each side of the disc independently, suggesting that scattering behaviour from debris discs may be similar to Solar system dust.

scattering↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

Understanding the Influence of Receptive Field and Network Complexity in Neural Network-Guided TEM Image Analysis

Abstract Trained neural networks are promising tools to analyze the ever-increasing amount of scientific image data, but it is unclear how to best customize these networks for the unique features in transmission electron micrographs. Here, we systematically examine how neural network architecture choices affect how neural networks segment, or pixel-wise separate, crystalline nanoparticles from amorphous background in transmission electron microscopy (TEM) images. We focus on decoupling the influence of receptive field, or the area of the input image that contributes to the output decision, from network complexity, which dictates the number of trainable parameters. For low-resolution TEM images which rely on amplitude contrast to distinguish nanoparticles from background, we find that the receptive field does not significantly influence segmentation performance. On the other hand, for high-resolution TEM images which rely on both amplitude and phase-contrast changes to identify nanoparticles, receptive field is an important parameter for increased performance, especially in images with minimal amplitude contrast. Rather than depending on atom or nanoparticle size, the ideal receptive field seems to be inversely correlated to the degree of nanoparticle contrast in the image. Our results provide insight and guidance as to how to adapt neural networks for applications with TEM datasets.

42 ENGINEERING↗

Differential phase acoustic microscope for micro-NDE

A differential phase scanning acoustic microscope (DP-SAM) was developed, fabricated, and tested in this project. This includes the acoustic lens and transducers, driving and receiving electronics, scanning stage, scanning software, and display software. This DP-SAM can produce mechanically raster-scanned acoustic microscopic images of differential phase, differential amplitude, or amplitude of the time gated returned echoes of the samples. The differential phase and differential amplitude images provide better image contrast over the conventional amplitude images. A specially designed miniature dual beam lens was used to form two foci to obtain the differential phase and amplitude information of the echoes. High image resolution (1 micron) was achieved by applying high frequency (around 1 GHz) acoustic signals to the samples and placing two foci close to each other (1 micron). Tone burst was used in this system to obtain a good estimation of the phase differences between echoes from the two adjacent foci. The system can also be used to extract the V(z) acoustic signature. Since two acoustic beams and four receiving modes are available, there are 12 possible combinations to produce an image or a V(z) scan. This provides a unique feature of this system that none of the existing acoustic microscopic systems can provide for the micro-nondestructive evaluation applications. The entire system, including the lens, electronics, and scanning control software, has made a competitive industrial product for nondestructive material inspection and evaluation and has attracted interest from existing acoustic microscope manufacturers.

Waters, David D.↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Rapid in situ hybridization technique using 16S rRNA segments for detecting and differentiating the closely related gram-positive organisms Bacillus polymyxa and Bacillus macerans

A rapid, sensitive, inexpensive in situ hybridization technique, using 30-mer 16S rRNA probes, can specifically differentiate two closely related Bacillus spp., B. polymyxa and B. macerans. The 16S rRNA probes were labeled with a rhodamine derivative (Texas Red), and quantitative fluorescence measurements were made on individual bacterial cells. The microscopic fields analyzed were selected by phase-contrast microscopy, and the fluorescence imaging analyses were performed on 16 to 67 individual cells. The labeled 16S rRNA probe, POL, whose sequence was a 100% match with B. polymyxa 16S rRNA but only a 60% match with B. macerans 16S rRNA, gave quantitative fluorescence ratio measurements that were 34.8-fold higher for B. polymyxa cells than for B. macerans cells. Conversely, the labeled probe, MAC, which matched B. polymyxa 16S rRNA in 86.6% of its positions and B. macerans 16S rRNA in 100% of its positions, gave quantitative fluorescence measurements that were 59.3-fold higher in B. macerans cells than in B. polymyxa cells. Control probes, whose 16S rRNA sequence segment (P-M) was present in both B. polymyxa and B. macerans as well as a panprokaryotic probe (16S), having a 100% match with all known bacteria, hybridized equally well with both organisms. These latter hybridizations generated very high fluorescence signals, but their comparative fluorescence ratios (the differences between two organisms) were low. The control paneukaryotic probe (28S), which had less than 30% identity for both B. macerans and B. polymyxa, did not hybridize with either organism.

Non-NASA Center↗

The application of cinematic rendering to CT evaluation of upper tract urothelial tumors: principles and practice

Upper tract urothelial carcinoma (UTUC) is a relatively uncommon but aggressive genitourinary malignancy for which multi-phase contrast-enhanced computed tomography (CT) plays an important role in evaluation and staging. 3D imaging with maximum intensity projection (MIP) and volume-rendered (VR) images has been described as a useful means of evaluating UTUC. In this study, we describe the technique of a novel 3D methodology known as cinematic rendering (CR) and provide clinical examples of UTUC visualized with CR. CR utilizes a complex universal lighting model in order to create photorealistic images with improved detail and depth in comparison to MIP or VR images. In the case of UTUC, CR can be used in different contrast phases to show abnormally thickened and enhancing urothelium or filling defects in the renal collecting system or ureters in the excretory phase. CR images can also be manipulated in order to generate translucent views of the upper urinary tract in order to add conspicuity to intraluminal findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Noninvasive 3D Visualization of Defects and Crack Propagation in Layered Foam Structures by Phase Contrast Microimaging

Applications of polymeric foams in our modern society continue to grow because of their light weight, high strength, excellent thermal and mechanical insulation, and the ease of engineering. Among others, closed-cell foam has been structurally used for thermally insulating the shuttle external tank. However, internal defects of the foams were difficult to observe non-invasively due to limited sensitivity to the low-density structures possessed by traditional imaging tools such as computed X-ray tomography By combining phase contrast X-ray imaging with pressure loading, we succeeded in precisely mapping intact cellular structure and defects inside the bulk of layered foam and visualizing its subsequent response to the pressure in three-dimensional space. The work demonstrated a powerfir1 approach for yielding insight into underlying problems in lightweight cellular materials otherwise unobtainable.

Hu, Z. W.↗

Information transfer as a framework for optimized phase imaging

In order to efficiently image a non-absorbing sample (a phase object), dedicated phase contrast optics are required. Typically, these optics are designed with the assumption that the sample is weakly scattering, implying a linear relation between a sample’s phase and its transmission function. In the strongly scattering, nonlinear case, the standard optics are ineffective, and the transfer functions used to characterize them are uninformative. We use the Fisher information (FI) to assess the efficiency of various phase imaging schemes and to calculate an information transfer function (ITF). We show that a generalized version of Zernike phase contrast is efficient given sufficient prior knowledge of the sample. We show that with no prior knowledge, a random sensing measurement yields a significant fraction of the available information. Finally, we introduce a generalized approach to common path interferometry that can be optimized to prioritize sensitivity to particular sample features. Each of these measurements can be performed using Fourier lenses and phase masks.

Koppell, Stewart↗