Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Improved liquid lithium surfaces in the Lithium Tokamak Experiment-β

Advances in vacuum, surface, and lithium conditioning techniques throughout five years of continuous operations in LTX-β have produced mirror-like liquid lithium surfaces and demonstrated the feasibility of high-performance tokamak discharges fully surrounded by liquid metal without significant operational problems. Improvements in conditioning techniques and procedures, including many weeks of baking and accumulation of 70 g of Li, led to reduced residual gasses and clean Li surfaces - all while still maintaining enough operational flexibility for multiple in-vacuum diagnostic upgrades and calibrations. Coatings had a visibly clean appearance, with reflective liquid metal demonstrating good wetting and surface adhesion with films that were now macroscopically thick. Solidified Li showed large crystal grains, while surface science measurements observed reduced impurities in the lithium. Steadily improved plasma performance was achieved with liquid lithium, with discharges able to match solid Li in terms of evolution of I p and n e , including rapid density pumping indicating low recycling. There were indications of moderately increased Li impurity influx, though few significant disturbances by the large liquid surfaces on tokamak operations over hundreds of discharges. Liquid metal plasma facing components are a potential solution to the extreme heat and particle fluxes that could cause unacceptable damage to solid materials, while liquid lithium also has the potential for greatly increased confinement in the low-recycling regime. While many liquid metal approaches are possible, and numerous experiments have been conducted in test stands and small modules in fusion devices, LTX-β is the only tokamak operated while fully surrounded by liquid metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The use of a digital micromirror array as a temporal gate and spatial-filtering device for laser-induced breakdown spectroscopy and laser ablation molecular isotopic spectrometry

A digital micromirror array (DMMA) is used in a simple and inexpensive approach for spatially resolved temporal gating of atomic emission detection in laser-induced breakdown spectroscopy (LIBS). Selected mirrors in the array are actuated at a time delayed from the primary laser pulse, permitting optical gating with a response time of 160 ns while using a conventional CCD detector. Detector gating is shown to decrease noise from short-lived spectroscopic background (both continuum and N II from air), improving signal-to-background ratios by 22-times for selected samples and emission lines. The utility of rapid temporal gating is also demonstrated for the optical detection of isotopes using the laser-ablation molecular isotope spectrometry (LAMIS) experiment. Additionally, optical temporal gating and spatial filtering are used to isolate regions of the laser-induced plasma, enhancing signal from molecular emission. The potential of the simple technique for use in field-portable LIBS and LAMIS experiments is explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Bi-Kappa Proton Mirror and Cyclotron Instabilities in the Solar Wind

Abstract The charged particles in the solar wind are often observed to possess a nonthermal tail in the velocity distribution function, a feature that can be fitted with the Kappa model. The anisotropic, or bi-Kappa, model of protons, electrons, and other charged particles is thus adopted in the literature for interpreting the data as well as in the context of the analysis of wave–particle interactions. The present paper develops an approximate but efficient theory of the mirror and cyclotron instabilities excited by the bi-Kappa protons in the solar wind. A velocity moment-based quasi-linear theory of these instabilities is also formulated in order to investigate the saturation behavior. Applications of the formalism are made for instabilities close to the marginally unstable state, which is typical of the solar wind near 1 au.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron Bernstein wave conversion of high-field side injected X-modes in QUEST

This paper presents a detailed design of the Q-shu University experimental steady state spherical tokamak's (QUEST's) high-field side (HFS) injection system for electron Bernstein wave (EBW) excitation and the results of an experimental comparison of the HFS eXtraordinary X-mode and low-field side (LFS) ordinary O-mode injection of 8.2 GHz radio frequency (RF) power. Waveguides, as an alternative to mirror polarizers for transmitting RF X-mode power from LFS to HFS for EBW conversion, were used instead of the installation of an RF mirror. Testing of LFS-to-HFS RF power transmission at 8.2 GHz, using an RG-50-type vacuum waveguide in a bench-scale device filled with SF6 gas at 0.03 Mpa, revealed that an RF power of 10.8 kW could traverse the fundamental electron cyclotron resonance layer for 60 s without breakdown. The short-length, open-ended waveguide antenna used in the HFS injection-induced wave diffraction reduced the efficiency of power delivery to the upper hybrid resonance (UHR) by approximately 7% at an electron temperature of 50 eV. The HFS injection was able to produce brighter camera images than the standard LFS injection. The location of the UHR, as estimated by measuring the density with an interferometer, agreed with its location as measured by plasma radiation low-field, side-edge positions shown by fast camera imaging. This indicates that the plasma was produced by mode-converted EBW. The HFS injection had an absorption efficiency of 96%, compared to 40% for LFS. A greater fluctuation of floating potential adjustable to the lower hybrid wave (LHW) was observed in the HFS case by installing a Langmuir probe, confirming that EBW conversion efficiency was higher in the HFS case. Moreover, after setting the poloidal field to B PF = 7.6 mT, plasma current (I P ) in the HFS peaked at 1.3 kA, as opposed to 0.3 kA for LFS, despite LFS injection having a total power of 55 kW, compared to 40 kW for HFS. However, as the impurity level was comparatively high, it is believed that this I P is dominated by pressure-drive, which makes it difficult to analyze EBWCD. Finally, the line-integrated density in the HFS injection peaked at 1.6 × 10 18 m -2 , compared to 8 × 10 17 m -2 in the LFS one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and preliminary results of 270 GHz microwave forward scattering diagnostic system on the experimental advanced superconducting tokamak (EAST)

To measure localized (intermediate, high) poloidal wavenumber electron density fluctuations, a tangential millimeter-wave collective scattering system has been designed and successfully developed on the experimental advanced superconducting tokamak (EAST). This innovative system employs a 270 GHz mm-wave probe beam, emitted from the mid-plane of Port K and directed towards Port P after passing through a combination of two in-vessel mirrors. Here these two ports are located on the EAST device’s midplane and are 110° apart. The downward scattered signals pass through two in-vessel mirrors, and exit through the P window. The received multi-channel separated scattering signals are arranged along the poloidal direction. This optical arrangement makes the monitored turbulent wave number is poloidal dominant and up to 40 cm −1 . The tangential microwave scattering scheme enables this diagnostic to monitor local density fluctuations, with typically a radial spatial resolution △ R = 5 cm, and a wavenumber resolution of △ k = 0.4 cm −1 . The scattering system underwent comprehensive laboratory testing in 2023, with installation finalized in 2024. The system features steerable launch and receiver optics, allowing remote control to position the scattering volume from normalized radius ρ –0 to the pedestal region on a shot-by-shot basis. Effective experimental data, characterized by distinct off-center spectral peaks, have been successfully obtained in neutral beam-heated plasmas on EAST. The beam tracing forward modeling has been employed for experimental data interpretation. The advanced millimeter-wave scattering system provides fluctuation measurement capability from ion temperature gradient to electron temperature gradient scale on low field side. Preliminary experimental density fluctuation data have been successfully obtained in neutral beam-heated plasmas on EAST. The localized measurement will be used for kinetic turbulence transport numerical simulation validation.

high-k collective scattering↗

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗

Isodrastic magnetic fields for suppressing transitions in guiding-centre motion

In a magnetic field, transitions between classes of guiding-centre motion can lead to cross-field diffusion and escape. We say a magnetic field is isodrastic if guiding centres make no transitions between classes of motion. This is an important ideal for enhancing confinement. First, we present a weak formulation, based on the longitudinal adiabatic invariant, generalising omnigenity. To demonstrate that isodrasticity is strictly more general than omnigenity, we construct weakly isodrastic mirror fields that are not omnigenous. Then we present a strong formulation that is exact for guiding-centre motion. We develop a first-order treatment of the strong version via a Melnikov function and show that it recovers the weak version. The theory provides quantification of deviations from isodrasticity that can be used as objective functions in optimal design. The theory is illustrated with some simple examples.

97 MATHEMATICS AND COMPUTING↗

Computational analysis of ion orbital loss in diverted positive- and negative-triangularity tokamaks

The mechanism of ion orbital loss in diverted negative-triangularity (NT) tokamaks is significantly different from that of positive-triangularity (PT) tokamaks. The orbital loss from the edge of NT tokamaks can be quite large, because the separatrix X-point is located on the outboard side, meaning that trapped ions crossing the separatrix are lost to the inboard divertor plate after a mirror reflection on the side of the strong magnetic field. NT tokamaks have difficulties in building up steep pressure gradients in the edge regions. However, the majority of trapped ions crossing the separatrix in PT tokamaks survive (through complete banana motions) without reaching the X-point region. For NT tokamaks, topological changes in the trapped ion trajectories can be achieved in the presence of the radial electric field, thus reducing the orbital loss, whereas for PT tokamaks, the orbital loss is relatively insensitive to the radial electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Thomson scattering of a tightly focused relativistically intense laser pulse by an ensemble of particles

We report a study of the process of nonlinear Thomson scattering (NTS) of a tightly focused relativistically intense laser pulse by an ensemble of electrons simulating the result of ionisation of an ultrathin nanofoil. The description of all six components of a laser pulse is based on the Stratton – Chu integrals describing radiation focused by an off-axis parabolic mirror into a spot down to the diffraction limit, which is of practical interest for modern experiments with extreme-intensity lasers, including diagnostics of their parameters. The interaction of a laser pulse with electrons is simulated by the test-particle method, and the resulting trajectories are used to calculate the characteristics of secondary electromagnetic radiation. The effect of the laser-pulse focal spot diameter in the range λ – 6λ on the angular distributions of the radiated energy and NTS spectra, as well as of a laser-beam peak intensity of 10{sup 21} – 10{sup 22} W cm{sup −2} on the spectral width of the secondary radiation is studied in relation to the experimentally implemented focusing scheme using the example of a laser pulse with an initial homogeneous spatial distribution and a duration of ∼25 fs. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-bandwidth image-based predictive laser stabilization via optimized Fourier filters

Controlling the delivery of kHz-class pulsed lasers is of interest in a variety of industrial and scientific applications, from next-generation laser-plasma acceleration to laser-based x-ray emission and high-precision manufacturing. The transverse position of the laser pulse train on the application target is often subject to fluctuations by external drivers (e.g., room cooling and heating systems, motorized optics stages and mounts, vacuum systems, chillers, and/or ground vibrations). For typical situations where the disturbance spectrum exhibits discrete peaks on top of a broad-bandwidth lower-frequency background, traditional PID (proportional-integral-derivative) controllers may struggle, since as a general rule PID controllers can be used to suppress vibrations up to only about 5%–10% of the sampling frequency. Here, a predictive feed-forward algorithm is presented that significantly enhances the stabilization bandwidth in such laser systems (up to the Nyquist limit at half the sampling frequency) by online identification and filtering of one or a few discrete frequencies using optimized Fourier filters. Furthermore, the system architecture demonstrated here uses off-the-shelf CMOS cameras and piezo-electric actuated mirrors connected to a standard PC to process the alignment images and implement the algorithm. To avoid high-end, high-cost components, a machine-learning-based model of the piezo mirror’s dynamics was integrated into the system, which enables high-precision positioning by compensating for hysteresis and other hardware-induced effects. A successful demonstration of the method was performed on a 1 kHz laser pulse train, where externally-induced vibrations of up to 400 Hz were attenuated by a factor of five, far exceeding what could be done with a standard PID scheme.

Natal, Joseph↗

Line Emission Mapper: an X-ray probe mission concept to study the cosmic ecosystems and the physics of galaxy formation

In the 2020 Astrophysics Decadal Survey, the National Academies identified cosmic feedback and structure formation as a key question that should drive research in the upcoming decade. In response to this recommendation, NASA released a call for X-ray and IR probe-class missions, with a $\$$1B cost cap. The line emission mapper (LEM) is a mission concept designed in response to this call. LEM is a single-instrument X-ray telescope that consists of a Wolter–Schwarzschild type I X-ray optic with a 4 m focal length, coupled with an X-ray microcalorimeter with a 30' field of view (FoV), 15" angular resolution, and 2.5 eV energy resolution [full-width half maximum (FWHM)], with a 1.3 eV FWHM energy resolution central subarray. The high throughput X-ray mirror combined with the large FoV and excellent energy resolution allows for efficient mapping of extended emission-line dominated astrophysical objects from megaparsecs to sub-pc scales to study cosmic ecosystems and unveil the physical drivers of galaxy formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement

The high density fluctuation poloidal wavenumber, k θ (k θ > 8 cm –1 , k θ ρ s > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher k θ (>8 cm –1 ) is substantially reduced, making it difficult to measure higher k θ turbulence. The new DBS system has been optimized to access higher wavenumber, k θ ≤ 20 cm –1 , density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5–1.0. As a result, the new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of a gallium alloy liquid metal mirror for application in inertial fusion energy systems

The final optic in future inertial fusion energy plants must maintain high performance and survivability under gigashot laser irradiation while exposed to fusion byproducts. Although no practical solution has been demonstrated, a self-healing final turning mirror based on a grazing-incidence liquid metal mirror has been theoretically explored. This work investigates the suitability of a gallium alloy. The experimental system simulates key conditions, including vacuum exposure and 10-Hz, 355-nm, and 6-ns laser pulses. Experiments address reflectivity, damage, and response as a function of pressure. Results highlight the potential of liquid metal gallium alloys for robust final optics in laser-based fusion power plants and inform non-traditional optics for intense laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenically enhanced quasi-optical resonator for megawatt pulsed millimeter-wave sources

We report the design, cryogenic optimization, and performance modeling of a compact quasi-optical ring resonator intended to compress microwaves pulses at 170 and 250 GHz to the megawatt level. By combining ultra-low-loss CVD diamond and gold-doped silicon wafers with high-RRR copper mirrors, the calculated unloaded quality factor exceeds 4.3 × 10 5 at 20 K and yields simulated gains up to $\mathscr{G}$ = 4.1 × 10 3 . Coupling the resonator with a laser-driven semiconductor switch described by an extended Vogel model shows that 1 MW, nanosecond pulses can be generated from only 445 W of microwave drive power while dissipating 272 W into the cryostat. A practical cooling architecture using two Gifford–McMahon stages (20 and 80 K) is proposed, demonstrating that high-repetition-rate (10–20 kHz) operation is feasible with commercially available cryocoolers. The results outline a clear path toward cost-effective, table-top sources for extreme-ultraviolet lithography, dynamic nuclear polarization, and fusion systems.

Panisset, Constant [Ecole Polytechnique Federale L↗

Particle-based modelling of axisymmetric tandem mirror devices

In this work, we describe the use of a 1D-2V quasi-neutral hybrid electrostatic PIC with Monte-Carlo Coulomb collisions and non-uniform magnetic field to model the parallel transport and confinement in an axisymmetric tandem mirror device. End-plugs, based on simple-mirrors, are positioned at each end of the device and fueled with neutral beams (25 and 100 keV) to produce a sloshing ion population and increase the density of the end-plugs relative to the central cell. Results show the formation of a potential difference barrier between the central cell and the end-plugs. This potential confines a large fraction of the low energy thermal ions in the central cell which would otherwise be lost in a simple mirror, demonstrating the advantage of the beam-driven tandem mirror configuration relative to simple mirrors. In addition, we explore the effect of end-plug electron temperature on the confinement time of the device and compare it with theoretical estimates. Finally, we discuss the limitations of the code in its present form and describe the next logical steps to improve its predictive capability such as a fully nonlinear Fokker–Planck collision operator, multiply nested flux surface solutions and modeling the exhaust region up to the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗