Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Machine learning from RANS and LES to inform coarse grid simulations

Nuclear system thermal hydraulic analysis has historically relied on computationally inexpensive 1D codes. However, such tools are unable to capture multiscale multidimensional effects in large nuclear reactor enclosures. On the other hand, simulations with higher fidelity can be too expensive for such purposes. One of the ways to reduce computational cost is to perform simulations on a coarse grid, which, unfortunately, introduces large discretization errors. In this paper, two high-to-low data-driven approaches are investigated: (1) a coarse grid turbulence model to predict eddy viscosity and (2) correction of errors in coarse grid velocity fields. The approaches aim to reduce grid- and turbulence model-induced errors in coarse grid Reynolds-averaged Navier–Stokes (RANS) simulations. Two sources of high-fidelity data, RANS and large eddy simulations (LES), are explored. To extract the eddy viscosity from the LES data, an inverse optimization problem is solved. However, the LES eddy viscosity is shown to be comparable to the RANS eddy viscosity in terms of error reduction. Therefore, the directly available RANS eddy viscosity was used to develop a coarse grid data-driven turbulence model. Additionally, error correction in velocity is used to reduce the remaining uncertainties and bring the results closer to reality. In conclusion, the performance of the frameworks is demonstrated for a scaled upper plenum of a gas-cooled reactor facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary Report of the FY24 DOE Contributions to the GIF VHTR CMVB

The Generation-IV Forum (GIF) Very-High-Temperature Reactor-Computational Methods Validation and Benchmark (VHTR-CMVB) initiative, involving organizations from Korea Atomic Energy Research Institute (KAERI) (South Korea), Institute of Nuclear and New Energy Technology of Tsinghua University (INET) (China), U.S. Department of Energy (DOE) (U.S.), Joint Research Centre (JRC) (Europe), and Japan Atomic Energy Agency (JAEA) (Japan), is dedicated to the verification and validation of tools for High-Temperature Gas-Cooled Reactors (HTGRs) analysis, using data shared by Computational Methods Validation and Benchmark (CMVB) signatories. For FY24, the US DOE CMVB has committed to several critical activities. Under WP1, led by the US, the integration of the High Temperature Gas Cooled Reactor - Pebble-Bed Module (HTR-PM) Phenomena Identification and Ranking Table (PIRT) into the comparative PIRT is progressing, with a new draft of the comparison tables issued earlier this year and currently being utilized by INET for their contribution. Neutronic validation efforts under WP3 include the preparation of the burnup analysis benchmark, preliminary calculations, and the development of reference models and results. In WP2, a validation exercise for hot gas mixing in the lower plenum of HTR-PM is in progress, using experimental data from INET (China) to validate modeling approaches. A model of the experimental facility has been developed using StarCCM+, with initial calculations slated for presentation at the GIF CMVB meeting this fall. Another WP2 activity focuses on validating numerical models for air-cooled Reactor Cavity Cooling System (RCCS) with experimental data from the Wisconsin Madison RCCS facility. A high-fidelity model, developed using NEK-RS, is currently being validated with available data from a low power forced convection test. These efforts are aimed at enhancing and confirming the accuracy of HTGR analysis tools, ensuring their alignment with experimental data and regulatory requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mass flow rate effect on a rotating detonation combustor with an axial air injection

Changing the flow rate of reactants being injected into a rotating detonation combustor (RDC) results in interesting behavior of the system. Prior studies have found that an increase in mass flow rate gradually increases the detonation wave speed before splitting the wave into multiple fronts. Here, the focus of this study is in understanding the physics of such behavior through a combination of experiments and numerical simulations. For this purpose, the axial air inlet-based RDC geometry is used. In the experiments, the wave velocity increased similar to prior studies. Corresponding full-scale simulations show that increase in mass flow rate by increasing pressure of the feed plenums shortens the recovery time of the injectors. This causes a more uniform fuel–air mixture to form prior to the arrival of the detonation wave. As a result, a more ideal detonation is observed, which leads to an increased wave velocity. Details of the detonation structure and variation with mass flow rate are analyzed. The presence and variation of the different deflagration zones in such non-premixed RDCs are also discussed.

42 ENGINEERING↗

Multiphysics Simulation of Moisture-Graphite Oxidation in MHTGR

A small amount of moisture on the ppm level could present in the primary helium coolant under normal operations of High-Temperature Gas-cooled Reactors (HTGRs). One potential safety issue related to HTGRs is the chronic moisture-graphite oxidation, which could affect the integrity of the fuel blocks and reflectors in the reactor core, and the support columns in the hot plenum. However, it is infeasible to perform chronic moisture-graphite oxidation tests under the prototypic high-pressure, high-temperature conditions over a long period of time that is comparable to the full service time, i.e., 36 months for Modular High Temperature Gas-cooled Reactor (MHTGR). As an alternate, accelerated moisture-graphite oxidation tests at the atmospheric pressure and high moisture concentrations have been performed in the literature. Through these accelerated tests, global reaction rate equations have been proposed, which makes it possible to study the moisture-graphite oxidation numerically. This paper is aimed to establish a multiphysics model that can evaluate the moisture-graphite oxidation under MHTGR normal operation conditions. COMSOL Multiphysics was applied to couple the fluid flow, heat and mass transfer, chemical reaction and material structural changes. To reduce the calculation time, the prototypic three-dimensional (3-D) structures were simplified into a two-dimensional (2-D) simulation domain. The performance of four nuclear grades of graphite (IG-110, 2114, PCEA, and NBG-17) over a 36-month service period was then investigated under the most likely prototypic conditions of MHTGR. The simulation results indicate that most oxidation occurs in the three or four bottom fuel blocks due to their higher temperatures. In general, however, only a thin layer of 1 mm into the graphite will be considerably oxidized even for those three or four bottom fuel blocks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative planar laser-induced fluorescence imaging of multi-component fuel/air mixing in a firing gasoline-direct-injection engine: Effects of residual exhaust gas on quantitative PLIF

A study of in-cylinder fuel-air mixing distributions in a firing gasoline-direct-injection engine is reported using planar laser-induced fluorescence (PLIF) imaging. A multi-component fuel synthesised from three pairs of components chosen to simulate light, medium and heavy fractions was seeded with one of three tracers, each chosen to co-evaporate with and thus follow one of the fractions, in order to account for differential volatility of such components in typical gasoline fuels. In order to make quantitative measurements of fuel-air ratio from PLIF images, initial calibration was by recording PLIF images of homogeneous fuel-air mixtures under similar conditions of in-cylinder temperature and pressure using a re-circulation loop and a motored engine. This calibration method was found to be affected by two significant factors. Firstly, calibration was affected by variation of signal collection efficiency arising from build-up of absorbing deposits on the windows during firing cycles, which are not present under motored conditions. Secondly, the effects of residual exhaust gas present in the firing engine were not accounted for using a calibration loop with a motored engine. In order to account for these factors a novel method of PLIF calibration is presented whereby 'bookend' calibration measurements for each tracer separately are performed under firing conditions, utilising injection into a large upstream heated plenum to promote the formation of homogeneous in-cylinder mixtures. These calibration datasets contain sufficient information to not only characterise the quantum efficiency of each tracer during a typical engine cycle, but also monitor imaging efficiency, and, importantly, account for the impact of exhaust gas residuals (EGR). By use of this method EGR is identified as a significant factor in quantitative PLIF for fuel mixing diagnostics in firing engines. The effects of cyclic variation in fuel concentration on burn rate are analysed for different fuel injection strategies. Finally, mixture distributions for late injection obtained using quantitative PLIF are compared to predictions of computational fluid dynamics calculations. (author)

33 ADVANCED PROPULSION SYSTEMS↗

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterisation of a small viscous flow turbine

The result of experimental and numerical study that was undertaken to determine the performance characteristics of viscous flow turbines is presented. It is anticipated that these devices may find use in applications such as small power sources for electronic appliances and micro-combined heat and power applications. In the numerical work that was carried out to broaden the experimental results, commercial CFD solver Fluent 6.2 was used while accompanying software, Gambit 3.2, was used for performing the necessary pre-processing. The results of the experimental study indicate that the adiabatic efficiency of these machines is around 25%. The main reasons for the low efficiency have been identified to be, parasitic losses in the bearing, viscous losses in the end walls, and other dissipative losses in the plenum chamber that also significantly contribute to the low efficiencies of these devices. If these parasitic losses can be minimised the turbine could potentially operate with an adiabatic expansion efficiency close to the theoretical limit of around 40%. (author)

42 ENGINEERING↗

The simplicity of fractal-like flow networks for effective heat and mass transport

A variety of applications using disk-shaped fractal-like flow networks and the status of one and two-dimensional predictive models for these applications are summarized. Applications discussed include single-phase and two-phase heat sinks and heat exchangers, two-phase flow separators, desorbers, and passive micromixers. Advantages of using these fractal-like flow networks versus parallel-flow networks include lower pressure drop, lower maximum wall temperature, inlet plenum symmetry, alternate flow paths, and pressure recovery at the bifurcation. The compact nature of microscale fractal-like branching heat exchangers makes them ideal for modularity. Differences between fractal-like and constructal approaches applied to disk-shaped heat sink designs are highlighted, and the importance of including geometric constraints, including fabrication constraints, in flow network design optimization is discussed. Finally, a simple pencil and paper procedure for designing single-phase heat sinks with fractal-like flow networks based solely on geometric constraints is outlined. Benefit-to-cost ratios resulting from geometric-based designs are compared with those from flow networks determined using multivariable optimization. Results from the two network designs are within 11%. (author)

42 ENGINEERING↗

Experimental investigation on the flow instability behavior of a multi-channel boiling natural circulation loop at low-pressures

Natural circulation as a mode of heat removal is being considered as a prominent passive feature in the innovative nuclear reactor designs, particularly in boiling-water-reactors, due to its simplicity and economy. However, boiling natural circulation system poses many challenges to designer due to occurrence of various kinds of instabilities such as excursive instability, density wave oscillations, flow pattern transition instability, geysering and metastable states in parallel channels. This problem assumes greater significance particularly at low-pressures i.e. during startup, where there is great difference in the properties of two phases. In light of this, a parallel channel loop has been designed and installed that has a geometrical resemblance to the pressure-tube-type boiling-water-reactor, to investigate into the behavior of boiling natural circulation. The loop comprises of four identical parallel channels connected between two common plenums i.e. steam drum and header. The recirculation path is provided by a single downcomer connected between steam drum and header. Experiments have been conducted over a wide range of power and pressures (1-10 bar). Two distinct unstable zones are observed with respect to power i.e. corresponding to low power (Type-I) and high power (Type-II) with a stable zone at intermediate powers. The nature of oscillations in terms of their amplitude and frequency and their evolution for Type-I and Type-II instabilities are studied with respect to the effect of heater power and pressure. This paper discusses the evolution of unstable and stable behavior along with the nature of flow oscillation in the channels and the effect of pressure on it. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel evaporator architecture with entrance-length crossflow-paths for supercritical Organic Rankine Cycles

Here in this article, a novel geometry is proposed for evaporators that are used in Supercritical Organic Rankine Cycles. The proposed geometry consists of successive plenums at several length-scale levels, creating a multi-scale heat exchanger (HX). The channels at the lowest length-scale levels were considered to have their length determined by the thermal entrance-length. Numerical simulations based on turbulent flow correlations for supercritical R134a and water were used to evaluate the performance of heat exchangers. Using the data on pumping power and area of heat exchange, the total present cost was evaluated using a cost model for shell-and-tube heat exchangers. With respect to the shell-and-tube baseline case, the cost per heat load and total costs of new HXs is lowered by approximately 20–26% and 15–30%, respectively. This reduction in present costs of the new HXs were found to be attributed to higher operational costs for the shell-and-tube HXs, as evidenced by the higher pumping power, as well their capital investment costs. The cost savings in the new HX designs compared to those of the shell-and-tube HXs, at similar heat load performance, indicate that the new HX architectures proposed in this paper are valid alternatives to traditional HX designs.

42 ENGINEERING↗

Counter cross-flow evaporator geometries for supercritical organic Rankine cycles

With recent advancements in advanced manufacturing techniques, it is now possible to fabricate complex geometries that take advantage of well known principles of heat transfer. Therefore, unconventional configurations to enhance effectiveness beyond conventional designs can now be considered for practical application. Thermal performance and overall cost of a new design of heat exchangers in counter cross-flow configurations are studied using a simplified but accurate computational method. The new heat exchanger design was introduced and studied previously for a cross-flow configuration by Sabau et al. (2016, 2018). This new design concept uses multi-scale configurations with successive plenums for the working fluid. At the smallest scale the tubes are sized to be equal to the hydraulic entrance length of the inside fluid, in accord with constructal design. With this being said, results indicate that compared to the earlier cross-flow configuration, the counter cross-flow arrangement improves the thermal performance of the heat exchanger by as much as 17% and lowers the total cost by as much as 14%.

42 ENGINEERING↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

3-D CFD MODEL OF A MULTI-CELL HIGH TEMPERATURE ELECTROLYSIS STACK

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis stack performance and steam electrolysis in the Idaho National Laboratory (INL) Integrated Lab Scale (ILS) experiment. The model is made of 60 planar cells stacked on top of each other operated as Solid Oxide Electrolysis Cells (SOEC). Details of the model geometry are specific to a stack that was fabricated by Ceramatec, Inc. and tested at INL. Inlet and outlet plenum flow and distribution are considered. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, Nernst potential, operating potential, activation over-potential, anode-side gas composition, cathode-side gas composition, current density, and hydrogen production over a range of stack operating conditions. Variations in flow distribution and species concentration are discussed. End effects of flow and per-cell voltage are also considered.

08 HYDROGEN↗

Nuclear waste vitrification efficiency: cold cap reactions

The cost and schedule of nuclear waste treatment and immobilization are greatly affected by the rate of glass production. Various factors influence the performance of a waste-glass melter. One of the most significant, and also one of the least understood, is the process of batch melting. Studies are being conducted to gain fundamental understanding of the batch reactions, particularly those that influence the rate of melting, and models are being developed to link batch makeup and melter operation to the melting rate. Batch melting takes place within the cold cap, i.e., a batch layer floating on the surface of molten glass. The conversion of batch to glass consists of various chemical reactions, phase transitions, and diffusion-controlled processes. These include water evaporation (slurry feed contains as high as 60% water), gas evolution, the melting of salts, the formation of borate melt, reactions of borate melt with molten salts and with amorphous oxides (Fe2O3 and Al2O3), the formation of intermediate crystalline phases, the formation of a continuous glass-forming melt, the growth and collapse of primary foam, and the dissolution of residual solids. To this list we also need to add the formation of secondary foam that originates from molten glass but accumulates on the bottom of the cold cap. This study presents relevant data obtained for a high-level-waste melter feed and introduces a one-dimensional (1D) mathematical model of the cold cap as a step toward an advanced three-dimensional (3D) version for a complete model of the waste glass melter. The 1D model describes the batch-to-glass conversion within the cold cap as it progresses in a vertical direction. With constitutive equations and key parameters based on measured data, and simplified boundary conditions on the cold-cap interfaces with the glass melt and the plenum space of the melter, the model provides sensitivity analysis of the response of the cold cap to the batch makeup and melter conditions. The model demonstrates that batch foaming has a decisive influence on the rate of melting. Understanding the dynamics of the foam layer at the bottom of the cold cap and the heat transfer through it appears crucial for a reliable prediction of the rate of melting as a function of the melter-feed makeup and melter operation parameters. Although the study is focused on a batch for waste vitrification, the authors expect that the outcome will also be relevant for commercial glass melting.

Hrma, Pavel R↗

Model for the conversion of nuclear waste melter feed to glass

The rate of batch-to-glass conversion is a primary concern for the vitrification of nuclear waste, as it directly influences the life cycle of the cleanup process. This study describes the development of an advanced model of the cold cap, which augments the previous model by further developments on the structure and the dynamics of the foam layer. The foam layer on the bottom of the cold cap consists of the primary foam, cavities, and the secondary foam, and forms an interface through which the heat is transferred to the cold cap. Other model enhancements include the behavior of intermediate crystalline phases and the dissolution of quartz particles. The model relates the melting rate to feed properties and melter conditions, such as the molten glass temperature, foaminess of the feed, or the heat fraction supplied to the cold cap from the plenum space. The model correctly predicts a 25% increase in melting rate when changing the alumina source in the melter feed from Al(OH)3 to AlO(OH). It is expected that this model will be incorporated in the full glass melter model as its integral component.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of low smeared density sodium-cooled fast reactor metal fuel

An experiment was performed in the Experimental Breeder Rector-II (EBR-II) in the 1990s to show that metallic fast reactor fuel could be used in reactors with a single, once-through core. To prove the long duration, high burnup, high neutron exposure capability an experiment where the fuel pin was designed with a very large fission gas plenum and very low fuel smeared density (SD). The experiment, X496, operated to only 8.3 at. % burnup because the EBR-II reactor was scheduled for shut-down at that time. Many of the examinations of the fuel pins only funded recently with the resurgence of reactor designs using very high-burnup fuel. The results showed that, despite the low smeared density of 59% the fuel swelled radially to contact the cladding, fission gas release appeared to be slightly higher than demonstrated in conventional 75%SD fuel tests and axial growth was about the same as 75% SD fuel. There were axial positions in some of the fuel pins which showed evidence of fuel restructuring and an absence of fission products with low metaling points and gaseous precursors (Cs and Rb). Lastly, a model to investigate whether these areas may have overheated due to a loss of bond sodium indicates that it is a possible explanation for the fuel restructuring and something to be considered for fuel performance modeling of low SD fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗