Search NASA⌕ Search

SEARCH · Search NASA

Results for “Portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

ExaCA v2.0: A versatile, scalable, and performance portable cellular automata application for additive manufacturing solidification

The previously established ExaCA software for performance portable alloy grain structure simulation has been updated to better represent the solidification behavior during complex alloy processing conditions, such as those encountered during metal additive manufacturing (AM), and for improved performance and scalability. Here, an extension to the time–temperature history input data format and the core ExaCA algorithm to include an arbitrary number of melting and solidification events yielded improved prediction of texture for various melt pool geometries, expanding the range of AM-relevant conditions that can be accurately simulated. Improved heat transport process simulation coupling, including the creation of large raster datasets from single track time–temperature history data and in-memory coupling with the new, performance portable finite difference code Finch, were also demonstrated in example studies on the effect of multilayer AM microstructure predictions on hatch spacing and cell size, respectively. Additional new features are detailed and demonstrated, including the ability to perform simulations using various interfacial response function forms, execute simulations on state-of-the-art hardware, improved usability through post-processing versatility, and improved strong and weak scaling performance. The performance, physics, and versatility improvements demonstrated here will further enable large-scale studies on AM process–microstructure relationships that were not previously possible. Furthermore, the usability improvements and ability to run coupled AM process–microstructure simulations using the Finch-ExaCA workflow will facilitate broader use of this open-source software by the computational materials community.

36 MATERIALS SCIENCE↗

An immersed interface method for microstructure-scale electrochemical battery models: numerical formulation and performance portable implementation

We present the numerical formulation, verification, and performance portable implementation of an immersed interface method for microstructure scale electrochemical modeling of batteries. The innovation in this approach is the resolution of chemical species and electrostatic potential discontinuities at active interfaces without the use of interface conforming unstructured grids. A unified formulation on Cartesian grids for all domains (electrodes and electrolyte) is used with interfacial flux conditions applied using volume fraction or “color” function gradients. We have developed one dimensional and two dimensional test cases with analytic solutions for electrochemical modeling using which we verified the consistency and accuracy of our scheme. Our solver is also validated against solutions from a macroscale model and an unstructured multi-subdomain solver for a full lithium ion cell. We then demonstrated the utility of our solver on an image-based complex battery electrode microstructure at high charging rate. Our technique also exhibits good scalability on distributed memory architectures using central processing units (CPU), with problem sizes up to 1.8 billion degrees of freedom and with 5400 ranks. Initial performance studies of our open-source performance portable solver showed about 70 times speed up using a graphics processing unit (GPU) compared to single compute core for a problem with 4 million cells.

25 ENERGY STORAGE↗

Framework for the assessment of PEMS (Portable Emissions Measurement Systems) uncertainty

Highlights: • Portable Emissions Measurement Systems (PEMS) are used to measure Real-Driving Emissions (RDE) of vehicles. • The uncertainty of PEMS was evaluated based on experimental data and technical requirements prescribed in the European regulation. • The 2017 uncertainty estimation was 43%. European regulation 2016/427 (the first package of the so-called Real-Driving Emissions (RDE) regulation) introduced on-road testing with Portable Emissions Measurement Systems (PEMS) to complement the chassis dynamometer laboratory (Type I) test for the type approval of light-duty vehicles in the European Union since September 2017. The Not-To-Exceed (NTE) limit for a pollutant is the Type I test limit multiplied by a conformity factor that includes a margin for the additional measurement uncertainty of PEMS relative to standard laboratory equipment. The variability of measured results related to RDE trip design, vehicle operating conditions, and data evaluation remain outside of the uncertainty margin. The margins have to be reviewed annually (recital 10 of regulation 2016/646). This paper lays out the framework used for the first review of the NO{sub x} margin, which is also applicable to future margin reviews. Based on experimental data received from the stakeholders of the RDE technical working group in 2017, two NO{sub x} margin scenarios of 0.24–0.43 were calculated, accounting for different assumptions of possible zero drift behaviour of the PEMS during the tests. The reduced uncertainty margin compared to the one foreseen for 2020 (0.5) reflects the technical improvement of PEMS over the past few years.

54 ENVIRONMENTAL SCIENCES↗

Development of a CPU/GPU portable software library for Lagrangian–Eulerian simulations of liquid sprays

The Lagrangian–Eulerian method is widely used for simulations of fuel sprays in turbulent combustion because of the advantage of treating the spray droplets as discrete points. One challenge of the Lagrangian–Eulerian method is the intense computational requirement when tracking the large number of Lagrangian particles needed for high fidelity. We have developed a performance-portable library, Grit, to track the Lagrangian particles in parallel on central processing unit (CPU) and graphics processing unit (GPU) accelerated high performance computing (HPC) architectures. Grit is a C++ library which employs Message Passing Interface (MPI) for distributed memory parallelism and Kokkos programming model for on-node shared memory parallelism with performance portability across different architectures of GPUs and multi-core/manycore CPUs. The parallel algorithms, key parallel kernels, and their performances on the pre-exascale supercomputer, Summit, are presented. Grit is coupled with a direct numerical simulation (DNS) solver, S3D, for multiphase simulations. A conservative formulation has been developed and implemented in Grit for phase coupling with thermodynamic consistency. The formulation separates the conservation of mass, momentum and energy from the physical models to prevent accidental violation of conservation laws due to inconsistent models. The formulation also enforces consistent definitions of enthalpies of the fuel for both phases and the latent heat of evaporation. Finally, simulations of turbulent particle-laden flow and the evaporation of dilute turbulent spray jet are performed to verify the software implementation, and to demonstrate the scalability of Grit for large-scale multiphase simulations.

97 MATHEMATICS AND COMPUTING↗

Non-destructive measurement and real-time monitoring of apple hardness during ultrasonic contact drying via portable NIR spectroscopy and machine learning

Portable near-infrared spectrometer in the spectral range of 900–1700 nm was evaluated for the first time to assess and monitor apple hardness in real-time during ultrasonic drying. Calibration models were developed using PLS and ANN, and their performances were evaluated by internal leave-one-out cross-validation and an external dataset. Several pre-treatments including standard normal variate (SNV), multiplicative scatter correction (MSC), Savitzky–Golay first and second derivatives were employed to examine the effects of spectral variations in hardness prediction. Seven important wavelengths were selected using weighted regression coefficients to develop a simple MLR model to facilitate the model interpretation and circumvent noise. The models using PLS, MLR, and ANN with selected wavelengths predicted the apple hardness with R 2 p of 0.91, 0.91, 0.95, and RMSEP of 14.78, 14.85, and 12.46 N, respectively. Finally, the results indicate that portable NIR spectrometers are quite promising for real-time monitoring of apple hardness during ultrasonic drying.

47 OTHER INSTRUMENTATION↗

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

HARD: A performance portable radiation hydrodynamics code based on FleCSI framework

Hydrodynamics And Radiation Diffusion (HARD) is an open-source application for high-performance simulations of compressible hydrodynamics with radiation-diffusion coupling. Built on the FleCSI (Bergen et al., 2021 [1]) (Flexible Computational Science Infrastructure) framework, HARD expresses its computational units as tasks whose execution can be orchestrated by multiple back-end runtimes, including Legion (Bauer et al., 2012 [2]), MPI (Forum, 1994 [3]), and HPX (Kaiser et al., 2020 [4]). Node-level parallelism is handled through Kokkos (Edwards et al., 2014 [5]), providing a single-source, portable code base that runs efficiently on laptops, small homogeneous clusters, and the largest heterogeneous supercomputers currently available. To ensure scientific reliability, HARD includes a regression test suite that automatically reproduces canonical verification problems such as the Sod and LeBlanc shock tubes, and the Sedov blast wave, comparing numerical solutions against known analytical results. The project is distributed under an OSI-approved license, hosted on GitHub, and accompanied by reproducible build scripts and continuous integration workflows. This combination of performance portability, verification infrastructure, and community-focused development makes HARD a sustainable platform for advancing radiation hydrodynamics research across multiple domains.

97 MATHEMATICS AND COMPUTING↗

Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor based on Quantum Dots and a Lateral Flow Test Strip

A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescence intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

A high Q piezoelectric resonator as a portable VLF transmitter

Very low frequency communication systems (3 kHz–30 kHz) enable applications not feasible at higher frequencies. However, the highest radiation efficiency antennas require size at the scale of the wavelength (here, >1 km), making portable transmitters extremely challenging. Facilitating transmitters at the 10 cm scale, we demonstrate an ultra-low loss lithium niobate piezoelectric electric dipole driven at acoustic resonance that radiates with greater than 300x higher efficiency compared to the previous state of the art at a comparable electrical size. A piezoelectric radiating element eliminates the need for large impedance matching networks as it self-resonates at the acoustic wavelength. Temporal modulation of this resonance demonstrates a device bandwidth greater than 83x beyond the conventional Bode-Fano limit, thus increasing the transmitter bitrate while still minimizing losses. These results will open new applications for portable, electrically small antennas.

36 MATERIALS SCIENCE↗

A portable fiber optic sensor for the luminescent sensing of cobalt ions using carbon dots

Cobalt is critical to energy-relevant technologies, and demand for cobalt will increase significantly with growing global adoption of renewables. However, supply chain stability is threatened by economic and geopolitical factors, incentivizing domestic cobalt production from alternative resources such as coal, coal utilization byproducts (e.g., ash, acid mine drainage) and electronic waste. Rapid, inexpensive, and portable characterization techniques are needed to reduce production costs associated with cobalt prospecting and process monitoring. Here, in this research, we develop a compact, portable fiber optic luminescent probe for cobalt using phosphorus and nitrogen co-doped carbon dots as the sensing material. The carbon dot emission overlaps well with the cobalt absorption band at ~510 nm, leading to a selective decrease in emission as a function of cobalt concentration. The system responds nearly instantly to the presence of cobalt, with detection limits of 0.7 and 3.5 ppm in water and pH 1.68 buffer, respectively, providing comparable performance to a commercial spectrometer at a significantly lower cost. Moreover, the sensor is selective for cobalt in the presence of 13 of the most common metal ions encountered in coal utilization byproducts and is responsive to cobalt when spiked into an acid mine drainage leachate sample, highlighting the sensor's potential for real-world deployment in challenging matrices. In addition, integrating the carbon dots with a filter paper substrate produced ‘test strip’ sensors that exhibited a selective and sensitive visual response to cobalt using a handheld UV lamp. Taken together, the sensing system represents a significant step forward in the development of low-cost practical sensors for high-value metals in complex streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Performance Portability with the CMS Heterogeneous Pixel Reconstruction code

In the past years the landscape of tools for expressing parallel algorithms in a portable way across various compute accelerators has continued to evolve significantly. There are many technologies on the market that provide portability between CPU, GPUs from several vendors, and in some cases even FPGAs. These technologies include C++ libraries such as Alpaka and Kokkos, compiler directives such as OpenMP, the SYCL open specification that can be implemented as a library or in a compiler, and standard C++ where the compiler is solely responsible for the offloading. Given this developing landscape, users have to choose the technology that best fits their applications and constraints. For example, in the CMS experiment the experience so far in heterogeneous reconstruction algorithms suggests that the full application contains a large number of relatively short computational kernels and memory transfer operations. In this work we use a stand-alone version of the CMS heterogeneous pixel reconstruction code as a realistic use case of HEP reconstruction software that is capable of leveraging GPUs effectively. We summarize the experience of porting this code base from CUDA to Alpaka, Kokkos, SYCL, std::par, and OpenMP offloading. We compare the event processing throughput achieved by each version on NVIDIA and AMD GPUs as well as on a CPU, and compare those to what a native version of the code achieves on each platform.

Andriotis, Nikolaos↗

Experience with the alpaka performance portability library in the CMS software

ion Library for Parallel Kernel Acceleration) is a header-only C++ library that provides performance portability across different back-ends, abstracting the underlying levels of parallelism. It supports serial and parallel execution on CPUs, and extremely parallel execution on NVIDIA, AMD and Intel GPUs.This contribution will show how alpaka is used in the CMS software to develop and maintain a single code base; to use different toolchains to build the code for each supported back-end, and link them into a single application; to seamlessly select the best backend at runtime, and implement portable reconstruction algorithms that run efficiently on CPUs and GPUs from different vendors. It will describe the validation and deployment of the alpaka-based implementation in the CMS High Level Trigger, and highlight how it achieves near-native performance.

Alawieh, Jaafar [CERN]↗

Note: A portable pulsed neutron source based on the smallest sealed-type plasma focus device

Development and operation of a portable and compact pulsed neutron source based on sealed-type plasma focus (PF) device are reported. The unit is the smallest sealed-type neutron producing PF device. The effective volume of the PF unit is 33 cm{sup 3} only. A compact size single capacitor (4 {mu}F) is used as the energy driver. A battery based power supply unit is used for charging the capacitor and triggering the spark gap. The PF unit is operated at 10 kV (200 J) and at a deuterium gas filling pressure of 8 mb. The device is operated over a time span of 200 days and the neutron emissions have been observed for 200 shots without changing the gas in between the shots. The maximum yield of this device is 7.8 x 10{sup 4} neutrons/pulse. Beyond 200 shots the yield is below the threshold (1050 neutrons/pulse) of our {sup 3}He detector. The neutron energy is evaluated using time of flight technique and the value is (2.49 {+-} 0.27) MeV. The measured neutron pulse width is (24 {+-} 5) ns. Multishot and long duration operations envisage the potentiality of such portable device for repetitive mode of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable time-domain LED fluorimeter for nanosecond fluorescence lifetime measurements

Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve the peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 μM. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A portable high-resolution soft x-ray and extreme ultraviolet spectrometer designed for the Shanghai EBIT and the Shanghai low energy EBITs

A portable high resolution soft x-ray and extreme ultraviolet (EUV) spectrometer has been developed for spectroscopic research at the Shanghai Electron Beam Ion Trap (EBIT) laboratory. A unique way of aligning the grazing incidence spectrometer using the zero order of the grating is introduced. This method is realized by extending the range of the movement of the CCD detector to cover the zero order. The alignment can be done in a few minutes, thus leading to a portable spectrometer. The high vacuum needed to be compatible with the EBITs is reached by mounting most of the translation and rotation stages outside the chamber. Only one high vacuum compatible linear guide is mounted inside the chamber. This is to ensure the convenient interchange of the gratings needed to enable wavelength coverage of the whole range of 10 to 500 Å. Spectra recorded with one of our low energy EBITs shows that a resolving power of above 800 can be achieved. In the slitless configuration used in this work, we found the resolving power to be limited by the width of the EBIT plasma. When mounted on the Shanghai EBIT which is a high energy EBIT and has a narrower EBIT plasma width, the estimated resolving power will be around 1400 at 221.15 Å.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A portable Raman analyzer for microfluidic chips based on a dichroic beam splitter for integration of imaging and signal collection light paths

An integrated and portable Raman analyzer featuring an inverted probe fixed on a motor-driving adjustable optical module was designed for the combination of a microfluidic system. It possesses a micro-imaging function. The inverted configuration is advantageous to locate and focus microfluidic channels. Different from commercial micro-imaging Raman spectrometers using manual switchable light path, this analyzer adopts a dichroic beam splitter for both imaging and signal collection light paths, which avoids movable parts and improves the integration and stability of optics. Combined with surface-enhanced Raman scattering technique, this portable Raman micro-analyzer is promising as a powerful tool for microfluidic analytics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of fast neutron radiography system based on portable neutron generator

Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. The raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.

07 ISOTOPE AND RADIATION SOURCES↗

LibERI—A portable and performant multi-GPU accelerated library for electron repulsion integrals via OpenMP offloading and standard language parallelism

A portable and performant graphics processing unit (GPU)-accelerated library for electron repulsion integral (ERI) evaluation, named LibERI, has been developed and implemented via directive-based (e.g., OpenMP and OpenACC) and standard language parallelism (e.g., Fortran DO CONCURRENT). Offloaded ERIs consist of integrals over low and high contraction s, p, and d functions using the rotated-axis and Rys quadrature methods. GPU codes are factorized based on previous developments with two layers of integral screening and quartet presorting. In this work, the density screening is moved to the GPU to enhance the computational efficacy for large molecular systems. Here, the L-shells in the Pople basis set are also separated into pure S and P shells to increase the ERI homogeneity and reduce atomic operations and the memory footprint. LibERI is compatible with any quantum chemistry drivers supporting the MolSSI Driver Interface. Benchmark calculations of LibERI interfaced with the GAMESS software package were carried out on various GPU architectures and molecular systems. The results show that the LibERI performance is comparable to other state-of-the-art GPU-accelerated codes (e.g., TeraChem and GMSHPC) and, in some cases, outperforms conventionally developed ERI CUDA kernels (e.g., QUICK) while fully maintaining portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗