Search NASA⌕ Search

SEARCH · Search NASA

Results for “Post-combustion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

190 records · Page 11

Development of a rate-based ENRTL-RK process model for a water-lean solvent

Advanced water-lean solvents (WLS) for post-combustion CO2 capture offer several advantages over the aqueous amine solvents . WLS have lower parasitic energy penalty, lower corrosion, lower temperature and high-pressure CO2 regeneration leading to lower cost of CO2 capture. RTI International, with funding from the US Department of Energy, has been developing its novel water-lean solvent, that has shown specific reboiler duty of 2.3 GJ/t-CO2 at the 60-kWe pilot testing unit (Tiller Plant, SINTEF, Norway) and 2.6 GJ/t-CO2 at the engineering scale testing system (12 MWe) at the Technology Centre Mongstad (TCM) in Norway. All heat duties, including the one from TCM testing, were consistent with Aspen Plus modeling of the specific configuration of each test plant. This work focuses on the development of a detailed process model using in-house laboratory measurements and process data at pilot scale. The eNTRL-RK model used in this work is based on an unsymmetric activity coefficient model with the reference states chosen to be pure liquids for solvents and ideal dilute solution at unit solute molality (resulting in activity coefficient of unity at infinite dilution) for electrolytes. It uses the Redlich-Kwong equation of state for vapor phase properties and Henry’s law for solubility of supercritical gases. The model was validated using process data from the pilot-scale campaign at the Tiller plant, and the engineering scale test campaign at TCM. Data on CO2 capture rate, absorber, and regenerator temperature profiles and specific reboiler duties from two different test campaigns at Tiller and TCM, were used to further refine and validate the model and the model compares favorably to experimental data. The validation results against TCM campaign will be presented in this work.

CO2 capture↗

Insights from FEED studies for retrofitting existing fossil power plants with carbon capture technology

Recent United States Department of Energy (DOE) sponsored front-end engineering design (FEED) studies for retrofitting existing fossil-fueled power plants with state-of-the-art carbon capture technology contain previously overlooked real-world design considerations for near-term deployment of carbon capture. Insights from examining seven recently published FEED study reports are summarized in this paper. This includes a discussion of the design, performance, and cost implications associated with (1) location-specific considerations such as water availability, land availability, and accessibility; (2) host-plant-specific factors such as flue gas specifications, allowable degree of integration between the capture system and host plant, and operational mode; and (3) miscellaneous factors such as market conditions, permitting requirements, and business case incentives. In conclusion, this manuscript highlights (1) water availability as a key design and cost driver, with host plant steam extraction increasing capture system cooling water availability, (2) modularization and constructability impacts on the number of capture trains, (3) the impacts of host plant operational mode and capacity factor on the business case for installing capture, and (4) the merit of continued research, development, and demonstration efforts addressing steam extraction, host plant tie-in at the stack, solvent reclamation and air emissions control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-effective and low-cost carbon capture from point-sources enabled by water-lean solvents

Aqueous amines, as the most mature carbon capture technology, are subject to high energy and cost penalties due to the large water content in their formulations. Emerging technologies are in demand to enable a transition to a low-carbon global economy. However, rigorous process modeling and techno-economic analyses are limited for emerging carbon capture technologies. Here, four CO 2 -Binding Organic Liquids (CO 2 BOLs), all water-lean solvents were presented as promising options towards energy-effective and low-cost carbon capture from point sources. Rigorous solvent property and process models were developed in Aspen Plus for a coal-fired power plant with CO 2 BOL-based carbon capture unit. Techno-economic analyses were conducted in 2018 US pricing basis. The results suggest that water-lean formulations can minimize water condensation and vaporization, leading to a 36% energy saving compared with aqueous amines. Indeed, these CO 2 BOLs can capture up to 97–99% CO 2 from coal fired plant. The estimated carbon capture cost is about $40/tonne CO 2 at 90–97% carbon capture rate, about 12–23% less expensive than the conventional aqueous amine technology. The comparison between these CO 2 BOLs showed that in addition to vapor liquid equilibrium and kinetics (key properties for aqueous solvents), viscosity, volatility, and hydrophobicity, also have strong impacts on the performance of water-lean solvents. The methods presented in this work can be used to evaluate other emerging carbon capture technologies, while the results linking costs and performance of carbon capture solvents with their properties. Additionally, this work identifies research directions and targets for further reductions in total costs of capture from either cost or energy perspectives for these leading water-lean solvents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bench scale development of a hybrid membrane-absorption CO 2 capture process (Final Report)

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept PolarisTM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, low-pressure-drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

20 FOSSIL-FUELED POWER PLANTS↗

Pilot Testing of Amine-Based Solvent at Low-Rank Coal Fired Power System

Conference presentation for the 2023 International Freiberg Conference on Circular Carbon Technologies, Rotterdam, Netherlands, September 24–29, 2023. This presentation describes pilot testing of an amine-based CO₂ capture system at Coal Creek Station, examining solvent performance, system design, and operating conditions for a low-rank coal-fired power plant. The Mitsubishi Heavy Industries KM CDR (KS-1) process is assessed using pilot-scale data to inform capture efficiency, solvent condition, and integration considerations.

01 COAL, LIGNITE, AND PEAT↗

Effect of Packing Nonuniformity at the Fiber Bundle–Case Interface on Performance of Hollow Fiber Membrane Gas Separation Modules

High-fidelity simulations of momentum and mass transfer within a hollow fiber gas separation membrane module are here reported. The simulations capture the potential detrimental effects of poor fiber packing at the bundle–case interface on fluid distribution and performance. Results are presented for both circular and planar fiber bundles. The length over which bundle–case gaps affects flow is determined. The length increases dramatically with increasing fiber packing fraction. As the packing fraction approaches 0.6, the impact extends over the entire bundle diameter for small modules (<1000 fibers). The results clearly demonstrate the detrimental effect of poor packing along the case and can be used to develop module manufacturing guidelines. To reduce computational costs, an equivalent planar bundle module approximation is developed. The approximate simulations agree well with results from full 3-D simulations and can reduce computational costs without sacrificing fidelity.

42 ENGINEERING↗