At least 199 records · Page 11

Development of a Particle Flow Control Mechanism

The next generation of Concentrated Solar Power (CSP) systems are utilizing solid particles as the heat transfer medium. The state-of-the-art particle flow control mechanism currently utilized is the slide-gate mechanism which functions by linearly actuating a gate across a tear-drop shaped opening. The sensitivity, which is a measure of the change in mass flow rate per unit movement of the slide-gate, is 0.354 g/s-mm[1]. The slide-gate’s main shortcomings include particle lodging and particle leakage between the plates, and difficulty actuating under the pressure from the particles. The goal of a new device is to minimize or eliminate these flaws. The new proposed device functions similar to a chuck mechanism in a drill where a rotation of an outer ring produces a change in outlet area through moving “jaws” diagonally. This mechanism aims to solve the issues of the slide-gate by having the jaws on the outside of the particle flow volume to reduce the probability of particle lodging, and the jaw tips are designed to overlap as they actuate to reduce particle leakage. Additionally, the vertical orientation of the device as well as the inclined movement of the jaws allows for easier actuation of the device under pressure. Experiments involving 3D printed prototypes have been carried out, producing a max mass flowrate of about 50 g/s and a sensitivity curve with the equation 𝑦 (𝑔/𝑠) = 0.0851𝑥^2(𝑔/𝑠−𝑚𝑚2) +3.6993𝑥(𝑔/𝑠−𝑚𝑚). These experiments validated the device’s capability to address the shortcomings of the slide-gate. Currently, an aluminum model of the device is being tested at room temperature, and a stainless-steel model is being developed to be tested at 700oC, which is the expected operating temperature of the CSP system. Furthermore, simulations are on-going to predict the mass flowrate of different device configurations at room and high temperatures.

14 SOLAR ENERGY↗

Visualizing Coolant Flow in Sodium Reactor Subassemblies

Uniformity of temperature controls peak power output. Interchannel cross-flow is the principal cross-assembly energy transport mechanism. The areas of fastest flow all occur at the exterior of the assembly. Further, the fast moving region winds around the assembly in a continuous swath. This Nek5000 simulation uses an unstructured mesh with over one billion grid points, resulting in five billion degrees of freedom per time slice. High speed patches of turbulence due to vertex shedding downstream of the wires persist for about a quarter of the wire-wrap periodic length. Credits: Science: Paul Fisher and Aleks Obabko, Argonne National Laboratory. Visualization: Hank Childs and Janet Jacobsen, Lawrence Berkeley National Laboratory. This research used resources of the Argonne Leadership Computing Facility at Argonne National Laboratory, which is supported by the Office of Science of the U.S. Dept. of Energy under contract DE-AC02-06CH11357. This research was sponsored by the Department of Energy's Office of Nuclear Energy's NEAMS program.

42 ENGINEERING↗

Control Electronics for Solar/Flywheel Power Supply

Control circuit automatically directs flow of electrical energy to and from motor with flywheel that constitutes storage element of solar-power system. When insolation is sufficient for charging, power is supplied by solar-cell array to load and motor. During periods of darkness, motor made to act as generator, drawing kinetic energy from flywheel and supplying it to load.

Nola, F. J.↗

Optimal Water-Power Flow Problem: Formulation and Distributed Optimal Solution

This paper formalizes an optimal water-power flow (OWPF) problem to optimize the use of controllable assets across power and water systems while accounting for the couplings between the two infrastructures. Tanks and pumps are optimally managed to satisfy water demand while improving power grid operations; {for the power network, an AC optimal power flow formulation is augmented to accommodate the controllability of water pumps.} Unfortunately, the physics governing the operation of the two infrastructures and coupling constraints lead to a nonconvex (and, in fact, NP-hard) problem; however, after reformulating OWPF as a nonconvex, quadratically-constrained quadratic problem, a feasible point pursuit-successive convex approximation approach is used to identify feasible and optimal solutions. In addition, a distributed solver based on the alternating direction method of multipliers enables water and power operators to pursue individual objectives while respecting the couplings between the two networks. The merits of the proposed approach are demonstrated for the case of a distribution feeder coupled with a municipal water distribution network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VSC-HVDC Interties for Urban Power Grid Enhancement

Urban power grids are facing many operational and expansion challenges to meet further demand growth and increased reliability requirements. Advanced transmission technologies have been considered by the electric utilities to effectively increase the utilization of existing infrastructure and operational flexibility. The focus of this paper is on VSC-HVDC technologies for urban power grid enhancement and modernization. First, a potential technical scheme is proposed for converting an existing AC circuit to DC operation, which could boost the power transfer capability of the critical transmission corridor and increase network operational flexibility. Second, this paper proposes three operation modes for the VSC-HVDC interties in urban power grids corresponding to normal, emergency and island operating conditions, respectively. An integrated, adaptive emergency control strategy (AEC) is proposed that can enable adaptive power flow responses of the VSC-HVDC intertie under varying system operating conditions and critical contingencies. The flexibility and effectiveness of the proposed operational principles of urban VSC-HVDC intertie and the corresponding control strategies are verified in PSCAD/EMTDC using a realistic urban power grid in China.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a Large-scale Virtual Power Grid for Research Community

Due to security and liability concerns, the research community has limited access to realistic large-scale power grid models to test and validate new operation and control methodologies. It is also difficult for industry to evaluate the relative value of competing new tools without a common platform for comparison. This paper proposes to develop a large-scale virtual power grid model that retains basic features and represents future trends of major U.S. electric interconnections. The proposed model will include realistic power flow and dynamics information as well as a relevant geospatial distribution of assets. This model will be made widely available to the research community for various power system stability and control studies and can be used as a common platform for comparing the efficacies of various new technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of High Frequency AC Link Isolated Three Port Resonant Converter for UAV Applications

A high frequency AC link isolated three port semi-bridgeless resonant converter is analyzed for unmanned aerial vehicle (UAV) applications in this study. The proposed topology is established by replacing rectifier lover diodes with synchronous switches. A phase shifted pulse width modulation (PS-PWM) technique adjusts bi-directional power flow between ports. Proposed control technique provides high efficiency by reducing switching losses with zero voltage switching (ZVS) and zero current switching (ZCS) in a wide power range regulation. Compared to integrated PWM converters in a bi-directional mode, the proposed topology reduces the number of converter stages and allows centralized control at high operating frequency. Theoretical and experimental results demonstrate the feasibility and effectiveness of the proposed converter at a full power of 500 W in laboratory conditions.

Asa, Erdem↗

Dynamic ADMM for Real-Time Optimal Power Flow: Preprint

This paper considers distribution networks featuring distributed energy resources (DERs), and develops a dynamic optimization method to maximize given operational objectives in real time while adhering to relevant network constraints. The design of the dynamic algorithm is based on suitable linearizations of the AC power flow equations, and it leverages the so-called alternating direction method of multipliers (ADMM). The steps of the ADMM, however, are suitably modified to accommodate appropriate measurements from the distribution network and the DERs. With the aid of these measurements, the resultant algorithm can enforce given operational constraints in spite of inaccuracies in the representation of the AC power flows, and it avoids ubiquitous metering to gather the state of non-controllable resources. Optimality and convergence of the propose algorithm are established in terms of tracking of the solution of a convex surrogate of the AC optimal power flow problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computer Control For Ion Engines

Computer system controls start-up, steady-state operation, throttling, and shutdown of pair of xenon-ion propulsion engines. Controls direction of thrust of each engine through operation of gimbal stepping motors. Controls valves in propellant-storage and propellant-distribution system. Control software establishes and maintains efficient, stable operation over entire range of operating variables, and throttles engines to any point within range. Computer operates power supplies, valves, and flow controllers of two ion engines, ion-neutralizer subsystem, and other equipment. Designed for use in interplanetary flight, system adaptable to industrial use in ion-beam deposition of thin films.

Brophy, John R.↗

A machine learning-based fast frequency response control for a VSC-HVDC system

An HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation. However, most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control. Since the traditional system frequency control is dominated by the thermal generators, the advantage of the fast response of the HVDC system is not made fully used. The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system. Different from other frequency deviation tracking strategies, a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost. In this paper, a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression (MRFR) algorithm is proposed. The simulation is carried out with an integrated power system model based on the North American interconnections. The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event, while stabilizing the frequency in advance.

42 ENGINEERING↗

Chance-Constrained AC Optimal Power Flow for Distribution Systems With Renewables

This paper focuses on distribution systems featuring renewable energy sources (RESs) and energy storage systems, and presents an AC optimal power flow (OPF) approach to optimize system-level performance objectives while coping with uncertainty in both RES generation and loads. The proposed method hinges on a chance-constrained AC OPF formulation where probabilistic constraints are utilized to enforce voltage regulation with prescribed probability. A computationally more affordable convex reformulation is developed by resorting to suitable linear approximations of the AC power-flow equations as well as convex approximations of the chance constraints. The approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive strategy is then obtained by embedding the proposed AC OPF task into a model predictive control framework. Finally, a distributed solver is developed to strategically distribute the solution of the optimization problems across utility and customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An integrated power/attitude control system /IPACS/ for space vehicle application

An integrated power and attitude control system (IPACS) concept with potential application to a broad class of space missions is discussed. The concept involves the storage and supply on demand of electrical energy in rotating flywheels while simultaneously providing control torques by controlled precession of the flywheels. The system is thus an alternative to the storage batteries used on present spacecraft while providing similar capability for attitude control as that represented by a control moment gyroscope (CMG) system. Potential IPACS configurations discussed include single- and double-rotor double-gimbal IPACS units. Typical sets of control laws which would manage the momentum and energy exchange between the IPACS and a typical space vehicle are discussed. Discussion of a simulation of a typical potential IPACS configuration and candidate mission concerned with pointing capability, power supply and demand flow, and discussion of the interactions between stabilization and control requirements and power flow requirements are presented.

Anderson, W. W.↗

Wide-area Demand-side Control for Inter-area Oscillation Mitigation in Power Systems

Inter-area oscillations have severely limited maximum power transfer among different areas in large-scale interconnected power grid. If not quickly damped as soon as possible, they may cause system breakup and even lead to large cascading blackouts. To increase the damping of inter-area oscillations, both power system stabilizer~(PSS) and flexible AC transmission system~(FACTS) controller have been widely considered, which affect the real power flow indirectly. However, the effectiveness of these controllers is restricted to the neighborhood of a prescribed set of operating conditions. In this paper, wide-area demand-side control is developed to directly modulate the real power of end-user loads for oscillation mitigation. The proposed control strategy is implemented in a hierarchical manner. At the device layer, individual end-user loads independently turn ON or OFF in response to the broadcasted signals from the coordinator during the real time. At the supervisory layer, autonomous responses of end-user loads are coordinated to ensure the desired power modulation. The effectiveness of the proposed wide-area demand-side control in improving small-signal stability is illustrated by simulations on a large-scale test system.

Lian, Jianming↗

Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizes current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.

14 SOLAR ENERGY↗

Studies of advanced transport aircraft

Concepts for possible future airplanes are studied that include all-wing distributed-load airplanes, multi-body airplanes, a long-range laminar flow control airplane, a nuclear powered airplane designed for towing conventionally powered airplanes during long range cruise, and an aerial transportation system comprised of continuously flying liner airplanes operated in conjunction with short range feeder airplanes. Results indicate that each of these concepts has the potential for important performance and economic advantages, provided certain suggested research tasks are successfully accomplished. Indicated research areas include all-wing airplane aerodynamics, aerial rendezvous, nuclear aircraft engines, air-cushion landing systems, and laminar flow control, as well as the basic research discipline areas of aerodynamics, structures, propulsion, avionics, and computer applications.

Nagel, A. L.↗

Model-Predictive Cascade Mitigation in Electric Power Systems With Storage and Renewables-Part I: Theory and Implementation

A novel model predictive control (MPC) scheme is developed for mitigating the effects of severe line-overload disturbances in electrical power systems. A piece-wise linear convex approximation of line losses is employed to model the effect of transmission line power flow on conductor temperatures. Control is achieved through a receding-horizon model predictive control (MPC) strategy which alleviates line temperature overloads and thereby prevents the propagation of outages. The MPC strategy adjusts line flows by rescheduling generation, energy storage and controllable load, while taking into account ramp-rate limits and network limitations. In Part II of this paper, the MPC strategy is illustrated through simulation of the IEEE RTS-96 network, augmented to incorporate energy storage and renewable generation.

Almassalkhi, MR↗

Experimental and Computational Validation of a Novel Particle Flow Control Valve for CSP Systems

Particle-based Concentrated Solar Power (CSP) systems most often utilize the state-of-the art slide gate mechanism for particle flow control. The slide-gate was found to have a sensitivity of 0.354 g/s-mm, a measure of mass flow rate over actuation position [1]. Particle-based CSP developers have noted that the slide gate is conducive to particle lodging, leaking, and difficulty actuating under particle pressure as well as differential expansion of the gate from thermal cycling. The goal of this work is to design, develop and test a novel particle flow control device that can operate without any hindrance from these shortcomings.

14 SOLAR ENERGY↗