Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Prediction of The TREAT Facility Power and Temperature of Sirius-2c Nuclear Propulsion Fuel Experiment

This paper presents simulation results of the Sirius-2c full power experiment that was performed at the TREAT facility to support experiment modeling and transient analysis of the NASA-sponsored Sirius series of experiments for nuclear thermal propulsion applications. We presents a novel approach to predict the control rod motion and power of the reactor and the temperature of the specimen during transient experiments using the Griffin and Bison packages of the Multiphysics Object Oriented Simulation Environment (MOOSE). First, the model predicts the transient rod motion that results in the desired reactor power shape. Then, the temperature of the specimen is predicted based on the power deposited in the specimen. The prediction results are in good agreement with the measured reactor power and control rod position and over-predicted the specimen temperature which is mainly related to specimen surface emissivities. The reactor reaches a peak power of 80 MW and a specimen temperature of 2500 K and considering the right specimen emissivities the predicted temperature is in an excellent agreement with the measured values. This model can be utilized in helping and supporting the design and optimization a new experiments that are going to be irradiated in the TREAT facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust Power System Stability Assessment Against Adversarial Machine Learning-Based Cyberattacks via Online Purification

The increasing complexity associated with renewable generation brings more challenges to power system stability assessment (SA). Data-driven approaches based on machine learning (ML) techniques for stability assessment have received significant research interest and shown their promising performance. However, ML-based models are recognized to be vulnerable to adversarial disturbances, where a slight perturbation to power system measurements could lead to unacceptable errors. To address this issue, this paper develops a novel lightweight mitigation strategy, i.e., robust online stability assessment (ROSA), to enhance the ML-based assessment model against both white-box and the black-box adversarial disturbances (i.e., purification) in the online implementation. The ROSA involves a supervised learning-based module for the primary stability assessment and a self-supervised learning-based module. Further, the two modules are trained jointly with different objective (loss) functions and implemented in sequence. A suitable purification objective and various time-series data augmentation methods are designed for SA applications to tackle adversarial disturbances adaptively. Case studies are performed, and the comparative results have clearly illustrated the competitive, robust accuracy against various adversarial scenarios and verified the effectiveness of the proposed online purification strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory Testing of Portable Air Cleaner Products for Energy Efficiency and Clean Air Performance at Various Fan Settings [Slides]

This document contains the results of a product review and laboratory testing experiment of portable air cleaning devices (PACs). Thirty-four commercially available PACs were reviewed, and from those, 7 products were purchased and underwent AHAM AC-7 clean air delivery rate (CADR) testing. The following research questions were explored: 1) What is the relationship between clean air delivery rate (CADR) and energy across a range of products and what is the general decrement in CADR as a result of operating at lower fan speeds? 2) How might the multiple units at lower power compare to fewer, larger units at full power in terms of energy efficiency and total cost? 3) How do the measured CADR, power, and efficiency compare to the manufacturer specs? 4) Are there product attributes that can be identified that might contribute to better CADR/W performance?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep learning model to detect various synchrophasor data anomalies

High-density synchrophasors provide valuable information for power grid situational awareness, operation and control. Unfortunately, due to factors including communication instability and hardware failure, their data quality can be greatly deteriorated by anomalies. Since the anomalies can impact the performance of the synchrophasor applications, it is of paramount significance to propose a model to detect anomalies in synchrophasor. In this study, a convolutional neural network model is established to detect and classify the anomalies in the synchrophasor measurements. Additionally, four types of anomalies observed in actual synchrophasors including erroneous patterns, random spikes, missing points and high-frequency interferences are considered in this study. The proposed model is extensively evaluated via field-collected measurements from the synchrophasor network in Jiangsu grid, China. The superior performance of the proposed model indicates the great potential of using deep learning for the detection of abnormal synchrophasor measurements.

42 ENGINEERING↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Python Measurement-Informed Modelling Method (PythonMIMM) v1.02

This Python program implements the calculations for electrical energy efficiency and electrical losses in the paper "Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings" (https://www.sciencedirect.com/science/article/abs/pii/S0306261921015658). The inputs are metered voltage, current, or power data of meters located throughout the DC system. In the absence of metered data, the user must input some other information about the building such as the types of power converters or wire lengths. The program will build a loss model of the DC system based on metered data and electrical information. It will also generate an equivalent AC system and determine the losses and efficiency.

Gerber, Daniel [Lawrence Berkeley National Laborat↗

Thermal-striping analysis methodology for sodium-cooled reactor design

Computational fluid dynamics simulations have been performed to study the applicability of engineering CFD methods for thermals striping analysis. Thermal striping is the fluctuating temperature profile in a solid caused by fluctuating fluid temperature, and the resulting fluctuating thermal stresses cause high cycle fatigue and eventual material failure. Here this study presents the methodology for thermal striping analysis that including a transient conjugate heat transfer RANS model and benchmark the results against a sodium triple jet experiment. The multiphysics calculations are implemented to analyze the thermal stresses in the solid domain caused by the coupled heat transfer between the fluid and solid domains. Validation data from a liquid sodium triple jet experiment include time-averaged temperature measurements and power spectra of the temperature signal. The numerical results agree well with these experimental measures, demonstrating key features such as the dominant frequency of temperature fluctuations. The applicability of a low-cost wall treatment method is demonstrated, enabling key computational savings. Finally, the performance of two finite element stress analysis software packages is compared, and the validity of the lower-cost method is confirmed. These results demonstrate the applicability of engineering methods for computational thermal striping calculations, enabling thermal striping estimations in large fluid systems such as the core of a Sodium-cooled nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An 85 nW IoT Node-Controlling SoC for MELs Power-Mode Management and Phantom Energy Reduction

This paper presents an ultra-low power (ULP) node-controlling system-on-chip (SoC) used for power-mode management and phantom energy reduction of miscellaneous electric loads (MELs). The SoC is powered from a single 2.5 V voltage supply enabled by the integrated power management unit (PMU) and can control up to 16 MELs due to the on-chip 16-channel correlator and the 32b RISC-V microprocessor. To further reduce the system power consumption, two clock domains have been adopted for the correlator and the processor separately. Fabricated in 65-nm CMOS, the measured minimum power consumption of the proposed SoC is only 85 nW at 0.45 V voltage supply and 1 kHz clock frequency. The measured maximum operating frequency can go up to 148 kHz with a 0.55 V supply. An application experiment successfully demonstrates that the SoC controls the power modes of MELs from wake-up to cut-off to save the average power and phantom energy.

power-mode management, phantom energy, phantom pow↗

Dynamic Equivalence of Large-Scale Power Systems Based on Boundary Measurements

Parallel computing helped speed up many tasks that can be done independently. The advance in gaming industry did not produce a technology that helps the power industry to reduce the computation time for dynamic simulation in individual cases. To perform faster than real-time simulation for the purpose of predicting power system dynamic trajectory, power industry continues to struggle to reduce the system size and simulation time of large-scale power systems while keeping its dynamic behavior under various disturbances. There is also an acute need for real-time dynamic model reduction as more renewables enter the generation mix with dramatic changes in the generation outputs. All existing model reduction solutions are based on having access to a detailed dynamic model of the system. The system changes by the minutes, dynamic models are only updated annually. To solve this problem, wide-area measurements obtained by the phasor measurement unit (PMU) at the boundaries between the reduced system and the study system is used to represent the external area. An artificial neuro-fuzzy inference system (ANFIS) is established to perform the mapping of the measurement to the external equivalent model. Here the external area is regarded as a black-box. Model reduction studies are conducted on the Northeast Power Coordinating Council (NPCC) under various types of contingencies, by using a co-simulation approach between PSS/E and MATLAB. The results look very promising and will be discussed in this paper.

Tong, Ning↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance and wake flow characterization of a 1:8.7-scale reference USDOE MHKF1 hydrokinetic turbine to establish a verification and validation test database

As hydrokinetic turbine technologies continue to advance towards commercialization, public datasets on the performance characteristics for these devices and their flow field effects are invaluable to advance our understanding of these technologies and to validate analytical and numerical models. The Applied Research Laboratory at The Pennsylvania State University (ARL Penn State) collaborated with Sandia National Laboratories and the University of California at Davis to design, fabricate (at a 1:8.7 scale), and experimentally test a novel hydrokinetic turbine rotor design to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, the near-wake flow, cavitation effects, and noise generation. These state-of-the-art measurements demonstrate much of the complex physics associated with the flow through an unducted, horizontal-axis turbine, and they elucidate the performance characteristics and flow field effects at an unprecedented fidelity, accuracy and resolution. Measurements of powering coefficients (power, torque and thrust) as a function of tip-speed-ratio were performed. The dataset also includes unsteady measurements of driveshaft loading, blade strain, tower pressures, and radiated noise. Detailed flow mapping using laser Doppler velocimetry, and planar and stereo particle image velocimetry includes measurements of mean velocity and Reynolds stresses. Although the wake measurements are limited to less than half a diameter, they reveal the complex flow patterns in the near-wake structure of the rotor. The full database, available at the United States Department of Energy’s marine and hydrokinetic data repository, includes tunnel and model Computer Aided Design geometry files and inflow data sufficient for a “Model-the-Test” computational Verification and Validation study.

13 HYDRO ENERGY↗

Modelling nearest neighbour distributions of biased tracers using hybrid effective field theory

ABSTRACT We investigate the application of hybrid effective field theory (HEFT) – which combines a Lagrangian bias expansion with subsequent particle dynamics from N-body simulations – to the modelling of k-nearest neighbour cumulative distribution functions (kNN-CDFs) of biased tracers of the cosmological matter field. The kNN-CDFs are sensitive to all higher order connected N-point functions in the data, but are computationally cheap to compute. We develop the formalism to predict the kNN-CDFs of discrete tracers of a continuous field from the statistics of the continuous field itself. Using this formalism, we demonstrate how kNN-CDF statistics of a set of biased tracers, such as haloes or galaxies, of the cosmological matter field can be modelled given a set of low-redshift HEFT component fields and bias parameter values. These are the same ingredients needed to predict the two-point clustering. For a specific sample of haloes, we show that both the two-point clustering and the kNN-CDFs can be well-fit on quasi-linear scales (≳ 20h−1Mpc) by the second-order HEFT formalism with the same values of the bias parameters, implying that joint modelling of the two is possible. Finally, using a Fisher matrix analysis, we show that including kNN-CDF measurements over the range of allowed scales in the HEFT framework can improve the constraints on σ8 by roughly a factor of 3, compared to the case where only two-point measurements are considered. Combining the statistical power of kNN measurements with the modelling power of HEFT, therefore, represents an exciting prospect for extracting greater information from small-scale cosmological clustering.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of the inter-species power balance in JET plasmas

Most auxiliary heating methods provide heating to more than one particle species (electrons, ions, impurities) in a fusion plasma. This can lead to substantial temperature differences between species, depending on conditions such as heating power to the different species and collisionality, with temperature differences between species limited by inter-species thermal equipartition and transport. The analysis of the steady-state electron-ion and impurity-ion power balances presented in this paper are used for consistency-checking experimental ion and electron temperature measurements and for inferring the main ion temperature from measured impurity temperatures. As ion temperature measurements by charge exchange spectroscopy (CXS) based on impurity ions have become more difficult and time-consuming since the installation of the ITER-like wall (ILW) with Be and W PFC's, knowing the maximum sustainable temperature difference between ions and electrons, |T i -T e | allows rejecting erroneous measurements. It also obviates the need for an ion temperature measurement, if an electron temperature measurement is available and |T i - T e | cannot be larger than the combined errors of the underlying measurements. A power balance analysis is also required for estimating the errors of the ion and electron heat fluxes prior to any species-resolved transport analysis. The ion-impurity temperature differences are usually found to be small due to strong thermal equipartition between ion species. However, they can approach 10% in JET-ILW low density, high power discharges, such the ones under development for a future JET deuterium–tritium campaign (Joffrin et al 2019 Nucl. Fusion). This has a generally small, but not always negligible effect on the calculation of fusion reaction rates, which depend on main ion temperatures. An important outcome of this analysis is that temperature differences between impurity species are always much smaller than between the impurities and hydrogenic species and can usually be neglected. The article presents two methods for calculating the impurity-to-main ion temperature ratio. Finally, this analysis leads to a method for the reconstruction ion temperature profiles from ion temperature data available at only one or a small number of spatial locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous Purcell decay of strongly driven inhomogeneous emitters coupled to a cavity

We perform resonant fluorescence lifetime measurements on a nanocavity-coupled erbium ensemble as a function of cavity-laser detuning and pump power. Our measurements reveal an anomalous three-fold suppression of the ensemble Purcell factor at zero cavity detuning and high pump fluence. We capture qualitative aspects of this decay rate suppression using a Tavis–Cummings model of non-interacting spins coupled to a common cavity.

36 MATERIALS SCIENCE↗

Tidal Resource Gaps Analysis Technical Report

The tidal resource gaps project was created to address a growing body of evidence that models underpredict tidal current speeds compared to measurements at a number of the top-ranking tidal energy sites. In response, this project compared opportunistic tidal power density measurements from 16 tidal energy hot spot sites with estimates from resource assessment data to identify discrepancies. To improve the accuracy of resource estimates from model data, updated data from eight improved model simulations were obtained. Model improvements included grid refinement, domain coupling, and the use of unstructured or nested grids. New resource estimates were calculated from the updated models, and these data were used to update the tidal hot spots-a list of promising tidal energy sites around the United States.

16 TIDAL AND WAVE POWER↗

Measurement of the small-scale 3D Lyman- α forest power spectrum

Small-scale correlations measured in the Lyman-α (Lyα) forest encode information about the intergalactic medium and the primordial matter power spectrum. In this article, we present and implement a simple method to measure the 3-dimensional power spectrum, P 3D , of the Lyα forest at wavenumbers k corresponding to small, ~ Mpc scales. In order to estimate P 3D from sparsely and unevenly distributed data samples, we rely on averaging 1-dimensional Fourier Transforms, as previously carried out to estimate the 1-dimensional power spectrum of the Lyα forest, P 1D . Further, this methodology exhibits a very low computational cost. We confirm the validity of this approach through its application to Nyx cosmological hydrodynamical simulations. Subsequently, we apply our method to the eBOSS DR16 Lyα forest sample, providing as a proof of principle, a first P 3D measurement averaged over two redshift bins z = 2.2 and z = 2.4. This work highlights the potential for forthcoming P 3D measurements, from upcoming large spectroscopic surveys, to untangle degeneracies in the cosmological interpretation of P 1D .

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗