Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

X-ray diagnostics of imploding plasmas from planar wire arrays composed of Cu and few tracer Al wires on the 1MA pulsed power generator at UNR

Tracer aluminum alloyed wires (Al5056) are used to provide additional information for x-ray diagnostics of implosions of Cu planar wire arrays (PWAs). Specifically, the analysis of combined PWA experiments using the extensive set of x-ray diagnostics is presented. In these experiments, which were conducted at the 1MA pulsed power generator at University of Nevada, Reno, the Z-pinch load consisted of several (eight) Cu alloyed (main material) and one to two Al alloyed (tracer) wires mounted in a single plane row or double parallel plane rows, single planar wire array (SPWA) or double planar wire array (DPWA), respectively. The analysis of x-ray spatially resolved spectra from the main material indicates the increase in the electron temperature T{sub e} near the cathode. In general, the axial gradients in T{sub e} are more pronounced for SPWA than for DPWA due to the more 'columnlike' plasma formation for SPWA compared to 'hot-spot-like' plasma formation for DPWA. In addition, x-ray spectra from tracer wires are studied, and estimated plasma parameters are compared with those from the main material. It is observed that the x-ray K-shell Al spectra manifest more opacity features for the case of SPWA with about 18% of Al mass (to the total load mass) compared to the case of DPWA with about 11% of Al mass. The analysis of time-gated spectra shows that the relative intensity of the most intense K-shell Al line, small before the x-ray burst, increases with time and peaks close to the maximum of the sub-keV signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the effects of a thin dielectric layer on low-pressure hydrogen capacitive discharges driven by combined radio frequency and pulse power sources

Negative hydrogen ion sources, for instance for fusion devices, currently attract considerable attention. To generate the precursors—highly rovibrationally excited hydrogen molecules—for negative hydrogen ions effectively by electron excitation, a thin dielectric layer is introduced to cover the surface of the electrically grounded electrode of two parallel metal plates in a low-pressure hydrogen capacitive discharge driven by combined rf and pulse power sources. To understand the characteristics of such discharges, particle-in-cell simulations are conducted to study the effects that the single dielectric layer would bring onto the discharges. The simulation results show that the dielectric layer leads to a much higher plasma density and a much larger production rate of highly vibrationally excited hydrogen molecules compared to discharges without the dielectric layer on the electrode. Further investigation indicates that the nonlinear oscillation of the electrons induced by the nanosecond-pulse continues until it is finally damped down and does not show any dependence on the pulse plateau-time, which is in stark contrast to the case without the dielectric layer present. The physical reason for this phenomenon is explored and explained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the Mercury pulsed power x-ray source spectrum using multichannel density aerogel Cherenkov detectors

The Aerogel Cherenkov Detector for Cygnus (ACD/C) is a time-dependent, x-ray spectral detector that uses SiO 2 aerogels spanning an index of refraction (n = 1.02–1.07) corresponding to a 1.1–2.3 MeV x-ray energy threshold. The ACD/C was developed for pulsed power x-ray sources like Cygnus located at the Nevada National Site and Mercury located at the Naval Research Laboratory (NRL). Aerogels sit between the measurement capabilities of gas (>2 MeV) and solids such as fused silica (>0.3 MeV). The detector uses an aluminum converter to Compton scatter incoming x-rays and create relativistic electrons, which produce Cherenkov light in an aerogel or a fused silica medium. The ACD/C was fielded at the NRL when Mercury was tuned to produce up to 4.8 MeV endpoint bremsstrahlung. Despite a high radiation and electromagnetic interference background, the ACD/C was able to achieve high signal over noise across five aerogel densities and fused silica, including a signal to noise for a 1.1 MeV aerogel threshold. Previous experiments at Cygnus observed a signal that was comparable to the noise (1×) at the same threshold. The ACD/C observed time-resolved rise and fall times for different energy thresholds of the photon spectrum. Finally, Monte Carlo simulations of the ACD/C’s aerogel response curves were folded with a simulation of Mercury’s photon energy spectrum and agree within the error to the observed result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power-Pulse Thrombolysis and Stent Recanalization for Acute Post-Liver Transplant Iliocaval Venous Thrombosis

Postoperative inferior vena cava (IVC) thrombosis is a potentially lethal complication in a liver transplant recipient. We report the case of a 57-year-old liver transplant recipient, who developed acute, postoperative, markedly symptomatic complete IVC, ilial-femoral-caval, and left renal vein thrombosis. After treatment with power-pulse tissue plasminogen activator thrombolysis, thrombectomy, and stent placement, the IVC and iliac veins were successfully recanalized. At 2.5-year imaging and laboratory follow-up, the IVC, iliac, and renal veins remained patent and graft function was preserved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating radiatively driven, magnetized plasmas with a university scale pulsed-power generator

We present first results from a novel experimental platform that is able to access physics relevant to topics including indirect-drive magnetized inertial confinement fusion, laser energy deposition, various topics in atomic physics, and laboratory astrophysics (for example, the penetration of B-fields into high energy density plasmas). This platform uses the x rays from a wire array Z-pinch to irradiate a silicon target, producing an outflow of ablated plasma. The ablated plasma expands into ambient, dynamically significant B-fields (∼5 T), which are supported by the current flowing through the Z-pinch. The outflows have a well-defined (quasi-1D) morphology, enabling the study of fundamental processes typically only available in more complex, integrated schemes. Experiments were fielded on the MAGPIE pulsed-power generator (1.4 MA, 240 ns rise time). On this machine, a wire array Z-pinch produces an x-ray pulse carrying a total energy of ∼15 kJ over ∼30 ns. This equates to an average brightness temperature of around 10 eV on-target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental development of rod pinch diode radiographic source using modified KALI 1000 pulsed power system

This paper highlights the development of Rod Pinch (RP) diode for flash X-ray generation as intense radiographic source at BARC, Vizag. The typical RP diode employed used a small diameter (1-2 mm) anode rod extended through a cathode circular aperture (5-6 mm inner diameter). The diode chamber is maintained at 10{sup -5} Torr vacuum by a rotary backed diffusion pump. Experiments performed on a modified Kali 1000 Pulsed Power System (300 kV, 30 kA, 100 ns) were aimed at optimizing the source by maximizing the figure of merit (dose @ 1m in rad/spot diameter{sup 2} in mm{sup 2}) with minimizing of the diode impedance. The typical electron beam parameters used in the experiments are 240-270 kV, 20-25 kA, 100 ns, with a few hundreds of kA/cm{sup 2} current density. The optimization resulted in a configuration with tungsten anode rod having dimensions of a 1.6 mm diameter, tapering extension length 5-25 mm beyond the graphite cathode aperture (Cathode disk ID = 5 mm, thickness = 3mm) to produce a radiation dose of 150-200 milli rad at 1 m distance having an estimated spot-size of 1-2 mm. The radiation emitted from a rod-pinch diode is measured using Thermoluminescence dosimeters (TLDs) at an angular interval of 15° on either side of the rod in horizontal and vertical plane. (author)

43 PARTICLE ACCELERATORS↗

Multi-nanosecond high power pulse generation at 7.8GHz with a dielectric-loaded power extractor.

Power extraction from charged particle beams is a prospective way to develop future high power radio frequency (RF) sources. We have designed and tested a 7.8 GHz power extractor based on a dielectric-loaded waveguide. Building upon earlier work on single electron bunch tests, 10 ns and 22 ns megawatt-level RF pulses have been generated with trains consisting of 16 electron bunches each, by using a laser splitting-recombination scheme. In addition, 44 MW of peak power has been generated with a train consisting 4 electron bunches. Behaviors of higher-order-modes are also explored.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cost‐Effective Layered Oxide – Olivine Blend Cathodes for High‐Rate Pulse Power Lithium‐Ion Batteries

Abstract Sustainability and supply‐chain concerns require lithium‐ion batteries (LIBs) free from critical minerals, such as nickel and cobalt. While recent advances provide encouraging signs that cobalt can be removed, the question remains how much Ni can be removed from Co‐free layered oxide cathodes before sacrificing critical performance metrics. This study highlights the effect of reducing Ni by benchmarking several Co‐free cathodes with decreasing Ni content. Keeping the energy density the same by increasing the charge voltage, cathodes below 80% Ni content exhibit worsened capacity fade due to increasing oxygen release and electrolyte decomposition. Charge transfer and diffusion kinetics are also hindered with increasing Mn content and exacerbated by resistive surface phases formed at high voltages, rendering lower‐Ni, Co‐free cathodes less competitive than high‐Ni cathodes for high energy and power applications. It is demonstrated blending layered oxide with olivine as an effective alternative to deliver energy density and cycling stability comparable to lower‐Ni cathodes with moderate charging voltages. Blending with 30 wt% olivine LiMn 0.5 Fe 0.5 PO 4 (LMFP) virtually eliminates the diffusion limitation of layered oxides at low state‐of‐charge, with enhanced pulse power characteristics rivaling the high‐Ni counterparts. Cathode blending can further reduce the overall Ni content and cost without the performance limitations of lower‐Ni, Co‐free cathodes.

Lee, Steven↗

Electrode Erosion and Prefire Studies Towards Fusion Scale Pulsed Power

This study presents a comprehensive investigation of electrode erosion and discharge behavior in spark gap switches over long switching cycle lifetimes. Brass, copper–tungsten (CuW), and stainless steel electrodes are tested under controlled conditions to quantify material degradation, debris accumulation, and changes in breakdown voltage. High-resolution imaging and statistical analysis of spark channel locations and gap breakdown voltages reveal how surface evolution influences long-term performance and reliability. These results provide essential data for lifetime modeling and inform design strategies for pulsed power systems in emerging applications such as private sector fusion energy and large-scale facilities like Sandia’s Z Machine and proposed ZX upgrades, where high repetition reliability and predictable behavior are critical.

electrical breakdown↗

Plasma formation and dynamics in conical wire arrays in the Llampudken pulsed power generator

Plasma formation and dynamics from conical wire array is experimentally studied. Ablation from the wires is observed, forming plasma accumulation at the array axis and subsequently a jet outflow been expelled toward the top of the array. The arrays are composed by 16 equally spaced 25μ diameter tungsten wires. Their dimensions are 20mm height, with base diameters of 8mm and 16mm top diameter. The array loads are design to be overmassed, hence no complete ablation of the wires is observed during the current rise. The experiments have been carried out in the Llampudken. pulsed power generator (∼350kA in ∼350ns). Plasma dynamics is studied in both side-on and end-on directions. Laser probing (shadowgraphy) is achieved using a frequency doubled Nd:YAG laser (532nm, 12ps FWHM) captured by CCD cameras. Pinhole XUV imaging is captured using gated microchannel plate cameras with time resolution ∼5ns. Results on the jet velocity and the degree of collimation indicating the plausibility on the use of these jets as comparable to the study astrophysically produced jets are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NDCX-II PULSED POWER SYSTEM AND INDUCTION CELLS

The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL) is currently finalizing the design of NDCX-II, the second phase of the Neutralized Drift Compression Experiment, which will use an ion beam to explore Warm Dense Matter (WDM) and Inertial Fusion Energy (IFE) target hydrodynamics. The ion induction accelerator will include induction cells and Blumleins from the decommissioned Advanced Test Accelerator (ATA) at Lawrence Livermore National Laboratory (LLNL). A test stand has been built at Lawrence Berkeley National Laboratory (LBNL) to test refurbished ATA induction cells and pulsed power hardware for voltage holding and ability to produce various compression and acceleration waveforms. The performance requirements, design modifications, and test results will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature-dependent stability of energy storage properties of Pb{sub 0.97}La{sub 0.02}(Zr{sub 0.58}Sn{sub 0.335}Ti{sub 0.085})O{sub 3} antiferroelectric ceramics for pulse power capacitors

The dielectric properties and electrical hysteresis behaviors of Pb{sub 0.97}La{sub 0.02}(Zr{sub 0.58}Sn{sub 0.335}Ti{sub 0.085})O{sub 3} antiferroelectric (AFE) ceramics were investigated in this work with an emphasis on energy storage properties. Three phase transition points can be detected as temperature increases. AFE and paraelectric phases are found to coexist from 100 °C to 170 °C. The room temperature recoverable energy density is 1.37 J/cm{sup 3} at 8.6 kV/mm. With increasing temperature (from 20 °C to 100 °C) and frequency (from 0.01 to 100 Hz) under 8.6 kV/mm, the variation of recoverable energy density was less than 15%, all higher than 1.2 J/cm{sup 3}. All the corresponding energy efficiencies were no less than 75%. The high energy density, high energy efficiency, and their weak dependence on temperature and frequency during a wide scope indicate that these antiferroelectric ceramics are quite promising to be used for pulse power capacitors applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximized Information Gain of Next Generation Pulsed Power Using Optimized Design of Z-Machine Experiments

This project develops a Bayesian optimization approach to extracting insights from Z Machine experimental data to determine if and how these insights can be used to extrapolate to a larger facility. The primary goal is to address the scientific challenge of informing how confidently experimental conditions can be predicted on a next generation facility, the design of which requires the reliable extrapolation of current high energy density technologies to regimes yet unobserved, except by costly high-fidelity computational models. Maximizing the use of presently available data and understanding how it informs future endeavors is critically important to enable transformative pulsed power and the science of extreme conditions. We explore a Bayesian optimization approach to experimental design which combines information theory, experimental data, and computational modeling to explore how information gain can be maximized.

97 MATHEMATICS AND COMPUTING↗

Field-Distortion Air-Insulated Switches for Next-Generation Pulsed-Power Accelerators

We have developed two advanced designs of a field-distortion air-insulated spark-gap switch that reduce the size of a linear-transformer-driver (LTD) brick. Both designs operate at 200 kV and a peak current of ~50 kA. At these parameters, both achieve a jitter of less than 2 ns and a prefire rate of ~0.1% over 5000 shots. We have reduced the number of switch parts and assembly steps, which has resulted in a more uniform, design-driven assembly process. We will characterize the performance of tungsten-copper and graphite electrodes, and two different electrode geometries. The new switch designs will substantially improve the electrical and operational performance of next-generation pulsed-power accelerators.

36 MATERIALS SCIENCE↗

Self-assembled Seashell Like Coatings for Large Area Robust Debris Shields for Next Generation Pulsed Power Drivers

During this LDRD project, our team developed a technology which enables the fabrication of novel nanostructures replicating seashell – “nature’s toughest material”. The resulting coatings exhibit high thermal stability up to 1650°C, which exceeds the hardness of Spectra® by ~44%, as well as the compressive strength of aluminum by ~57%. Coatings made with this technology are stronger, environmentally friendly, more sustainable, and more versatile than other comparable materials. Beryllium wafers, the current, most favorable shielding material in terms of thermal and mechanical properties, are very toxic and cost hundreds of times more than the new material developed in this project. The coatings on silicon wafer and stainless steel, respectively, have been tested as ride-along on the Z machine and clearly outperform the bare substrate. Use of this technology will have a profound global impact for pulsed power and fusion energy development, debris mitigation for spacecraft and satellites, durability of drill bits used in deep well drilling and tunnel boring operations, thermal protection of aircraft and manned spacecraft, and various other thermal and mechanical protection applications.

36 MATERIALS SCIENCE↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Preliminary investigation of a low power pulsed arcjet thruster

A type of pulsed arcjet is examined which operates with gaseous helium propellant at powers from 100 to 1500 W and pulse rats from 360 to 6000 pulses per second. During the pulse, peak power is 50 to 250 kW generating chamber pressures of 10 to 50 atmospheres. The high operating pressure substantially reduces ionization in the 2.5 mm diameter x 12.5 mm long capillary and lowers frozen flow losses in the nozzle. The thruster thermal efficiency, measured calorimetrically, is 43 percent at 440 W and 8 mg/sec helium mass flow rate. Thruster performance trends are predicted by a time-dependent lumped-parameter model which includes heat exchange between the propellant and the wall. The model substantially underpredicts the experimental thermal efficiency values. Alternative thruster configurations yielding significant improvements in thrust efficiency and specific impulse are discussed.

Taylor, Russell D.↗