Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Tangent gradient concentration material for battery, digital gradient concentration material for battery

The invention provides a cathode active material having a discrete change in concentrations of a first base region and a second pulse region. Also provided is a method for preparing a cathode active material, the method having the steps: supplying chelating agent, aqueous basic solution and a first aqueous metal salt solution to a reactor to create a base region; supplying a second aqueous metal-salt solution to a reactor to form a pulse region, wherein the second aqueous metal-salt solution is intermittently or continuously added during or after the creation of the base region; thermally treating the base region and the pulse region to create active metal precursors; mixing the precursors with lithium salt to produce a mixture; and thermally treating the mixture.

Shin, YoungHo↗

Magnetic Flux Compression Reactor Concepts for Spacecraft Propulsion and Power (MSFC Center Director's Discretionary Fund; Project No. 99-24)

This technical publication (TP) examines performance and design issues associated with magnetic flux compression reactor concepts for nuclear/chemical pulse propulsion and power. Assuming that low-yield microfusion detonations or chemical detonations using high-energy density matter can eventually be realized in practice, various magnetic flux compression concepts are conceivable. In particular, reactors in which a magnetic field would be compressed between an expanding detonation-driven plasma cloud and a stationary structure formed from a high-temperature superconductor are envisioned. Primary interest is accomplishing two important functions: (1) Collimation and reflection of a hot diamagnetic plasma for direct thrust production, and (2) electric power generation for fusion standoff drivers and/or dense plasma formation. In this TP, performance potential is examined, major technical uncertainties related to this concept accessed, and a simple performance model for a radial-mode reactor developed. Flux trapping effectiveness is analyzed using a skin layer methodology, which accounts for magnetic diffusion losses into the plasma armature and the stationary stator. The results of laboratory-scale experiments on magnetic diffusion in bulk-processed type II superconductors are also presented.

Litchford, R. J.↗

Enhancing TREAT’s Pulsing Capabilities Using TREAT Upgrade Fuel

The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory is an air-cooled, thermal, heterogeneous facility used to test reactor materials in simulated accident conditions by inducing fission heating with intense neutron pulses. TREAT operated from 1959 until 1994 with the primary goal of testing fast reactor fuels and was brought back online in 2017 to re-establish DOE's nuclear fuels transient testing capabilities. Beginning in the late 1970s, Idaho National Laboratory worked in conjunction with other organizations to increase TREAT's capability for in-pile testing. While these upgrades had not been implemented by the time the reactor was put into standby mode, new assemblies and graphite-urania fuel blocks with increased uranium concentrations had already been designed and fabricated. This project, as part of Idaho National Laboratory's Department of Reactor Physics, modeled the TREAT Upgrade (TU) fuel assemblies in MCNP and implemented them in an existing TREAT model. Calculations were performed using INL's high performance computer to find a critical combination of TU and standard fuel and this geometry's excess reactivity. Future work will include calculating a power coupling factor in the experiment, determining power peaking factors throughout the core, and assessing how much reactivity would be added by replacing the Inconel-625 cladding with silicon carbide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a systematic approach for safety assessment of PLD based equipment of I and C systems - 354

Nuclear power plants (NPPs) increasingly apply digital equipment for instrumentation and control (I and C) systems. During the life cycle of NPPs the operators, designers and manufactures are facing the need to replace or upgrade obsolete equipment or to implement new digital I and C systems. A relatively new challenge in this area is the deployment of programmable logic devices (PLDs) for the equipment of I and C systems. Regulatory approval for safety and safety related I and C systems demands confirmation of evidence that design as well as verification and validation (V and V) processes have ensured that the application of new equipment will fulfil safety and reliability requirements and its intended design function. The objective of the recent research project of GRS is developing a systematic approach for the assessment of PLD-based equipment in safety and safety-related I and C systems regarding the fulfilment of regulatory requirements and identification of undesired failure effects. A generic approach for the safety-oriented assessment of PLD-based equipment has been developed, based on the principles of a Plan-Do-Check-Act (PDCA) cycle. The approach comprises planning of the assessment, predefined analysis steps and methodologies, as well as required input information, criteria for decision making process, the tasks concerning identification of improvement potential and determining documentation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutronics Calculations for a Hypothetical Plasma-Jet-Driven Magneto-Inertial-Fusion Reactor

We present neutronics calculations for a hypothetical fusion reactor based on the repetitively pulsed concept of plasma-jet-driven magneto-inertial fusion (PJMIF). A PJMIF reactor is envisioned to have a replaceable, 3-m-radius spherical metal first wall exposed to 14.1-MeV neutrons, a fast-flowing FLiBe liquid blanket (with thickness 0.75 m) behind the first wall serving as the primary coolant and tritium-breeding medium, and finally an outer structural spherical wall shielded by the blanket. Cylindrical penetrations through both walls and the flowing blanket allow for hundreds of plasma-gun drivers to inject hypersonic plasma jets that form both the DT plasma target and high-Z spherically imploding plasma liner to compress the target. This research is the first to conduct Monte Carlo N Particle (MCNP6.2) and CINDER2008 neutronics calculations relevant to the PJMIF reactor configuration, with the primary objectives of (1) determining the neutron flux as a function of blanket thickness in the blanket and key reactor components and (2) the tritium production rate in the liquid blanket. These results will be used to estimate other quantities of interest, such as first-wall and gun-electrode lifetimes based on DPA accumulation, optimum blanket thickness, activation level of the outer wall and xenon liner, and achievable tritium-breeding ratios. Energy dependent flux tallies were used to calculate neutron flux inside the FLiBe blanket and outer wall, as well as the cylindrical ports where plasma guns are located. Tally multipliers of the flux in MCNP6.2 estimated tritium breeding ratio, DPA, and nuclear heating, while the depletion code CINDER2008 was used to compare tritium breeding ratios with MCNP6.2 and calculate activation of the outer wall and xenon liner. These calculations provide a baseline for blanket requirements necessary for power production in a PJMIF reactor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Catalytic recombination of dissociation products with Pt/SnO2 for rare and common isotope long-life, closed-cycle CO2 lasers

This paper reports results on recombination of pulsed CO2 laser dissociation products with Pt/SnO2 catalysts, and supporting studies in a surrogate laboratory catalyst reactor. The closed-cycle, pulsed CO2 laser has been continuously operated for one million pulses with an overall power degradation of less than 5 percent by flowing the laser gas mixture through a 2-percent Pt/SnO2 catalyst bed. In the surrogate laboratory reactor, experiments have been conducted to determine isotopic exchange with the catalyst when using rare-isotope gases. The effects of catalyst pretreatment, sample weight, composition, and temperature on catalyst efficiency have also been determined.

Brown, Kenneth G.↗

2013 Caliban and Prospero experiments for the study of the behavior of radiation protection instrumentations in case of a criticality accident - 14346

Experiments using the CALIBAN and PROSPERO reactors were performed in 2013 in the framework of a collaboration between IRSN and CEA. The objective was to provide data about the possibility to use information given by radiation protection instrumentations (RPI) in the case of a criticality accident. In that purpose, the behavior of RPI was studied for various kinetics of the reactors which simulated different starts of a criticality accident. The article presents the safety issues associated with these experiments, i.e. the possible use of information given by the RPI for the emergency response of a criticality accident (detection of the accident, triage of the personnel, follow-up of the accident and reentry). Then, one paragraph is dedicated to the presentation of the tested material. In addition, the CALIBAN and PROSPERO reactors are briefly described, followed by the performed experiments. The RPI are neither designed nor dedicated to be used in case of a criticality accident. However, the preliminary conclusion of the experiments performed in 2013 is that the tested RPI have a correct behavior for slow kinetic experiments performed with the PROSPERO reactor, but might give less reliable and accurate information for pulse experiments performed with the CALIBAN reactor. In the last case, they can nevertheless provide information that can be helpful for the emergency response and the limitation of the consequences of the criticality accident. However, if the RPI are included in the emergency response of a criticality accident (detection, triage, follow-up, reentry), emergency procedures should be adapted. Other experiments might be performed in order to confirm results and to extend the number of tested materials, in particular portable survey meters or contamination area monitors. (authors)

42 ENGINEERING↗

Real-time MSE measurements for current profile control on KSTAR

To step up from current day fusion experiments to power producing fusion reactors, it is necessary to control long pulse, burning plasmas. Stability and confinement properties of tokamak fusion reactors are determined by the current or q profile. In order to control the q profile, it is necessary to measure it in real-time. A real-time motional Stark effect diagnostic is being developed at Korean Superconducting Tokamak for Advanced Research for this purpose. This paper focuses on 3 topics important for real-time measurements: minimize the use of ad hoc parameters, minimize external influences and a robust and fast analysis algorithm. Specifically, we have looked into extracting the retardance of the photo-elastic modulators from the signal itself, minimizing the influence of overlapping beam spectra by optimizing the optical filter design and a multi-channel, multiharmonic phase locking algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Yield of delayed neutrons in the thermal-neutron-induced reaction {sup 245}Cm(n, f)

The yield of delayed neutrons, v{sub d}, from thermal-neutron-induced fission of {sup 245}Cm is measured. Experiments aimed at studying the properties of delayed neutrons from the fission of some reactor isotopes and initiated in 1997 were continued at the upgraded Isomer-M facility by a method according to which a periodic irradiation of a sample with a pulsed neutron beam from the IBR-2 reactor was accompanied by recording emitted neutrons in the intervals between the pulses. The accuracy of the resulting total delayed-neutron yield v{sub d} = (0.64 {+-} 0.02)% is two times higher than that in previous measurements. This work was performed at the Frank Laboratory of Neutron Physics at the Joint Institute for Nuclear Research (JINR, Dubna).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transient Catalytic Reaction Analysis Through Signal Defragmentation

The Temporal Analysis of Products (TAP) pulse response technique provides valuable insights into catalytic function and reaction kinetics. However, complex fragmentation patterns in the TAP mass spectrometry signals can complicate precise quantification, particularly when analyzing transient gas flux data typical of TAP experiments. This work demonstrates a standard defragmentation method that deconvolves transient TAP signals while maintaining the temporal resolution of the experiment. First, the integrals of calibration gas fluxes are used to determine the fingerprint fragmentation pattern and construct a fragmentation matrix. This matrix is then used to defragment experimental flux data at each recorded time point via a non-negative least squares regression. The effectiveness of this method is demonstrated using virtual data and control experiments with a TAP reactor system. The defragmentation is then applied to the more complex propane dehydrogenation reaction on a chromia/alumina catalyst, which can contain up to ten significant gas species in the reactor outlet. Initial propane pulsing reveals an induction period during which propane is fully oxidized to CO2, followed by partial reduction to CO. Afterwards, there is a transition in chemistries towards coking and propylene production. Our example illustrates a practical method for the accurate determination of the time-dependent reactant/product concentrations and rates for a thorough analysis of the propane dehydrogenation kinetics. This approach can be broadly applied to any transient mass spectrometry experiment for a better understanding of catalyst-reaction dynamics.

36 - MATERIALS SCIENCE↗

Measurement of deposition rate and ion energy distribution in a pulsed dc magnetron sputtering system using a retarding field analyzer with embedded quartz crystal microbalance

A compact retarding field analyzer with embedded quartz crystal microbalance has been developed to measure deposition rate, ionized flux fraction, and ion energy distribution arriving at the substrate location. The sensor can be placed on grounded, electrically floating, or radio frequency (rf) biased electrodes. A calibration method is presented to compensate for temperature effects in the quartz crystal. The metal deposition rate, metal ionization fraction, and energy distribution of the ions arriving at the substrate location are investigated in an asymmetric bipolar pulsed dc magnetron sputtering reactor under grounded, floating, and rf biased conditions. The diagnostic presented in this research work does not suffer from complications caused by water cooling arrangements to maintain constant temperature and is an attractive technique for characterizing a thin film deposition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advance High Temperature Inspection Capabilities for Small Modular Reactors: Part 1 - Ultrasonics

The project objective was to investigate the development non-destructive evaluation techniques for advanced small modular reactors (aSMR), where the research sought to provide key enabling inspection technologies needed to support the design and maintenance of reactor component performance. The project tasks for the development of inspection techniques to be applied to small modular reactor are being addressed through two related activities. The first is focused on high temperature ultrasonic transducers development (this report Part 1) and the second is focused on an advanced eddy current inspection capability (Part 2). For both inspection techniques the primary aim is to develop in-service inspection techniques that can be carried out under standby condition in a fast reactor at a temperature of approximately 250°C in the presence of liquid sodium. The piezoelectric material and the bonding between layers have been recognized as key factors fundamental for development of robust ultrasonic transducers. Dielectric constant characterization of bismuth scantanate-lead titanate ((1-x)BiScO 3 -xPbTiO 3 ) (BS-PT) has shown a high Curie temperature in excess of 450°C , suitable for hot stand-by inspection in liquid metal reactors. High temperature pulse-echo contact measurements have been performed with BS-PT bonded to 12.5 mm thick 1018-low carbon steel plate from 20C up to 260 C. High temperature air-backed immersion transducers have been developed with BS-PT, high temperature epoxy and quarter wavlength nickel plate, needed for wetting ability in liquid sodium. Ultrasonic immersion measurements have been performed in water up to 92C and in silicone oil up to 140C. Physics based models have been validated with room temperature experimental data with benchmark artifical defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rocky Flats Neutron Detector Testing at Valduc, France

Recent program requirements of the US Department of Energy/NNSA have led to a need for a criticality accident alarm system to be installed at a newly activated facility. The Criticality Safety Group of the Lawrence Livermore National Laboratory (LLNL) was able to recover and store for possible future use approximately 200 neutron criticality detectors and 20 master alarm panels from the former Rocky Flats Plant in Golden, Colorado when the plant was closed. The Criticality Safety Group participated in a facility analysis and evaluation, the engineering design and review process, as well as the refurbishment, testing, and recalibration of the Rocky Flats criticality alarm system equipment to be used in the new facility. In order to demonstrate the functionality and survivability of the neutron detectors to the effects of an actual criticality accident, neutron detector testing was performed at the French CEA Valduc SILENE reactor from October 7 to October 19, 2010. The neutron detectors were exposed to three criticality events or pulses generated by the SILENE reactor. The first excursion was performed with a bare or unshielded reactor, and the second excursion was made with a lead shielded/reflected reactor, and the third excursion with a polyethylene reflected core. These tests of the Rocky Flats neutron detectors were performed as a part of the 2010 Criticality Accident Alarm System Benchmark Measurements at the SILENE Reactor. The principal investigators for this series of experiments were Thomas M. Miller and John C. Wagner of the Oak Ridge National Laboratory, with Nicolas Authier and Nathalie Baclet of CEA Valduc. Several other organizations were also represented, including the Y-12 National Security Complex, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, CEA Saclay, and Babcock International Group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Deposition of Crystalline Ta 3 N 5 Thin Films on FTO for PEC Water Splitting

Tantalum Nitride is a promising photoanode material for solar water splitting, but the further study and practical use is constrained by the harsh conditions of the synthesis from Ta metal. Here we report the direct deposition of crystalline Ta 3 N 5 on FTO substrate via a custom-built ALD system. A combination of TaCl 5 (Ta-precursor) and ammonia (N-source) were sequentially pulsed into the ALD reactor with the substrate heated to 550 °C to deposit compact and thin films of Ta 3 N 5 with controllable thicknesses on FTO substrates. Importantly, it is shown that the FTO is chemically and structurally stable under the reducing conditions of ammonia at 550 °C. These electrodes produced an exceptional photocurrent onset potential of ~ 0.3 V vs. RHE with a maximum photocurrent of ~ 2.4 mA cm -2 at 1.23 V vs RHE. Results of photoelectrochemical investigations as a function of film thickness and illumination direction reveal that the performance of Ta 3 N 5 is controlled by a hole diffusion length of ~50 nm. These results are crucial for the successful integration of Ta 3 N 5 in efficient unassisted water splitting applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Learning plasma dynamics and robust rampdown trajectories with predict-first experiments at TCV

The rampdown phase of a tokamak pulse is difficult to simulate and often exacerbates multiple plasma instabilities. To reduce the risk of disrupting operations, we leverage advances in Scientific Machine Learning (SciML) to combine physics with data-driven models, developing a neural state-space model (NSSM) that predicts plasma dynamics during Tokamak à Configuration Variable (TCV) rampdowns. The NSSM efficiently learns dynamics from a modest dataset of 311 pulses with only five pulses in a reactor-relevant high-performance regime. The NSSM is parallelized across uncertainties, and reinforcement learning (RL) is applied to design trajectories that avoid instability limits. High-performance experiments at TCV show statistically significant improvements in relevant metrics. A predict-first experiment, increasing plasma current by 20% from baseline, demonstrates the NSSM’s ability to make small extrapolations. The developed approach paves the way for designing tokamak controls with robustness to considerable uncertainty and demonstrates the relevance of SciML for fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast-Neutron Source Based on Plasma-Focus Device

This paper describes investigations of neutrons produced by small plasma focus device PF-6 operating in the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland. Main parameters of neutron radiation have been measured by scintillation probe, and by activation technique. Current derivative probe has also been applied to measure dI/dt signal. Simultaneously neutron transport calculations have been carried out by Monte Carlo method. Finally, experimental measurements and numerical calculations have allowed concluding that plasma focus devices can be useful pulse neutron sources for different applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗