Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Quantitation and detection of vanadium in biologic and pollution materials

A review is presented of special considerations and methodology for determining vanadium in biological and air pollution materials. In addition to descriptions of specific analysis procedures, general sections are included on quantitation of analysis procedures, sample preparation, blanks, and methods of detection of vanadium. Most of the information presented is applicable to the determination of other trace elements in addition to vanadium.

Gordon, W. A.↗

Quantitative values of blood flow through the human forearm, hand, and finger as functions of temperature

A literature search was made to obtain values of human forearm, hand and finger blood flow as functions of environmental temperature. The sources used include both government and laboratory reports and the research presented in the open literature. An attempt was made to review many of the more quantitative noninvasive determinations and to collate the results in such a way as to yield blood flow values for each body segment as continuous functions of temperature. A brief review of the various ways used to measure blood flow is included along with an abstract of each work from which data was taken.

Montgomery, L. D.↗

Quantitative multielement analysis using high energy particle bombardment

Charged particles ranging in energy from 0.8 to 4.0 MeV are used to induce resonant nuclear reactions, Coulomb excitation (gamma X-rays), and X-ray emission in both thick and thin targets. Quantitative analysis is possible for elements from Li to Pb in complex environmental samples, although the matrix can severely reduce the sensitivity. It is necessary to use a comparator technique for the gamma-rays, while for X-rays an internal standard can be used. A USGS standard rock is analyzed for a total of 28 elements. Water samples can be analyzed either by nebulizing the sample doped with Cs or Y onto a thin formvar film or by extracting the sample (with or without an internal standard) onto ion exchange resin which is pressed into a pellet.

Clark, P. J.↗

The rapid quantitation of the filamentous blue-green alga plectonema boryanum by the luciferase assay for ATP

Plectonema boryanum is a filamentous blue green alga. Blue green algae have a procaryotic cellular organization similar to bacteria, but are usually obligate photoautotrophs, obtaining their carbon and energy from photosynthetic mechanism similar to higher plants. This research deals with a comparison of three methods of quantitating filamentous populations: microscopic cell counts, the luciferase assay for ATP and optical density measurements.

Bush, V. N.↗

An introduction to quantitative remote sensing

The quantitative approach to remote sensing is discussed along with the analysis of remote sensing data. Emphasis is placed on the application of pattern recognition in numerically oriented remote sensing systems. A common background and orientation for users of the LARS computer software system is provided.

Lindenlaub, J. C.↗

A quantitative model for the potential resulting from reconnection with an arbitrary interplanetary magnetic field

A quantitative three-dimensional model is proposed for the electric potential arising from magnetopause reconnection, in which several approximations are made concerning configuration of the magnetosheath flow, limitations on the magnitude of the reconnection speed, and the geometry of the problem. These approximations are such that the model yields an upper limit for the potential. The magnitude of the polar cap ionospheric electric field computed from this model is larger than that measured on balloons by an average factor of about 3, and the model reproduces the temporal variations of the experimental data. It is concluded that magnetopause reconnection is a highly efficient process that is probably the dominant mechanism driving polar cap convection and supplying energy to the magnetosphere. It seems that the most efficient way for the solar wind to pass the magnetospheric obstacle is by magnetopause reconnection.

Gonzalez, W. D.↗

Quantitative density visualization in a transonic rotor

The flow in a two foot diameter transonic rotor has been visualized using a fluorescent gas, 2, 3 butanedione, as a tracer. The technique allows the three dimensional flow to be imaged as a set of distinct planes. Quantitative static density maps can be obtained after correcting the images for distortion and nonlinearities introduced by the illumination and imaging systems. The visualized flow is compared to data taken simultaneously by high frequency pressure transducers near the rotor entrance and exit planes.

Epstein, A. H.↗

A theoretical/experimental program to develop active optical pollution sensors: Quantitative remote Raman lidar measurements of pollutants from stationary sources

Typical pollutant gas concentrations at the stack exits of stationary sources can be estimated to be about 500 ppm under the present emission standards. Raman lidar has a number of advantages which makes it a valuable tool for remote measurements of these stack emissions. Tests of the Langley Research Center Raman lidar at a calibration tank indicate that night measurements of SO2 concentrations and stack opacity are possible. Accuracies of 10 percent are shown to be achievable from a distance of 300 m within 30 min integration times for 500 ppm SO2 at the stack exits. All possible interferences were examined quantitatively (except for the fluorescence of aerosols in actual stack emissions) and found to have negligible effect on the measurements. An early test at an instrumented stack is strongly recommended.

Poultney, S. K.↗

Quantitative determination of smoke and toxic product potential of materials with the AMINCO (registered) NBS smoke density chamber

Quantitative measurements of smoke obscuration produced by standard area samples under high energy pyrolysis both with and without an ignition source, using a collimated vertical light beam in conjunction with an ultra-linear photomultiplier microphotometer are obtainable with the smoke density chamber. Results are expressed in dimensionless specific optical density permitting usage calculations in accordance with a geometric relationship.

Greenberg, S.↗

Quantitative water quality with LANDSAT and Skylab

Correlation studies were completed between LANDSAT Multispectral Scanner (MSS) band ratios derived from computer compatible tape (CCT) and 170 water samples taken from three large Kansas reservoirs, coincident with 16 different LANDSAT passes over a 13 month period. The following conclusions were obtained: (1) LANDSAT MSS reflectance levels are useful for quantitative measurement of suspended solids up to at least 900 ppm, (2) MSS band ratios derived from CCT can measure suspended solids with 67% confidence level accuracy of 12 ppm over the range 0-80 ppm and 35 ppm over the range 0900 ppm, (3) suspended solids contour maps can be easily constructed from CCT for water bodies larger than approximately 100 acres, (4) rationing suppresses MSS reflectance level dependence on seasonal sun angle variation and permits measurement of suspended load the year round in the middle latitudes. SKYLAB imagery from a single pass over three reservoirs compares favorably to LANDSAT results up to 100 ppm.

Yarger, H. L.↗

An evaluation of recent quantitative magnetospheric magnetic field models

Magnetospheric field models involving dipole tilt effects are discussed, with particular reference to defined magnetopause models and boundary surface models. The models are compared with observations and with each other whenever possible. It is shown that models containing only contributions from magnetopause and tail current systems are capable of reproducing the observed quiet time field just in a qualitative way. The best quantitative agreement between models and observations take place when currents distributed in the inner magnetosphere are added to the magnetopause and tail current systems. One region in which all the models fall short is the region around the polar cusp. Obtaining physically reasonable gradients should have high priority in the development of future models.

Walker, R. J.↗

Quantitative measurement of surface contamination

Portable and highly sensitive system permits quantitative determinations on test surfaces. Device is used in normal room light and permits detection of significantly smaller samples. Digitation of output permits easy evaluation of contamination cleanup techniques.

Richmond, R. G.↗

Quantitative determination of zero-gravity effects on crystal growth from the melt (experiment MA-060)

The purpose of experiment MA-060 was to investigate quantitatively the effects of near-zero gravity conditions on crystal growth and dopant segregation during directional solidification from the melt. Gallium-doped germanium single crystals were successfully grown from the melt with simultaneous interface demarcation during the Apollo Soyuz Test Project mission. The analysis of the experimental data indicates striking differences of dopant segregation and growth behavior in the presence and absence of gravity. The results obtained are believed to have far-reaching implications on materials processing under zero-gravity conditions and on the theory of crystal growth and segregation in general.

Gatos, H. C.↗

Clinical applications of a quantitative analysis of regional lift ventricular wall motion

Observations were summarized which may have clinical application. These were obtained from a quantitative analysis of wall motion that was used to detect both hypokinesis and tardokinesis in left ventricular cineangiograms. The method was based on statistical comparisons with normal values for regional wall motion derived from the cineangiograms of patients who were found not to have heart disease.

Leighton, R. F.↗

Clinical application of a light-pen computer system for quantitative angiography

The important features in a clinical system for quantitative angiography were examined. The human interface for data input, whether an electrostatic pen, sonic pen, or light-pen must be engineered to optimize the quality of margin definition. The computer programs which the technician uses for data entry and computation of ventriculographic measurements must be convenient to use on a routine basis in a laboratory performing multiple studies per day. The method used for magnification correction must be continuously monitored.

Alderman, E. L.↗

Quantitative analysis of regional myocardial performance in coronary artery disease

Findings from a group of subjects with significant coronary artery stenosis are given. A group of controls determined by use of a quantitative method for the study of regional myocardial performance based on the frame-by-frame analysis of biplane left ventricular angiograms are presented. Particular emphasis was placed upon the analysis of wall motion in terms of normalized segment dimensions, timing and velocity of contraction. The results were compared with the method of subjective assessment used clinically.

Stewart, D. K.↗

Quantitative multielement analysis using high energy particle bombardment

Charged particles ranging in energy from 0.8 to 4.0 MeV are used to induce resonant nuclear reactions, Coulomb excitation (gamma-rays), and X-ray emission in both thick and thin targets. Quantitative analysis is possible for elements from Li to Pb in complex environmental samples, although the matrix can severely reduce the sensitivity. It is necessary to use a comparator technique for the gamma-rays while for X-rays an internal standard can be used. A USGS standard rock is analyzed for a total of 28 elements. Water samples can be analyzed either by nebulizing the sample doped with Cs or Y a thin Formvar film or by extracting the sample onto ion exchange resin which is pressed into a pellet.

Clark, P. J.↗

Survey of quantitative data on the solar energy and its spectra distribution

This paper presents a survey of available quantitative data on the total and spectral solar irradiance at ground level and outside the atmosphere. Measurements from research aircraft have resulted in the currently accepted NASA/ASTM standards of the solar constant and zero air mass solar spectral irradiance. The intrinsic variability of solar energy output and programs currently under way for more precise measurements from spacecraft are discussed. Instrumentation for solar measurements and their reference radiation scales are examined. Insolation data available from the records of weather stations are reviewed for their applicability to solar energy conversion. Two alternate methods of solarimetry are briefly discussed.

Thekaekara, M. P.↗