Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

USF/Russian dosimetry on STS-57

The major purpose of this experiment was to conduct an international comparison of passive dosimetry methods in space. Two APD's were flown in the charged particle directional spectrometer (CPDS)/tissue equivalent proportional counter (TEPC) locker on the space shuttle during the STS-57 mission. Due to placement, the shielding and radiation environment of the APD's were nearly the same and the dosimeters distributed in the two boxes can be considered equally exposed. The dosimeter types included plastic nuclear track detectors (PNTD's), thermoluminescent detectors (TLD), nuclear emulsions, and thermal/resonance neutron detectors (TRND's). The USF dosimeters included PNTD's, TLD's, and TRND's, while the Russian dosimeters included PNTD's, TLD's, and nuclear emulsions.

Source record↗

Radio and X-ray observations of the gamma-ray bright quasar PKS 0528+134

We present a study of the z = 2.07 quasar PKS 0528+134, which has been detected as an extraordinarily luminous gamma-ray source. Its radio properties are highly variable in both total and polarized flux density. Milliarcsecond-scale maps from global very long base interferometry (VLBI) experiments, an X-ray spectrum from ROSAT Position Sensitive Proportional Counter (PSPC) observations, and light curves in total flux density and polarization are used to investigate the geometry, radiation mechanism, and physical environment of the emission region in the source. The VLBI images reveal a bent jet extending toward the northeast on parsec scales, with less intense knots of emission appearing on the opposite side of the brightest spot. The position of the core usually found in such sources is unclear. The polarization angle is stable despite strong variability in polarized flux density and indicates that the magnetic field is aligned with the jet axis as defined by our 8.4 GHz image. The ROSAT X-ray flux density of PKS 0528+134 in 1991 March is measured to be 1.6 micro Jy at 1 keV, with a very steep spectral (`energy') index sigma(sub x) approximately equal to 2.2. The X-ray observations reveal the presence of cold gas along the line of sight significantly in excess of that present in the Galaxy. A strong radio flare began within two months of the first observation of a high flux of gamma-rays from PKS 0528+134 by Hunter et al. Using the geometry and spectral chacateristics determined by our VLBI observations, a synchrotron self-Compton calculation indicates that relativistic bulk motion is required in PKS 0528+134, with an estimated Doppler beaming factor delta approximately greater than 4.3, similar to the value delta approximately greater than 7 required to explain the low optical depth of the gamma-rays to photon-photon pair production. We suggest that the core activity of PKS 0528+134 is sporadic in nature, with the nonthermal outburst starting in 1991 representing a violent period involving ejection of relativistic plasma along a compact jet pointed almost directly toward us.

Zhang, Yun Fei↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

In Situ Aerosol-Size Distributions and Clear-Column Radiative Closure During ACE-2

As part of the second Aerosol Characterization Experiment (ACE-2) during June and July of 1997, aerosol-size distributions were measured on board the CIRPAS Pelican aircraft through the use of a Differential Mobility Analyzer (DMA) and 2 Optical Particle Counters (OPCs). During the campaign, the boundary-layer aerosol typically possessed characteristics representative of a background marine aerosol or a continentally influenced aerosol, while the free-tropospheric aerosol was characterized by the presence or absence of a Saharan dust layer. A range of radiative closure comparisons were made using the data obtained during vertical profiles flown on 4 missions. Of particular interest here are the comparisons made between the optical properties as determined through the use of measured aerosol-size distributions and those measured directly by an airborne 14-wavelength sunphotometer and 3 nephelometers. Variations in the relative humidity associated with each of the direct measurements required consideration of the hygroscopic properties of the aerosol for size-distribution-based calculations. Simultaneous comparison with such a wide range of directly-measured optical parameters not only offers evidence of the validity of the physicochemical description of the aerosol when closure is achieved, but also provides insight into potential sources of error when some or all of the comparisons result in disagreement. Agreement between the derived and directly-measured optical properties varied for different measurements and for different cases. Averaged over the 4 case studies, the derived extinction coefficient at 525 nm exceeded that measured by the sunphotometer by 2.5% in the clean boundary layer, but underestimated measurements by 13% during pollution events. For measurements within the free troposphere, the mean derived extinction coefficient was 3.3% and 17% less than that measured by the sunphotometer during dusty and non-dusty conditions, respectively. Likewise, averaged discrepancies between the derived and measured scattering coefficient were -9.6%, +4.7%, +17%, and -41% for measurements within the clean boundary layer, polluted boundary layer, free troposphere with a dust layer, and free troposphere without a dust layer, respectively. Each of these quantities, as well as the majority of the more than 100 individual comparisons from which they were averaged, were within estimated uncertainties.

Collins, R.↗

Microdosimeter Instrument (MIDN-II) for Personnel Dosimetry

This group of collaborators has been funded, by the National Space Biomedical Research Institute (NSBRI) and the U. S. National Aeronautics and Space Administration (NASA) as of February, 2009 to develop a prototypic dosimeter/microdosimeter instrument that measures in real time the radiation risk to personnel in a time varying radiation field of possibly unknown composition. The microdosimetric detectors will be solid-state devices more compact, more rugged than conventional microdosimetric proportional counters used previously in space and will consume less power. The proposed detector will be based on the heritage of the MIDN-MidSTAR microdosimeter launched on the MidSTAR spacecraft on March, 2007, the only solid-state microdosimeter ever flown in space. The system will be suitable for measurements in spacesuits, spacecrafts, remote rovers, or other dynamic or static environments. Measurements as a function of time will not only provide the instantaneous and average absorbed physical dose but also corresponding microdosimetric spectra, dose rates, the dose equivalents, and the dose equivalent rates. Values of the dose equivalents are used to establish relative risks for humans exposed to radiation and to determine regulatory limits. Because these parameters will be available to the astronauts and mission control in real time, these systems can be used not only to quantify exposures and limits, but also to allow appropriate actions to be taken to reduce radiation exposures and their consequences. Earlier prototypes have been used successfully to characterize beams of energetic protons and heavier ions including carbon, oxygen, silicon, titanium, and iron at the NASA Space Radiation Laboratory at Brookhaven National Laboratory. The initial design will be presented and discussed and spectra will be presented.

Pisacane, V. L.↗

Track Structure Model for Radial Distributions of Electron Spectra and Event Spectra from High-Energy Ions

An analytic method is described for evaluating the average radial electron spectrum and the radial and total frequency-event spectrum for high-energy ions. For high-energy ions, indirect events make important contributions to frequency-event spectra. The method used for evaluating indirect events is to fold the radial electron spectrum with measured frequency-event spectrum for photons or electrons. The contribution from direct events is treated using a spatially restricted linear energy transfer (LET). We find that high-energy heavy ions have a significantly reduced frequency-averaged final energy (yF) compared to LET, while relativistic protons have a significantly increased yF and dose-averaged lineal energy (yD) for typical site sizes used in tissue equivalent proportional counters. Such differences represent important factors in evaluating event spectra with laboratory beams, in space- flight, or in atmospheric radiation studies and in validation of radiation transport codes. The inadequacy of LET as descriptor because of deviations in values of physical quantities, such as track width, secondary electron spectrum, and yD for ions of identical LET is also discussed.

Cucinotta, F. A.↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARM Data for Examining the Ice-Nucleating Particles from SGP Part II (ExINP-SGP II) Aerodynamic Particle Sizer, Condensation Particle Counter, and Meteorological Instrument Data Analysis

Knowledge of airborne particulate matter (PM), especially the particles that have supermicron diameters, is key for understanding ice-nucleating particles (INPs). Supported by the Atmospheric Radiation Measurement (ARM) user facility, we sampled PM and surface soil materials at the Southern Great Plains observatory (SGP; 36° 36′ 18″ N, 97° 29′ 6″ W) to systematically compare the INP abundance and ice nucleation efficiency of different SGP samples (i.e., airborne versus surface materials). The field campaign, named Examing INP from SGP II (ExINP-SGP II), was conducted from 20 January to 20 April, 2021. Our data analysis products include (1) physical surface sorption characterization data (i.e., BET, pore volume) of two sets of samples -- SGP Soil and USDA, (2) X-ray diffraction spectra for the same two samples, (3) immersion freezing assay-based ice nucleation active mass density data as a function of freezing temperature for both ambient and surface samples, and (4) time-series data of ambient meteorological conditions, concentration particle counter-derived aerosol particle concentration, and aerosol particle sizer measurement during ExINP-SGP II.

54 ENVIRONMENTAL SCIENCES↗

System for Manipulating Drops and Bubbles Using Acoustic Radiation Pressure

The manipulation and control of drops of liquid and gas bubbles is achieved using high intensity acoustics in the form of and/or acoustic radiation pressure and acoustic streaming. generated by a controlled wave emission from a transducer. Acoustic radiation pressure is used to deploy or dispense drops into a liquid or a gas or bubbles into a liquid at zero or near zero velocity from the discharge end of a needle such as a syringe needle. Acoustic streaming is useful in manipulating the drop or bubble during or after deployment. Deployment and discharge is achieved by focusing the acoustic radiation pressure on the discharge end of the needle, and passing the acoustic waves through the fluid in the needle. through the needle will itself, or coaxially through the fluid medium surrounding the needle. Alternatively, the acoustic waves can be counter-deployed by focusing on the discharge end of the needle from a transducer axially aligned with the needle, but at a position opposite the needle, to prevent premature deployment of the drop or bubble. The acoustic radiation pressure can also be used for detecting the presence or absence of a drop or a bubble at the tip of a needle or for sensing various physical characteristics of the drop or bubble such as size or density.

Oeftering, Richard C.↗

Sulfuric Acid New Particle Formation Field Campaign Report

This campaign aimed to measure gaseous sulfuric acid concentrations at the surface level using a newly developed sulfuric acid dimethylamine-reactive condensation particle counter (SAD-RCPC). Sulfuric acid is a key nucleation precursor and is the likely driving compound for new particle formation at the Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory. The SAD-RCPC will be deployed in the future at ARM SGP (AFC010010: "Vertically Resolved Nucleation Precursors at SGP") scheduled for 2024. The campaign was in conjunction with Eleanor Browne's campaign (AFC010075: Boundary-layer gradients in new particle formation) and took place from 05/7/23 to 5/21/23. The measured sulfuric acid concentrations by the SAD-RCPC will be compared to concentrations measured by Browne's chemical ionization mass spectrometer (CIMS). The SAD-RCPC consisted of a glass flow reactor coupled to a 1-nm diethylene glycol condensation particle counter (DEG CPC). Sampled air was mixed with a high concentration of dimethylamine vapor (~1 ppbv). Sulfuric acid within the sampled gas nucleated with dimethylamine to form detectable 1-nm particles. The measured particle concentration was converted to sulfuric acid concentration using nucleation reaction kinetics. The pulse height distribution of particles detected by the DEG CPC was observed using a multi-channel analyzer. Large pre-existing particles were separated from the freshly formed particles in the SAD-RCPC from the pulse height distribution (PHD). During the short campaign, seven new particle formation events were observed. The SAD-RCPC detected an increase in sulfuric acid concentration, but this also coincided with an increase in pre-existing <3 nm particle concentrations. In addition, Browne's CIMS detect sulfuric acid concentrations in the range of 10 5 -10 6 cm -3 .

54 ENVIRONMENTAL SCIENCES↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce↗

High-energy gamma-ray astronomy

The subject of gamma-ray astronomy is discussed with emphasis on celestial gamma rays with energies in excess of 10 MeV. Early observations of such gamma rays are reviewed, a gamma-ray spark-chamber telescope is described together with a gas Cerenkov-counter telescope, and the gamma-ray sky is delineated. It is shown that the diffuse high-energy gamma radiation from the galactic plane probably results primarily from cosmic-ray interactions with interstellar matter. Mechanisms for gamma-ray production are identified, and it is noted that the general galactic radiation may prove to be of great value in studies of galactic structure. Possible sources are considered for the diffuse celestial radiation, and discrete sources are described, including the Crab pulsar, the Vela remnant, the Cygnus region, and Gould's Belt. Future developments in gamma-ray astronomy are considered.

Fichtel, C.↗

Dynamical Control of Broadband Coherent Absorption in ENZ Films

Interferometric effects between two counter-propagating beams incident on an optical system can lead to a coherent modulation of the absorption of the total electromagnetic radiation with 100% efficiency even in deeply subwavelength structures. Coherent perfect absorption (CPA) rises from a resonant solution of the scattering matrix and often requires engineered optical properties. For instance, thin film CPA benefits from complex nanostructures with suitable resonance, albeit at a loss of operational bandwidth. In this work, we theoretically and experimentally demonstrate a broadband CPA based on light-with-light modulation in epsilon-near-zero (ENZ) subwavelength films. We show that unpatterned ENZ films with different thicknesses exhibit broadband CPA with a near-unity maximum value located at the ENZ wavelength. By using Kerr optical nonlinearities, we dynamically tune the visibility and peak wavelength of the total energy modulation. Our results based on homogeneous thick ENZ media open a route towards on-chip devices that require efficient light absorption and dynamical tunability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The abundances and energy spectra of cosmic ray iron and nickel at energies from 1 to 10 GeV per amu

A scintillation-Cerenkov counter telescope has been used to measure the absolute flux and energy spectra of the nuclear components of the primary cosmic radiation. This instrument has been flown twice on high-altitude balloons launched from Muskogee, Okalahoma (vertical rigidity cutoff of 3.4 GV), and has provided a total exposure of 20 sq m sr hr. In this paper the measurements of the abundances and the differential energy spectra of iron and nickel in the energy interval from 1 to 10 GeV per amu are presented. The mean abundance of nickel relative to iron is found to be 0.050 + or - 0.003. This ratio is consistent with abundances at the source which are similar to those of the interstellar medium as estimated both by Meyer (1979) and by Cameron (1970). If the measured energy spectra are fit to single power laws in total energy, spectral indices of 2.44 + or - 0.07 for iron and 2.33 + or - 0.13 for nickel are obtained.

Minagawa, G.↗

Active dosimetric measurements on Shuttle flights

A tissue-equivalent proportional counter spectrometer capable of measuring the absorbed dose and dose distribution as a function of LET and time, for all penetrating radiation in space, is described. This instrument weighs about 0.7 kg and was flown on the STS-31 (28.5 deg x 620 km) flight of the Space Shuttle, 24-29 April 1990. The measured total dose is in excellent agreement with the calculations based on the AP8MAX model of the trapped radiation belt protons. The observed LET frequency distribution is also in excellent agreement with calculations based on this model. Active instruments can provide more detailed dosimetry for crew risk assessment than the thermoluminescent detectors or a plastic track detector system.

Badhwar, Gautam D.↗

The formation process of the He I lambda 10830 line in cool giant stars

The Final Report on the formation process of the He I lambda 10830 line in cool giant stars is presented. The research involves observing a sample of cool giant stars with ROSAT. These stars were selected from the list of bright stars which display He I lambda 10830 in absorption or emission and lie on the cool side of the coronal dividing line. With measured x ray fluxes or upper limits measured by the Position Sensitive Proportional Counter (PSPC), the role x rays play in the formation of this important line was investigated using the non-LTE radiative transfer code PANDORA. Hydrodynamic calculations were performed to investigate the contributions of acoustic wave heating in the formation of this line as well.

Luttermoser, Donald G.↗

NASA Tech Briefs, September 2011

Topics covered include: Fused Reality for Enhanced Flight Test Capabilities; Thermography to Inspect Insulation of Large Cryogenic Tanks; Crush Test Abuse Stand; Test Generator for MATLAB Simulations; Dynamic Monitoring of Cleanroom Fallout Using an Air Particle Counter; Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency; Positively Verifying Mating of Previously Unverifiable Flight Connectors; Radiation-Tolerant Intelligent Memory Stack - RTIMS; Ultra-Low-Dropout Linear Regulator; Excitation of a Parallel Plate Waveguide by an Array of Rectangular Waveguides; FPGA for Power Control of MSL Avionics; UAVSAR Active Electronically Scanned Array; Lockout/Tagout (LOTO) Simulator; Silicon Carbide Mounts for Fabry-Perot Interferometers; Measuring the In-Process Figure, Final Prescription, and System Alignment of Large; Optics and Segmented Mirrors Using Lidar Metrology; Fiber-Reinforced Reactive Nano-Epoxy Composites; Polymerization Initiated at the Sidewalls of Carbon Nanotubes; Metal-Matrix/Hollow-Ceramic-Sphere Composites; Piezoelectrically Enhanced Photocathodes; Iridium-Doped Ruthenium Oxide Catalyst for Oxygen Evolution; Improved Mo-Re VPS Alloys for High-Temperature Uses; Data Service Provider Cost Estimation Tool; Hybrid Power Management-Based Vehicle Architecture; Force Limit System; Levitated Duct Fan (LDF) Aircraft Auxiliary Generator; Compact, Two-Sided Structural Cold Plate Configuration; AN Fitting Reconditioning Tool; Active Response Gravity Offload System; Method and Apparatus for Forming Nanodroplets; Rapid Detection of the Varicella Zoster Virus in Saliva; Improved Devices for Collecting Sweat for Chemical Analysis; Phase-Controlled Magnetic Mirror for Wavefront Correction; and Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics.

Source record↗