Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measurements of the Jovian radiation belts

The University of California at San Diego trapped radiation detector measured proton and electron fluxes, angular distributions, and energy spectra throughout the Pioneer 10 fly by of Jupiter in December 1973. The instrumentation and calibrations are described, and good values for particle fluxes in the inner and outer regions are presented. The major features of the Jovian radiation belts are described, with preliminary discussions of their meanings.

Fillius, R. W.↗

Ultra-low-noise, high-impedance preamp for cryogenic detectors

A relatively simple room-temperature preamp design that satisfies both the low-noise and wideband requirements for the InSb Putley-mode detector and which is based on a common-drain JFET input, is presented. The design has an input capacitance of 28 pf which is much less than comparably noisy common-source amplifiers. It can be used for preamplification of 0.1 to 10 MHz signals from liquid-helium-cooled radiation detectors.

Brown, E. R.↗

The trapped radiation belts of Jupiter

The preliminary results from the Trapped Radiation Detector instruments of the University of California at San Diego aboard Pioneers 10 and 11 for making measurements in the Jupiter magnetosphere are reviewed. Attention is given to the instrument and the flyby trajectories and results of the following investigations are presented: interplanetary electrons of Jovian origin, the configuration of the magnetosphere, interactions between the trapped radiation belts and Jupiter's satellites, (absorption of trapped radiation, the effect of angular dimensions, and the injection of energetic radiation), the behavior of electrons in the inner Jupiter magnetosphere, and multiple peaks near Pioneer 11 periapsis.

Fillius, W.↗

The development of a high energy cosmic ray detector for Spacelab-2

A large cosmic ray detector aimed at measurements of the energy spectra and of the elemental abundances of cosmic ray nuclei at very high energies, up to several TeV/nucleon was constructed. The instrument is an electronic counter telescope with a geometric factor of 5 sq ster. It accomplishes measurements of the particle energies through the use of gas Cerenkov counters and of transition radiation detectors. The solutions of a number of technological problems that are encountered when developing such instrumentation for Shuttle missions are discussed.

Lheureux, J.↗

Parametric study of flame radiation characteristics of a tubular-can combustor

A series of combustor tests were conducted with a tubular-can combustor to study flame radiation characteristics and effects with parametric variations in combustor operating conditions. Two alternate combustor assemblies using a different fuel nozzle were compared. Spectral and total radiation detectors were positioned at three stations along the length of the combustor can. Data were obtained for a range of pressures from 0.34 to 2.07 MPa (50 to 300 psia), inlet temperatures from 533 to 700K (500 to 800 F), for Jet A (13.9 deg hydrogen) and ERBS (12.9% hydrogen) fuels, and with fuel-air ratios nominally from 0.008 to 0.021. Spectral radiation data, total radiant heat flux data, and liner temperature data are presented to illustrate the flame radiation characteristics and effects in the primary, secondary, and tertiary combustion zones.

Humenik, F. M.↗

The high energy cosmic ray detector for Spacelab II

A large cosmic ray detector to be flown on Spacelab II is presently under construction at the University of Chicago. The instrument, with a geometric factor of 5 sq m-ster, is designed to measure the elemental composition and the energy spectra of individual cosmic ray nuclei (Li to Fe) from 50 GeV/nucleon to several TeV/nucleon. Plastic scintillators are used for charge determination, and gas Cerenkov and transition radiation detectors for energy measurements. The instrument and its functions are described, and several test results that are important for an optimum design are discussed.

Lamport, J. E.↗

On the generation of delta-rays in detectors for high-energy cosmic-ray nuclei

A common problem in detectors for cosmic-ray nuclei is the generation of energetic knock-on electrons by an incident nucleus. These electrons may produce additional signals which can obscure the true nature of the signal from the nucleus itself. In this paper, Monte Carlo simulations of these effects are discussed in the University of Chicago CRNE instrument for Spacelab-2, and show that they do not impair the performance of the transition radiation detector as designed. Some qualitative properties of delta-ray effects are identified, which are of use to other experimenters in this field.

Swordy, S. P.↗

The energy spectrum of cosmic ray electrons between 9 and 300 GeV

The high-energy cosmic-ray electron spectrum between 9 and 300 GeV has been measured using an instrument consisting of a combination of a transition-radiation detector and a shower detector. The instrument has been calibrated at accelerators over the energy range 5-300 GeV and has been exposed in a balloon flight for 9.3 sq m sr hr. The design of the instrument and the data analysis procedures are described. It is found that the electron spectrum is significantly steeper than the proton spectrum. If the spectrum is fitted to a single power law, a spectral index of 3.35 is obtained. This suggests the influence of radiative energy losses on galactic electrons at low energies. The results are interpreted in the context of the homogeneous model for galactic cosmic rays.

Prince, T. A.↗

Skeletal and body composition evaluation

Research on radiation detectors for absorptiometry; analysis of errors affective single photon absorptiometry and development of instrumentation; analysis of errors affecting dual photon absorptiometry and development of instrumentation; comparison of skeletal measurements with other techniques; cooperation with NASA projects for skeletal evaluation in spaceflight (Experiment MO-78) and in laboratory studies with immobilized animals; studies of postmenopausal osteoporosis; organization of scientific meetings and workshops on absorptiometric measurement; and development of instrumentation for measurement of fluid shifts in the human body were performed. Instrumentation was developed that allows accurate and precise (2% error) measurements of mineral content in compact and trabecular bone and of the total skeleton. Instrumentation was also developed to measure fluid shifts in the extremities. Radiation exposure with those procedures is low (2-10 MREM). One hundred seventy three technical reports and one hundred and four published papers of studies from the University of Wisconsin Bone Mineral Lab are listed.

Mazess, R. B.↗

Effect of Space Radiation on TES Detectors Performance

The Athena mission and its X-IFU instrument (X-ray Integral Field Unit) will be positioned at the Sun-Earth Lagrangian point L1, where it will be subject to solar wind (low flux plasma of 95% protons and 5% alpha particles) with energy below 0.1 MeV, and to galactic cosmic rays and solar flares (energetic protons, alpha particles, and electrons) with energies up to hundreds of MeV for protons and the GeV for heavier ions. Some of these particles will go through the satellite and hit the focal plane assembly and hence the detectors. These detectors will be TES (Transition-edge sensor) microcalorimeters, flown for the first time in such an environment. In order to ensure the performance of this type of detectors throughout the duration of such mission, it is critical to study the impact of the radiation on their behavior. Indeed, although a lot of reference material exist for semiconductor detectors such as CCDs, little is currently known about the impact of radiation on TES detectors. These energetic events could cause local heating or damage to the detectors and affect their performance. In this work, we describe how we designed a test campaign to assess the impact of L1 radiation on TES detectors for Athena/X-IFU-like missions and present the results of the tests. Analyses includes assessing changes in the pulse shapes and energy resolution of the detectors measured at 55 mK after several radiation dose steps performed at 4 K.

Sophie Beaumont↗

Infrared response measurements on radiation-damaged Si/Li/ detectors.

The improved infrared response (IRR) technique has been used to qualitatively compare radiation effects on Si(Li) detectors with energy levels reported for silicon in the literature. Measurements have been made on five commercial silicon detectors and one fabricated in-house, both before and after irradiation with fast neutrons, 1.9-MeV protons, and 1.6-MeV electrons. Effects dependent upon the extent of radiation damage have been observed. It seems likely that the photo-EMF, or photo-voltage, effect is the basic mechanism for the observation of IRR in p-i-n diodes with a wide i-region. Experimental characteristics of the IRR measurement are in agreement with those of the photovoltage effect.

Sher, A. H.↗

Mobility Monitoring System For Ecological Studies

Radioactive-nuclide system automatically monitors animals in the field, using radioactive tracers affixed to the animals, Geiger-Muller tube radiation detectors, and event-recorders. Four animals can be monitored simultaneously within a 32-m circle, with each animal as far as 1 m from its associated detector.

Eisler, W. J., Jr.↗