Raman-shifting an ArF excimer laser to generate new lines for obtaining optical diagnostic based information in flow fields

The application of tunable excimer lasers in combustion and flow diagnostics is almost routine nowadays. The properties of this laser system that enable density and temperature measurements in supersonic and hypersonic flow fields to be conducted are its high power, high repetition rate, and high spectral brightness. The limitation imposed by this system on these measurements is the paucity of lines in the wavelength region, the vacuum-ultraviolet, where species of interest, such as OH, N2, O2, H2, H2O, CO, NO, etc., are susceptible to electronic excitation to high-lying states. To circumvent this problem one normally resorts to nonlinear optical techniques such as frequency conversion via stimulated Raman scattering (SRS), more commonly known as Raman shifting or Raman mixing, to extend these nonintrusive and nonperturbing techniques to the shorter wavelengths in the VUV region and, for that matter, to longer wavelengths in the infrared region, if the need arises. The theoretical basis of SRS and its application are well documented in the literature. In essence, the Raman shift is a consequence of the inelastic scattering of the incident radiation by the sample. Most of the scattered radiation from the molecules of the sample is unchanged in frequency. However, a small fraction of the incident radiation is changed in frequency. This shift is a result of the fact that some of the incident photons on colliding with the molecules of the sample give up some of their energy and emerge with a lower energy resulting in the lower-frequency Stokes radiation. Other incident photons may increase their energy by colliding with the vibrationally excited molecules of the medium and emerge as higher-frequency antistokes radiation. The generation of the latter is the main objective of this project. The process, however, depends on several factors, including the beam quality of the pump laser, the cross-section of the gaseous medium, the gas pressure, and the ambient temperature of the gas near the focal region. Furthermore, since the Raman shifting process is polarization sensitive, it is necessary to have all of the laser energy in a single polarization. These factors were taken into consideration in the execution of the project. The implementation of the Raman shift was accomplished by focusing the 193 nm output of an ArF excimer laser (Lamda-Physik LPX 150) into a 1-meter long high pressure recirculating Raman cell filled with H2 gas. The laser system was modified in order to improve the mode quality of the pump beam to enhance the Raman shifting. To accomplish this feat, a prism beam expander and grating on the oscillator discharge provided wavelength tuning over the excimer gain profile. Furthermore, a triple-pass configuration, as opposed to unstable resonator optics, was employed in the operation of the amplifier cavity so that when the oscillator output radiation, focused by a 51-cm focal length fused silica lens through a 50 micron pinhole (serving as a spatial filter) and recollimated with a 25-cm focal length lens, was fed into the amplifier, it was injection locked, thereby providing tunable radiation with relatively low divergence. The forward scattered radiation emanating from the impingement of the modified pump beam on the Raman cell was detected using an energy meter after the latter had been separated from it using a dispersing prism.

Koker, Edmond B.↗

Femtosecond resolution of soft mode dynamics in structural phase transitions

The microscopic pathway along which ions or molecules in a crystal move during structural phase transition can often be described in terms of a collective vibrational mode of the lattice. In many cases, this mode, called a 'soft' phonon mode because of its characteristically low frequency near the phase transition temperature, is difficult to characterize through conventional frequency-domain spectroscopies such as light or neutron scattering. A femtosecond time-domain analog of light-scattering spectroscopy called impulsive stimulated Raman scattering (ISRS) has been used to examine the soft modes of two perovskite ferroelectric crystals. The low-frequency lattice dynamics of KNbO3 and BaTiO3 are clarified in a manner that permits critical evaluation of microscopic models for their ferroelectric transitions. The results illustrate the advantages of ISRS over conventional Raman spectroscopy of low-frequency, heavily damped soft modes.

Dougherty, Thomas P.↗

Coherent Raman amplification.

Coherent Raman amplification dynamics, considering pump depletion and coupling saturation and stimulated Raman scattering by polarization waves

POLARIZATION CHARACTERISTICS↗

New Examination of the Traditional Raman Lidar Technique II: Evaluating the Ratios for Water Vapor and Aerosols

In a companion paper, the temperature dependence of Raman scattering and its influence on the Raman and Rayleigh-Mie lidar equations was examined. New forms of the lidar equation were developed to account for this temperature sensitivity. Here those results are used to derive the temperature dependent forms of the equations for the water vapor mixing ratio, aerosol scattering ratio, aerosol backscatter coefficient, and extinction to backscatter ratio (Sa). The error equations are developed, the influence of differential transmission is studied and different laser sources are considered in the analysis. The results indicate that the temperature functions become significant when using narrowband detection. Errors of 5% and more can be introduced in the water vapor mixing ratio calculation at high altitudes and errors larger than 10% are possible for calculations of aerosol scattering ratio and thus aerosol backscatter coefficient and extinction to backscatter ratio.

Whiteman, David N.↗

Remote monitoring of the atmosphere with Raman LIDAR

Some of the Raman LIDAR applications for monitoring the atmosphere are reviewed. Following a definition of Raman scattering, the basic design of a Raman LIDAR system is described and the atmosphere-monitoring potentialities and limitations of the system are discussed, along with the possibilities of further progress.

Melfi, S. H.↗

Standard methods for analysis and interpretation of Lidar data for environmental monitoring

Lidar is similar in principle to microwave radar but uses a pulsed laser as the source and an optical telescope as the receiver. Lidar observations of elastic scattering from aerosols and more recently Raman scattering from molecules have been performed in the atmosphere with favorable results. A description of the Lidar technique is provided. Lidar measurements of remote visibility are discussed together with the measurement of remote visibility and the determination of molecular concentrations.

Melfi, S. H.↗

Single-pulse broad-band rotational CARS thermometry of cold N2 gas

Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.

Chang, R. K.↗

Inelastic scattering in planetary atmospheres. I - The Ring effect, without aerosols

The contribution of inelastic molecular scattering (Rayleigh-Brillouin and rotational Raman scattering) to the filling-in of Fraunhofer lines in the light of the blue sky is studied. Aerosol fluorescence is shown to be negligible, and aerosol scattering is ignored. The angular and polarization dependences of the filling-in detail for single scattering are discussed. An approximate treatment of multiple scattering, using a backward Monte Carlo technique, makes it possible to investigate the effects of the ground albedo. As the molecular scatterings alone produce more line-filling than is observed, it seems likely that aerosols dilute the effect by contributing unaltered sunlight to the observed spectra.

Kattawar, G. W.↗

Rotational CARS application to simultaneous and multiple-point temperature and concentration determination in a turbulent flow

Coherent anti-Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 is employed to measure the instantaneous (approximately 10 ns) rotational temperature of N2 gas at room temperature and below with good spatial resolution (0.2 x 0.2 x 3.0 cu mm). A broad bandwidth dye laser is used to obtain the entire rotational spectrum from a single laser pulse; the CARS signal is then dispersed by a spectrograph and recorded on an optical multichannel analyzer. A best fit temperature is found in several seconds with the aid of a computer for each experimental spectrum by a least squares comparison with calculated spectra. The model used to calculate the theoretical spectra incorporates the temperature and pressure dependence of the pressure-broadened rotational Raman lines, includes the nonresonant background susceptibility, and assumes that the pump laser has a finite linewidth. Temperatures are fit to experimental spectra recorded over the temperature range of 135 to 296 K, and over the pressure range of .13 to 15.3 atm.

Snow, J. B.↗

Rotational cars application to simultaneous and multiple-point temperature and concentration determination in a turbulent flow

Coherent Anti-stokes Raman Scattering (CARS) from the pure rotational Raman lines of N2 is employed to measure the instantaneous rotational temperature of N2 gas at room temperature and below with good spatial resolution. A broad-bandwidth dye laser is used to obtain the entire rotational spectrum from a signal laser pulse; the CARS signal is then dispersed by a spectrograph and recorded on an optical multichannel analyzer. A best-fit temperature is found in several seconds with the aid of a computer for each experimental spectrum by a least squares comparison with calculated spectra. The model used to calculate the theoretical spectra incorporates the temperature and pressure dependence of the pressure-broadened rotational Raman lines, includes the nonresonant background susceptibility, and assumes that the pump laser has a finite linewidth. Temperatures are fit to experimental spectra recorded over the temperature range of 135 to 296K, and over the pressure range of 0.13 to 15.3 atm. In addition to the spatially resolved single point work, we have used multipoint CARS to obtain information from many spatially resolved volume elements along a cylindrical line (0.1 x 0.1 x 2.0 mm). We also obtained qualitative information on the instantaneous species concentration and temperature at 20 spatially resolved volume elements (0.1 x 0.1 x 0.1 mm) along a line.

Snow, J. B.↗

Relative cross section and depolarization of NOCl

A standard photon counting technique and an argon-ion laser with 4545, 4579, 4727, 4765, 4880, 4965, 5017 and 5145-A lasing lines, providing a measurable Raman spectrum from NOCl, were used in the measurement of the Raman scattering cross section of NOCl at a Raman shift of 334.4 plus or minus 1.6/cm in relation to the N2 Raman cross section. A polarization analyzer and a quartz wedge were placed in front of the entrance slit of the double monochromator for depolarization measurements. Diagrams are plotted to show the scattering cross section and depolarization measurement results.

Hoell, J. M.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48 cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Raman Scattering↗

Optical Measurement and Visualization in High-Pressure, High-Temperature, Aviation Gas Turbine Combustors

Planar laser-induced fluorescence (PLIF), planar Mie scattering (PMie), and linear (1-D) spontaneous Raman scattering are applied to flame tube and sector combustors that burn Jet-A fuel at a range of inlet temperatures and pressures that simulate conditions expected in future high-performance civilian gas turbine engines. Chemiluminescence arising from C2 in the flame was also imaged. Flame spectral emissions measurements were obtained using a scanning spectrometer. Several different advanced concept fuel injectors were examined. First-ever PLIF and chemiluminescence data are presented from the 60-atm Gas turbine combustor facility.

Hicks, Yolanda R.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

IR camera Measurments↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part 1

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

Raman Scattering↗

Development of a fs/Ps CARS System for Temperature Measurements Within Supersonic and Hypersonic Environments

A hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system was developed for quantitative measurements of temperature in a laboratory-scale supersonic jet facility. Measurements were recorded at low pressures and densities relevant for supersonic and hypersonic environments, with special interest in exploring the feasibility of deploying this technique in the 20-inch Mach 6 and 31-inch Mach 10 wind tunnels located at NASA Langley Research Center. Modifications to the existing supersonic jet facility were made to simulate a test section with a width of 31 inches, so that the size of the test section is relevant for either wind tunnel. The CARS system was designed such that a similar beam geometry can be used in the laboratory to acquire point-based fs/ps CARS measurements along two axes of translation. Rotational Raman transitions of O 2 and N 2 were targeted.

CARS↗

Development of a fs/ps CARS System for Temperature Measurements in Supersonic and Hypersonic Environments

A hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system was developed for quantitative measurements of temperature in a laboratory-scale supersonic jet facility. Measurements were recorded at low pressures and densities relevant for supersonic and hypersonic environments, with special interest in exploring the feasibility of deploying this technique in the 20-inch Mach 6 and 31-inch Mach 10 wind tunnels located at NASA Langley Research Center. Modifications to the existing supersonic jet facility were made to simulate a test section with a width of 31 inches, so that the size of the test section is relevant for either wind tunnel. The CARS system was designed such that a similar beam geometry can be used in the laboratory to acquire point-based fs/ps CARS measurements along two axes of translation. Rotational Raman transitions of O 2 and N 2 were targeted.

CARS↗