Search NASASearch

SEARCH · Search NASA

Results for “RESEARCH AND TEST REACTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,216 records · Page 11

Project Development of an Electrochemical Denitration and Caustic Generation System for HLW Pretreatment at Hanford - 26350

An engineering-scale electrochemical processing skid is proposed to perform the denitration of Hanford tank waste, which would help to mitigate a key process concern with the direct feed processing of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The reduction of nitrates and organic compounds in the waste feed will directly reduce hazardous NOx and ammonia gases generated during the vitrification process, which in turn will aid in addressing potential regulatory and safety challenges associated with processing large volumes of tank waste. This paper highlights the past legacy work, project layout, accomplishments from Phase 1 and research and development envisioned for Phase 2. An innovative electrochemical denitration and caustic generation (EDCGe) process was demonstrated for the pretreatment of tank waste at the Savannah River Site (SRS) in the early 2000s. The denitration electrolyzer, off-gas abatement system, and caustic generator electrolyzer are being developed with the intent that the denitration electrolyzer will convert nitrate and nitrite anions to nitrogen gas while also yielding other gaseous byproducts, which may include N2O, NH3, VOCs, and H2. The gaseous byproducts will be managed via a tandem off-gas catalyst-bed treatment system. The caustic generation electrolyzer will recycle NaOH from the feed to produce a clean caustic stream for use within the batching tanks at Hanford, aiding in the preparation of waste for WTP. The reduction in hazardous emissions and improved waste treatment processes provides a robust solution for nuclear waste management, contributing to environmental safety and regulatory compliance. The EDCGe technology is being adapted, modified, and updated for the preparation of the Direct Feed-High Level Waste (DF-HLW) flowsheet at Hanford. Phase 1 demonstrated a bench-scale proof-of-concept for reactions involving the denitration electrolyzer and gas phase abatement of ammonia. The electrochemical technology is drawing on the scientific outcomes that were reported in the legacy work. The results from Phase 1 demonstrated the viability of the EDCGe system in reducing the nitrogen species of simple non-radioactive waste simulants. Commercially available alloys used as electrode materials and membranes are being studied for the denitration and caustic generation electrolyzers. The continuation of this project holds promise for broader applications, such as energy-efficient ammonia production, and contributes significant advancements in nuclear waste management. Additional material discovery has been investigated into ceramic Na super ion conductive (NaSICON) materials and off-gas abatement catalyst discovery. NaSICON is of interest for selective transport of Na within the electrolyzers to make a clean caustic stream. Future integration and optimization efforts, informed by Phase 1 results and ongoing research, will continue to drive advancements in nuclear waste management technology. The technology developed for the EDCGe treatment of tank waste will also have broader potential to inform other fields, such as energy-efficient ammonia production, as well as ammonia abatement catalysis through the lessons learned in electrochemical nitrate reduction. The applications and benefits of this research extend beyond Hanford and the Savannah River Site, supported by a collaborative team of scientists and engineers from national labs, academia, and industry, ensuring a comprehensive approach to solving complex waste treatment challenges. The team is leveraging advanced electrochemical technologies, machine learning, novel catalysts tailored for gaseous nitrogen species, and cutting-edge reactor systems to enhance the process efficiency and effectiveness of the denitration process.

Rodene, Dylan [Savannah River National Laboratory

PACT Center: Perovskite PV Accelerator for Commercializing Technologies (Final Technical Report)

The Perovskite PV Accelerator for Commercializing Technologies (PACT) center was established in July 2021 as a national resource to accelerate the commercialization of perovskite photovoltaic (PV) technology in the United States. Since its inception, PACT has been led by Sandia National Laboratories (Sandia) in partnership with the National Laboratory of the Rockies (NLR), formerly known as NREL. From FY20-FY23, Los Alamos National Laboratory (LANL), CFV Labs, Black & Veatch (B&V), and the Electric Power Research Institute (EPRI) were part of the project team. LANL brought expertise in perovskite PV device designs and processing, CFV Labs (now GroundWork Renewables) provided initial indoor and outdoor measurement hardware technology, B&V led the initial effort on perovskite PV bankability, and EPRI worked on reviewing testing standards, identifying commercialization gaps, and helping to run PACT’s Industry Advisory Board, a group including representatives from commercial testing labs, independent engineering firms, insurance companies, state regulators, and electric utilities. To source perovskite PV module samples, PACT contracted with the University of North Carolina (UNC), the University of Toledo, the University of Washington, and SLAC/Stanford University to provide a steady stream of research-grade perovskite mini modules, enabling protocol development in advance of commercial module availability. The project period ran from July 1, 2021, through December 31, 2025, including a No Cost Extension. Starting in FY25, the project was continued as a Core Capability in the Lab Call portfolio and continues at a reduced budget with only Sandia and NLR as funded recipients. Notably, starting in FY25 PACT expanded its scope beyond MHP modules to accept all emerging PV mini module technologies for testing, including organic PV (OPV) and all-thin-film tandems, with the aim of supporting commercialization across the broader emerging PV ecosystem. With this change in scope the program was renamed the PV Accelerator for Commercializing Technologies, dropping perovskite from the name.

14 SOLAR ENERGY

A parametric study of slow dynamic nonlinear elasticity with comparisons to models

Several phenomenological models that aspire to quantitative description of anomalous nonlinear mesoscopic elasticity are reviewed and compared with laboratory measurements. This class of nonlinearity, best known perhaps for slow dynamics and aging, is seen widely in imperfectly consolidated granular solids but is not well understood. Typical slow dynamic tests show that a modest conditioning oscillatory "pump" strain depresses material stiffness, which then recovers like the logarithm of time after conditioning ceases. Several phenomenological models based on physical arguments have been proposed that predict the material stiffness response to arbitrary pump strain histories during conditioning and recovery. Approximate closed form and numerical solutions to the models are presented that predict the quantitative influence of three key pump parameters: the pump's strain amplitude, the pump's strain rate, and the pump’s duration. Laboratory measurements on Berea sandstone, concrete and a confined single aluminum bead find that slow dynamic responses are linear in pump strain and independent of pump frequency. Measurements also show that, after pump-off, stiffness recovers over times far longer than the pump duration. These observations and others are compared to model predictions. One of the considered models, based on a picture of fast brittle damage and slow healing, successfully matches all these behaviors.

36 MATERIALS SCIENCE

Strong gradient neoclassical transport in the plateau regime

Strong gradient regions in tokamaks such as the pedestal or internal transport barriers are regions of reduced turbulence where neoclassical transport can play a dominant role. In pedestals, gradient lengths comparable to the ion poloidal gyroradius have been measured. Standard neoclassical theory can miss important strong gradient effects in these regions because it assumes that the gradient length scales of density, temperature and potential are larger than the ion poloidal gyroradius. We extend plateau regime neoclassical theory into regions of gradients of the order of the ion poloidal gyroradius to capture strong gradient effects on transport processes in the pedestal and internal transport barriers. The fundamental idea behind our new framework is to keep a scale separation between the orbit widths and the gradient length scales by performing a large aspect ratio expansion. In the plateau regime, strong gradients cause poloidal variation that is in–out as well as up–down asymmetric. We study two different test cases assuming either radial force balance or the absence of turbulence and show that strong gradient effects can enhance or reduce standard neoclassical theory predictions in the plateau regime in strong gradient regions.

fusion plasma

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab

Quantifying Primary Arc-Induced Degradation of Perovskite Solar Cells

Primary arcing induced by spacecraft charging presents a significant hazard to thin film solar cells if left unchecked. Here, we present the results of a preliminary effort to quantify the impacts of primary arcing to perovskite solar cells. Solar cells operating in a charged environment are susceptible to electrostatic discharges known as arcing. While primary arcs are not generally considered a major concern for traditional space PV, for thin film cells, these can induce significant heating and subsequent damage. We conducted ESD testing in a LEO-like plasma in the National Plasma Interaction Facility at NASA Glenn Research Center to quantify impacts to cell performance by arcing. The perovskites tested saw a decrease of short circuit current with an increased number of arcs, averaging a relative change of 73.89 ± 15.90% after 60 total arcs supplied a cumulative energy dose of 76.12 mJ to the string. Ongoing work entails testing with larger perovskite data sets and expanding to include additional thin film cell technologies to demonstrate the risk unmitigated primary arcing presents.

primary arcing

Adventures in Research: A History of Ames Research Center, 1940-1965

The present document, which I have called a history-though it certainly was not written for historians-was prepared for and at the request of the NASA Ames Research Center which, in sponsoring the project, acted with the encouragement of NASA Headquarters. It is an account of the establishment, evolutionary development, and activities of the Ames Research Center covering a period characterized by unprecedented scientific and technological revolution. The writing of this book about the Ames Research Center was undertaken with considerable pleasure by one who for many years was employed by the Center’s parent organization NASA and, before that, NACA; who had closely followed the Center’s growth from the beginning; and who was personally acquainted with, and who held in some affection, the members of its founding staff. These facts are given to alert readers to the presence of bias and the inaccuracies stemming therefrom. It should be emphasized that this work is a history only of the Ames Research Center. It is not a history of the U.S. Government, of NACA or NASA, of other research centers, of the military services, of industry, or of world events. Information on these peripheral subjects is introduced merely to provide the reader with a generalized feeling for the local and world environment in which the formation and subsequent activities of the Ames Research Center took place. The background material provided is notably incomplete and in some instances reveals the bias of the NACA/NASA community at the time the events took place. Frequently, also, it reflects the personalized viewpoint of the author who was a close observer of many of these events.

NASA Center History Series

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model