Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Time-Resolved Measurements in Optoelectronic Microbioanalysis

A report presents discussion of time-resolved measurements in optoelectronic microbioanalysis. Proposed microbioanalytical laboratory-on-a-chip devices for detection of microbes and toxic chemicals would include optoelectronic sensors and associated electronic circuits that would look for fluorescence or phosphorescence signatures of multiple hazardous biomolecules in order to detect which ones were present in a given situation. The emphasis in the instant report is on gating an active-pixel sensor in the time domain, instead of filtering light in the wavelength domain, to prevent the sensor from responding to a laser pulse used to excite fluorescence or phosphorescence while enabling the sensor to respond to the decaying fluorescence or phosphorescence signal that follows the laser pulse. The active-pixel sensor would be turned on after the laser pulse and would be used to either integrate the fluorescence or phosphorescence signal over several lifetimes and many excitation pulses or else take time-resolved measurements of the fluorescence or phosphorescence. The report also discusses issues of multiplexing and of using time-resolved measurements of fluorophores with known different fluorescence lifetimes to distinguish among them.

Bearman, Gregory↗

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

Near Real Time Prospecting for Lunar Volatiles: Demonstrating RESOLVE Science in the Field

The Regolith and Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) project aims to demonstrate the utility of "in situ resource utilization". In situ resource utilization (ISRU) is a way to rebalance the economics of spaceflight by reducing or eliminating materials that must be brought up from Earth and placed on the surface of the Moon for human use. RESOLVE is developing a rover-borne payload that (1) can locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. Such investigations are important not only for ISRU but are also critically important for understanding the scientific nature of these intriguing lunar polar volatile deposits. Temperature models and orbital data suggest near surface volatile concentrations may exist at briefly lit lunar polar locations outside persistently shadowed regions. A lunar rover could be remotely operated at some of these locations for the 4-7 days of expected sunlight at relatively low cost. In July 2012 the RESOLVE project conducted a full-scale field demonstration. In particular, the ability to perform the real-time measurement analysis necessary to search for volatiles and the ability to combine the various measurement techniques to meet the mission measurement and science goals. With help from the Pacific International Space Center for Exploration Systems (PISCES), a lunar rover prototype (provided by the Canadian Space Agency) was equipped with prospecting instruments (neutron spectrometer and near-infrared spectrometer), subsurface access and sampling tools, including both an auger and coring drill (provided by CSA) and subsurface sample analysis instrumentation, including a sample oven system, the Oxygen and Volatile Extraction Node (OVEN), and Gas Chromatograph / Mass Spectrometer system, the Lunar Advanced Volatile Analysis (LAVA) system. Given the relatively short time period this lunar mission is being designed to, prospecting needs to occur in near real-time. The two prospecting instruments are the neutron and NIR spectrometers. In the field demo a small radioactive source was provided the neutron flux. The NIR spectrometer, which includes its own light source, looks at surface reflectance for signatures of bound H20/0H and general mineralogy. Once a "hot spot" was found by the prospecting instruments, the drill could either auger or core. The auger drill worked to a depth of 50 cm and is monitored with a drill camera and the NIR spectrometer. As cuttings are brought up the NIR spectra is monitored. If a particular location is considered of high -interest then the decision to core could be made. The coring drill (a push-tube) allowed a meter sample to be acquired processed by the OVEN/LAVA sys-tem. This presentation will provide details as how these instruments worked together and how and if the planned measurements and science was obtained.

Elphic, Richard↗

Spatially Resolved Temperature and Water Vapor Concentration Distributions in Supersonic Combustion Facilities by TDLAT

Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. More than 2500 separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Due to the UVaSCF s unique electrical heating and ability for vitiate addition, measurements collected at the UVaSCF are presented as a calibration of the technique. Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Tomographic temperature and water vapor concentration distributions are presented from experimentation on the UVaSCF operating at a high temperature non-reacting case for water vitiation level of 12%. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are also presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

Busa, K. M.↗

Regolith Volatile Characterization (RVC) in RESOLVE

Resource investigation in the lunar poles is of importance to the potential impact of in-situ resource utilization (ISRU). The RESOLVE project developed a payload to investigate the permanently shadowed areas of the lunar poles and demonstrate ISRU technology. As a part of the RESOLVE project, the regolith volatile characterization (RVC) subsystem was designed to examine the release of volatiles from sample cores. The test sample was heated in the reactor to release the volatiles where they were analyzed with gas chromatography. Subsequently, the volatile sample was introduced into the lunar water resource demonstration (LWRD) subsystem where the released hydrogen and water were selectively captured. The objective of the Regolith Volatile Characterization (RVC) subsystem was to heat the crushed core sample and determine the desorption of volatile species of interest. The RVC subsystem encompasses the reactor and the system for volatile analysis. The system was designed to analyze H2, He, CO, CO2, N2, 02, CH4, H2S and H2O. The GC chosen for this work is a Siemens MicroSAM process GC with 3 columns and 8 TCD detectors. Neon was chosen as the carrier gas to enhance the analysis of hydrogen and helium.The limit of detection for the gases is approx.1000ppm for H2, CO. CO2 , N2, O2 and H2 S. The limit of detection for CH4 is approx.4000ppm and the water limit of detection is -10000 ppm with a sample analysis time of 2-3 minutes. These values (with the exception of water and H2S) were determined by dilution of a six gas mixture from Scott Gas (5% CO2, CO, O2, N2, 4% CH4 and H2) using mass flow controllers (MFC5). Water was calibrated at low levels using an in house relative humidity (RH) generator. H 2S and high concentrations of H2 were calibrated by diluting a pure stream of gas with MFCs. Higher concentrations of N2 and 02 were calibrated using Air again diluting with MFCs. There were three modification goals for the GC in EBU2 that would allow this process GC to be used in the field demo for RESOLVE. The first modification was to decrease the weight associated with the GC, this included eliminating the explosion proof case (Figure 1) and replacing it with a lightweight case as well as using an on board COPV tank for the neon carrier gas. The next goal was to add a second oven for the molecular sieve column to allow for dual temperature control during GC operation; the separation of hydrogen and helium is optimum at lower temperatures while the water analysis required higher temperatures creating a competing design requirement. The second oven also allows a lower limit of detection for water quantification and avoids the possibility of water condensing in the GC which could ruin the column characteristics. The final goal was to modify the column arrangement to optimize the system for our specific application. Figure 2 shows the internal details of the module optimized optimized for our field application. The modifications and performance of the gas analysis system will be discussed in detail.

Captain, Janine↗

Estimation of Daily PM(sub 10) Concentrations in Italy (2006-2012) Using Finely Resolved Satellite Data, Land Use Variables and Meteorology

Health effects of air pollution, especially particulate matter (PM), have been widely investigated. However, most of the studies rely on few monitors located in urban areas for short-term assessments, or land use/dispersion modelling for long-term evaluations, again mostly in cities. Recently, the availability of finely resolved satellite data provides an opportunity to estimate daily concentrations of air pollutants over wide spatio-temporal domains. Italy lacks a robust and validated high resolution spatio-temporally resolved model of particulate matter. The complex topography and the air mixture from both natural and anthropogenic sources are great challenges difficult to be addressed. We combined finely resolved data on Aerosol Optical Depth (AOD) from the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm, ground-level PM10measurements, land-use variables and meteorological parameters into a four-stage mixed model framework to derive estimates of daily PM10concentrations at 1-km2 grid over Italy, for the years 2006-2012. We checked performance of our models by applying 10-fold cross-validation (CV) for each year. Our models displayed good fitting, with mean CV-R2=0.65 and little bias (average slope of predicted VS observed PM10=0.99). Out-of-sample predictions were more accurate in Northern Italy (Po valley) and large conurbations (e.g. Rome), for background monitoring stations, and in the winter season. Resulting concentration maps showed highest average PM10levels in specific areas (Po river valley, main industrial and metropolitan areas) with decreasing trends over time. Our daily predictions of PM10concentrations across the whole Italy will allow, for the first time, estimation of long-term and short-term effects of air pollution nationwide, even in areas lacking monitoring data. Copyright © 2016 Elsevier Ltd. All rights reserved.

Particulate Matter/analysis↗

Spectrally Resolved Synthetic Aperture Imaging Interferometer: Final Report of NASA Innovative Advanced Concepts - Phase 1 Study

The Spectrally Resolved Synthetic-Aperture Imaging Interferometer (SRSAII) is a system proposed to provide high-resolution and high-sensitivity measurements of astronomical objects. SRSAII uses long baseline interferometric methods to achieve the resolution and low-noise, high time-precision detection to achieve the sensitivity. The primary goal of the SRSAII study was to lay out a framework for using new optical physics technologies to directly resolve, both spatially and spectrally, the disk of an exoplanet. In addition to the ambitious goal of directly resolving an exoplanet, the SRSAII team also sought to identify science opportunities achievable with intermediate system configurations which may offer resolution significantly higher than the current state of the art, but insufficient for direct resolution of an exoplanetary disk. An operational SRSAII system can function with essentially arbitrarily large baselines, achieving correspondingly high angular resolution. The primary limitation occurs in the system sensitivity, which became the major technical focus for study. In this report, we compare the predicted performance (sensitivity in SNR (Signal-to-Noise Ratio) along with angular resolution) of three interferometric techniques: direct detection (also known as homodyne interferometry), multi-channel intensity interferometry (using the Hanbury Brown and Twiss effect), and multi-channel heterodyne interferometry (using an optical frequency comb as a local oscillator). Additionally, quantum-assisted interferometry is also explored as a prospective enhancement of established methods. This report presents a survey of the technologies that enable the SRSAII techniques - optical frequency combs, single photon detectors, and photonic integrated circuits. These technologies are the basis of methods critical to SRSAII's success: precision timing, length and frequency metrology, sensitive photodetection, fine-scale wavelength filtering, and dense multi-channel operation. Lastly, we give some notional performance metrics and propose some possible experimental observations.

High Resolultion↗

Tropical Cyclones in Global Storm-Resolving Models

Recent progress in computing and model development has initiated the era of global storm-resolving modeling, and with it the potential to transform weather and climate prediction. Within the general theme of vetting this new class of models, the present study evaluates nine global-storm resolving models in their ability to simulate tropical cyclones (TCs). Results indicate that, broadly speaking, the models produce realistic TCs and remove longstanding issues known from global models such as the deficiency in accurately simulating TC intensity. However, TCs are strongly affected by model formulation, and all models suffer from unique biases regarding the number of TCs, intensity, size, and structure. Some models simulated TCs better than others, but no single model was superior in every way. The overall results indicate that global storm-resolving models can open a new chapter in TC prediction, but they need to be improved to unleash their full potential.

Falko Judt↗

REQUIEM-2D Methodology: Spatially Resolved Stellar Populations of Massive Lensed Quiescent Galaxies from Hubble Space Telescope 2D Grism Spectroscopy

We present a novel Bayesian methodology to jointly model photometry and deep Hubble Space Telescope 2D grism spectroscopy of high-redshift galaxies. Our requiem2d code measures both unresolved and resolved stellar populations, ages, and star formation histories (SFHs) for the ongoing REsolving QUIEscent Magnified (REQUIEM) Galaxies Survey, which targets strong gravitationally lensed quiescent galaxies at z ∼ 2. We test the accuracy of requiem2d using a simulated sample of massive galaxies at z ∼ 2 from the Illustris cosmological simulation and find that we recover the general trends in SFH and median stellar ages. We further present a pilot study for the REQUIEM Galaxies Survey: MRG-S0851, a quintuply imaged, massive (log M ⁎ / M ʘ = 11.02 ± 0.04) red galaxy at z = 1.883 ± 0.001. With an estimated gravitational magnification of µ = 5.7 - 0.2 + 0.4, we sample the stellar populations on 0.6 kpc physical size bins. The global mass-weighted median age is constrained to be 1.8 - 0.2 + 0.3 Gyr, and our spatially resolved analysis reveals that MRG-S0851 has a flat age gradient in the inner 3 kpc core after taking into account the subtle effects of dust and metallicity on age measurements, favoring an early formation scenario. The analysis for the full REQUIEM-2D sample will be presented in a forthcoming paper with a beta release of the requiem2d code.

Strong gravitational lensing↗

Development of Langmuir and Spatially Resolved OES Diagnostics for Arc Jet Shock and Boundary Layer Measurements Relevant to Atmospheric Re-Entry Environments

The second-generation miniature Arc Jet Research Chamber (mARC) ground testing facility at NASA Ames requires physical characterization of its supersonic plasma flow to verify numerical models and material sample testing. Two types of plasma diagnostics will be utilized: Langmuir probes and optical emission spectroscopy (OES). Several single and triple Langmuir probes have been constructed and will be inserted parallel to the flow via a sweep arm to measure post-shock electron temperature and number density along radial profiles at different axial distances. Due to the high heat flux (200-3000 W/cm2) sweep durations are necessarily short (< 0.1 s). Measuring these properties near the probe surface provide characterization of the post-shock environment. This is an important metric for validating coupled CFD-material codes, and will provide insight into longstanding thermocouple anomalies attributed to charging of heatshield surfaces. An OES system has also been assembled to obtain spatially resolved density and temperature for various flow species. The system consists of a convex lens that forms an image of the plasma onto a 16-channel linear fiber array, which will simultaneously capture the spectra from sixteen different locations. The light emission from the plasma is then focused by a spherical mirror into a spectrometer and recorded with a camera. These measurements non-intrusively provide a new spatially resolved flow characterization capability. This will initially be used to resolve issues with shock radiation interference in pyrometer measurements of material surface temperature. The design of each diagnostic and any initial results will be discussed.

Ethan Main-Loam Leong↗

Collaborative Research Proposal: Time Resolved Optical Emissions Spectroscopy and Laser Induced Fluorescence Spectroscopy of Nanosecond Pulsed Discharges in a Gas-Liquid Water Film Reactor

Electrical discharge plasma formed in contact with liquid water is of interest for a wide range of applications in chemical, biomedical, agricultural, electrical, and materials science and engineering. Such plasma reactors are of very timely importance since they also have significant disinfection capability by inactivating bacteria, viruses and other pathogens. Many types of plasma sources including those driven by AC, DC, RF, microwave, and pulsed electrical power supplies coupled to a wide range of different electrode configurations and reactor designs have been developed and explored which contact the plasma with liquid water. Recent roadmaps have recommended that further work is needed to develop our understanding of the fundamental chemical and physical process which occur at the interface of non-thermal plasma with liquid water solutions in order to advance this large diversity of applications which ultimately depend upon efficient production of key reactive chemical species. There is a wide range of interacting factors that affect the chemical reactions that occur in the plasma, in the liquid phase, and at the interface. These factors ultimately govern the key reactive chemical species formed and used in the various applications and they include a) the reactor design and input parameters, b) the discharge and transport processes, c) the plasma properties, and d) the resulting chemical reactions. For pulsed discharges, the power supply design and output parameters control the applied voltage, frequency, rise time, and width (duration) of the applied pulses. The reactor design involves specification of the gas-liquid contacting methods, electrode gap distance, reactor volume and shape, and gas and liquid flow rates achievable. The gas and liquid compositions as well as the liquid properties such as pH and conductivity are also of key importance in determination of the resulting chemical reactions. In addition, the important plasma properties include plasma gas temperature, electron density, electron energy (distribution), and size of the plasma channels which are all affected by the discharge and transport properties. Many studies have focused on specific aspects of these various processes. Of particular important and relevance to the proposed work is the utilization of nanosecond pulses to generate plasma in gas-liquid systems, liquid bubbles, underwater, and in gases. Recent advances in nanosecond pulses provide significant advantages in utilization with liquid water. For example, fast rise time and short pulses are less sensitive to water conductivity, such short pulses may provide advantages in fast temporal quenching of the plasma, and fundamental analysis of pulse properties, including pulse shape and width, may be facilitated by investigation of single filamentary fast pulses. Many studies have also dealt with the role of the gas composition on formation of reactive oxygen species (ROS) (i.e., hydroxyl radicals – ·OH, hydrogen peroxide – H 2 O 2 , various atomic oxygen species, ozone-O 3 , hydroperoxyl radicals HO 2 ·) and reactive nitrogen species (RNS) (i.e., nitrogen oxides – NO, NO 2 , N 2 O - collectively termed NO X , nitrite-NO 2 - , nitrate-NO 3 - , peroxynitrite-ONOO - ). The hydroxyl radical is the critical species in many chemical oxidation reactions for chemical degradation of toxic compounds in water and gases and for synthesis of some compounds. The mixture of various nitrogen oxide species is important for many biochemical and biological processes involved in biomedical and agricultural applications including disinfection and fertilizer production. The present proposal focuses on determination of the effects of time resolved electron density and hydroxyl radicals on plasma chemical reactions through collaboration with the Princeton Collaborative Low Temperature Plasma Research Facility (PCRF) at the Princeton Plasma Physics Laboratory (PPPL). In order to further investigate the role of the plasma generated electrons and hydroxyl radicals on the overall formation of the key species including hydrogen peroxide, hydroxyl radicals, and nitrogen oxides, the proposed work, thus seeks to determine high resolution time resolved electron density by optical emissions spectroscopy and time resolved hydroxyl radicals using laser induced fluorescence in the nanosecond discharge reactor. The combination of data on electron density and hydroxyl radical concentration will be utilized in the present work to more fully characterize the chemical reaction processes in this system and to advance the design, development, and operation of such chemical reactors for a wide range of applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distinguishing bulk and surface recombination in CdTe thin films and solar cells using time-resolved terahertz and photoluminescence spectroscopies

Understanding the nature of recombination and its dependence on defects and interfaces is essential for engineering materials and contacts for higher open circuit voltage (V oc ) and power conversion efficiency in photovoltaic (PV) devices. Time-resolved photoluminescence (TRPL) has conventionally been used to evaluate recombination, but carrier redistribution often dominates the response at short times. In this work, we report on the quantification of carrier dynamics and recombination mechanisms by complementary use of both time-resolved terahertz spectroscopy (TRTS) and TRPL combined with numerical modeling of the continuity equations and Poisson’s equation. We have demonstrated this approach using CdTe thin films. A thin film stack with CdTe fabricated by vapor transport deposition and treated with CdCl 2 exhibited a bulk lifetime of 1.7 ± 0.1 ns, negligible CdTe/CdS interface recombination velocity, and back surface recombination velocity of 6.3 ± 1.3 x10 4 cm/s. In contrast, a film stack without CdCl 2 treatment had a bulk lifetime of only 68 ± 12 ps and a higher interface recombination velocity of 4 ± 2 x10 8 cm/s. By determining the locus and mechanisms of performance-limiting recombination, we can accelerate the development of thin-film PVs with higher V oc and efficiency. While the method has been demonstrated here using CdTe, it is also applicable to perovskites, Cu(InGa)Se 2 , Cu2ZnSn(S,Se) 4, and emerging technologies.

14 SOLAR ENERGY↗

Photophysical and Time‐resolved Infrared Properties of Long‐Lived Rhenium(I) 4,5‐Diazafluorene Tricarbonyl Chromophores

This report investigates the synthesis, structural characterization, fundamental molecular photophysics, electrochemistry, UV-Vis spectroelectrochemistry, and time-resolved infrared spectroscopic properties of eight [fac-Re(dafR)(CO) 3 L] 0/+ complexes, where R=ethyl [(dedaf); 1, 3, 5, 7] or H [(dafH); 2, 4, 6, 8] and L=Cl− (1, 2), imidazole [(Im); 3, 4], 4-ethylpyridine [(4-Etpy); 5, 6], or pyridine [(py); 7, 8]. Universally, 1–8 yield higher energy photoluminescence (PL) emission bands and higher PL quantum yields (up to 53 %) than the classic 2,2’-bipyridine (bpy) and 1,10-phenanthroline (phen) ligated Re(I) tricarbonyl complexes. The excited state lifetimes of 1–8 lie between those corresponding to the bpy and phen derivatives, ranging from 120 and 1300 ns at room temperature. Combinations of reductive UV-Vis spectroelectrochemistry, transient absorption spectroscopy, and time-resolved infrared spectroscopy consistently assigned the lowest excited states in 1–8 being of metal-to-ligand charge transfer (MLCT) character. These new ReI MLCT chromophores follow classic energy gap law behavior and possess the characteristics necessary for serving as valuable photosensitizers suitable to energize excited state electron and energy transfer photochemistry.

Charge transfer↗

ExaWind: Open‐source CFD for hybrid‐RANS/LES geometry‐resolved wind turbine simulations in atmospheric flows

Abstract Predictive high‐fidelity modeling of wind turbines with computational fluid dynamics, wherein turbine geometry is resolved in an atmospheric boundary layer, is important to understanding complex flow accounting for design strategies and operational phenomena such as blade erosion, pitch‐control, stall/vortex‐induced vibrations, and aftermarket add‐ons. The biggest challenge with high‐fidelity modeling is the realization of numerical algorithms that can capture the relevant physics in detail through effective use of high‐performance computing. For modern supercomputers, that means relying on GPUs for acceleration. In this paper, we present ExaWind, a GPU‐enabled open‐source incompressible‐flow hybrid‐computational fluid dynamics framework, comprising the near‐body unstructured grid solver Nalu‐Wind, and the off‐body block‐structured‐grid solver AMR‐Wind, which are coupled using the Topology Independent Overset Grid Assembler. Turbine simulations employ either a pure Reynolds‐averaged Navier–Stokes turbulence model or hybrid turbulence modeling wherein Reynolds‐averaged Navier–Stokes is used for near‐body flow and large eddy simulation is used for off‐body flow. Being two‐way coupled through overset grids, the two solvers enable simulation of flows across a huge range of length scales, for example, 10 orders of magnitude going from O(μm) boundary layers along the blades to O(10 km) across a wind farm. In this paper, we describe the numerical algorithms for geometry‐resolved turbine simulations in atmospheric boundary layers using ExaWind. We present verification studies using canonical flow problems. Validation studies are presented using megawatt‐scale turbines established in literature. Additionally presented are demonstration simulations of a small wind farm under atmospheric inflow with different stability states.

17 WIND ENERGY↗

Nanosecond time-resolved infrared spectroscopy for the study of electron transfer in photosystem I

Abstract Microsecond time-resolved step-scan FTIR difference spectroscopy was used to study photosystem I (PSI) from Thermosynechococcus vestitus BP-1 ( T. vestitus, formerly known as T. elongatus ) at 77 K. In addition, photoaccumulated (P700 + –P700) FTIR difference spectra were obtained at both 77 and 293 K. The FTIR difference spectra are presented here for the first time. To extend upon these FTIR studies nanosecond time-resolved infrared difference spectroscopy was also used to study PSI from T. vestitus at 296 K. Nanosecond infrared spectroscopy has never been used to study PSI samples at physiological temperatures, and here it is shown that such an approach has great value as it allows a direct probe of electron transfer down both branches in PSI. In PSI at 296 K, the infrared flash-induced absorption changes indicate electron transfer down the B- and A-branches is characterized by time constants of 33 and 364 ns, respectively, in good agreement with visible spectroscopy studies. These time constants are associated with forward electron transfer from A 1 – to F X on the B- and A-branches, respectively. At several infrared wavelengths flash-induced absorption changes at 296 K recover in tens to hundreds of milliseconds. The dominant decay phase is characterized by a lifetime of 128 ms. These millisecond changes are assigned to radical pair recombination reactions, with the changes being associated primarily with P700 + rereduction. This conclusion follows from the observation that the millisecond infrared spectrum is very similar to the photoaccumulated (P700 + –P700) FTIR difference spectrum.

59 BASIC BIOLOGICAL SCIENCES↗

A new 181 Ta neutron resolved resonance region evaluation

A new 181 Ta neutron resolved resonance region evaluation has been performed from the thermal energy range up to approximately 2.5 keV. The R-matrix SAMMY code was used with the Reich–Moore approximation to evaluate resonance parameters from several experimental data sets. A Monte Carlo approach was used for resonance spin assignments and generating 59 small fictitious resonance levels which were shown to improve the cumulative level, Porter-Thomas, and Wigner distributions as compared to theoretical predictions. Covariance information was also generated for the entire resolved resonance region. Finally, the positive impact of the new evaluation was validated through benchmark calculations which were sensitive to the 181 Ta cross section and showed improvement in the reactivity bias for several benchmark cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗

A particle resolved simulation approach for studying shock interactions with moving, colliding solid particles

This work applies a new combination of techniques for the fully resolved simulation of compressible, gas–particle multiphase flows. Here, the adaptive wavelet collocation method is used to dynamically, and efficiently, adapt the computational grid to localized flow features and the particles. A characteristic-based volume penalization method that imposes arbitrary Dirichlet, Neumann, or Robin-type immersed boundary conditions, is used to enforce the no-slip condition at particle surfaces. A hard-sphere collision model is applied to capture the particle–particle collisions. Proof of concept test cases are presented, showcasing the dynamic grid adaptation and fully resolved two-way coupling between the phases that is possible with this approach. Results for a shock-driven single cylinder under viscous and inviscid conditions are presented along with a demonstration of a shock interacting with a cloud of randomly distributed cylinders and spheres.

42 ENGINEERING↗