Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Overview of ion source characterization diagnostics in INTF

INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

H- ion source developments at the SNS

The U.S. Spallation Neutron Source (SNS) will require substantially higher average and pulse H- beam currents than can be produced from conventional ion sources such as the base line SNS source. H- currents of 40-50 mA (SNS operations) and 70-100 mA (power upgrade project) with an rms emittance of 0.20-0.35 Pi mm mrad and a ~7% duty factor will be needed. We are therefore investigating several advanced ion source concepts based on RF excitation. First, the performance characteristics of an external antenna source based on an Al2O3 plasma chamber combined with an external multicusp magnetic configuration, an elemental Cs system, and plasma gun will be discussed. Second, the first plasma measurements of a helicon-driven H- ion source will also be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam Homogeneity Dependence on the Magnetic Filter Field at the IPP Test Facility MANITU

The homogeneity of the extracted current density from the large RF driven negative hydrogen ion sources of the ITER neutral beam system is a critical issue for the transmission of the negative ion beam through the accelerator and the beamline components. As a first test, the beam homogeneity at the IPP long pulse test facility MANITU is measured by means of the divergence and the stripping profiles obtained with a spatially resolved Doppler-shift spectroscopy system. Since MANITU is typically operating below the optimum perveance, an increase in the divergence corresponds to a lower local extracted negative ion current density if the extraction voltage is constant. The beam H{sub {alpha}} Doppler-shift spectroscopy is a rather simple tool, as no absolute calibration - both for the wavelength and the emission - is necessary. Even no relative calibration of the different used lines of sight is necessary for divergence and stripping profiles as these quantities can be obtained by the line broadening of the Doppler-shifted peak and the ratio of the integral of the stripping peak to the integral of the Doppler-shifted peak, respectively. The paper describes the H{sub {alpha}} MANITU Doppler-shift spectroscopy system which is now operating routinely and the evaluation methods of the divergence and the stripping profiles. Beam homogeneity measurements are presented for different extraction areas and magnetic filter field configurations both for Hydrogen and Deuterium operation; the results are compared with homogeneity measurements of the source plasma. The stripping loss measurements are compared with model calculations.

43 PARTICLE ACCELERATORS↗

H{sup -} ion source developments at the SNS

The U.S. Spallation Neutron Source (SNS) will require substantially higher average and pulse H{sup -} beam currents than can be produced from conventional ion sources such as the base line SNS source. H{sup -} currents of 40-50 mA (SNS operations) and 70-100 mA (power upgrade project) with a rms emittance of 0.20-0.35{pi} mm mrad and a {approx}7% duty factor will be needed. We are therefore investigating several advanced ion source concepts based on rf plasma excitation. First, the performance characteristics of an external antenna source based on an Al{sub 2}O{sub 3} plasma chamber combined with an external multicusp magnetic configuration, an elemental Cs system, and plasma gun will be discussed. Second, the first plasma measurements of a helicon-driven H{sup -} ion source will also be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High duty factor plasma generator for CERN's Superconducting Proton Linac

CERN's Linac4 is a 160 MeV linear accelerator currently under construction. It will inject negatively charged hydrogen ions into CERN's PS-Booster. Its ion source is a noncesiated rf driven H{sup -} volume source directly inspired from the one of DESY and is aimed to deliver pulses of 80 mA of H{sup -} during 0.4 ms at a 2 Hz repetition rate. The Superconducting Proton Linac (SPL) project is part of the luminosity upgrade of the Large Hadron Collider. It consists of an extension of Linac4 up to 5 GeV and is foreseen to deliver protons to a future 50 GeV synchrotron (PS2). For the SPL high power option (HP-SPL), the ion source would deliver pulses of 80 mA of H{sup -} during 1.2 ms and operate at a 50 Hz repetition rate. This significant upgrade motivates the design of the new water cooled plasma generator presented in this paper. Its engineering is based on the results of a finite element thermal study of the Linac4 H{sup -} plasma generator that identified critical components and thermal barriers. A cooling system is proposed which achieves the required heat dissipation and maintains the original functionality. Materials with higher thermal conductivity are selected and, wherever possible, thermal barriers resulting from low pressure contacts are removed by brazing metals on insulators. The AlN plasma chamber cooling circuit is inspired from the approach chosen for the cesiated high duty factor rf H{sup -} source operating at SNS.

42 ENGINEERING↗

Enhanced surface production in H{sup -} ion sources by introducing a negatively biased secondary electrode

A transformer coupled plasma negative hydrogen ion source with an external rf antenna has been developed at SNU, which is capable of continuous operation with long lifetime. A positively biased plasma electrode (PE) has been successfully used for the optimization of H{sup -} extraction. With molybdenum-coated stainless steel PE, the enhancement of H{sup -} production at the electrode surface was observed at the bias voltage lower than the plasma potential. However, the low bias voltage is unfavorable to H{sup -} beam extraction since the negative ions are repelled. A second electrode is inserted in front of the PE to enhance H{sup -} production at the electrode surface without impeding beam extraction. By biasing the secondary electrode (SE) more negatively, H{sup -} production is clearly enhanced although the SE itself reduces H{sup -} beam currents because of suppressed electron transport in front of the PE. In this configuration enhancement of surface productions is most pronounced in tantalum electrode among various electrode materials.

43 PARTICLE ACCELERATORS↗

Upgrade of the BATMAN test facility for H{sup −} source development

The development of a radio frequency (RF) driven source for negative hydrogen ions for the neutral beam heating devices of fusion experiments has been successfully carried out at IPP since 1996 on the test facility BATMAN. The required ITER parameters have been achieved with the prototype source consisting of a cylindrical driver on the back side of a racetrack like expansion chamber. The extraction system, called “Large Area Grid” (LAG) was derived from a positive ion accelerator from ASDEX Upgrade (AUG) using its aperture size (ø 8 mm) and pattern but replacing the first two electrodes and masking down the extraction area to 70 cm2. BATMAN is a well diagnosed and highly flexible test facility which will be kept operational in parallel to the half size ITER source test facility ELISE for further developments to improve the RF efficiency and the beam properties. It is therefore planned to upgrade BATMAN with a new ITER-like grid system (ILG) representing almost one ITER beamlet group, namely 5 × 14 apertures (ø 14 mm). Additionally to the standard three grid extraction system a repeller electrode upstream of the grounded grid can optionally be installed which is positively charged against it by 2 kV. This is designated to affect the onset of the space charge compensation downstream of the grounded grid and to reduce the backstreaming of positive ions from the drift space backwards into the ion source. For magnetic filter field studies a plasma grid current up to 3 kA will be available as well as permanent magnets embedded into a diagnostic flange or in an external magnet frame. Furthermore different source vessels and source configurations are under discussion for BATMAN, e.g. using the AUG type racetrack RF source as driver instead of the circular one or modifying the expansion chamber for a more flexible position of the external magnet frame.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matrix of small-radius radio-frequency discharges as a volume-production based source of negative hydrogen ions

Based on experience from a work - both theoretical and experimental one - on negative hydrogen ion beam sources studied regarding fusion applications, a novel design of a rf source with volume production of the ions is proposed. The suggestion is for a source constructed as a matrix of small-radius tandem discharges (with magnetic filters largely extended over the discharge length), inductively driven (by a single coil, for the whole matrix) and with a single aperture extraction from each of them.

43 PARTICLE ACCELERATORS↗

Neutral particle dynamics in a high-power RF source

Previous studies on the spatial discharge structure in the SPIDER source of negative hydrogen/deuterium ions carried out at low applied power are extended towards description of the discharge maintenance under the conditions of the actual rf power deposition of 100 kW planned for a single driver of the source. In addition to the expected higher electron density, the results show strong increase of the electron temperature and of the temperatures of the neutral species (hydrogen atoms and molecules). In the discussions, not only the spatial distribution of the plasma parameters but also that of the fluxes in the discharge (particle and energy fluxes) is involved. The obtained results come in confirmation of basic concepts for low-pressure discharge maintenance: (i) mutually related electron density and temperature as a display of the generalized Schottky condition, (ii) discharge behavior governed by the fluxes, i.e. strong nonlocality in the discharge, and (iii) a non-ambipolarity in the discharge regime, which originates from shifted maxima of the electron density and temperature and shows evidence in a vortex electron flux and in a dc current in a rf discharge, the latter resulting from a shift in the positions of the maxima of the electron density and plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical investigation of ion energy distribution and ion angle distribution in a dual-frequency capacitively coupled plasma with a hybrid model

A one-dimensional hybrid model is developed to study the characteristics of energy and angular distributions of the ions and fast neutrals impinging on the rf-biased electrode in a dual-frequency capacitively coupled Ar discharge. The hybrid model consists of a fluid model that determines the spatiotemporal evolution of the discharge, and a Monte-Carlo model that, including the electron-neutral, ion-neutral, and fast neutral-neutral collisions, predicts the energy and angular distributions of the ions and fast neutrals on the rf-biased electrode. The influence of pressure, voltage amplitude, and frequencies of the two rf sources on the energy and angular distributions is discussed. The ion energy distributions (IEDs) appear to have multiple peaks in the dual-frequency capacitively coupled rf discharge rather than bimodal shape in a conventional single-frequency rf discharge. The ion angle distributions (IADs) have a significant peak at a small angle, and most ions strike to the process surface with the angle less than 4 deg. With the increase of the pressure, the maximum energy of IEDs and the peaks of IADs decrease. The structures of IEDs are controlled mainly by the voltage and frequency applied to the two rf sources. By decreasing the frequency or adding the voltage applied to the low-frequency (LF) source, the width of IEDs and the maximum energy increase. More ions strike to the electrode with a small angle by increasing either the voltage of LF source or the frequency of high-frequency source. The energy and angular distributions of the fast neutrals are correlative with those of the ions. Compared with the ions, the fast neutrals have a much lower energy and the scattering effect becomes more prominent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation study of ion beam used to produce Mo-99

An 820 mA CW positive ion source is being developed to produce Mo-99 using the fusion of deuterium and tritium ion beams on a rotating target to produce neutrons for use in the production of radiopharmaceuticals. The ion source consists of an RF plasma source, a multi-aperture extractor, and 300 kV accelerating column. This paper will describe a simulation study of the beam through the extractor grid and the accelerator to the target. The uniformity of beam distribution on the target is an important aspect of the simulation.

43 PARTICLE ACCELERATORS↗

Next Generation H- Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H{sup -} ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H{sup -} ion source based on an AlN ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA (60Hz, 1ms) have been observed and sustained currents >60 mA (60Hz, 1ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H{sup -} beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

33 ADVANCED PROPULSION SYSTEMS↗

Long pulse large area beam extraction with a rf driven H{sup -}/D{sup -} source

IPP Garching is heavily involved in the development of the rf driven H{sup -}/D{sup -} ion source for the ITER NBI. After the successful demonstration of the required physical parameters, the experimental conditions have been extended to long pulses and large area beam extraction. This paper contains descriptions of the source and power supply modifications necessitated for long pulses as well as the latest results including the first 1 h pulse. Suppression of the coextracted electron current is a key issue. Experiments with potential control, different magnetic filter fields, and cesium handling to suppress the electrons and stabilize the currents are also reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Finite element thermal study of the Linac4 plasma generator

The temperature distribution and heat flow at equilibrium of the plasma generator of the rf-powered noncesiated Linac4 H{sup -} ion source have been studied with a finite element model. It is shown that the equilibrium temperatures obtained in the Linac4 nominal operation mode (100 kW rf power, 2 Hz repetition rate, and 0.4 ms pulse duration) are within material specifications except for the magnet cage, where a redesign may be necessary. To assess the upgrade of the Linac4 source for operation in the high-power operation mode of the Superconducting Proton Linac (SPL), an extrapolation of the heat load toward 100 kW rf power, 50 Hz repetition rate, and 0.4 ms pulse duration has been performed. The results indicate that a significant improvement of the source cooling is required to allow for operation in the high-power mode of SPL.

43 PARTICLE ACCELERATORS↗

Improvements to the internal and external antenna H{sup −} ion sources at the Spallation Neutron Source

The Spallation Neutron Source (SNS), a large scale neutron production facility, routinely operates with 30–40 mA peak current in the linac. Recent measurements have shown that our RF-driven internal antenna, Cs-enhanced, multi-cusp ion sources injects ∼55 mA of H{sup −} beam current (∼1 ms, 60 Hz) at 65-kV into a Radio Frequency Quadrupole (RFQ) accelerator through a closely coupled electrostatic Low-Energy Beam Transport system. Over the last several years a decrease in RFQ transmission and issues with internal antennas has stimulated source development at the SNS both for the internal and external antenna ion sources. This report discusses progress in improving internal antenna reliability, H{sup −} yield improvements which resulted from modifications to the outlet aperture assembly (applicable to both internal and external antenna sources) and studies made of the long standing problem of beam persistence with the external antenna source. The current status of the external antenna ion source will also be presented.

43 PARTICLE ACCELERATORS↗

Ion Source Development at the SNS

The Spallation Neutron Source (SNS) now routinely operates near 1 MW of beam power on target with a highly-persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. The {approx}1 ms-long, 60 Hz, {approx}50 mA H{sup -} beam pulses are extracted from a Cs-enhanced, multi-cusp, RF-driven, internal-antenna ion source. An electrostatic LEBT (Low Energy Beam Transport) focuses the 65 kV beam into the RFQ accelerator. The ion source and LEBT have normally a combined availability of {approx}99%. Although much progress has been made over the last years to achieve this level of availability further improvements are desirable. Failures of the internal antenna and occasionally impaired electron dump insulators require several source replacements per year. An attempt to overcome the antenna issues with an AlN external antenna source early in 2009 had to be terminated due to availability issues. This report provides a comprehensive review of the design, experimental history, status, and description of recently updated components and future plans for this ion source. The mechanical design for improved electron dump vacuum feedthroughs is also presented, which is compatible with the baseline and both external antenna ion sources.

07 ISOTOPE AND RADIATION SOURCES↗