Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Standard”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Proper orthogonal decomposition based reduced-order modeling of flux-Limited gray thermal radiation

Here, in this work, a proper orthogonal decomposition (POD) based reduced-order model (ROM) is developed to solve gray, flux-limited thermal radiation diffusion. We focus on the variable opacity radiation penetration benchmark posed by Olson, Auer, and Hall. The T -3 relationship for opacity in conjunction with high-temperature radiation penetrating an initially cold material produces a strong thermal radiation shock. This class of problems is particularly challenging for standard POD-based reduced-order modeling due to the nonlinearities presented by 1) the T 4 source term, and 2) flux-limited diffusion operator. To address these challenges and develop a cost competitive ROM, we employ a “hyper-reduction” technique through discrete empirical interpolation (DEIM) and allow for adaptive reduced-order projections through principal interval decomposition (PID). Performance of the proposed methodology is quantified by comparing the cost savings and accuracy relative to a full-order computation. Reference solutions and snapshot data are obtained through a full-order calculation performed by the University of Chicago maintained astrophysics code, FLASH. For consistency and potential extensibility, the developed ROM is also implemented in FLASH. We find that in the initialization regime, where the thermal radiation wave is initially created by the warming of the material, this class of problems is highly reducible and suitable for POD-based ROMs. However, the strong convective nature of the wave propagation regime is less reducible and more challenging to create an efficient ROM.

42 ENGINEERING↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Calculating the angle between jet axes

We study the angle between i) the standard jet axis, ii) the axis of a jet which has been groomed using soft drop, with reduced sensitivity to soft radiation, iii) the jet axis obtained with the winner-take-all recombination scheme, which is insensitive to soft radiation at leading power. We calculate the distributions for these angles at next- to-leading logarithmic accuracy, including non-global logarithms. The angle between the standard and groomed jet axis directly probes soft wide-angle radiation, leading to a novel factorization formula. This angle is also very sensitive to nonperturbative physics, which is directly connected to nonperturbative contribution to the rapidity anomalous dimension for transverse momentum distributions. Comparing our predictions to Pythia we find good agreement, and we foresee applications to jet substructure in proton-proton and heavy ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PNNL Sequim Campus Radionuclide Air Emissions Report for Calendar Year 2025 : Department of Energy – Office of Science Pacific Northwest National Laboratory

The U.S. Department of Energy Office of Science’s Pacific Northwest Site Office has oversight and stewardship duties associated with the Pacific Northwest National Laboratory Sequim Campus. Facility operations include radiological operations with the potential-to-emit low levels of radioactive materials. This report is prepared to document compliance with the 40 CFR Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,” and Washington Administrative Code Chapter 246-247, Radiation Protection–Air Emissions. The PNNL Sequim Campus is in compliance with the federal and state 10 mrem/yr standard for 2025 operations.

40 CFR 61 Subpart H↗

Exceptional points in a passive strip waveguide

Abstract Exceptional points (EPs) in non‐Hermitian systems have attracted significant interest due to their unique behaviors, including novel wave propagation and radiation. While EPs have been explored in various photonic systems, their integration into standard photonic platforms can expand their applicability to broader technological domains. In this work, we propose and experimentally demonstrate EPs in an integrated photonic strip waveguide configuration, exhibiting unique deep wave penetration and uniform‐intensity radiation profiles. By introducing the second‐order grating on one side of the waveguide, forward and backward propagating modes are coupled both directly through second‐order coupling and indirectly through first‐order coupling via a radiative intermediate mode. To describe the EP behavior in a strip configuration, we introduce modified coupled‐mode equations that account for both transverse and longitudinal components. These coupled‐mode formulas reveal the formation of EPs in bandgap closure, achieved by numerically optimizing the grating’s duty cycle to manipulate the first‐ and second‐order couplings simultaneously. Experimental observations, consistent with simulations, confirm the EP behavior, with symmetric transmission spectra and constant radiation profiles at the EP wavelength, in contrast to conventional exponential decay observed at detuned wavelengths. These results demonstrate the realization of EPs in a widely applicable strip waveguide configuration, paving the way for advanced EP applications in nonlinear and ultrafast photonics, as well as advanced sensing technologies.

Materials Science↗

Progress on Light-Element Standard Cross Sections at Los Alamos [Slides]

Presenters identified the following statuses of the light-element standards: Extension of N-N scattering analysis to 200 MeV will likely come in time for ENDF/B VIII.1 and new data are to be added even in the energy range up to 100 MeV; for n- 3 He, a more recent 4 He R-matrix analysis from which updated n+ 3 He cross sections could be obtained for ENDF/B VIII.1; for n- 6 Li, more work is required to get a reasonable fit to all data up to E n = 8 MeV. Of particular concern are the t+ 4 He scattering data at E t > 14 MeV. For n- 10 B, new work on the 11 B system has not yet been started and there is much new data to add for n+ 10 B reactions, and maybe also for &#945 + 7 Li reactions. The proliferation of excited-state channels will limit the upper neutron energy of the analysis to a few MeV. For n- 12 C, new elastic and inelastic scattering data from Vanhoy support the results of the present analysis. More work is needed to extend the fit successfully above 6.5 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Prospective Trial Demonstrating the Benefit of Personalized Selection Of Breath-Hold Technique for Upper-Abdominal Radiation Therapy Using the Active Breathing Coordinator

For upper abdominal tumors, our institutional-standard motion reduction method is the expiration breath-hold (EBH) technique, using Active Breathing Coordinator (ABC). However, an individual patient's breath-hold (BH) reproducibility (R{sub BH}) may be improved in deep inspiration or inspiration breath-hold (DIBH or IBH). This trial compared the tumor position R{sub BH}, stability (S{sub BH}), and breath-hold time (T{sub BH}) of 3 BH methods, using ABC, to personalize the selection of technique, by using a preplanning screening assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of B255 R183 C-Cell Cobalt-60 Irradiator Pool

Characterization of the Radiation Calibration and Spectroscopy Laboratory (RCS) Co-60 source radiation pool was successfully completed. The characterization was done by performing several measurements of dose rate in the center of the Co-60 source radiation pool and at multiple heights from the bottom of the pool. The measurements were taken between November 2018 through January 2019. Opti-Chromic FWT-70-40M dosimeters were used for this measurement. A 7.3 cm inner diameter stainless steel cylinder (vessel) was used to lower the dosimeters to the bottom of the pool inside the 16 cm dimeter Co-60 source basket. The dose rate was measured at heights of 5.5, 12, 19, and 23 cm from the bottom of the pool. The report “Tour of the Standards and Calibration Laboratory” includes information about the Co-60 source radiation pool. The importance of performing the Co-60 source characterization is to confirm previously reported Co-60 source dose rate measurements and to provide a documented measuring procedure for researchers and others who want to use the Co-60 source to evaluate the effects of radiation on space-based equipment for other applications. The measured dose rate at the abovementioned heights was 0.65, 0.69, 0.53, 0.23 krad/min respectively with the highest coefficient of variation of less than 10%.

61 RADIATION PROTECTION AND DOSIMETRY↗

GRB 110213A: A Study of Afterglow Electromagnetic Cascade Radiation

We obtained well-sampled optical photometry of GRB 110213A, including Swift/UVOT and XRT. Combining our data from those of other ground-based telescopes, we present 15 optical multicolor light curves showing similar shapes with two peaks. In contrast, in the X-ray band, only a single peak is observed between the two optical peaks. Temporal and spectral analysis of GRB 110213A shows that the X-rays differ from the optical for Phases I–III (before the second peak of the optical band at ~5.6 ks). Moreover, they have the same spectral behavior at late times (Phases IV–VI). These data indicate that the optical and X-ray emission are dominated by different components. The synchrotron-supported pair cascade emission is included in the standard external forward-shock model, which is dominated by synchrotron radiation and synchrotron self-Compton (SSC). We find that the optical bands of GRB 110213A are dominated by the cascade emission from synchrotron radiation + SSC at the early stage, while the primary synchrotron + SSC radiation dominates the X-ray band. At late stages, both the X-ray and optical bands are dominated by emission from primary synchrotron + SSC radiation. The cascade component can reasonably explain the first optical peak. In contrast, the primary synchrotron + SSC emission mainly contributes to the second peak.

79 ASTRONOMY AND ASTROPHYSICS↗

Abundance and properties of dark radiation from the cosmic microwave background

We study the cosmological signatures of new light relics that are collisionless like standard neutrinos or are strongly interacting. We provide a simple and succinct rephrasing of their physical effects in the cosmic microwave background, as well as the resulting parameter degeneracies with other cosmological parameters, in terms of the total radiation abundance and the fraction thereof that freely streams. In these more general terms, interacting and noninteracting light relics are differentiated by their respective decrease and increase of the free-streaming fraction, and, moreover, the scale-dependent interplay thereof with a common, correlated reduction of the fraction of matter in baryons. We then derive updated constraints on various dark-radiation scenarios with the latest cosmological observations, employing this language to identify the physical origin of the impact of each dataset. The “PR4” reanalyses of Planck CMB data prefer a larger primordial helium yield and therefore also slightly more radiation than the 2018 analysis; we investigate the differences between the two releases that drives these shifts. Smaller free-streaming fractions are disfavored by the excess lensing of the CMB measured in lensing reconstruction data from Planck and the Atacama Cosmology Telescope. On the other hand, baryon acoustic oscillation measurements from the Dark Energy Spectroscopic Instrument drive marginal detections of new, strongly interacting light relics due to that data's preference for lower matter fractions. Finally, we forecast measurements from the CMB-S4 experiment.

cosmological parameters from CMBR↗

Unified framework for B -anomalies, muon g – 2 and neutrino masses

We present a model of radiative neutrino masses which also resolves anomalies reported in B -meson decays, \( {R}_{D^{\left(\ast \right)}} \) and \( {R}_{K^{\left(\ast \right)}} \) , as well as in muon g – 2 measurement, Δ a μ . Neutrino masses arise in the model through loop diagrams involving TeV-scale leptoquark (LQ) scalars R 2 and S 3 . Fits to neutrino oscillation parameters are obtained satisfying all flavor constraints which also explain the anomalies in \( {R}_{D^{\left(\ast \right)}} \) , \( {R}_{K^{\left(\ast \right)}} \) and Δ a μ within 1 σ . An isospin-3/2 Higgs quadruplet plays a crucial role in generating neutrino masses; we point out that the doubly-charged scalar contained therein can be produced in the decays of the S 3 LQ, which enhances its reach to 1.1 (6.2) TeV at \( \sqrt{s} \) = 14 TeV high-luminosity LHC ( \( \sqrt{s} \) = 100 TeV FCC-hh). We also present flavor-dependent upper limits on the Yukawa couplings of the LQs to the first two family fermions, arising from non-resonant dilepton ( pp → ℓ + ℓ – ) processes mediated by t -channel LQ exchange, which for 1 TeV LQ mass, are found to be in the range (0 . 15 – 0 . 36). These limits preclude any explanation of \( {R}_{D^{\left(\ast \right)}} \) through LQ-mediated B -meson decays involving ν e or ν μ in the final state. We also find that the same Yukawa couplings responsible for the chirally-enhanced contribution to Δ a μ give rise to new contributions to the SM Higgs decays to muon and tau pairs, with the modifications to the corresponding branching ratios being at (2–6)% level, which could be tested at future hadron colliders, such as HL-LHC and FCC-hh.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of charged-particle emission in neutron reactions on 10 B

The 10 B + n system has been studied by measuring charged particles from neutron-induced reactions in the 1 to 20 MeV energy range. Protons, deuterons, tritons, and α particles were measured at four angles using the pulsed white neutron spectrum at the Los Alamos Neutron Science Center Weapons Neutron Research facility. Differential cross sections for each species are reported. These new data are combined with literature data in an R-matrix analysis of the 11 B compound system. Furthermore, a comparison is made to the molecular and cluster states candidates observed in these reactions.

43 PARTICLE ACCELERATORS↗

Discovering Dark Energy, Dark Matter, and Neutrino Properties with Cosmic Structures

This research aimed to enhance our understanding of cosmic structure formation in the presence of neutrinos and exotic matter, improve cosmic constraints on neutrino mass, and explore new physics beyond the Standard Model. Major accomplishments include a comprehensive study of dark radiation interactions, theoretical work on neutrino wakes, the development of an improved fluid approximation for massive neutrinos, and deeper insights into nonlinear structure formation. Two graduate students received extensive training, contributing to multiple publications and presentations. The research findings have been widely disseminated through journal publications, conferences and collaborations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring dimethyl sulfide (DMS) oxidation and implications for global aerosol radiative forcing

Abstract. Aerosol indirect radiative forcing (IRF), which characterizes how aerosols alter cloud formation and properties, is very sensitive to the preindustrial (PI) aerosol burden. Dimethyl sulfide (DMS), emitted from the ocean, is a dominant natural precursor of non-sea-salt sulfate in the PI and pristine present-day (PD) atmospheres. Here we revisit the atmospheric oxidation chemistry of DMS, particularly under pristine conditions, and its impact on aerosol IRF. Based on previous laboratory studies, we expand the simplified DMS oxidation scheme used in the Community Atmospheric Model version 6 with chemistry (CAM6-chem) to capture the OH-addition pathway and the H-abstraction pathway and the associated isomerization branch. These additional oxidation channels of DMS produce several stable intermediate compounds, e.g., methanesulfonic acid (MSA) and hydroperoxymethyl thioformate (HPMTF), delay the formation of sulfate, and, hence, alter the spatial distribution of sulfate aerosol and radiative impacts. The expanded scheme improves the agreement between modeled and observed concentrations of DMS, MSA, HPMTF, and sulfate over most marine regions, based on the NASA Atmospheric Tomography (ATom), the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA), and the Variability of the American Monsoon Systems (VAMOS) Ocean-Cloud-Atmosphere-Land Study Regional Experiment (VOCALS-REx) measurements. We find that the global HPMTF burden and the burden of sulfate produced from DMS oxidation are relatively insensitive to the assumed isomerization rate, but the burden of HPMTF is very sensitive to a potential additional cloud loss. We find that global sulfate burden under PI and PD emissions increase to 412 Gg S (+29 %) and 582 Gg S (+8.8 %), respectively, compared to the standard simplified DMS oxidation scheme. The resulting annual mean global PD direct radiative effect of DMS-derived sulfate alone is −0.11 W m−2. The enhanced PI sulfate produced via the gas-phase chemistry updates alone dampens the aerosol IRF as anticipated (−2.2 W m−2 in standard versus −1.7 W m−2, with updated gas-phase chemistry). However, high clouds in the tropics and low clouds in the Southern Ocean appear particularly sensitive to the additional aqueous-phase pathways, counteracting this change (−2.3 W m−2). This study confirms the sensitivity of aerosol IRF to the PI aerosol loading and the need to better understand the processes controlling aerosol formation in the PI atmosphere and the cloud response to these changes.

54 ENVIRONMENTAL SCIENCES↗

Design and performance of a variable gap system for thermal conductivity measurements of high temperature, corrosive, and reactive fluids

We report high-temperature fluids such as molten salts, liquid metals, and gasses are being proposed for many advanced energy systems including thermal energy storage devices, concentrating solar plants, and advanced nuclear reactor designs. However, the chemical behavior and thermophysical properties of many of these fluids have not been well characterized, which hinders the design, modeling, safety analysis, and deployment of these systems. Thermal conductivity is a property that is especially limited by existing measurement capabilities, which are subject to errors caused by convection, material interaction, radiative heat transfer, and instrument degradation. Therefore, there is a lack of standard, systematic measurement techniques for high-temperature, reactive, and corrosive fluids. In this work, the development of a variable gap thermal conductivity measurement system is detailed. The system is designed to measure the thermal conductivity of highly corrosive and reactive fluids, and survive operation between 100 °C and 800 °C. The effects of convection are minimized by limiting the thickness of the specimen to thin sizes (<0.3 mm). Corrections for radiative heat transfer were included in the working equations to consider specimens with varying optical properties. The design, construction, instrumentation, operating principles, and data analysis techniques are discussed in detail. The system was tested up to 500 °C using helium gas and molten KNO 3 -NaNO 3 to verify the measurement technique and determine the sources of error. At 300 and 400 °C KNO 3 -NaNO 3 , results showed maximum relative error of 6% when compared to results in the literature. The helium results were within 13% of those in the literature at 300 and 400 °C. Higher errors were observed at 500 °C for both fluids, and the sources of these errors are discussed.

42 ENGINEERING↗

Cosmological probes of Dark Radiation from Neutrino Mixing

Abstract Models of stepped dark radiation have recently been found to have an important impact on the anisotropies of the cosmic microwave background, aiding in easing the Hubble tension. In this work, we study models with a sector of dark radiation with a step in its abundance, which thermalizes after big bang nucleosynthesis by mixing with the standard model neutrinos. For this, we extend an earlier work which has focused on the background evolution only until the dark sector thermalizes by deriving the full background and perturbation equations of the model and implementing them in an Einstein-Boltzmann solving code. We expound on the behavior of this model, discussing the wide range of parameters that result in interesting and viable cosmologies that dynamically generate dark radiation during a range of epochs. We find that for the strongly self-coupled regime, there is no large cosmological impact for a tight prior on the mass, whereas larger mass ranges allow a smooth interpolation between a behavior close to the ΛCDM cosmological standard model and close to an additional component of strongly self-interacting dark radiation. In the weakly self-coupled regime we find that we can accommodate a parameter space relevant for the neutrino anomalies as well as one relevant to easing the Hubble tension.

Astronomy & Astrophysics↗

Novel Methods to Produce an Argon-37 Standard

The purpose of this research was to produce a measurable quantity of radioactive argon-37 through photonuclear production methods. The detection of argon-37, above background levels, uniquely and clearly indicates the underground detonation of a nuclear device.

07 ISOTOPE AND RADIATION SOURCES↗

Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification

A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. Furthermore, for 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗