Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ten Thousand Solar Constants Radiometer

"Radiometer for Accurate (+ or - 1%) Measurement of Solar Irradiances Equal to 10,000 Solar Constants," gives additional information on radiometer described elsewhere. Self-calibrating, water-cooled, thermopile radiometer measures irradiance produced in solar image formed by parabolic reflector or by multiple-mirror solar installation.

Kendall, J. M., Sr.↗

Spring wheat-leaf phytomass and yield estimates from airborne scanner and hand-held radiometer measurements

An attempt has been made to relate hand-held radiometer measurements, and airborne multispectral scanner readings, with both different wheat stand densities and grain yield. Aircraft overflights were conducted during the tillering, stem extension and heading period stages of growth, while hand-held radiometer readings were taken throughout the growing season. The near-IR/red ratio was used in the analysis, which indicated that both the aircraft and the ground measurements made possible a differentiation and evaluation of wheat stand densities at an early enough growth stage to serve as the basis of management decisions. The aircraft data also corroborated the hand-held radiometer measurements with respect to yield prediction. Winterkill was readily evaluated.

Aase, J. K.↗

Simplified Microwave Radiometer

Cost, weight, and size less than half of conventional radiometers. Ground-based instrument measures temperatures in upper atmosphere while correcting for liquid water in clouds. Addition of channel at 51 GHz to channels used for making upper-atmosphere temperature profiles adds little to cost of microwave radiometer. Eliminates need for separate water-vapor radiometer subsystem, with its attendant size, weight, and cost. Instrument light, compact, and portable and inexpensive enough for use in sensor arrays. Availability encourages use of microwave radiometry for routine weather forecasting.

Gary, Bruce L.↗

A comparative study of infrared radiance measurements by an ER-2 based radiometer and the LANDSAT 5 Thematic Mapper (TM-6)

Infrared radiance measurements were acquired from a radiometer on the NASA ER-2 during a coincident LANDSAT 5 overpass on 28 Oct. 1986 as part of the FIRE Cirrus IFO in the vicinity of Lake Michigan. A comparative study is made to infer microphysical properties of the cirrus cloud field. Radiances are derived from the image by convolving the ER-2 radiometer's effective field of view along the flight path. A multistream radiative transfer model is used to account for the differences in spectral bandwidths, 10.40 to 12.50 microns for the LANDSAT band and 9.90 to 10.87 microns for the radiometer.

Hammer, Philip D.↗

Characterizations of the Earth Radiation Budget Experiment (ERBE) scanning radiometers

NASA's Earth Radiation Budget Experiment employs the Earth Radiation Budget Satellite and the NOAA 9 and 10 spacecraft to obtain absolute measurements of incoming solar radiation, shortwave earth-reflected solar radiation, and longwave earth-emitted radiation, using both scanning and nonscanning radiometers. Each of the three remote-sensing spacecraft carry narrow FOV scanning radiometers whose detection sensors are thermistor bolometers. Attention is presently given to the calibration models and methods employed in characterizing the scanning radiometers' output signals; the design features of the scanners and flight calibration systems are presented.

Lee, Robert B., III↗

Temperature sensitivity of Eppley broadband radiometers

Broadband radiometers manufactured by Eppley Laboratories Inc. are commonly used to measure irradiance from both ground-based and aircraft platforms. Namely, the pyranometer (Model PSP) measures irradiance in the .3 to 3.0 micron spectral region while the pyrgeometer (Model PIR) senses energy in the 4 to 50 micron region. The two instruments have a similar thermopile construction but different filters to achieve the appropriate spectral selection. During the fall of 1986, the First ISCCP (International Satellite Cloud Climatology Project) Regional Experiment (FIRE) commenced with the first cirrus Intensive Field Observation (IFO) conducted in Central Wisconsin. Due to the nature of this field project, pyranometers and pyrgeometers manufactured by Eppley were flown on NCAR's high altitude research aircraft, the Sabreliner. Inherent in the construction of these radiometers is temperature compensation circuitry designed to make the instrument sensitivity nominally constant over a temperature range from -20 to +40 C. Because the Sabreliner flew at high altitudes where temperatures were as cold as -70 C, it was necessary to determine the radiometers relative sensitivity to temperatures below -20 C and apply appropriate corrections to the FIRE radiation data set. A procedure to perform this calibration is outlined. It is meant to serve as a supplement to calibration procedures.

Smith, William L., Jr.↗

Attenuation statistics derived from emission measurements by a network of ground-based microwave radiometers

Two seasons of thermal emission measurements, running from December 1987 through February 1988 and from June through August 1988 of thermal emission measurements, taken by a multi-channel, ground-based microwave radiometer, are used to derive single-station zenith attenuation statistics at 20.6 and 31.65 GHz. For the summer period, statistics are also derived for 52.85 GHz. In addition, data from two dual-channel radiometers, separated from Denver by baseline distances of 49 and 168 km, are used to derive two-station attenuation diversity statistics at 20.6 and 31.65 GHz. The multi-channel radiometer is operated at Denver, Colorado; the dual-channel devices are operated at Platteville and Flagler, Colorado. The diversity statistics are presented by cumulative distributions of maximum and minimum attenuation.

Westwater, E. R.↗

Retrieval of precipitation profiles from airborne radar and passive radiometer measurements - Comparison with dual-frequency radar measurements

Precipitation-rate profiles derived from a single-frequency radar and a radiometer are compared with profiles derived from a dual-frequency radar, using data obtained during the 1985-1986 Communication Research Laboratory/NASA rain measuring experiment over the Atlantic Ocean from a dual-frequency X- and Ka-band radars and an X-band passive radiometer. Profiles were retrieved using a modification of the Hitschfeld-Bordan (1954) algorithm constrained by a measurement of the path integrated extinction derived from passive radiometry. It was found that the two techniques under comparison yielded average rainfall rates that agreed within about 25 percent. It is suggested that, while a single-frequency radar operating in conjunction with multifrequency passive radiometers might provide cost-effective spaceborne measurements of tropical rainfall distributions, a dual-frequency radar might be able to remove some ambiguities that were encountered in this study.

Weinman, J. A.↗

Attenuation statistics at 20.6, 31.65 and 52.85 GHz derived from emission measurements by ground-based microwave radiometers

Two seasons (December 1987 to February 1988 and July 1988 to September 1988) of thermal emission measurements, taken by a multichannel ground-based microwave radiometer, are used to derive single-station zenith attenuation statistics at 20.6 and 31.65 GHz. For the summer period, statistics are also derived at 52.85 GHz. In addition, data from two radiometers located 50 km apart are used to derive two-station attenuation diversity statistics at 20.6 and 31.65 GHz. The multichannel radiometer was operated at Denver, Colorado, U.S. and the dual-channel device was operated at Platteville, Colorado. The diversity statistics are presented by cumulative distributions and by bivariate frequency distributions. The frequency distributions are analyzed when either one or both stations have liquid clouds.

Fionda, E.↗

Ground and in-flight calibrations for the Earth Radiation Budget Experiment (ERBE) nonscanning radiometers

This paper describes the algorithms and procedures used for in-flight calibration of the nonscanning radiometers used in the Earth Radiation Budget Experiment (ERBE) instruments. The computation of the count conversion coefficients used in the basic ERBE radiometric equations is described, as well as the determination of the offsets and time-dependent coefficients used to account for the in-flight changes in the radiometers. The calibration results for more than 5 years of ERBE data are summarized for all nonscanning radiometers. Discontinuities in the observed data, and the effects of these discontinuities are discussed. Applications of ERBE type calibration algorithms to the EOS/CERES platforms are suggested.

Paden, Jack↗

DSS-13 26-meter antenna upgraded radiometer system

The Deep Space Station (DSS)-13 26-m antenna radiometer system was upgraded with an IBM-compatible computer-controlled configuration with improved supporting hardware and software. Software was generated to analyze results and correct for antenna mispointing, tropospheric loss, and other observing errors. This total power radiometer configuration provides a prototype for the new DSS-13 34-m antenna. The radiometer system is described in terms of the theory, instrumentation hardware, computer configuration, and operational features and performance. The system is used to obtain antenna efficiency and pointing model data and is useful for radio source calibrations required for radio astronomy. Some recent results are given.

Stelzried, C. T.↗

Thermistor bolometer scanning radiometer - Applications and flight experience

Scanning radiometers aboard both high-altitude sun-synchronous polar orbit and low altitude equatorial orbit spacecraft have conducted measurements of the earth's long-wave radiation. Attention is presently given to the Earth Radiation Budget Satellite Experiment instruments, which are designed to measure earth radiance with an absolute radiometric error of less than 1 percent. The scanner instruments consists of three broadband radiometer channels employing thermistor bolometers as sensing elements; these radiometers repeatedly scan the earth from limb to limb every 4 sec, generating contiguous pixels on the earth's surface.

Kopia, Leonard P.↗

Tropical Rainfall Measuring Mission (TRMM) project. VI - Spacecraft, scientific instruments, and launching rocket. Part 3 - The electrically Scanning Microwave Radiometer and the Special Sensor Microwave/Imager

The two microwave radiometers for TRMM are designed to measure thermal microwave radiation upwelling from the earth. The Electrically Scanning Microwave Radiometer (ESMR) scans from 50 deg to the left through nadir to 50 deg to the right in 78 steps with no moving mechanical parts in a band centered at 19.35 GHz. The TRMM concept uses the radar to develop a climatology of rain-layer thickness which can be used for the interpretation of the radiometer data over a swath wider than the radar. The ESMR data are useful for estimating rain intensity only over an ocean background. The Special Sensor Microwave/Imager (SSM/I), which scans conically with three dual polarized channels at 19, 37, and 85 GHz and a single polarized channel at 22 GHz, provides a wider range of rainfall intensities. The SSM/I spins about an axis parallel to the local spacecraft vector and 128 uniformly spaced samples of the 85 GHz data are taken on each scan over a 112-deg scan region simultaneously with 64 samples of the other frequencies.

Wilheit, Thomas T.↗

High altitude airborne remote sensing mission using the advanced microwave precipitation radiometer (AMPR)

The advanced microwave precipitation radiometer (AMPR) is an airborne multichannel imaging radiometer used to better understand how the earth's climate structure works. Airborne data results from the October 1990 Florida thunderstorm mission in Jacksonville, FL, are described. AMPR data on atmospheric precipitation in mesoscale storms were retrieved at 10.7, 19.35, 37.1, and 85.5 GHz onboard the ER-2 aircraft at an altitude of 20 km. AMPR's three higher-frequency data channels were selected to operate at the same frequencies as the spaceborne special sensor microwave/imager (SSM/I) presently in orbit. AMPR uses two antennas to receive the four frequencies: the lowest frequency channel uses a 9.7-in aperture lens antennas, while the three higher-frequency channels share a separate 5.3-in aperture lens antenna. The radiometer's temperature resolution performance is summarized.

Galliano, J.↗

A millimeter-wave radiometer for detecting microbursts

This paper describes a millimeter-wave radiometer for the detection of wind shear from airborne platforms or at airport terminals. This proposed instrument will operate near the group of atmospheric oxygen absorptions centered near 60 GHz, which it will use to sense temperature from a distance. The instrument will use two channels to provide two different temperature measurements, providing the basis for solution of two equations in two unknowns, which are range to the wind shear plume and its temperature. A third channel will measure ambient atmospheric temperature. Depending on the temperature difference between the wind-shear plume and ambient, the standard deviation of range measurement accuracy is expected to be about 1 km at 5 km range, while the temperature measurement standard deviation will be about one-fourth the temperature difference between plume and ambient at this range. The instrument is expected to perform usefully at ranges up to 10 km, giving adequate warning of the presence of wind shear even for high performance jet aircraft. Other atmospheric hazards which might be detected by this radiometer include aircraft wakes and vortices, clear-air turbulence, and wind rotors, although the latter two phenomena would be detected by an airborne version of the instrument. A separate radiometer channel will be provided in the proposed instrument to detect aircraft wakes and vortices based on perturbation of the spectrum of microscopic atmospheric temperature fluctuations caused by the passage of large aircraft.

Mcmillan, Robert↗

Comparison of column water vapor measurements using downward-looking near-infrared and infrared imaging systems and upward-looking microwave radiometers

Remote soundings of precipitable water vapor from three systems are compared with each other and with ground truth from radiosondes. Ancillary data from a mesoscale network of surface observing stations and from wind-profiling radars are also used in the analysis. The three remote-sounding techniques are: (a) a reflectance technique using spectral data collected by the Airborne Visible-Infrared Imaging Spectrometer; (b) an emission technique using Visible-Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) data acquired from the NOAA's GOES; and (c) a microwave technique using data from a limited network of three ground-based dual-channel microwave radiometers. The data were taken over the Front Range of eastern Colorado on 22-23 March 1990. The generally small differences between the three types of remote-sounding measurements are consistent with the horizontal and temporal resolutions of the instruments. The microwave and optical reflectance measurements agreed to within 0.1 cm; comparisons of the microwave data with radiosondes were also either as good or explainable. The largest differences between the VAS and the microwave radiometer at Elbert were between 0.4 and 0.5 cm and appear to be due to variable terrain within the satellite footprint.

Gao, Bo-Cai↗

Calibrated intercepts for solar radiometers used in remote sensor calibration

Calibrated solar radiometer intercepts allow spectral optical depths to be determined for days with intermittently clear skies. This is of particular importance on satellite sensor calibration days that are cloudy except at the time of image acquisition. This paper describes the calibration of four solar radiometers using the Langley-Bouguer technique for data collected on days with a clear, stable atmosphere. Intercepts are determined with an uncertainty of less than six percent, corresponding to a maximum uncertainty of 0.06 in optical depth. The spread of voltage intercepts calculated in this process is carried through three methods of radiometric calibration of satellite sensors to yield an uncertainty in radiance at the top of the atmosphere of less than one percent associated with the uncertainty in solar radiometer intercepts for a range of ground reflectances.

Gellman, David I.↗

Spatial variability of summer Florida precipitation and its impact on microwave radiometer rainfall-measurement systems

Three-dimensional radar data for three summer Florida storms are used as input to a microwave radiative transfer model. The model simulates microwave brightness observations by a 19-GHz, nadir-pointing, satellite-borne microwave radiometer. The statistical distribution of rainfall rates for the storms studied, and therefore the optimal conversion between microwave brightness temperatures and rainfall rates, was found to be highly sensitive to the spatial resolution at which observations were made. The optimum relation between the two quantities was less sensitive to the details of the vertical profile of precipitation. Rainfall retrievals were made for a range of microwave sensor footprint sizes. From these simulations, spatial sampling-error estimates were made for microwave radiometers over a range of field-of-view sizes. The necessity of matching the spatial resolution of ground truth to radiometer footprint size is emphasized. A strategy for the combined use of raingages, ground-based radar, microwave, and visible-infrared (VIS-IR) satellite sensors is discussed.

Turner, B. J.↗