Search NASA⌕ Search

SEARCH · Search NASA

Results for “Random vibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Integrated Structural Analysis and Test Program

An integrated structural-analysis and structure-testing computer program is being developed in order to: Automate repetitive processes in testing and analysis; Accelerate pre-test analysis; Accelerate reporting of tests; Facilitate planning of tests; Improve execution of tests; Create a vibration, acoustics, and shock test database; and Integrate analysis and test data. The software package includes modules pertaining to sinusoidal and random vibration, shock and time replication, acoustics, base-driven modal survey, and mass properties and static/dynamic balance. The program is commanded by use of ActiveX controls. There is minimal need to generate command lines. Analysis or test files are selected by opening a Windows Explorer display. After selecting the desired input file, the program goes to a so-called analysis data process or test data process, depending on the type of input data. The status of the process is given by a Windows status bar, and when processing is complete, the data are reported in graphical, tubular, and matrix form.

Kaufman, Daniel↗

Vibration Test Demonstrated Dynamic Capability of an Operating Stirling Convertor

The NASA Glenn Research Center and the U.S. Department of Energy are currently developing a high-efficiency, long-life, free piston Stirling convertor for use as an advanced spacecraft power system for future NASA missions. As part of this development, a Stirling Technology Demonstrator Converter (TDC), developed by Stirling Technology Company for the Department of Energy, was vibration tested at Glenn's Structural Dynamics Laboratory in November and December 1999. This testing demonstrated that the Stirling TDC is able to withstand the harsh random vibration (20 to 2000 Hz) seen during a typical spacecraft launch and to survive with no structural damage or functional power performance degradation, thereby enabling its use in future spacecraft power systems. Glenn and Stirling personnel conducted tests on a single 55 We TDC. The purpose was to characterize the TDC's structural response to vibration and to determine if the TDC could survive the vibration criteria established by the Jet Propulsion Laboratory for launch environments. The TDC was operated at full-stroke and full power conditions during the vibration testing.

Hughes, William O.↗

Motion and force controlled vibration testing

A technique for controlling both the input acceleration and force in vibration tests is proposed to alleviate the overtesting risks and the problems associated with response limiting in conventional vibration tests of aerospace hardware. Previous research on impedance and force controlled vibration tests is reviewed and a simple equation governing the dual control of acceleration and force is derived. A practical method for implementing the dual control technique in random vibration tests has been demonstrated in JPL's environmental test facility using a conventional digital controller operating in the extremal mode. The dual control technique provides appropriate real-time notching of the input acceleration and a corresponding reduction of the test item response at resonances. Issues concerning the need for force and acceleration phase information, the adequacy of specifying the blocked force, and the derivation of the total force for multipoint supports are discussed.

Scharton, Terry D.↗

Magnetic control assembly reports

Results are summarized of the qualification level vibration tests performed on the magnet control assembly (MCA) for Nimbus and ERTS satellites. The MCA electronics and probe units have demonstrated the capability to survive qualification sinusoidal and random vibration levels. The functional testing indicated normal operation of the units after each axis of vibration. Visual inspection indicated no evidence of degradation. Post vibration acceptance testing verified normal operation of the MCA.

Stickler, A. C.↗

Design and dynamic testing of an instrumented spacecraft component

Details relating to the design and subsequent vibration and shock tests of a spacecraft component for a severe vibration and shock environment are presented. The design process and analysis method involve the use of finite element analysis coupled with the Modal Strain Energy method with risk graphs to determine the adequacy of the design. The vibration levels experienced by box parts are reduced by the application of passive constrained layer viscoelastic treatments that significantly improve component reliability. All significant internal components were fully instrumented in both the random vibration and shock tests, the latter being done on a mechanical impact pyro simulator. Correlation between analysis and test data is good, validating the modeling and analysis techniques.

Dwyer, Thomas J.↗

Force Measurements in Vibration and Acoustic Tests

The advent of triaxial, piezoelectric force gages and the associated signal processing is a precursor to several dynamics testing innovations. This new technology is applicable to spacecraft programs that JPL manages. An application of force measurement is force limiting (when testing spacecraft in random vibration tests). Base-drive and acoustic modal testing is a potential application.

vibration tests acoustic tests spacecraft testing ↗

Digital vibration control techniques

Analog vibration control techniques are reviewed and are compared with digital techniques. The advantages of the digital methods over the analog methods are demonstrated. The following topics are covered: (1) methods of computer-controlled random vibration and reverberation acoustic testing; (2) methods of computer-controlled sinewave vibration testing; and (3) methods of computer-controlled shock testing. Basic concepts are stressed rather than specific techniques or equipment. General algorithms are described in the form of block diagrams and flow diagrams. Specific problems and potential problems are discussed. The material is computer sciences oriented but is kept at a level that facilitates an understanding of the basic concepts of computer-controlled induced environmental test systems.

Chapman, P.↗

Vibration and Acoustic Testing for Mars Micromission Spacecraft

The objective of the Mars Micromission program being managed by the Jet Propulsion Laboratory (JPL) for NASA is to develop a common spacecraft that can carry telecommunications equipment and a variety of science payloads for exploration of Mars. The spacecraft will be capable of carrying robot landers and rovers, cameras, probes, balloons, gliders or aircraft, and telecommunications equipment to Mars at much lower cost than recent NASA Mars missions. The lightweight spacecraft (about 220 Kg mass) will be launched in a cooperative venture with CNES as a TWIN auxiliary payload on the Ariane 5 launch vehicle. Two or more Mars Micromission launches are planned for each Mars launch opportunity, which occur every 26 months. The Mars launch window for the first mission is November 1, 2002 through April 2003, which is planned to be a Mars airplane technology demonstration mission to coincide with the 100 year anniversary of the Kittyhawk flight. Several subsequent launches will create a telecommunications network orbiting Mars, which will provide for continuous communication with lenders and rovers on the Martian surface. Dedicated science payload flights to Mars are slated to start in 2005. This new cheaper and faster approach to Mars exploration calls for innovative approaches to the qualification of the Mars Micromission spacecraft for the Ariane 5 launch vibration and acoustic environments. JPL has in recent years implemented new approaches to spacecraft testing that may be effectively applied to the Mars Micromission. These include 1) force limited vibration testing, 2) combined loads, vibration and modal testing, and 3) direct acoustic testing. JPL has performed nearly 200 force limited vibration tests in the past 9 years; several of the tests were on spacecraft and large instruments, including the Cassini and Deep Space One spacecraft. Force limiting, which measures and limits the spacecraft base reaction force using triaxial force gages sandwiched between the spacecraft and the test fixture, alleviates the severe overtest at spacecraft resonances inherent in rigid fixture vibration tests. It has the distinct advantage over response limiting that the method is not dependent on the accuracy of a detailed dynamic model of the spacecraft. Combined loads, vibration, and modal testing were recently performed on the QuikSCAT spacecraft. The combined tests were performed in a single test setup per axis on a vibration shaker, reducing test time by a factor of two or three. Force gages were employed to measure the true c.g. acceleration of the spacecraft for structural loads verification using a sine burst test, to automatically notch random vibration test input accelerations at spacecraft resonances based on predetermined force limits, and to directly measure modal masses in a base drive modal test. In addition to these combined tests on the shaker, the QuikSCAT spacecraft was subjected to a direct field acoustic test by surrounding the spacecraft, still on the vibration shaker, with rock concert type acoustic speakers. Since the spacecraft contractor does not have a reverberant field acoustic test facility, performing a direct field acoustic test -saved the program nearly two weeks schedule time that would have been required for packing / unpacking and shipping of the spacecraft. This paper discusses the rationale behind and advantages of the above test approaches and provides examples of their actual implementation and comparisons to flight data. The applicability of the test approaches to Mars Micromission spacecraft qualification is discussed.

Kern, Dennis L.↗

Space shuttle OMS helium regulator design and development

Analysis, design, fabrication and design verification testing was conducted on the technological feasiblity of the helium pressurization regulator for the space shuttle orbital maneuvering system application. A prototype regulator was fabricated which was a single-stage design featuring the most reliable and lowest cost concept. A tradeoff study on regulator concepts indicated that a single-stage regulator with a lever arm between the valve and the actuator section would offer significant weight savings. Damping concepts were tested to determine the amount of damping required to restrict actuator travel during vibration. Component design parameters such as spring rates, effective area, contamination cutting, and damping were determined by test prior to regulator final assembly. The unit was subjected to performance testing at widely ranging flow rates, temperatures, inlet pressures, and random vibration levels. A test plan for propellant compatibility and extended life tests is included.

Wichmann, H.↗

Automobile ride quality experiments correlated to iso-weighted criteria

As part of an overall study to evaluate the usefulness of ride quality criteria for the design of improved ground transportation systems an experiment was conducted involving subjective and objective measurement of ride vibrations found in an automobile riding over roadways of various roughness. Correlation of the results led to some very significant relationships between passenger rating and ride accelerations. The latter were collapsed using a frequency-weighted root mean square measure of the random vibration. The results suggest the form of a design criterion giving the relationship between ride vibration and acceptable automobile ride quality. Further the ride criterion is expressed in terms that relate to rides with which most people are familiar. The design of the experiment, the ride vibration data acquisition, the concept of frequency weighting and the correlations found between subjective and objective measurements are presented.

Healey, A. J.↗

Dynamic Capability of an Operating Stirling Convertor

The NASA John H. Glenn Research Center and the US Department of Energy are currently developing a Stirling convertor for use as an advanced spacecraft power system for future NASA deep-space missions. NASA Headquarters has recently identified the Stirling technology generator for potential use as the spacecraft power system for two of NASA's new missions, the Europa Orbiter and the Solar Probe missions (planned for launch in 2006 and 2007 respectively). As part of the development of this power system, a Stirling Technology Demonstration Convertor was vibration tested at NASA John H. Glenn Research Center to verify its survivability and capability of withstanding the harsh dynamic environment typically seen by the spacecraft when it is launched by an expendable launch vehicle. The Technology Demonstration Convertor was fully operational (producing power) during the random vibration testing. The output power of the convertor and other convertor performance indicators were measured during the testing, and these results are discussed in this paper. Numerous accelerometers and force gauges also were used to provide information on the dynamic characteristics of the Technology Demonstration Convertor and as an indication of any possible damage due to the vibration. These measurements will also be discussed in this paper. The vibration testing of the Stirling Technology Demonstration Convertor was extremely successful. The Technology Demonstration Convertor survived all its vibration testing with no structural damage or functional performance degradation. As a result of this testing, the Stirling convertor's capability to withstand vibration has been demonstrated, enabling its usage in future spacecraft power systems.

Goodnight, Thomas W.↗

(abstract) Vibration Damping of the Cassini Spacecraft Structure

Cassini will be protected during launch ascent through the atmosphere by a lightweight aluminum payload fairing (PLF). As a result of the extreme noise levels generated by the powerful Titan IV at liftoff, and the acoustic transparency of the PLF, Cassini is predicted to experience severe acoustic levels. Furthermore, the high acoustic levels, coupled with the size and configuration of the spacecraft, will induce intense random vibration on the structure and critical spacecraft components. Efforts to mitigate the vibroacoustic environment by modifying the spacecraft structure were pursued. Preliminary studies indicated that a structural damping treatment using viscoelastic materials (VEMs) represented a viable technique of reducing vibration with minimum impact on weight, cost, and redesign. Tuned Vibration Absorbers (TVAs) - compact, single degree-of-freedom mechanical oscillators in which a VEM serves as the spring and damping element - will be used also. The operating principles, design, and installation of the TVAs are described, the test program is outlined, and test results are presented which show that significant vibration attenuation was achieved.

vibroacoustic environment↗

Hypogravity's Effect on the Life Cycle of Japanese Quail

A series of studies were conducted to determine the effect of activities preceding space-flight and during space-flight on quail embryonic development. While the overall development of the quail embryos was evaluated, the report presented herein, focused on calcium utilization or uptake from eggshells by developing embryos during incubation in space and on earth. In the pre-space trials, fertilized quail eggs were subjected to pre-night dynamics including forces of centrifugation, vibration, or a combination of vibration and centrifugation prior to incubation for 6 or 16 days. In another trial, fertile quail eggs were tested for survivability in a refrigerator stowage kit for eggs (RSKE) which was subsequently used to transport the eggs to space. Eggs in the RSKE were subjected to shuttle launch dynamics including G force and random vibration profiles. In the space- flight trials, 48 fertile quail eggs were launched on space shuttle Flight STS-76 and were subsequently incubated in a Slovakian incubator onboard space station, MIR. Two sets of ground controls each with 48 fertile eggs with and without exposure to launch dynamics were initiated 5 days post-launch. There was a laboratory control (incubated in Lyon RX2 incubator at 37.5 C) and a synchronous control (incubated in Lyon RX2 incubator at 39 - 400 C), which simulated the temperature of the space-flight incubator. Following space-flight trials, post-flight trials were conducted where quail eggs were incubated in Lyon RX2 or Slovakian incubators under various temperatures with or without launch dynamics. Eggshells from all study trials were retrieved and analyzed for calcium content to determine if its utilization by developing quail embryos was affected by activities preceding space-flight or during incubation in space under microgravity. Results from the pre-flight and post-flight showed that pre-flight activities and shuttle launch dynamics had no effect on calcium uptake from the eggshell by developing embryos. However, calcium uptake from the eggshell by developing embryos incubated in micro,aravity was impaired by 12.6% when compared to embryos incubated on earth under laboratory control environment. This impairment was unlikely due to factors other than microgravity. In general, calcium utilization by developing embryos increased with age of incubation with the most increase occurring at day 16 of incubation.

Hester, Patricia Y.↗

Simulation efficiency in acoustic testing of Shuttle payloads

Comparative evaluations of payload vibration responses from ground acoustic tests and Shuttle flights of several payloads indicate that ground acoustic testing will generally underestimate the Shuttle flight vibrational response of a payload, particularly in the low frequency range. This underestimation is found to be primarily due to the lack of simulation during the acoustic test of the in-flight mechanical energy transmission normally transmitted through the Orbiter-payload structural interface. It is suggested that test efficiency corrections be applied when developing random vibration criteria based on ground acoustic test data.

On, Frank J.↗

A Method for Implementing Force-Limited Vibration Control

NASA/GSFC has implemented force-limited vibration control on a controller which can only accept one profile. The method uses a personal computer based digital signal processing board to convert force and/or moment signals into what appears to he an acceleration signal to the controller. This technique allows test centers with older controllers to use the latest force-limited control techniques for random vibration testing. The paper describes the method, hardware, and test procedures used. An example from a test performed at NASA/GSFC is used as a guide.

Worth, Daniel B.↗

Vibration Testing of Electrical Cables to Quantify Loads at Tie-Down Locations

The standard method for defining static equivalent structural load factors for components is based on Mile s equation. Unless test data is available, 5% critical damping is assumed for all components when calculating loads. Application of this method to electrical cable tie-down hardware often results in high loads, which often exceed the capability of typical tie-down options such as cable ties and P-clamps. Random vibration testing of electrical cables was used to better understand the factors that influence component loads: natural frequency, damping, and mass participation. An initial round of vibration testing successfully identified variables of interest, checked out the test fixture and instrumentation, and provided justification for removing some conservatism in the standard method. Additional testing is planned that will include a larger range of cable sizes for the most significant contributors to load as variables to further refine loads at cable tie-down points. Completed testing has provided justification to reduce loads at cable tie-downs by 45% with additional refinement based on measured cable natural frequencies.

Dutson, Joseph D.↗

Validation of a Deterministic Vibroacoustic Response Prediction Model

This report documents the recently completed effort involving validation of a deterministic theory for the random vibration problem of predicting the response of launch pad structures in the low-frequency range (0 to 50 hertz). Use of the Statistical Energy Analysis (SEA) methods is not suitable in this range. Measurements of launch-induced acoustic loads and subsequent structural response were made on a cantilever beam structure placed in close proximity (200 feet) to the launch pad. Innovative ways of characterizing random, nonstationary, non-Gaussian acoustics are used for the development of a structure's excitation model. Extremely good correlation was obtained between analytically computed responses and those measured on the cantilever beam. Additional tests are recommended to bound the problem to account for variations in launch trajectory and inclination.

Caimi, Raoul E.↗