Balancing Interfacial Reactions to Achieve Long Cycle Life in High Energy Lithium Metal Batteries

Rechargeable lithium (Li) metal batteries have attracted wide attentions as the next generation energy storage technologies. However, simultaneously achieving high cell-level energy density and long cycle life in realistic batteries is still a great challenge. Here we investigate the cell degradation mechanisms of Li||LiNi0.6Mn0.2Co0.2O2 pouch cells using different, but representative cell configurations to understand the fundamental linkage among Li thickness, electrolyte depletion and the structure evolution of solid electrolyte interphase (SEI) layers. Different cell failure modes were discovered when tuning the anode to cathode capacity (N/P) ratio in compatible electrolyte. With a thick-Li anode (N/P ratio = 2.5), initial stable cycling is obtained because of the abundant Li supply from the anode together with an artificially inflated high Coulombic Efficiency, followed by a premature sudden cell death appears due to the enrichment of “ineffective SEI” which does not participate in the electrochemical reactions but keep increasing cell impedance. The anode-free cell (N/P 0:1) displays a steady capacity decay because cathode Li loss dominates from the beginning to the end of cell cycle life. An optimized thin-Li (N/P 1:1) well balances the Li consumption rate with the impedance buildup by minimizing the growth of ineffective SEI layer, thus decelerates cell polarization increasing and extends cycling. Contrary to conventional wisdoms, long cycle life is observed by using ultra thin-Li (20 µm) in balanced cells. A prototype 350 Wh kg-1 pouch cell (2.0 Ah) achieves over 600 long stable cycles with 76% capacity retention without sudden cell death.

Niu, Chaojiang↗

Molecular and Dual-Isotopic Profiling of the Microbial Controls on Nitrogen Leaching in Agricultural Soils under Managed Aquifer Recharge

Nitrate (NO 3 – ) leaching is a serious health and ecological concern in global agroecosystems, particularly those under the application of agricultural-managed aquifer recharge (Ag-MAR); however, there is an absence of information on microbial controls affecting NO 3 – leaching outcomes. We combine natural dual isotopes of NO 3 – ( 15 N/ 14 N and 18 O/ 16 O) with metagenomics, quantitative polymerase chain reaction (PCR), and a threshold indicator taxa analysis (TITAN) to investigate the activities, taxon profiles, and environmental controls of soil microbiome associated with NO 3 – leaching at different depths from Californian vineyards under Ag-MAR application. The isotopic signatures demonstrated a significant priming effect (P < 0.01) of Ag-MAR on denitrification activities in the topsoil (0–10 cm), with a 12–25-fold increase of 15 N–NO 3 – and 18 O–NO 3 – after the first 24 h of flooding, followed by a sharp decrease in the enrichment of both isotopes with ~80% decline in denitrification activities thereafter. In contrast, deeper soils (60–100 cm) showed minimal or no denitrification activities over the course of Ag-MAR application, thus resulting in 10–20-fold of residual NO 3 – being leached. Metagenomic profiling and laboratory microcosm demonstrated that both nitrifying and denitrifying groups, responsible for controlling NO 3 – leaching, decreased in abundance and potential activity rates with soil depth. TITAN suggested that Nitrosocosmicus and Bradyrhizobium, as the major nitrifier and denitrifier, had the highest and lowest tipping points with regard to the NO 3 – changes (P < 0.05), respectively. Overall, our study provides new insight into specific depth limitations of microbial controls on soil NO 3 – leaching in agroecosystems.

59 BASIC BIOLOGICAL SCIENCES↗

Model-Instructed Design of Novel Charging Protocols for the Extreme Fast Charging of Lithium-Ion Batteries Without Lithium Plating

Relatively long recharge time of high-energy density lithium-ion batteries (LIBs) is one of the major obstacles to the widespread deployment of electric vehicles (EVs). Excessive fast charge of LIBs can cause severe safety issues, the most significant of which is lithium plating. In addition to the consumption of cyclable lithium, dendrite-like lithium plating can cause short-circuiting within the cell, which could lead to catastrophic failure. In addition to the developments of advanced electrolytes, active materials and electrodes, the fast charging capability of LIBs can be improved by using optimized charging protocol. In this paper, the Pseudo2D battery model is first used to screen some conventional charging protocols proposed for fast charging, including the constant-current constant-voltage charging (CCCV), constant-power constant-voltage charging (CPCV), multi-stage constant-current charging, and pulse current charging. A semi-optimal charging protocol is then developed by automatically modifying the charge current such that the cell is charged at close-to-maximum current without lithium plating. Based on the features of the semi-optimal protocol, two practical novel fast charging protocols are proposed which allow charging the cell at a higher rate without lithium plating. Through simulation, we show that the no-plating capacity after 10 min charge can be improved by up to ~10.7% compared to CCCV charging for a 2.5 mAh cm -2 cell and ~18.8% for a 4 mAh cm -2 cell, when the proposed charging protocols are used.

25 ENERGY STORAGE↗

Self-supported MoO 2 /MoS 2 nano-sheets embedded in a carbon cloth as a binder-free substrate for high-energy lithium–sulfur batteries

As one of the most prospective candidates for next-generation rechargeable batteries, lithium-sulfur (Li-S) batteries currently still encounter great challenges associated with the low conductivity, severe shuttle effects, and sluggish redox kinetics. Herein, a self-supported sulfur host is fabricated by an in-situ growth of MoO 2 /MoS 2 nano-sheets on a carbon cloth (CC). First, carbon cloth serves as a good template for the morphology-controlled synthesis of nanostructured materials, which not only alleviates the agglomeration of MoO2/MoS2, but also enhances the flexibility and mechanical strengthen of the hybrid architecture as a free-standing host. Second, the polysulfide-trapping ability can be greatly enhanced by both physical and chemical adsorption from the MoO 2 /MoS 2 -anchored carbon cloth. Moreover, the partially sulfurized MoO 2 /MoS 2 nano-sheets integrate the benefits of conductive MoO 2 and sulfiphilic MoS 2 , thus facilitating fast charge transfer and redox kinetics of polysulfide conversion. As a result, these attributes enable the host to hold a high sulfur loading (up to 7.6 mg cm -2 ), which exceeds most of the reported carbon cloth-related cathode work in the literature. Furthermore, the Li-S cells can achieve a high peak capacity of 1350 mA h g -1 , excellent rate capability (C/20 - 2C rate), impressive areal capacity (up to 6.3 mA h cm -2 ), and a high capacity retention of 85% after 100 cycles.

25 ENERGY STORAGE↗

Advanced strategies for the development of porous carbon as a Li host/current collector for lithium metal batteries

Lithium metal is considered a promising anode material for high-energy-density rechargeable batteries because of its high specific theoretical capacity (3860 mAh g -1 , low mass density (0.534 g cm -3 ), and low electrochemical redox potential (-3.04 V vs. the standard hydrogen electrode). However, the high reactivity of Li with the electrolyte leads to the formation of an unstable solid electrolyte interphase (SEI) and continuous side reactions. Also, the non-uniform lithium-ion flux and infinite volume expansion of Li metal cause the growth of Li dendrites. These pose significant safety challenges and cause rapid capacity fading of the lithium metal batteries (LiMBs). To resolve these issues, a low-cost, easily processed, lightweight, high-performance carbon-based porous matrix is considered promising to host Li metal deposition. The three-dimensional (3D) porous nano/microstructured carbon provides sufficient space for Li accommodation during Li plating, buffers the volume changes during Li plating/stripping, and lowers the effective current density contributing to dendrite-free Li deposition. Besides, the outstanding electrochemical and mechanical stability, flexibility and the high electronic conductivity enable the nano/microstructured carbon to serve as both Li host and current collector. The development of 3D carbon/Li composite by mechanical roll-press techniques not only eliminates the complex and risky procedure of making carbon/Li composite based on Li plating or molten Li infusion but also stabilizes the capacity at higher Li plating/stripping rates. Recently, there is an advancement in the lithiophilic decorations of 3D structure to introduce sufficient nucleation sites and the development of artificial SEI on top of the 3D matrix to suppress Li dendrite formation. Such 3D structural modifications create a uniform electric field, lower the Li nucleation overpotential, provide strong mechanical and chemical stability, and stabilize the interface thereby inhibiting the degradation of lithium and the electrolyte. Here we summarize the research progress on porous carbon/Li composites in terms of materials type, structure, fabrication technique, their electrochemical battery performance, and identify the critical challenges that need to be addressed for high-energy-density practical LiMBs.

25 ENERGY STORAGE↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗