Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Creation of a Full-Core HTR Benchmark with the Fort St. Vrain Initial Core and Assessment of Uncertainties in the FSV Fuel Composition and Geometry

Information and measured data from the intial Fort St. Vrain (FSV) high temperature gas reactor core is used to develop a benchmark configuration to validate computational methods for analysis of a full-core, commercial HTR configuration. Large uncertainties in the geometry and composition data for the FSV fuel and core are identified, including: (1) the relative numbers of fuel particles for the four particle types, (2) the distribution of fuel kernel diameters for the four particle types, (3) the Th:U ratio in the initial FSV core, (4) and the buffer thickness for the fissile and fertile particles. Sensitivity studies were performed to assess each of these uncertainties. A number of methods were developed to assist in these studies, including: (1) the automation of MCNP5 input files for FSV using Python scripts, (2) a simple method to verify isotopic loadings in MCNP5 input files, (3) an automated procedure to conduct a coupled MCNP5-RELAP5 analysis for a full-core FSV configuration with thermal-hydraulic feedback, and (4) a methodology for sampling kernel diameters from arbitrary power law and Gaussian PDFs that preserved fuel loading and packing factor constraints. A reference FSV fuel configuration was developed based on having a single diameter kernel for each of the four particle types, preserving known uranium and thorium loadings and packing factor (58%). Three fuel models were developed, based on representing the fuel as a mixture of kernels with two diameters, four diameters, or a continuous range of diameters. The fuel particles were put into a fuel compact using either a lattice-bsed approach or a stochastic packing methodology from RPI, and simulated with MCNP5. The results of the sensitivity studies indicated that the uncertainties in the relative numbers and sizes of fissile and fertile kernels were not important nor were the distributions of kernel diameters within their diameter ranges. The uncertainty in the Th:U ratio in the intial FSV core was found to be important with a crude study. The uncertainty in the TRISO buffer thickness was estimated to be unimportant but the study was not conclusive. FSV fuel compacts and a regular FSV fuel element were analyzed with MCNP5 and compared with predictions using a modified version of HELIOS that is capable of analyzing TRISO fuel configurations. The HELIOS analyses were performed by SSP. The eigenvalue discrepancies between HELIOS and MCNP5 are currently on the order of 1% but these are still being evaluated. Full-core FSV configurations were developed for two initial critical configurations - a cold, clean critical loading and a critical configuration at 70% power. MCNP5 predictions are compared to experimental data and the results are mixed. Analyses were also done for the pulsed neutron experiments that were conducted by GA for the initial FSV core. MCNP5 was used to model these experiments and reasonable agreement with measured results has been observed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CMIP6-based Multi-model Streamflow Projections over the Conterminous US

This dataset presents an ensemble of streamflow projections based on the hydroclimate projections dataset supporting the SECURE Water Act Section 9505 Assessment for the US Department of Energy (DOE) Water Power Technologies Office (WPTO). The six-member General Climate Model (GCM) ensemble from the Coupled Models Intercomparison Project phase 6 (CMIP6) downscaled using statistical (i.e., DBCCA) and dynamical (i.e., RegCM) and bias-corrected using two meteorological reference observations (Daymet & Livneh) are driven through two calibrated hydrologic models (VIC & PRMS) to simulate projected future hydrologic responses. This leads to the production of an ensemble of hydroclimate projections, including total runoff (surface runoff and baseflow) for 1980–2019 baseline and 2020–2059 near-term future periods under multiple emission scenarios at 1/24° (~4 km) spatial resolution across the CONUS. The total runoff projections are routed through the Routing Application for Parallel computatIon of Discharge (RAPID) routing model to produce an ensemble of streamflow projections for both periods across 2.7 million NHDPlusV2 stream reaches in the CONUS.

13 HYDRO ENERGY↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

NGEE Arctic Phase 4 Plant Functional Type Framework for Pan-Arctic Vegetation

The NGEE-Arctic research team identified a common set of hierarchical plant functional types (PFTs) for pan-arctic vegetation that we will use across our research activities. Interdisciplinary work within a large team requires agreement regarding levels of functional organization so that knowledge, data, and technologies can be shared and combined effectively. The team has identified plant functional types as a crucial area where such interoperability is needed. PFTs are used to represent plant pools and fluxes within models, summarize observational data, and map vegetation across the landscape. Within each of these applications, varying levels of PFT specificity are needed according to the specific scientific research goal, computational limitations, and data availability. By agreeing on a specific hierarchical framework for grouping variables in our vegetation data, we ensure the resulting research products will be robust, flexible, and scalable. In this document, we lay out the agreed upon PFT framework with definitions and references to existing literature. Table 1 included in the "NGA700_Phase4PFTFramework_about*" file outlines the relationship between NGEE-Arctic Phase 4, Tier 1 PFTs and the PFTs used within prominent arctic literature as well as publications by the NGEE-Arctic team during phases 1-3.This dataset consists of a table detailing a hierarchical PFT framework that spans 4 tiers with the most granular PFTs listed in tier 1 and the most general PFTs in tier 4. The PFTs within each tier has a single column in the dataset where the PFTs are named and a separate column where the characteristics used to define that PFT are listed. Grey fill of the cells is used to indicate where a given PFT starts to “lose” tier 1 details as you look from left to right. Note the excel file has merged cells to indicate grouping of PFTs across the Tiers- it will not translate into a delimited filetype (.csv, .txt, etc) without modification thus the hierarchical PFT framework table is available in three different file formats: 1) NGA700_Phase4PTS.xlsx – maintains the merged cells and grey fill; 2) NGA700_Phase4PTS.csv – merged cells are split, and grey fill is removed; 3) NGA700_Phase4PTS.pdf – image of the table with merged cells and grey fill. Metadata document included as a *.pdf and file-level metadata and data dictionary as *.csv files.

54 ENVIRONMENTAL SCIENCES↗

Applicability of Sentinel-1 Terrain Observation by Progressive Scans multitemporal interferometry for monitoring slow ground motions in the San Francisco Bay Area

Data from the Sentinel-1 satellite have already proven useful for investigating seismic and volcanic events since its launch in April 2014. The requirement of ultrahigh coregistration accuracy and the current relatively short time of Sentinel-1 acquisitions make its application challenging for studying slow deformation processes, such as fault creep and land subsidence. Here in this paper we analyze a set of 14 SAR images over the San Francisco Bay Area spanning 1 year from early 2015 to 2016. We show that implementing an existing Enhanced Spectral Diversity algorithm or using precise orbits together with a reference digital elevation model both yield the required coregistration accuracy for making use of the phase measurements in time series analysis of ground deformation. Following a thorough validation test, we update our estimates of Hayward Fault creep rate and confirm uplift due to recharge of the Santa Clara Valley aquifer system during the final summer of 4 year drought.

58 GEOSCIENCES↗

Bias Estimates Used in Lieu of Validation of Fission Products and Minor Actinides in MCNP K eff Calculations for PWR Burnup Credit Casks

The U.S. Nuclear Regulatory Commission (NRC) Division of Spent Fuel Storage and Transportation recently issued Interim Staff Guidance (ISG) 8, Revision 3. This ISG provides guidance for burnup credit (BUC) analyses supporting transport and storage of PWR pressurized water reactor (PWR) fuel in casks. Revision 3 includes guidance for addressing validation of criticality (k eff ) calculations crediting the presence of a limited set of fission products and minor actinides (FP&MA). Based on previous work documented in NUREG/CR-7109, recommendation 4 of ISG-8, Rev. 3, includes a recommendation to use 1.5 or 3% of the FP&MA worth to conservatively cover the bias due to the specified FP&MAs. This bias is supplementary to the bias and bias uncertainty resulting from validation of k eff calculations for the major actinides in SNF and does not address extension to actinides and fission products beyond those identified herein. The work described in this report involves comparison of FP&MA worths calculated using SCALE and MCNP with ENDF/B-V, -VI, and -VII based nuclear data and supports use of the 1.5% FP&MA worth bias when either SCALE or MCNP codes are used for criticality calculations, provided the other conditions of the recommendation 4 are met. The method used in this report may also be applied to demonstrate the applicability of the 1.5% FP&MA worth bias to other codes using ENDF/B V, VI or VII based nuclear data. The method involves use of the applicant s computational method to generate FP&MA worths for a reference SNF cask model using specified spent fuel compositions. The applicant s FP&MA worths are then compared to reference values provided in this report. The applicants FP&MA worths should not exceed the reference results by more than 1.5% of the reference FP&MA worths.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Irradiation Experiment Test Plan

This document presents the test plan for the AGR-5/6/7 irradiation experiment, the combined fifth, sixth, and seventh irradiations of the United States Department of Energy Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The combined irradiation tests will consist of fuel qualification tests (AGR-5/6) and a margin test (AGR-7) for the industrially produced uranium oxycarbide (UCO) tristructural isotropic (TRISO) coated particle fuel developed by the AGR Program. The objective of the AGR-5/6/7 irradiation experiment is to establish the performance of UCO TRISO fuel fabricated using engineering-scale equipment in a production environment under and beyond normal operating conditions. Specifically, the goals of the AGR 5/6/7 irradiation experiment are: 1. Irradiate reference design fuel containing low-enriched UCO TRISO fuel particles to support fuel qualification. 2. Establish the operating margins for the fuel beyond normal operating conditions. 3. Provide irradiated fuel performance data and irradiated fuel samples for post-irradiation examination and safety testing. 4. Support the refinement of fuel performance and fission product transport models with online, post-irradiation examination and safety test data. In order to achieve the test objectives, the AGR-5/6/7 experiment will be irradiated in the northeast flux trap position of the Advanced Test Reactor at Idaho National Laboratory. The larger diameter of the northeast flux trap provides greater flexibility for test train design, significantly enhancing the capability for the combined irradiations. The test train contains five separate and independently controlled and monitored capsules. The middle capsule contains the AGR 7 margin test fuel. The two bottom and two top capsules contain the AGR 5/6 fuel. Each capsule contains a variable number of fuel compacts filled with UCO TRISO particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THERMAL ANALYSIS OF 3013/9975 CONFIGURATION

The 3013 containers are designed in accordance with the DOE-STD-3013-2004 and are qualified to store plutonium (Pu) bearing materials for 50 years. The U.S. Department of Energy (DOE) certified Model 9975 shipping package is used to transport the 3013 containers to the K-Area Material Storage (KAMS) facility at the Savannah River Site (SRS) and to store the containers until the plutonium can be properly dispositioned. Detailed thermal analyses to support the storage in the KAMS facility are given in References 2, 3, and 4. The analyses in this paper serve to provide non-accident condition, non-bounding, specific 3013 container temperatures for use in the surveillance activities. This paper presents a methodology where critical component temperatures are estimated using numerical methods over a range of package and storage parameters. The analyses include factors such as ambient storage temperature and the content weight, density, heat generation rate, and fill height, that may impact the thermal response of the packages. Statistical methods are used to develop algebraic equations for ease of computations to cover the factor space. All computations were performed in BTU-FT-Hr-{sup o}F units.

42 ENGINEERING↗

Revised Kimberlina Groundwater Simulations

Kimberlina Groundwater Qaulity Simulations (Version 3: 2015 October) by Lawrence Livermore National Labratory. Submitted to the EDX team at the National Energy Technology Laboratory for research use. This dataset contains 562 updated groundwater quality simulations based on the Kimberlina site. It is a six-layer model including the aquifers and aquitards inbetween the ground surface and the reservoir. The input files and associated leakage information for these simulations are included in the zip file "nrap_kim_well31_fluxes and inputs.tar.gz". These 562 simulations are the successful results out of 1000 monte carlo simulations, with time length greater than 5 years. Each simulation consists 6 output files, therefore, there are 3372 files (6*562) in total. One single example simulation of full time length (200 year) is also provided in the zip file "single_simulation_200yr_sim0012.tar.gz". These 6 groundwater quality parameters are: - pH (use absolute value) - TDS (mg/kg) - Pressure (Pa) - CO2 Liquid Saturation (fraction range 0.0-1.0) - CO2 Gas Concentration (mol/L) - CO2 Liquid Concentration (mol/kg) Their correponding file names, take the first simulation for example, are: ph0001.ntab (for pH) , tds0001.ntab (for TDS), usnt0001.p.ntab (for pressure), usnt0001.s_liquid.ntab (for liquid saturation), usnt0001.c_co2_gas.ntab (for CO2 gas concentration) and usnt0001.c_co2_liquid.ntab (for CO2 liquid concentration). Each output file contains at least 19 columns (variables). The total number of columns depends on the simulation time length. The column data include the information of numerical records, geologic location and sizes and the simulated parameter values over time. The first 13 variables are about numerical records and relative geologic information for a simulation grid: 1. index: simulation index 2. i: the ith grid of x-axis 3. j: the jth grid of y-axis 4. k: the kth grid of z-axis 5. element_ref: element type reference 6. nuft_ind: nuft index 7. x: grid location in the x axis direction 8. y: grid location in the y axis direction 9. z: grid location in the z axis direction 10. dx: grid length in the x axis direction 11. dy: grid length in the y axis direction 12. dz: grid length in the z axis direction 13. volume: volume of the simulation grid The rest (14, 15, 16...) variables are the simulated parameter values over time, take pH as an example, are: 14. ph000y: initial pH value. 15. ph001y: simulated pH value at the end of the 1st year. 16. ph002y: simulated pH value at the end of the 2nd year. ... (and so on)... The zip input files have the input fluxes of brine and CO2 (in kg/s) allocated to model layers 1,2,3 and 5 (layers 4 and 6 are assumed to be no-flow aquitards) through the following nodes: (src1 WELL 7 7 25 25 10 32) #Etchegoin (src2 WELL 7 7 25 25 33 72) #Macoma Chanac (src3 WELL 7 7 25 25 73 83) #Santa Margarita Mclure (src4 WELL 7 7 25 25 84 89) #Fruitvale Round Mountain (aquitard) (src5 WELL 7 7 25 25 90 96) #Olcese Sand (thief zone) (src6 WELL 7 7 25 25 97 99) #tremblor Freeman (aquitard) ex: brn1 is assigned to src 1 from i=(7,7), j=(25,25), k=(10,32) Edited by Ya-Mei Yang at National Energy Technology Laboratory

brine leakage↗

Reference Model 3 Cost Breakdown (RM3: Wave Point Absorber)

Contains the Reference Model 3 (RM3) spreadsheets with the cost breakdown structure (CBS) for the levelized cost of energy (LCOE) calculations for a single RM3 device and multiple unit arrays. These spreadsheets are contained within an XLSX file and a spreadsheet editor such as Microsoft Excel is needed to open the file. This data was generated upon completion of the project on September 30, 2014. The Reference Model Project (RMP), sponsored by the U.S. Department of Energy (DOE), was a partnered effort to develop open-source MHK point designs as reference models (RMs) to benchmark MHK technology performance and costs, and an open-source methodology for design and analysis of MHK technologies, including models for estimating their capital costs, operational costs, and levelized costs of energy. The point designs also served as open-source test articles for university researchers and commercial technology developers. The RMP project team, led by Sandia National Laboratories (SNL), included a partnership between DOE, three national laboratories, including the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), and Oak Ridge National Laboratory (ORNL), the Applied Research Laboratory of Penn State University, and Re Vision Consulting. Reference Model 3 (RM3) is a wave point absorber, also referred to as a wave power buoy, that was designed for a reference site located off the shore of Eureka in Humboldt County, California. The design of the device consists of a surface float that translates (oscillates) with wave motion relative to a vertical column spar buoy, which connects to a subsurface reaction plate. This two-body point absorber converts wave energy into electrical power predominately from the devices heave oscillation induced by incident waves; the float is designed to oscillate up and down the vertical shaft up to 4 m. The bottom of the reaction plate is about 35 m below the water surface. The device is targeted for deployment in water depths of 40 m to 100 m. The point absorber is also connected to a mooring system to keep the floating device in position.

16 TIDAL AND WAVE POWER↗

Nuclear Criticality Safety Assessment of Criticality Control Containers without Moderation Control at the Waste Isolation Pilot Plant

The Waste Isolation Pilot Plant (WIPP) provides for safe, permanent disposal of government-owned transuranic (TRU) and TRU mixed wastes. Receipt and disposal of waste at the WIPP site began in March 1999. The Sandia report, Consideration of Nuclear Criticality When Disposing of Transuranic Waste at the Waste Isolation Pilot Plant, addressed potential nuclear criticality safety issues based on the projected inventory characteristics known at the time [1]. As designs for inventory, waste forms, and disposal packages have changed, new analyses have been performed, and updates have been made to address any potential effects to the WIPP safety basis. New analyses performed include Saylor 2017 [2] and Brickner 2019 [3], which address certain waste containers with specified loadings under post-closure conditions. Both examined several hypothetical scenarios and included analyses to bound (from a criticality potential standpoint) credible configurations that could occur at WIPP during the repository regulatory post-closure disposal time period for feature, event, and process (FEP) considerations—10,000 years. During this post-closure period at WIPP, the screening of FEPs is governed by the risk-based standards and implementing regulations of the US Environmental Protection Agency (EPA) (i.e., 40 CFR 191 and 40 CFR 194, respectively) [4,5]. An FEP screening can be based on either a low-consequence or low-probability rationale. A low-probability rationale includes either (a) a qualitative rationale that the FEP is not credible or (b) a quantitative demonstration that the probability is less than 10-4 in 104 years. In this evaluation, a qualitative lowprobability rationale of not credible is used by demonstrating that bounding configurations of the waste are not critical. The demonstration of subcriticality is through quantitative calculations, but a probability of criticality is not evaluated. Rather, the rationale for this evaluation is that bounding configurations with an effective neutron multiplication factor (keff) well below the upper subcriticality limit (USL) make criticality incredible. Reference [2] documented a nuclear criticality assessment of the WIPP repository for disposal of dilute surplus plutonium materials using the Dilute and Dispose Approach and packaging in criticality control overpacks (CCOs). The CCO is the waste disposal container recently designed to allow for up to 380 fissile gram equivalent (FGE) 239 Pu per drum, which is a higher fissile loading than typical waste containers. The CCO consists of a criticality control container (CCC) positioned by upper and lower plywood spacers within a standard 55 gal drum. The CCC is used to establish a geometry control for fissile materials during transportation and WIPP emplacement operations. The current WIPP waste acceptance criteria for CCO payloads limit beryllium to less than or equal to 1% by weight of the waste contents and require the waste form to be non-machine compacted. Reference [2] considered two scenario progressions—room closure from salt creep, hereafter referred to as the reconfigured dry scenario, and flooding with brine, hereafter referred to as the reconfigured wet scenario. The subsequent drying out of the reconfigured wet scenarios was also considered. For all scenarios, subcriticality was maintained when 50 g of B 4 C (acting as a neutron absorber) per CCC was intermixed within the plutonium disposition waste form. The analysis used a waste form description that limits the amount of moderation that could be present within the waste form (i.e., it limits the amount of water and polyethylene that could be present based on planned processing conditions). This analysis to evaluate increased limits on the amount of moderation that could be present was performed as a companion to Reference [2] to address concerns associated with verifying moisture and/or plastic contents of waste materials following packaging of dilute surplus plutonium in the CCO. To that end, this analysis used the models and methods from Reference [2] to evaluate a more generic base waste form consisting of water and polyethylene that is more similar (and nearly identical) to the generic waste forms utilized in other models/analyses supporting the TRU Package Transporter Model II (TRUPACTII) safety analysis [6] (all are without moderation controls). The waste form in this analysis uses a base mixture of 75% water and 25% polyethylene, the total amount of which is varied to determine the optimum moderation to fissile material (H/Pu) ratio. The fissile loading is maintained at up to 380 FGE 239 Pu (modeled as PuO 2 ) per CCO with an additional 545 g of beryllium (to bound the 1% by weight contents restriction) and 50 g of B 4 C intermixed per CCO. The beryllium content (1% by weight) is based on the total allowed waste weight (this does not include packaging and container weights). Figures ES-1 and ES-2 display summary results, showing that with this model including 50 g of B 4 C per CCO, the system keff remains under 0.85 for all moderator amounts and provides a significant margin against post-closure criticality under postulated bounding conditions for compaction. Figure ES-1 compares an infinite model with a room model at the initial emplacement spacing and under full radial compaction. Full radial compaction places each CCC in direct contact and does not credit any anticipated spacing associated with current post-closure geomechanical modeling of the repository [7]. The effects of variations in the H/Pu ratio were evaluated by varying the amount of the water/polyethylene component of the waste model, with fissile loading maintained at 380 239 Pu FGE. Similarly, Figure ES-2 illustrates how various amounts of B 4 C per CCO influence k eff at different radial compactions, all at the H/Pu ratio of 200 (in the room array model). Therefore, while the results from Saylor 2017 [2] modeled more realistic process limits associated with packaging of dilute surplus plutonium, this analysis demonstrates that limits on moderation (plastic and water content) are not necessary to ensure subcriticality in the WIPP repository, provided the requisite B 4 C absorber is present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinetic modeling of [ 18 F]V AT , a novel radioligand for positron emission tomography imaging vesicular acetylcholine transporter in non‐human primate brain

Abstract Molecular imaging of vesicular acetylcholine transporter ( VACh T) in the brain provides an important cholinergic biomarker for the pathophysiology and treatment of dementias including Alzheimer's disease. In this study, kinetics modeling methods were applied and compared for quantifying regional brain uptake of the VACh T‐specific positron emission tomography radiotracer, ((−)‐(1‐(‐8‐(2‐fluoroethoxy)‐3‐hydroxy‐1,2,3,4‐tetrahydronaphthalen‐2‐yl)piperidin‐4‐yl)(4‐fluorophenyl)‐methanone) ([ 18 F]V AT ) in macaques. Total volume distribution ( V T ) estimates were compared for one‐tissue compartment model (1 TCM ), two‐tissue compartment model (2 TCM ), Logan graphic analysis (LoganA IF ) and multiple linear analysis (M A 1) with arterial blood input function using data from three macaques. Using the cerebellum‐hemispheres as the reference region with data from seven macaques, three additional models were compared: reference tissue model ( RTM ), simplified RTM ( SRTM ), and Logan graphic analysis (Logan REF ). Model selection criterion indicated that a) 2 TCM and SRTM were the most appropriate kinetics models for [ 18 F]V AT ; and b) S RTM was strongly correlated with 2 TCM (Pearson's coefficients r > 0.93, p < 0.05). Test–retest studies demonstrated that [ 18 F]V AT has good reproducibility and reliability ( TRV < 10%, ICC > 0.72). These studies demonstrate [ 18 F]V AT is a promising VACh T positron emission tomography tracer for quantitative assessment of VACh T levels in the brain of living subjects. image

Jin, Hongjun↗

System Response Testing of HEAF Kevex 130kV Microfocus Source and Thales Flashscan Panel I. Step-wedge Measurements

In the Small Sample DR Testing series, a few questions have arisen when comparing modeled results to experimental data. It is necessary to evaluate these questions in order to validate the modeling assumptions and to ensure the validity of the test procedure in the Small Sample DR Testing. Open Questions: (1) The decay time of the scintillator elements is unknown. (2) The thickness of the Beryllium window on the source is unknown. (3) The residual effects of beam angle and scattering within the detector assembly are unknown. (4) The spectral response of the scintillator and digitizing panel are not known. (5) The spectral content of the source is unknown. Item 1 will be addressed in separate tests by measuring the output of the panel at various intervals after the source has stopped illuminating the panel. Item 2 will be determined by finding the manufacturer specifications. Item 3 will be addressed in separate tests. We cannot easily address items 4 and 5 independently. Measuring the spectral responsivity of the detector directly would require the use of a calibrated reference source, which we lack. Similarly, measuring the spectral content of the source requires spectrally and spatially calibrated detectors, which we also lack. However, we can address the combination of items 1 and 2 to deduce the product of source intensity times detector response. By measuring the X-ray transmittance of samples of known thickness, material composition and density (step wedges), we can infer the desired product and so validate and improve computer models of our system.

47 OTHER INSTRUMENTATION↗

An Experimental Investigation of Fuel Staging In A Model Gas Turbine Combustor

Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged-stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τ Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a Modern gas turbine engines are typically operated in a lean-premixed configuration in order to meet emissions requirements. Lean operation makes gas turbines more susceptible to combustion instability, which can cause catastrophic hardware failure if left unchecked. The spatially uneven distribution of fuel in a gas turbine combustor, known as fuel staging, is an effective way of suppressing instabilities. This dissertation examines the effect of both steady-state and transient fuel-staging in a model gas turbine combustor. First, the steady-state effect of fuel staging on nominally unstable operating conditions is examined. At 200 degrees Celsius and a bulk flow velocity of 26 m/s, the combustor undergoes self-excited instabilities when the equivalence ratio is between φ = 0.70 and φ = 0.74 when all nozzles are fueled equally. These instabilities are suppressed when the center nozzle equivalence ratio is increased to φ Staging = 0.85 and the outer nozzle equivalence ratio maintained at φ = 0.70 or when the global equivalence ratio is maintained at φ = 0.70 by increasing the center nozzle equivalence ratio to φ Staging = 0.74 and decreasing the outer nozzle equivalence ratio to φ Staging = 0.69. The staged p' RMS amplitudes are found to decrease with increasing equivalence ratio and the damping rates found to increase with increasing equivalence ratio. Next, axisymmetric fuel staging transients are conducted valve opening/closing timescales of 1, 16, 58, 4,000, and 10,000 ms, and equivalence ratios of φ staging = 0.75, 0.80, 0.85. It should be noted that these valve opening/closing timescales, referred to as τ Transient , differ from the actual fuel convection timescale that are summarized in Table 5.2. It is found that the combustor pressure fluctuation at the end of the transient strongly depends on staging equivalence ratio but not on τ Transient . Increasing the staging equivalence ratio decreased the staged- stable combustor pressure amplitude, similarly to the steady-state results. The staged-stable damping rate trends are insensitive to to τT Transient and increased with increasing staging equivalence ratio. The timescale of the transition, τ, is found to be sensitive to both τ Transient and the staging equivalence ratio. For a given τ Transient , the decay timescale decreased with increasing staging equivalence ratio. For 1, 16, and 58 ms transients, τ does not depend on τ Transient , though it does strongly depend on direction, where instability onset cases have longer and more variable τ than instability decay cases. The same dependence of τ on direction is seen for the 4,000 and 10,000 ms transients. However, unlike the short duration transients, τ does depend on τ Transient as would be expected. Phase space reconstruction shows the instability is a harmonic limit cycle with a single frequency. The instantaneous phase images shows the center region of the combustor goes out-of-phase first followed by the rest of the combustor. Finally, asymmetric fuel staging tests are conducted. It is found that non-axisymmetric staging can be as effective as axisymmetric staging, although small hardware variations between nozzles can affect the the minimum staging equivalence ratio that consistently suppresses the instability. These changes in the bifurcation equivalence ratio can make staging configurations appear less effective; however, both axisymmetric and non-axisymmetric staging configurations exhibit similar staged-stable p' RMS , damping rates, and instability transition times for equivalence ratios greater than the bifurcation equivalence ratio. Instantaneous phase images show similar instantaneous phase relationship structures in the staged nozzle (center or outer), suggesting that the instability suppression mechanism is similar in each case. This result is surprising given that the time-averaged flame shapes are very different between axisymmetric and non-axisymmetric staging configurations. The similar effectiveness of axisymmetric and non-axisymmetric staging in this geometry is attributed to the fact that the instability mode is a nominally axisymmetric plane wave. It is hypothesized that non-axisymmetric staging configurations will likely be more effective than axisymmetric staging configurations when the instability mode shape is asymmetric (such as a circumferential wave).

Culler, Wyatt↗

CARS diagnostics of the burning of H{sub 2} - O{sub 2} and CH{sub 4} - O{sub 2} mixtures at high temperatures and pressures

Coherent anti-Stokes Raman scattering (CARS) spectroscopy is used to determine the parameters of gaseous combustion products of hydrogen and hydrocarbon fuels with oxygen at high temperatures and pressures. The methodical aspects of CARS thermometry, which are related to the optimal choice of molecules (diagnostic references) and specific features of their spectra, dependent on temperature and pressure, are analysed. Burning is modelled under the conditions similar to those of real spacecraft propulsion systems using a specially designed laboratory combustion chamber, operating in the pulse-periodic regime at high temperatures (to 3500 K) and pressures (to 20 MPa) of combustion products. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward fully self-consistent simulation of the interaction of E-Clouds and beams with WARP-POSINST

To predict the evolution of electron clouds and their effect on the beam, the high energy physics community has relied so far on the complementary use of 'buildup' and 'single/multi-bunch instability' reduced descriptions. The former describes the evolution of electron clouds at a given location in the ring, or 'station', under the influence of prescribed beams and external fields [1], while the latter (sometimes also referred as the 'quasi-static' approximation [2]) follows the interaction between the beams and the electron clouds around the accelerator with prescribed initial distributions of electrons, assumed to be concentrated at a number of discrete 'stations' around the ring. Examples of single bunch instability codes include HEADTAIL [3], QuickPIC [4, 5], and PEHTS [6]. By contrast, a fully self-consistent approach, in which both the electron cloud and beam distributions evolve simultaneously under their mutual influence without any restriction on their relative motion, is required for modeling the interaction of high-intensity beams with electron clouds for heavy-ion beam-driven fusion and warm-dense matter science. This community has relied on the use of Particle-In-Cell (PIC) methods through the development and use of the WARP-POSINST code suite [1, 7, 8]. The development of novel numerical techniques (including adaptive mesh refinement, and a new 'drift-Lorentz' particle mover for tracking charged particles in magnetic fields using large time steps) has enabled the first application of WARP-POSINST to the fully self-consistent modeling of beams and electron clouds in high energy accelerators [9], albeit for only a few betatron oscillations. It was recently observed [10] that there exists a preferred frame of reference which minimizes the number of computer operations needed to simulate the interaction of relativistic objects. This opens the possibility of reducing the cost of fully self-consistent simulations for the interaction of ultrarelativistic beams with electron cloud by orders of magnitude. The computational cost of the fully self-consistent mode is then predicted to be comparable to that of the quasi-static mode, assuming that several stations per betatron period are needed. During the workshop, there was some debate about the number of stations per betatron period that are needed when using the quasi-static mode. The argument was made that if there is less than one station per betatron period, then artificial resonances can be triggered and the resulting emittance growth provides an upper bound. The emittance growth thus obtained will fall either above or below the operational requirements of the machine. In the latter case, one can conclude that the electron effect that has been simulated is of no concern. However, if the emittance growth that was obtained is above the threshold, then the results become inconclusive, and simulations which resolve the betatron motion are then needed. In this case, according to [10], the fully self-consistent approach becomes an option. The aim of this paper is to investigate whether this option is indeed practical.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Communication: Orientational self-ordering of spin-labeled cholesterol analogs in lipid bilayers in diluted conditions

Lipid-cholesterol interactions are responsible for different properties of biological membranes including those determining formation in the membrane of spatial inhomogeneities (lipid rafts). To get new information on these interactions, electron spin echo (ESE) spectroscopy, which is a pulsed version of electron paramagnetic resonance (EPR), was applied to study 3β-doxyl-5α-cholestane (DCh), a spin-labeled analog of cholesterol, in phospholipid bilayer consisted of equimolecular mixture of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine. DCh concentration in the bilayer was between 0.1 mol.% and 4 mol.%. For comparison, a reference system containing a spin-labeled 5-doxyl-stearic acid (5-DSA) instead of DCh was studied as well. The effects of “instantaneous diffusion” in ESE decay and in echo-detected (ED) EPR spectra were explored for both systems. The reference system showed good agreement with the theoretical prediction for the model of spin labels of randomly distributed orientations, but the DCh system demonstrated remarkably smaller effects. The results were explained by assuming that neighboring DCh molecules are oriented in a correlative way. However, this correlation does not imply the formation of clusters of cholesterol molecules, because conventional continuous wave EPR spectra did not show the typical broadening due to aggregation of spin labels and the observed ESE decay was not faster than in the reference system. So the obtained data evidence that cholesterol molecules at low concentrations in biological membranes can interact via large distances of several nanometers which results in their orientational self-ordering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CFD-Informed Spacer Grid Models in CTF: Heat Transfer Enhancement and Form Pressure Losses

This report presents the current status of the pressure loss coefficient and heat transfer enhancement models derived for CTF from computational fluid dynamics (CFD) data. This is an effort to improve the modeling capabilities of CTF using results from a higher-fidelity code such as STAR-CCM+. The following four phenomena are the current scope of CFD-informed spacer grid models for CTF: (1) grid directed lateral cross-flow effects; (2) grid-induced turbulent-mixing effects; (3) grid-induced heat transfer enhancement downstream of the grid; and (4) the detailed pressure-loss effects caused by the spacer grid. This document covers phenomena (3) and (4) and how they are captured using CFD data. Please refer to CASL-U-2015-0020-000 for a discussion on phenomena (1) and (2).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗