Search NASA⌕ Search

SEARCH · Search NASA

Results for “Remediation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Single‐Step Recovery of Water from Stable Crude Oil‐Water Emulsion Using Surface Engineered Hybrid Inorganic‐Polymer Membranes

ABSTRACT Separating crude oil from water remains one of the most stubborn challenges in environmental remediation, especially for surfactant‐stabilized emulsions that resist conventional demulsification methods. Here, we report a scalable strategy for achieving near‐zero‐discharge separation of crude oil emulsions using a single superhydrophilic membrane. By applying low‐temperature atomic layer deposition (ALD) of various metal oxides onto activated polyvinylidene fluoride (PVDF) membranes, we create atomically precise surface‐engineered (SE) membranes that maintain an exceptionally strong hydration layer at the membrane‐feed interface, even at high oil loadings. Among the various metal oxides, TiO 2 ‐modified SE membranes exhibit superior interfacial water stability, enabling sustained dewatering of complex crude oil‐water emulsions with >98% separation efficiency and >97% water recovery, compared to only 24.6% water recovery for the pristine membrane. This separation performance surpasses conventional hydrophilic membranes and is comparable to complex Janus channel membrane systems, demonstrating near‐complete emulsion separation using a single membrane. This low‐temperature membrane surface engineering process with atomic‐level precision and potential for scalability via roll‐to‐roll fabrication is promising for industrial‐scale, energy‐efficient water treatment and oil spill remediation applications.

Sengupta, Bratin [Applied Materials Division Argon↗

Roles of surface Mn(III) and MgOH + /CaOH + complexation in photochemically assisted Mn 2+ oxidation and Todorokite formation

Todorokite, a Mn oxide phase commonly found in seafloor Mn nodules, is one of the most abundant Mn oxides in nature and has wide applications in environmental engineering, including heavy metal remediation, contaminant adsorption for water purification, and catalysis for organic pollutant degradation. However, traditional abiotic formation of todorokite reported to date typically requires high temperature, pressure, and pH outside circumneutral conditions, or involves several days of phase transformations from precursor phases. In this study, we demonstrate rapid todorokite formation within 6 h via photochemically assisted oxidation of Mn 2+ (aq) in the presence of Mg 2+ or Ca 2+ , notably at ambient temperature and pressure. The concentrations of aqueous MgOH + and CaOH + , as well as the pH (initial 9 or 6), had significant collective influences on the crystalline phases of the formed Mn oxide solids. The proportions of the Mn oxidation states (IV, III, and II) and the extent of Mn(III) surface complexation with MgOH + or CaOH + controlled the crystalline phases (todorokite, feitknechtite, and birnessite) and the extent of cation incorporation into the resulting Mn oxide solids. Specifically, the oxidation state of Mn influenced the crystallization of different Mn oxide phases, and the formed Mn(III) complexed with MgOH + or CaOH + facilitated the formation of todorokite, along with cation incorporation. X-ray pair distribution function analysis revealed that incorporated Mg species were located at the inside corner sites of the 5 × 3 MnO 6 octahedral tunnel structure of todorokite, suggesting complexation between MgOH + and Mn(III) at the corners of the tunnel. Furthermore, this study provides novel insights into the elusive formation of todorokite and its potential for applications in advanced water treatment and environmental remediation.

Abiotic Mn2+ oxidation↗

Interactions between phosphate and arsenic in iron/biochar-treated groundwater: Corrosion control insights from column experiments

An increasing number of studies have reported the coexistence of arsenic (As) and phosphorus at high concentrations in groundwater, which threatens human health and increases the complexity of groundwater remediation. However, limited work has been done regarding As interception in the presence of phosphate in flowing systems. In this study, a series of experiments were conducted to evaluate the interactions between phosphate and As during As removal by iron (Fe)-based biochar (FeBC). The addition of phosphate promoted As removal by FeBC in the batch and column experiments. X-ray absorption near edge structure (XANES) analysis provided evidence of simultaneous oxidation and reduction of trivalent arsenic in the FeBC column experiment, accompanied by corrosive Fe oxidation. However, the addition of phosphate enhanced As stabilization, attributed to the As-incorporated Fe-Ca-phosphates precipitates. The involvement of phosphate decelerated the Fe corrosion and the formation of secondary minerals in the column, mediating the risk of passivation and clogging. The As retained by Fe-Ca-phosphate precipitates was more readily oxidized, resulting in higher proportions of pentavalent arsenic. In conclusion, the results of this work identify the corrosion control and sustained-release roles of phosphate in FeBC application, informing the perspective of FeBC in As-contaminated groundwater remediation and providing new insights into the interactions between phosphate and As.

54 ENVIRONMENTAL SCIENCES↗

Interactions between Per- and Polyfluoroalkyl Substances (PFAS) at the Water–Air Interface

Per- and polyfluoroalkyl substances (PFAS)--so-called “forever chemicals”--contaminate the drinking water of about 100 million people in the U.S. alone and are inefficiently removed by standard treatment techniques. A key property of these compounds that underlies their fate and transport and the efficacy of several promising remediation approaches is that they accumulate at the water−air interface. This phenomenon remains incompletely understood, particularly under conditions relevant to natural and treatment systems where water−air interfaces often carry significant loads of other organic contaminants or natural organic matter. To understand the impact of organic loading on PFAS adsorption, we carried out molecular dynamics simulations of PFAS at varying interfacial densities. We find that adsorbed PFAS form strong mutual interactions (attraction between perfluoroalkyl chains and electrostatic interactions among charged head groups) that give rise to ordered interfacial coatings. Furthermore, these interactions often involve near-cancellation of hydrophobic attraction and Coulomb repulsion. Our findings explain an apparent paradox whereby PFAS adsorption isotherms often suggest minimal mutual interactions while simultaneously displaying a high sensitivity to the composition and density of interfacial coatings. Consideration of the compounds present with PFAS at the interface has the potential to allow for more accurate predictions of fate and transport and the design of more efficient remediation approaches.

54 ENVIRONMENTAL SCIENCES↗

A multifunctional technology platform for sorbent construction using polyacrylonitrile scaffolds

Polyacrylonitrile (PAN) is a synthetic polymer that shows high potential for use in a wide range of environmental remediation applications. PAN can be implemented in various ways within a batch or continuous process stream for use as a passive scaffold holding active gettering materials in place or where the PAN scaffold (e.g., beads, fiber mats, membranes) is functionalized with active chelating groups (e.g., amine, hydrazide, amidoximes, carboxyl). Application spaces covered in this review include remediation of heavy metals (e.g., Ag, As, Cd, Cr6+, Cu, Pb, Sb, and Se), high-dose fission products (e.g., 90Sr, 137Cs), radioiodine (i.e., 129I), noble gases (i.e., Xe, 85Kr), rare earths (e.g., Ce, Y), and actinides (e.g., Am, Pu, U). Methods for producing PAN composite sorbents are discussed. Options are also discussed for removing the PAN matrix following chemisorption of an active contaminant to minimize waste volumes requiring disposal.

polyacrylonitrile, composite sorbents, sulfides, a↗

Alizarin Multilayers Adsorbed onto Glassy Carbon Electrodes for Electrochemical Sequestration of Manganese, Sodium, and Lithium Cations

The development of efficient methods for metal ion recovery and water remediation is critical for addressing the nation’s urgent need for secure domestic supply chains, overcoming critical materials challenges, and ensuring resilient manufacturing. Here, we present a novel approach for synthesizing stable Alizarin (Alz, 1,2-dihydroxy anthraquinone) multilayers on glassy carbon electrodes (GCEs) for electrochemical sequestration of manganese, sodium, and lithium cations. Alz-GCEs exhibit negatively shifted reduction potentials, indicating strong interactions between Alz and metal cations through metal-coupled electron transfer (MCET) mechanisms. The cation binding interactions and redox behavior of these electrodes were investigated using cyclic voltammetry (CV) and density functional theory (DFT) calculations. Our results demonstrate that Alz forms multilayer structures on GCEs with redox properties that are modulated by the presence of metal cations in the electrolyte. DFT calculations provide insights into the electrochemical mechanism, indicating both stepwise and concerted pathways for metal binding. The findings highlight the potential of Alz-GCEs for efficient and selective metal ion capture, which could be useful for developing sustainable materials for critical metal recovery and water remediation. This work suggests that redox-mediated organic adlayers are promising candidates for advancing electrochemical separation technologies of metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rheinheimera sp . T2C2 Bacterial Biofilm for Bioremediation of Cobalt(II)

Toxic metals, including cobalt, are often the cause of the contamination of rivers and lakes in mining regions. Heavy metal water pollution has been linked to numerous human health problems, prompting the need for environmental remediation. Existing techniques for removing heavy metals from water, such as chemical precipitation and filtration, produce toxic waste, are costly, or require high power consumption for pumping. Biosorption is a potential alternative strategy that is cost-effective and uses readily available and naturally produced biomass and living material to absorb pollutants. Engineering living materials, such as biofilms, which consist of living cells and a secreted polymer matrix, offer the potential to integrate toxin sensing, sequestration, and metabolism capabilities of cells to improve pollution remediation strategies. Alternative biofilm producing candidates need to be explored to implement these material capabilities. Previous biosorption studies have primarily used bacterial biofilms from known pathogens and/or generated toxic waste in the form of the absorbent material combined with the heavy metal. Here, we describe a recently isolated bacterium called Rheinheimera sp. T2C2 that forms biofilms with promising biosorption characteristics. T2C2 is an aquatic bacterium with low nutrient requirements and high biofilm production that is not known to be pathogenic. We demonstrate (1) the efficacy of Rheinheimera sp. T2C2 as a biosorbent for cobalt bioremediation; (2) how biosorption is altered by water conditions to establish the efficacy of this strategy in different environments; and (3) how the metal can be released from the biofilm for metal recycling. Our findings will provide a living materials strategy that overcomes the existing barriers for bioremediation and improves the health of ecosystems and humans through heavy metal removal and recycling.

Rheinheimera↗

Interfacial dynamics mediate surface binding events on supramolecular nanostructures

The dynamic behavior of biological materials is central to their functionality, suggesting that interfacial dynamics could also mediate the activity of chemical events at the surfaces of synthetic materials. Here, we investigate the influence of surface flexibility and hydration on heavy metal remediation by nanostructures self-assembled from small molecules that are decorated with surface-bound chelators in water. We find that incorporating short oligo(ethylene glycol) spacers between the surface and interior domain of self-assembled nanostructures can drastically increase the conformational mobility of surface-bound lead-chelating moieties and promote interaction with surrounding water. In turn, we find the binding affinities of chelators tethered to the most flexible surfaces are more than ten times greater than the least flexible surfaces. Accordingly, nanostructures composed of amphiphiles that give rise to the most dynamic surfaces are capable of remediating thousands of liters of 50 ppb Pb 2+ -contaminated water with single grams of material. These findings establish interfacial dynamics as a critical design parameter for functional self-assembled nanostructures.

42 ENGINEERING↗

Electrodialysis and nitrate reduction (EDNR) to enable distributed ammonia manufacturing from wastewaters

Underutilized wastewaters containing dilute levels of reactive nitrogen (Nr) can help rebalance the nitrogen cycle. This study describes electrodialysis and nitrate reduction (EDNR), a reactive electrochemical separation architecture that combines catalysis and separations to remediate nitrate and ammonium-polluted wastewaters while recovering ammonia. By engineering operating parameters (e.g., background electrolyte, applied potential, electrolyte flow rate), we achieved high recovery and conversion of Nr in both simulated and real wastewaters. The EDNR process demonstrated long-term robustness and up-concentration that recovered >100 mM ammonium fertilizer solution from agricultural runoff that contained 8.2 mM Nr. EDNR is the first reported process to our knowledge that remediates dilute real wastewater and recovers ammonia from multiple Nr pollutants, with an energy consumption (245 MJ per kg NH 3 –N in simulated wastewater, 920 MJ per kg NH 3 –N in agricultural runoff) on par with the state-of-the-art. Demonstrated first at proof-of-concept and engineered to technology readiness level (TRL) 4–5, EDNR shows great promise for distributed wastewater treatment and sustainable ammonia manufacturing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Whole metagenome sequencing and 16S rRNA gene amplicon analyses reveal the complex microbiome responsible for the success of enhanced in-situ reductive dechlorination (ERD) of a tetrachloroethene-contaminated Superfund site

The North Railroad Avenue Plume (NRAP) Superfund site in New Mexico, USA exemplifies successful chlorinated solvent bioremediation. NRAP was the result of leakage from a dry-cleaning that operated for 37 years. The presence of tetrachloroethene biodegradation byproducts, organohalide respiring genera (OHRG), and reductive dehalogenase (rdh) genes detected in groundwater samples indicated that enhanced reductive dechlorination (ERD) was the remedy of choice. This was achieved through biostimulation by mixing emulsified vegetable oil into the contaminated aquifer. This report combines metagenomic techniques with site monitoring metadata to reveal new details of ERD. DNA extracts from groundwater samples collected prior to and at four, 23 and 39 months after remedy implementation were subjected to whole metagenome sequencing (WMS) and 16S rRNA gene amplicon (16S) analyses. The response of the indigenous NRAP microbiome to ERD protocols is consistent with results obtained from microcosms, dechlorinating consortia, and observations at other contaminated sites. WMS detects three times as many phyla and six times as many genera as 16S. Both techniques reveal abundance changes in Dehalococcoides and Dehalobacter that reflect organohalide form and availability. Methane was not detected before biostimulation but appeared afterwards, corresponding to an increase in methanogenic Archaea. Assembly of WMS reads produced scaffolds containing rdh genes from Dehalococcoides, Dehalobacter, Dehalogenimonas, Desulfocarbo, and Desulfobacula. Anaerobic and aerobic cometabolic organohalide degrading microbes that increase in abundance include methanogenic Archaea, methanotrophs, Dechloromonas, and Xanthobacter, some of which contain hydrolytic dehalogenase genes. Aerobic cometabolism may be supported by oxygen gradients existing in aquifer microenvironments or by microbes that produce O 2 via microbial dismutation. The NRAP model for successful ERD is consistent with the established pathway and identifies new taxa and processes that support this syntrophic process. This project explores the potential of metagenomic tools (MGT) as the next advancement in bioremediation.

59 BASIC BIOLOGICAL SCIENCES↗

Is Clean Hydrogen Production a Good Fit for Questa? (Final Economic Impact Results) [Slides]

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

Is Clean Hydrogen Production a Good Fit for Questa? Final Economic Impact Results

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

2024 Geothermal Rising Conference Poster

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC, an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration with increased time on bottom for each bit. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate bit technologies. The first demonstration well has been completed, with a total of 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three hole sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges.

15 GEOTHERMAL ENERGY↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydraulic Performance of Funnel & Gate and Base Injection at the F-Area Seepage Basins

The SGW-Support Group Environmental Compliance and Area Completion Projects (EC&ACP) of Savannah River Nuclear Solutions (SRNS) operates a funnel and gate (F&G) passive groundwater remediation system in conjunction with base injection to restore the quality of groundwater migrating from the F-Area seepage basins to Fourmile Branch. Groundwater levels were monitored biweekly and continuously over a 15-month period to study the aerial and temporal effect of operating the F&G and base injection remediation systems.

42 ENGINEERING↗

Vertical Characterization of Flow and Contaminant Concentration in New Hanford Extraction Wells

Effective groundwater remediation should focus on high-concentration, low-permeability zones within the aquifer, as these areas often present significant challenges to contaminant removal. Characterizing the vertical distribution of contamination in an aquifer is therefore critical for optimizing and monitoring pump-and-treat (P&T) systems to meet target cleanup timelines. Flow patterns driven by hydraulic gradients and variations in permeability are described to provide insight into contaminant mass removal from long-screened wells. The objective of this multi-phase work is to provide actionable recommendations for improving remedy performance monitoring and P&T operations, which ongoing evaluations will address. This report summarizes the preliminary results of vertical flow and contaminant distribution monitoring in new extraction wells at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Assessment and Simulation of Particulate Transport for Delivery of Solid Amendments into the Subsurface: FY25 Status Report

For particulate-based amendments to be viable for field-scale remediation at the Hanford Site (e.g., the 200 DV-1 Operable Unit), amendment particles need to be delivered a reasonable distance away from an injection well to provide cost effective in situ treatment. Field-scale particle transport models can estimate spatial deposition of amendment particles in the subsurface, which is critical for developing an overall remediation strategy. However, field-scale particle simulations are currently limited due to insufficient simulation capability and a lack of experimental data to validate and parameterize particle transport models. During this fiscal year, the following progress has been made toward a field-scale particle transport modeling evaluation: (1) in addition to the two particle transport models implemented last FY, four additional particle transport models have been implemented within PFLOTRAN; (2) a Python-based pre-screening tool was finalized, enabling users to quickly estimate the particle radius of influence (ROI) for any given particle-amendment system; and (3) an initial compatibility assessment was completed using both particle transport simulations deployed through the pre-screening tool, in conjunction with general guidelines to (a) identify the most suitable amendment particle sizes for various Hanford sediments and (b) evaluate amendment-delivery fluid compatibility. The preliminary compatibility assessment revealed that for amendment delivery success to the various Hanford target formations, amendment particle sizes will likely need to be smaller than the amendment sizes tested in the DV-1 treatability study. It is recommended that amendment particles be decreased in size, or alternative smaller size amendments be obtained from the manufacture, prior to any further experimental testing. Also, preliminary testing suggests that xanthan gum may be the most broadly compatible delivery fluid. Planned laboratory experiments will be instrumental in validating and refining the PFLOTRAN particulate transport model formulations, ultimately enabling predictive capabilities to facilitate the design of field-scale amendment delivery systems. This work consists of acquiring new theoretical or experimental knowledge. The information associated with this report should not be used as design input or operating parameters without additional qualification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗