Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reproducibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Advantages of a variable‐resolution global climate model in reproducing the seasonal evolution of East Asian summer monsoon

Abstract The East Asian summer monsoon (EASM) is unique among monsoon systems that it features meridional evolution of the summer monsoon. In this study, we evaluate the performances of a Variable‐Resolution Community Earth System Model (VR‐CESM) regionally refined over eastern China (14 km) in reproducing the seasonal evolution of EASM precipitation over China. Compared with reference datasets, VR‐CESM shows better performance than the corresponding globally uniform coarse‐resolution model CESM (quasi‐uniform 1°), especially over western China where complex local topography exists. The northward monsoon migration is closely related to low‐level southerly flows and vertical moisture advection, which are more reasonably simulated in VR‐CESM. The four critical timings of the EASM (monsoon onset, withdrawal, peak, and duration) are also better captured in VR‐CESM than in CESM. The corresponding spatial Pearson correlation coefficients of the four critical timings with respect to reference datasets are about 0.1 higher in VR‐CESM than those in CESM. Both models are most accurate in simulating monsoon onset and least accurate at simulating the monsoon peak. The overestimated zonal thermal contrast in CESM is responsible for the earlier monsoon onset and excessive precipitation in September over the Yangtze River valley. Finer resolution in VR‐CESM, especially over the Tibetan Plateau (TP), appears to be a main factor in simulating better zonal thermal contrast and seasonal evolution of the EASM.

54 ENVIRONMENTAL SCIENCES↗

Kernel Manifolds: Nonlinear‐Augmentation Dimensionality Reduction Using Reproducing Kernel Hilbert Spaces

This paper generalizes recent advances on quadratic manifold (QM) dimensionality reduction by developing kernel methods-based nonlinear-augmentation dimensionality reduction. QMs, and more generally feature map-based nonlinear corrections, augment linear dimensionality reduction with a nonlinear correction term in the reconstruction map to overcome approximation accuracy limitations of purely linear approaches. While feature map-based approaches typically learn a least squares optimal polynomial correction term, we generalize this approach by learning an optimal nonlinear correction from a user-defined reproducing kernel Hilbert space. Our approach allows one to impose arbitrary nonlinear structure on the correction term, including polynomial structure, and includes feature map and radial basis function-based corrections as special cases. Furthermore, our method has relatively low training cost and has monotonically decreasing error as the latent space dimension increases. In conclusion, we compare our approach to proper orthogonal decomposition and several recent QM approaches on data from several example problems.

kernel methods↗

A neural network‐enhanced reproducing kernel particle method for modeling strain localization

Abstract Modeling the localized intensive deformation in a damaged solid requires highly refined discretization for accurate prediction, which significantly increases the computational cost. Although adaptive model refinement can be employed for enhanced effectiveness, it is cumbersome for the traditional mesh‐based methods to perform while modeling the evolving localizations. In this work, neural network‐enhanced reproducing kernel particle method (NN‐RKPM) is proposed, where the location, orientation, and shape of the solution transition near a localization is automatically captured by the NN approximation via a block‐level neural network (NN) optimization. The weights and biases in the blocked parameterization network control the location and orientation of the localization. The designed basic four‐kernel NN block is capable of capturing a triple junction or a quadruple junction topological pattern, while more complicated localization topological patters are captured by the superposition of multiple four‐kernel NN blocks. The standard RK approximation is then utilized to approximate the smooth part of the solution, which permits a much coarser discretization than the high‐resolution discretization needed to capture sharp solution transitions with the conventional methods. A regularization of the NN approximation is additionally introduced for discretization‐independent material responses. The effectiveness of the proposed NN‐RKPM is verified by a series of numerical verifications.

Baek, Jonghyuk↗

Understanding Reproducibility of Sputter‐Deposited Metastable Ferroelectric Wurtzite Al 0.6 Sc 0.4 N Films Using In Situ Optical Emission Spectrometry

High‐Sc Al 1– x Sc x N thin films are of tremendous interest because of their attractive piezoelectric and ferroelectric properties, but overall film quality and reproducibility are widely reported to suffer as x increases. In this study, structural and electrical properties of metastable Al 0.6 Sc 0.4 N films are connected with plasma changes during film growth, identified via glow discharge optical emission spectroscopy (GD‐OES), and linked to the target mode changes. This in situ GD‐OES technique uses changes in the N 2 (I) intensity, correlated with DC bias hysteresis behavior of a Al 0.6 Sc 0.4 target in metallic and poisoned modes, to identify films that subsequently exhibit unacceptable structural and electrical performance. Two representative samples deposited under identical conditions but possessing distinct properties related to phases present in the films are focused on. Films sputtered under a poisoned target mode produce pure wurtzite ferroelectric Al 0.6 Sc 0.4 N with a reversible 80 μC cm −1 polarization and 3.1 MV cm −1 coercive field. When identical chamber settings are used but the process starts in metallic mode, a mixed wurtzite/rocksalt film is deposited which exhibits nanometer‐scale changes to the film microstructure and a nonferroelectric response. These results illustrate the utility of optical emission spectroscopy for tracking target mode fluctuations when fabricating metastable materials such as high‐Sc Al 1– x Sc x N films.

36 MATERIALS SCIENCE↗

Sensitivity Gains, Linearity, and Spectral Reproducibility in Nonuniformly Sampled Multidimensional MAS NMR Spectra of High Dynamic Range.

Recently, we have demonstrated that considerable inherent sensitivity gains are attained in MAS NMR spectra acquired by nonuniform sampling (NUS) and introduced maximum entropy interpolation (MINT) processing that assures the linearity of transformation between the time and frequency domains. In this report, we examine the utility of the NUS/MINT approach in multidimensional datasets possessing high dynamic range, such as homonuclear 13C–13C correlation spectra. We demonstrate on model compounds and on 1–73-(U-13C,15N)/74–108-(U-15N) E. coli thioredoxin reassembly, that with appropriately constructed 50 % NUS schedules inherent sensitivity gains of 1.7–2.1-fold are readily reached in such datasets. We show that both linearity and line width are retained under these experimental conditions throughout the entire dynamic range of the signals. Furthermore, we demonstrate that the reproducibility of the peak intensities is excellent in the NUS/MINT approach when experiments are repeated multiple times and identical experimental and processing conditions are employed. Finally, we discuss the principles for design and implementation of random exponentially biased NUS sampling schedules for homonuclear 13C–13C MAS correlation experiments that yield high quality artifact-free datasets.

Environmental Molecular Sciences Laboratory↗

Easy, Fast, and Reproducible Quantification of Cholesterol and Other Lipids in Human Plasma by Combined High Resolution MSX and FTMS Analysis

Reliable, cost-effective, and gold-standard absolute quantification of non-esterified cholesterol in human plasma is of paramount importance in clinical lipidomics and for the monitoring of metabolic health. Here, we compared the performance of three mass spectrometric approaches available for direct detection and quantification of cholesterol in extracts of human plasma. These approaches are high resolution full scan Fourier transform mass spectrometry (FTMS) analysis, parallel reaction monitoring (PRM), and novel multiplexed MS/MS (MSX) technology, where fragments from selected precursor ions are detected simultaneously. Evaluating the performance of these approaches in terms of dynamic quantification range, linearity, and analytical precision showed that the MSX-based approach is superior to that of the FTMS and PRM-based approaches. To further show the efficacy of this approach, we devised a simple routine for extensive plasma lipidome characterization using only 8 μL of plasma, using a new commercially available ready-to-spike-in mixture with 14 synthetic lipid standards, and executing a single 6 min sample injection with combined MSX analysis for cholesterol quantification and FTMS analysis for quantification of sterol esters, glycerolipids, glycerophospholipids, and sphingolipids. Using this simple routine afforded reproducible and absolute quantification of 200 lipid species encompassing 13 lipid classes in human plasma samples. Notably, the analysis time of this procedure can be shortened for high throughput-oriented clinical lipidomics studies or extended with more advanced MS{sup ALL} technology (Almeida R. et al., J. Am. Soc. Mass Spectrom. 26, 133–148 [1]) to support in-depth structural elucidation of lipid molecules. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantizations from reproducing kernel spaces

The purpose of this work is to explore the existence and properties of reproducing kernel Hilbert subspaces of L{sup 2}(C,d{sup 2}z/π) based on subsets of complex Hermite polynomials. The resulting coherent states (CS) form a family depending on a nonnegative parameter s. We examine some interesting issues, mainly related to CS quantization, like the existence of the usual harmonic oscillator spectrum despite the absence of canonical commutation rules. The question of mathematical and physical equivalences between the s-dependent quantizations is also considered. -- Highlights: ► We discuss in detail an interesting decomposition of L{sup 2}, in terms of ladder operators. ► We consider coherent states on this structure and we use them for quantization. ► We show how this structure is related with non hermitian quantum mechanics. ► We consider the relation between different schemes of quantizations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spontaneously supersaturated nucleation strategy for high reproducible and efficient perovskite solar cells

High-quality perovskite films are predominantly prepared by anti-solvent assisted spin-coating method. How- ever, small device size and narrow operation window limit their applications in practical and scalable production. Here, a spontaneously supersaturated nucleation strategy is developed to fabricate high-quality perovskite films without any antisolvents. The rapid precipitation behavior of the precursor solutions could be triggered by the volatilization of methylamine ethanol at the initial film formation stage, forming uniform and compact intermediate phase films. Mirror-like large area (10 cm × 10 cm) methylammonium lead triiodide (MAPbI 3 ) perovskite films with micrometer-sized grains can be achieved by phase transition via annealing. The average power conversion efficiency (PCE) of 19.4% is achieved for 0.1 cm 2 perovskite solar cells (PSCs). The 1 cm 2 device shows a PCE of 17.57% and retains 96.8% after aging for 39 days in the air with a relative humidity of 5–30%. The perovskite module based on the perovskite films prepared by our strategy exhibits a PCE of 13.13%. Here, the perovskite film fabrication method developed in this work shows high reproducibility of the fabrication process due to the spontaneous nucleation process. Meanwhile, it also exhibits significant potential in the application of scalable solution processing deposition techniques toward the commercialization of PSCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpretable and flexible non-intrusive reduced-order models using reproducing kernel Hilbert spaces

This paper develops an interpretable, non-intrusive reduced-order modeling technique using regularized kernel interpolation. Existing non-intrusive approaches approximate the dynamics of a reduced-order model (ROM) by solving a data-driven least-squares regression problem for low-dimensional matrix operators. Our approach instead leverages regularized kernel interpolation, which yields an optimal approximation of the ROM dynamics from a user-defined reproducing kernel Hilbert space. We show that our kernel-based approach can produce interpretable ROMs whose structure mirrors full-order model structure by embedding judiciously chosen feature maps into the kernel. The approach is flexible and allows a combination of informed structure through feature maps and closure terms via more general nonlinear terms in the kernel. We also derive a computable a posteriori error bound that combines standard error estimates for intrusive projection-based ROMs and kernel interpolants. In conclusion, the approach is demonstrated in several numerical experiments that include comparisons to operator inference using both proper orthogonal decomposition and quadratic manifold dimension reduction.

Data-driven model reduction↗

Interlaboratory Study: Testing Reproducibility of Solid Biofuels Component Identification Using Reflected Light Microscopy

Considering global market trends and concerns about climate change and sustainability, increased biomass use for energy is expected to continue. As more diverse materials are being utilized to manufacture solid biomass fuels, it is critical to implement quality assessment methods to analyze these fuels thoroughly. One such method is reflected light microscopy (RLM), which has the potential to complement and enhance current standard testing, leading to improving fuel quality assessment and, ultimately, preventing avoidable air pollution. An interlaboratory study (ILS) was conducted to test the reproducibility of biomass fuels component identification using a reflected light microscopy technique. The exercise was conducted on thirty photomicrographs showing biomass and various undesired components (like plastics or mineral matter), which were purposely added (by the ILS organizers) to contaminate wood pellets and charcoal-based grilling fuels. Forty-six participants had various levels of difficulty identifying the marked components, and as a result, the percentage of correct answers ranged from 52.2 to 94.4%. Among the most difficult components to distinguish were petroleum products and inorganic matter. Various reasons led to the misidentification, including insufficient morphological descriptions of the components provided to participants, ambiguities of the nomenclature, limitations of the analytical and exercise method, and insufficient experience of the participants. Overall, the results indicate that RLM has the potential to enhance the quality assessment of biomass fuels. However, they also demonstrate that the petrographic classification used in this exercise requires further refinement before it can be standardized. While a new simplified classification of solid biomass fuels components was created as an outcome of this study, future research is necessary to refine the nomenclature, develop a microscopic morphological description of the components, and verify the accuracy of component identification with a follow-up ILS.

biomass↗

Reproducibility of calculations on Li species with correlation-consistent basis sets

Here we have found that two different basis set series, both labeled cc-pVxZ, are widely available and widely used for calculation on Li compounds such that calculations that should be the same are different, causing a reproducibility problem. Here we study the magnitude of the disagreement of these nominally-the-same basis sets for wave function and density functional calculations of Li clusters. We find deviations among the basis sets of as large as 22 millihartrees. In most cases one obtains lower energies with the noncanonical choices. Therefore, it is important to specify which version of the basis set is used for calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Positional Reproducibility of Pancreatic Tumors Under End-Exhalation Breath-Hold Conditions Using a Visual Feedback Technique

Purpose: To assess positional reproducibility of pancreatic tumors under end-exhalation (EE) breath-hold (BH) conditions with a visual feedback technique based on computed tomography (CT) images. Methods and Materials: Ten patients with pancreatic cancer were enrolled in an institutional review board-approved trial. All patients were placed in a supine position on an individualized vacuum pillow with both arms raised. At the time of CT scan, they held their breath at EE with the aid of video goggles displaying their abdominal displacement. Each three-consecutive helical CT data set was acquired four times (sessions 1-4; session 1 corresponded to the time of CT simulation). The point of interest within or in proximity to a gross tumor volume was defined based on certain structural features. The positional variations in point of interest and margin size required to cover positional variations were assessed. Results: The means {+-} standard deviations (SDs) of intrafraction positional variations were 0.0 {+-} 1.1, 0.1 {+-} 1.2, and 0.1 {+-} 1.0 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively (p = 0.726). The means {+-} SDs of interfraction positional variations were 0.3 {+-} 2.0, 0.8 {+-} 1.8, and 0.3 {+-} 1.8 mm in the LR, AP, and SI directions, respectively (p = 0.533). Population-based margin sizes required to cover 95th percentiles of the overall positional variations were 4.7, 5.3, and 4.9 mm in the LR, AP, and SI directions, respectively. Conclusions: A margin size of 5 mm was needed to cover the 95th percentiles of the overall positional variations under EE-BH conditions, using this noninvasive approach to motion management for pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Reproducibility in Pancreatic Position Based on Four-Dimensional Computed Tomography

Purpose: To assess the interfractional positional variation of the pancreas using four-dimensional computed tomography (4D-CT) and to determine the suitable phase of respiration for dose delivery methods to account for pancreatic tumor motion. Methods and Materials: Fifteen patients with pancreatic cancer were enrolled in this study. For each patient, 4D-CT scans were performed at CT simulation and three times during the course of treatment. Regions of interest were set to the intrapancreatic bile ducts as a surrogate for pancreatic position. The centroids of the regions of interest were calculated at end-inhalation and end-exhalation of the respiration phase. The ranges of respiratory motion and interfractional positional variation were evaluated in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions. Results: The medians of respiratory motion were 1.1 mm (range, 0.0-9.8 mm), 1.5 mm (range, 0.0-7.0 mm), and 5.0 mm (range, 0.0-12.5 mm) in the LR, AP, and SI directions, respectively. The means {+-} SDs of the interfractional positional variation at end-inhalation were 0.9 {+-} 5.1 mm (range, -9.2 to 15.6 mm), -1.9 {+-} 3.9 mm (range, -12.8 to 6.4 mm), and -1.3 {+-} 6.9 mm (range, -15.0 to 13.7 mm) and those at end-exhalation were 0.0 {+-} 3.1 mm (range, -7.0 to 5.3 mm), -1.2 {+-} 3.9 mm (range, -11.2 to 6.7 mm), and 0.1 {+-} 3.2 mm (range, -9.9 to 5.1 mm) in the LR, AP, and SI directions, respectively. The SDs of the interfractional positional variation in the LR and SI directions were significantly larger at end-inhalation than at end-exhalation (LR, p < 0.001; SI, p < 0.001). Conclusions: The ranges of respiratory motion during the course of treatment and the interfractional positional variation were not negligible. The interfractional positional reproducibility was higher at end-exhalation than at end-inhalation under free breathing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Image-Guided Study of Setup Reproducibility of Postmastectomy Breast Cancer Patients Treated With Inverse-Planned Intensity Modulated Radiation Therapy

Purpose: To calculate planning target volume (PTV) margins for chest wall and regional nodal targets using daily orthogonal kilovolt (kV) imaging and to study residual setup error after kV alignment using volumetric cone-beam computed tomography (CBCT). Methods and Materials: Twenty-one postmastectomy patients were treated with intensity modulated radiation therapy with 7-mm PTV margins. Population-based PTV margins were calculated from translational shifts after daily kV positioning and/or weekly CBCT data for each of 8 patients, whose surgical clips were used as surrogates for target volumes. Errors from kV and CBCT data were mathematically combined to generate PTV margins for 3 simulated alignment workflows: (1) skin marks alone; (2) weekly kV imaging; and (3) daily kV imaging. Results: The kV data from 613 treatment fractions indicated that a 7-mm uniform margin would account for 95% of daily shifts if patients were positioned using only skin marks. Total setup errors incorporating both kV and CBCT data were larger than those from kV alone, yielding PTV expansions of 7 mm anterior–posterior, 9 mm left–right, and 9 mm superior–inferior. Required PTV margins after weekly kV imaging were similar in magnitude as alignment to skin marks, but rotational adjustments of patients were required in 32% ± 17% of treatments. These rotations would have remained uncorrected without the use of daily kV imaging. Despite the use of daily kV imaging, CBCT data taken at the treatment position indicate that an anisotropic PTV margin of 6 mm anterior–posterior, 4 mm left–right, and 8 mm superior–inferior must be retained to account for residual errors. Conclusions: Cone-beam CT provides additional information on 3-dimensional reproducibility of treatment setup for chest wall targets. Three-dimensional data indicate that a uniform 7-mm PTV margin is insufficient in the absence of daily IGRT. Interfraction movement is greater than suggested by 2-dimensional imaging, thus a margin of at least 4 to 8 mm must be retained despite the use of daily IGRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Important Is a Reproducible Breath Hold for Deep Inspiration Breath Hold Breast Radiation Therapy?

Purpose: Deep inspiration breath hold (DIBH) for left-sided breast cancer has been shown to reduce heart dose. Surface imaging helps to ensure accurate breast positioning, but it does not guarantee a reproducible breath hold (BH) at DIBH treatments. We examine the effects of variable BH positions for DIBH treatments. Methods and Materials: Twenty-five patients who underwent free breathing (FB) and DIBH scans were reviewed. Four plans were created for each patient: FB, DIBH, FB-DIBH (the DIBH plans were copied to the FB images and recalculated, and image registration was based on breast tissue), and P-DIBH (a partial BH with the heart shifted midway between the FB and DIBH positions). The FB-DIBH plans give a “worst-case” scenario for surface imaging DIBH, where the breast is aligned by surface imaging but the patient is not holding their breath. Kolmogorov-Smirnov tests were used to compare the dose metrics. Results: The DIBH plans gave lower heart dose and comparable breast coverage versus FB in all cases. The FB-DIBH plans showed no significant difference versus FB plans for breast coverage, mean heart dose, or maximum heart dose (P≥.10). The mean heart dose differed between FB-DIBH and FB by <2 Gy for all cases, and the maximum heart dose differed by <2 Gy for 21 cases. The P-DIBH plans showed significantly lower mean heart dose than FB (P<.01). The mean heart doses for the P-DIBH plans were <FB for 22 cases, the maximum dose was <FB for 18 cases. Conclusions: A DIBH plan delivered to a FB patient setup with surface imaging will yield dosimetry similar to that of a plan created and delivered FB. A DIBH plan delivered with even a partial BH can give reduced heart dose compared with FB techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reproducible Preparation of Au/TS-1 with High Reaction Rate for Gas Phase Epoxidation of Propylene

A refined and reliable synthesis procedure for Au/TS-1(Si/Ti molar ratio {approx}100) with high reaction rate for the direct gas phase epoxidation of propylene has been developed by studying the effects of pH of the gold slurry solution, mixing time, and preparation temperature for deposition precipitation (DP) of Au on TS-1 supports. Au/TS-1 catalysts prepared at optimal DP conditions (pH {approx} 7.3, mixing for 9.5 h, room temperature) showed an average PO rate {approx} 160 g{sub PO} h{sup -1} kg{sub Cat}{sup -1} at 200 C at 1 atm. A reproducibility better than {+-}10% was demonstrated by nine independent samples prepared at the same conditions. These are the highest rates yet reported at 200 C. No visible gold particles were observed by the HRTEM analysis in the fresh Au/TS-1 with gold loading up to {approx}0.1 wt%, indicating that the gold species were smaller than 1 nm. Additionally, the rate per gram of Au and the catalyst stability increased as the Au loading decreased, giving a maximum value of 500 g{sub PO} h{sup -1} g{sub Au}{sup -1}, and Si/Ti molar ratios of {approx}100 gave the highest rates.

42 ENGINEERING↗

Setup Reproducibility for Thoracic and Upper Gastrointestinal Radiation Therapy: Influence of Immobilization Method and On-Line Cone-Beam CT Guidance

We report the setup reproducibility of thoracic and upper gastrointestinal (UGI) radiotherapy (RT) patients for 2 immobilization methods evaluated through cone-beam computed tomography (CBCT) image guidance, and present planning target volume (PTV) margin calculations made on the basis of these observations. Daily CBCT images from 65 patients immobilized in a chestboard (CB) or evacuated cushion (EC) were registered to the planning CT using automatic bony anatomy registration. The standardized region-of-interest for matching was focused around vertebral bodies adjacent to tumor location. Discrepancies >3 mm between the CBCT and CT datasets were corrected before initiation of RT and verified with a second CBCT to assess residual error (usually taken after 90 s of the initial CBCT). Positional data were analyzed to evaluate the magnitude and frequencies of setup errors before and after correction. The setup distributions were slightly different for the CB (797 scans) and EC (757 scans) methods, and the probability of adjustment at a 3-mm action threshold was not significantly different (p = 0.47). Setup displacements >10 mm in any direction were observed in 10% of CB fractions and 16% of EC fractions (p = 0.0008). Residual error distributions after CBCT guidance were equivalent regardless of immobilization method. Using a published formula, the PTV margins for the CB were L/R, 3.3 mm; S/I, 3.5 mm; and A/P, 4.6 mm), and for EC they were L/R, 3.7 mm; S/I, 3.3 mm; and A/P, 4.6 mm. In the absence of image guidance, the CB slightly outperformed the EC in precision. CBCT allows reduction to a single immobilization system that can be chosen for efficiency, logistics, and cost. Image guidance allows for increased geometric precision and accuracy and supports a corresponding reduction in PTV margin.

61 RADIATION PROTECTION AND DOSIMETRY↗

An analytical solution of the solution-diffusion-electromigration equations reproduces trends in ion rejections during nanofiltration of mixed electrolytes

Here, this paper develops an analytical solution to the equations governing the solution-diffusion-electromigration transport of the ions from two salts that contain a common ion. The analytical expressions, which rely on constant ion permeances, readily enable simple spreadsheet computations of the permeate ion concentrations in nanofiltration (NF). Despite the model simplicity, calculations of ion rejections as a function of transmembrane volume fluxes, feed-solution compositions, and permeance values reproduce experimental trends, with ion permeances as the only adjustable parameters. For example, with solutions containing dissolved MA and M 2 B, when the membrane permeance to B 2– is much lower than the permeances to A – and M + , plots of A – rejection versus transmembrane volume flux show the negative minimum that is often characteristic of NF. Moreover, B 2– rejection increases with increasing MA in the feed solution, reflecting a decreasing electric field in the membrane. The analytical solution also enables spreadsheet computations of electric fields in membrane separation layers and effectively models experimental data for intrinsic rejections as a function of transmembrane volume flow. Interestingly, the model suggests that with sufficiently high permeances of A – (relative to M + ), at certain feed compositions the A – /B 2– selectivity may increase without bound as a function of volume flow. Otherwise, this selectivity does not vary greatly with feed composition and quickly reaches a limit as the volume flow increases. Despite the simplifying approximation of constant ion permeances, using only a few adjustable parameters this model readily reveals trends in NF ion rejections and may help to identify the desired ion permeances or solution compositions for specific separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗