Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL-TO-NOISE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A receiver design for the ATS-F radio beacon experiment.

The basic design of the overall receiving system is determined by the received power density from the satellite and the desired compromise between ground antenna aperture, system response times, and measurement signal-to-noise ratio. The measurement of Faraday rotation is discussed together with the measurement of modulation phase, aspects of system calibration, and overall system concepts.

Grubb, R. N.↗

The performance of a noncoherent FSK receiver preceded by a bandpass limiter.

Many applications of the bandpass limiter involve either coherent or noncoherent demodulation following the limiter. In this paper we study the performance of a noncoherent frequency-shift keying (FSK) receiver when it is preceded by a bandpass limiter. In particular, we obtain expressions for signal suppression factor, output signal-to-noise ratio (SNR), and error probability from which one can assess the degradation in performance of the receiver due to the presence of the limiter.

Simon, M. K.↗

Performance results of a digital test signal generator

Performance results of a digital test signal-generator hardware-demonstration unit are reported. Capabilities available include baseband and intermediate frequency (IF) spectrum generation, for which test results are provided. Repeatability in the setting of a given signal-to-noise ratio (SNR) when a baseband or an IF spectrum is being generated ranges from 0.01 dB at high SNR's or high data rates to 0.3 dB at low data rates or low SNR's. Baseband symbol SNR and carrier SNR (Pc/No) accuracies of 0.1 dB were verified with the built-in statistics circuitry. At low SNR's that accuracy remains to be fully verified. These results were confirmed with measurements from a demodulator synchronizer assembly for the baseband spectrum generation, and with a digital receiver (Pioneer 10 receiver) for the IF spectrum generation.

Gutierrez-Luaces, B. O.↗

Calibration of the receiver channel for the GOPEX precursor experiments

Calibration measurements for the cooled (253 K) photomultiplier tube (PMT) detector, used on the receiver channel of the transmit/receive (T/R) switch for GOPEX, were conducted in the laboratory. A pulsed frequency-doubled neodymium:yttrium-aluminum-garnet (Nd:YAG) laser was used to direct 532-mn light on the PMT. By monitoring the energy per pulse of the light incident on the PMT, the minimum number of photons detected could be determined. These results agreed with the photon flux back-calculated from the PMT output waveform. Approximately 700 incident photons arriving during a temporal pulse width of approximately 65 nsec were detected with a signal-to-noise ratio (SNR) of approximately 1. Other receiver channel characteristics, such as PMT dark currents, optical transmission, and interference filter sensitivity to angle of light incidence, were also measured.

Biswas, A.↗

Project Echo: System Calculations

The primary experimental objective of Project Echo was the transmission of radio communications between points on the earth by reflection from the balloon satellite. This paper describes system calculations made in preparation for the experiment and their adaptation to the problem of interpreting the results. The calculations include path loss computations, expected audio signal-to-noise ratios, and received signal strength based on orbital parameters.

Ruthroff, Clyde L.↗

Project Echo: FM Demodulators with Negative Feedback

The primary experimental objective of Project Echo was the transmission of radio communications between points on the earth by reflection from the balloon satellite. Owing to the large path losses from transmitter to receiver via the satellite, a wide-band frequency modulation technique was used in which bandwidth was traded for signal-to-noise ratio. This paper describes the FM receiving demodulators employed. Negative feedback applied to the local oscillator reduces the FM modulation index in the receiver IF amplifiers, resulting in threshold performance superior to that of conventional FM receivers.

Ruthroff, Clyde L.↗

The Aeolus-Earth DWTS Heliophysics Mission

The Aeolus-Earth Mission (DWTS-Helio) is a recently selected NASA Heliophysics investigation that will apply the innovative Doppler Wind Temperature Sounder (DWTS) technique to the Space Atmosphere Interaction Region (SAIR) at ~105-180 km. The technique, invented by Gordley & Marshall (2011), applies the Doppler Scanning with Gas Filter (DSGF) technique using a cryo-cooled MWIR radiometer to view the limb of the atmosphere from LEO (orbital velocity creates the Doppler shifts required by the technique). For this implementation of DWTS, a Nitric Oxide (NO) low pressure gas cell is used. The limb of the atmosphere is observed from a spacecraft at orbital velocity, and as an observed air volume passes through the field of view, this velocity creates a set of Doppler-shifted images. These images are used to create Doppler Integrated Pass (DIP) signals, from which atmospheric temperature and wind profiles are extracted (it may be considered a converse of the successful in-flight calibration of gas cells used for the HALOE instrument). The technique is relative, removing the need for absolute radiances, and the signal-to-noise ratio for this technique is high, resulting in good measurement precision. Different gas cells can be used to create different altitude coverage and may be combined to measure a more continuous altitude range. For example, using a NO cell captures the lower atmosphere from 30-50km as well as the SAIR, while using the 13 isotopologue of CO2 would capture 50-120km. Due to the desired data volume as well as power and thermal considerations, this initial Aeolus-Earth flight will be more suited for a ‘hosted’ payload on an Orbital Maneuvering Vehicle platform instead of the ‘free-flyer’ option originally investigated. Lastly, the technique is sufficiently powerful that a two-channel system could produce full Mars atmosphere data not currently possible.

DWTS↗

The Composite Spectrum of QSO Absorption Line Systems in DESI DR2

We present details regarding the construction of a composite spectrum of quasar (QSO) absorption line systems. In this composite spectrum we identify more than 70 absorption lines, and observe oxygen and hydrogen emission features at a higher signal-to-noise ratio than in any previous study. As the light from a distant quasar travels towards an observer, it may interact with the circumgalactic medium environment of an intervening galaxy, forming absorption lines. In order to maximize the signal of these absorption lines, we have selected a sample of 238,838 quasar spectra from the second data release of the Dark Energy Spectroscopic Instrument (DESI), each identified to have absorption lines resulting from such an interaction. By stacking these spectra in the restframe of the absorption, and calculating a median composite spectrum, we are able to isolate and enhance these absorption lines. We provide a full atlas of all detected absorption and emission lines as well as their fit centroids and equivalent width values. This atlas should aid in future studies investigating the compositions and physical conditions of these absorbers.

Napolitano, Lucas [Wyoming U.] (ORCID:000000025166↗

Detecting Process Equipment Failures Using Acoustic Data and Machine Learning

Nuclear power plant (NPP) process equipment such as fans, motors, valves, and pumps generate frequent or continuous noise, and deviations from the normal operational sounds made by this equipment can indicate potential issues. These deviations can be identified via automated acoustic anomaly detection, which involves using acoustic sensors (i.e., microphones) alongside detection algorithms to continuously monitor for changes in acoustic signatures. This task is made challenging by the substantial background noise that exists, such as operators opening and closing doors, manipulating valves, and conversing—in addition to typical plant noises. In collaboration with a nuclear power utility partner, this effort assessed the efficacy of acoustic anomaly detection when using a specific acoustic sensor that compresses data into a fixed set of features that are transferable over a standard Internet of Things communication protocol, thereby improving usability but potentially degrading detection performance. Two methods of performing automated acoustic anomaly detection were evaluated: one-class support vector machine (OC-SVM) and isolation forest (iForest). To enable the use of high-quality acoustic data encompassing both normal and anomalous conditions, the study utilized the publicly available Malfunctioning Industrial Machine Investigation and Inspection dataset, which includes real measured acoustic sensor data for a range of equipment types, model numbers, and signal-to-noise ratios (SNRs), along with a benchmark set of detection results. Using this dataset, the methods were tested and then compared against the benchmark results. The results indicated that although the specific acoustic sensor did not enable as rich a feature set extraction, the proposed methods with the limited feature set performed just as well. This provides solid justification for both the methods and the use of the proposed acoustic sensor.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Precision Kinematic Sunyaev--Zel'dovich Measurements Across Halo Mass and Redshift with DESI DR2 and ACT DR6: Part II. Bright Galaxy Survey and Emission-Line Galaxies

We present the first high-significance spectroscopic stacked kinetic Sunyaev-Zel'dovich (kSZ) measurements of circumgalactic gas profiles for both Bright Galaxy Survey (BGS) and Emission Line Galaxy (ELG) tracers, combining DESI Data Release 2 with ACT Data Release 6. Using reconstructed line-of-sight velocities from the DESI galaxies and high-resolution ACT temperature maps, we detect the kSZ signal at high significance, reaching signal-to-noise ratios of up to $\sim$9 for BGS and $\sim$7.5 for ELGs in optimal stellar-mass selections. Together with the LRG measurements presented in Paper I, these constitute the most significant kSZ detections from any spectroscopic survey to date. We perform the analysis in both real and harmonic space, obtaining consistent results. By splitting both tracers into stellar-mass bins, we study the scaling of the kSZ amplitude with galaxy properties. Combining the kSZ measurements with ACT Data Release 6 (DR6) CMB lensing maps enables a joint calibration of the galaxy-halo connection and the gas fractions of host halos. For the BGS galaxies, we observe low gas fractions around the virial radius relative to standard expectations, likely attributable to active galactic nuclei (AGN) activity. We find some evidence for higher-mass halos retaining a larger fraction of their baryons, consistent with more efficient feedback in lower-mass systems. For the ELG sample, dominated by blue, star-forming galaxies, we provide the first detection of the gas distribution in ELG host halos. The ELGs appear to exhibit relatively high gas fractions, which points to the possibility of weaker feedback (due to e.g. low AGN and supernova feedback activity) at their mass scale. Finally, we present generalized Navarro-Frenk-White (GNFW) fits to the harmonic-space measurements, providing a compact parametrization of gas profiles for forward modeling in large-scale structure analyses.

Hadzhiyska, B. [Cambridge U.; Cambridge U., Inst. ↗

Enhancing Unknown Waveform Detection by Learning Intra and Inter-domain Dependencies with Advanced Attention Fusion Mechanisms

Detection of unknown waveforms in mission-critical communications is a crucial area of interest for the Department of Energy (DoE). Traditional methods and recent deep learning-based approaches often assume that the training set includes all possible classes, which is impractical for detecting new waveforms. This limitation gives rise to the problem of open-set recognition (OSR), which involves correctly identifying known classes while detecting and rejecting unknown or unseen classes. To address this limitation, we propose a novel dual-domain complex-valued neural architecture that jointly processes time-domain and frequency-domain signal representations using transformer mechanisms. A transformer model is a deep learning architecture that uses self-attention mechanisms to process and learn relationships in sequential data. Our model employs a cosine similarity loss to extract domain-specific features and incorporates a transformer architecture in the latent space to weigh the importance of different features from the time and frequency domains. The transformer layer includes stacked self-attention and cross-attention modules to learn intra-domain and inter-domain dependencies, creating a more holistic signal representation. An attention-based fusion module intelligently combines the time and frequency-domain features using multi-head attention, enabling the network to learn the optimal feature for each domain in each input signal. Quantitative results demonstrate the impact of these architectural choices on overall performance, showing significant improvement after incorporating self and cross-attention modules and using complex attention fusion over simple weighted fusion. Our ongoing work will focus on addressing the limitations of threshold-based OSR methods by developing a novel generative framework that integrates a conditional diffusion probabilistic model (DPM). DPM is a generative framework that learns to synthesize complex data by reversing a gradual noising process using a neural network trained to denoise step-by-step. Our goal is to leverage the inherent strengths of DPMs for identifying unknown signals more robustly. One primary advantage of using a DPM is its ability to provide a more reliable anomaly score based on the model's reconstruction error, rather than relying solely on classifier confidence. Additionally, the iterative denoising process of DPMs makes this approach naturally resilient to low Signal-to-Noise Ratio (SNR) conditions, where traditional methods often fail. By implementing this generative framework, we aim to enhance the model's capability to accurately detect unknown waveforms and maintain performance in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

CMB Lensing Reconstruction Using Two Years of Temperature Data from the SPT-3G Summer Survey

We present the first reconstruction of the cosmic microwave background (CMB) lensing potential from the SPT-3G Summer survey using two years of temperature data. The Summer survey has a total area of approximately 2640 deg$^2$, split into three fields covering 1210, 570, and 860 deg$^2$, respectively. A joint analysis of the three Summer fields yields a lensing amplitude of $A^{\rm comb} = 1.015 \pm 0.053$ relative to a fiducial Planck 2018 $Λ$CDM cosmology for the multipole range $50 < L < 2000$. These early results from the SPT-3G Summer survey highlight the potential for increasing the signal-to-noise ratio when combining the Summer fields with the SPT-3G Main and Wide fields for a total SPT-3G survey area of $\sim$ 10,000 deg$^2$.

Levy, K. [Melbourne U.]↗

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Evaluation of a generalized least squares algorithm for infrasound beamforming with coherent background noise

Infrasonic signals of interest can occur during periods with persistent, coherent, background noise, which may be natural or anthropogenic. For high signal-to-noise (SNR) ratio transient signals, an ‘overprinting’ of the coherent background may occur, and the signal may still be detected. However, this approach fails for low SNR signals of interest, which may be obscured by coherent noise. An infrasound beamforming method based on generalized least squares (GLS) is investigated for detecting transient signals of interest in the presence of coherent and incoherent background noise. This approach relies on an estimate of the noise covariance, captured in a covariance matrix, to effectively null contributions to the array response from noisy directions of arrival. Synthetic array data is used to investigate the performance of the GLS beamformer compared to the Bartlett beamformer when coherent and incoherent backgrounds are present. Additionally, the effects of array element number and relative strength of the interfering signal on the GLS estimates is investigated. GLS empirical area under the curve estimates suggest that the beamformer can recover coherent power for a signal of interest lower in amplitude than the coherent background, but this effectiveness degrades more quickly with SNR for a four element array compared to a six or eight element infrasound array. Finally, infrasound from the Forensic Surface Experiment, a bolide signal observed at IMS array I37NO, and a volcanic signal recorded at the Alaska Volcano Observatory array ADKI are used to evaluate GLS performance on recorded data. A ten minute window was used to capture the background noise, and the coherent background signal was nulled in all three examples.

58 GEOSCIENCES↗

Forecasting the Ly-𝛼 forest × CMB lensing bispectrum from ACT, SO, S4, and DESI

We forecast the sensitivity of future correlations between cosmic microwave background (CMB) lensing and the Lyman-𝛼 forest power spectrum. This squeezed-limit bispectrum probes the connection between the Lyman-𝛼 transmission and the underlying large-scale matter density field. We recover the measured signal-to-noise (SNR) ratio obtained with Planck × BOSS, and forecast a SNR of 10.3, 14.8 and 20.2 for DESI combined with ACT, SO, and CMB-S4, respectively. For DESI and SO/CMB-S4, the correlation should be detectable at SNR ≥ 5 in 5 redshift bins, useful for distinguishing our signal from several contaminants. Indeed, our forecast is affected by large theoretical uncertainties in the current modeling of the signal and its contaminants, such as continuum misestimation bias or damped-Lyman-𝛼 absorbers. Quantifying these more accurately will be crucial to enable a reliable cosmological interpretation of this observable in future measurements. We attempt to enumerate the features required in future Lyman-𝛼 forest simulations required to do so.

Cosmic microwave background↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons↗