Search NASA⌕ Search

SEARCH · Search NASA

Results for “SNR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Spitzer Observations of Dust Destruction in the Puppis A Supernova Remnant

Imaging and spectral observations of the Puppis A supernova remnant (SNR) with the Spitzer Space Telescope confirm that its IR emission is dominated by the thermal continuum emission of swept-up interstellar dust which is collisionally heated by the X-ray emitting gas of the SNR. Line emission is too weak to affect the fluxes measured in broadband observations, and is poorly correlated with the IR or X-ray emission. Modeling of spectra from regions both in the SNR and in the associated ISM show that the ubiquitous polycyclic aromatic hydrocarbons (PAHs) of the ISM are destroyed within the SNR, along with nearly 25% of the mass of graphite and silicate dust grains.

Arendt, Richard G.↗

Recent Results on SNRs and PWNe from the Fermi Large Area Telescope

Topics include: Fermi LAT Collaboration groups; galactic results from LAT; a GeV, wide-field instrument; the 1FGL catalog, the Fermi LAT 1FGL source catalog, unidentified gamma-ray sources; variability in 1FGL sources; curvature in 1FGL sources; spectral-variability classification; gamma-ray pulsars and MSPs; GeV PWN - where to look; Crab pulsar and nebula; Vela X nebular of Vela pulsar; MSH 15-52; GeV PWNe spectra; GeV nebula limits; Nebula search of LAT pulsars; supernova remnants; SNR: GeV morphology; SNR: molecular connection; SNR: GeV breaks; SNR: young vs. old. The summary includes slides about the Large Area Telescope (LAT) and LAT sensitivity with time.

Hays, Elizabeth A.↗

Gamma-Ray Observations of the Supernova Remnant RX J0852.0-4622 with the Fermi Large Area Telescope

We report on gamma-ray observations of the supernova remnant (SNR) RX J0852.04622 with the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. In the Fermi-LAT data, we find a spatially extended source at the location of the SNR. The extension is consistent with the SNR size seen in other wavelengths such as X-rays and TeV gamma rays, leading to the identification of the gamma-ray source with the SNR. The spectrum is well described as a power law with a photon index of = 1.85 0.06 (stat)+0.18 0.19 (sys), which smoothly connects to the H.E.S.S. spectrum in the TeV energy band. We discuss the gamma-ray emission mechanism based on multiwavelength data. The broadband data can be fit well by a model in which the gamma rays are of hadronic origin. We also consider a scenario with inverse Compton scattering of electrons as the emission mechanism of the gamma rays. Although the leptonic model predicts a harder spectrum in the Fermi-LAT energy range, the model can fit the data considering the statistical and systematic errors.

Tanaka, T.↗

On-Orbit Noise Characterization of MODIS Reflective Solar Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS), launched on the Terra and Aqua spacecrafts, was designed to collect complementary and comprehensive measurements of the Earth's properties on a global scale. The 20 reflective solar bands (RSBs), covering a wavelength range from 0.41 to 2.1 micrometers, are calibrated on-orbit using regularly scheduled solar diffuser (SD) observations. Although primarily used for on-orbit gain derivation, the SD observations also facilitate the characterization of the detector signal-to-noise ratio (SNR). In addition to the calibration requirement of 2% for the reflectance factors and 5% for the radiances, the required SNRs are also specified for all RSB at their typical scene radiances. A methodology to characterize the on-orbit SNR for the MODIS RSB is presented. Overall performance shows that a majority of the RSB continue to meet the specification, therefore performing well. A temporal decrease in the SNR, observed in the short-wavelength bands, is attributed primarily to the decrease in their detector responses. With the exception of the inoperable and noisy detectors in band 6 identified prelaunch, the detectors of AquaMODIS RSB perform better than TerraMODIS. The approach formulated for on-orbit SNR characterization can also be used by other sensors that use on-board SDs for their on-orbit calibration (e.g., Suomi National Polar-Orbiting Partnership [SNPP]-Visible Infrared Imaging Radiometer Suite).

Reflective↗

The Role of Margin in Link Design and Optimization

Link analysis is a system engineering process in the design, development, and operation of communication systems and networks. Link models that are mathematical abstractions representing the useful signal power and the undesirable noise and attenuation effects (including weather effects if the signal path transverses through the atmosphere) that are integrated into the link budget calculation that provides the estimates of signal power and noise power at the receiver. Then the link margin is applied which attempts to counteract the fluctuations of the signal and noise power to ensure reliable data delivery from transmitter to receiver. (Link margin is dictated by the link margin policy or requirements.) A simple link budgeting approach assumes link parameters to be deterministic values typically adopted a rule-of-thumb policy of 3 dB link margin. This policy works for most S- and X-band links due to their insensitivity to weather effects. But for higher frequency links like Ka-band, Ku-band, and optical communication links, it is unclear if a 3 dB link margin would guarantee link closure. Statistical link analysis that adopted the 2-sigma or 3-sigma link margin incorporates link uncertainties in the sigma calculation. (The Deep Space Network (DSN) link margin policies are 2-sigma for downlink and 3-sigma for uplink.) The link reliability can therefore be quantified statistically even for higher frequency links. However in the current statistical link analysis approach, link reliability is only expressed as the likelihood of exceeding the signal-to-noise ratio (SNR) threshold that corresponds to a given bit-error-rate (BER) or frame-error-rate (FER) requirement. The method does not provide the true BER or FER estimate of the link with margin, or the required signalto-noise ratio (SNR) that would meet the BER or FER requirement in the statistical sense. In this paper, we perform in-depth analysis on the relationship between BER/FER requirement, operating SNR, and coding performance curve, in the case when the channel coherence time of link fluctuation is comparable or larger than the time duration of a codeword. We compute the "true" SNR design point that would meet the BER/FER requirement by taking into account the fluctuation of signal power and noise power at the receiver, and the shape of the coding performance curve. This analysis yields a number of valuable insights on the design choices of coding scheme and link margin for the reliable data delivery of a communication system - space and ground. We illustrate the aforementioned analysis using a number of standard NASA error-correcting codes.

Cheung, K.↗

New Identification of the Mixed-Morphology Supernova Remnant G298.6-0.0 with Possible Gamma-Ray Association

We present an X-ray analysis on the Galactic supernova remnant (SNR) G298.6−0.0 observed with Suzaku. The X-ray image shows a center-filled structure inside a radio shell, implying that this SNR can be categorized as a mixed-morphology (MM) SNR. The spectrum is well reproduced by a single-temperature plasma model in ionization equilibrium, with a temperature of 0.78 (0.70-0.87) keV. The total plasma mass of 30M indicates that the plasma has an interstellar medium origin. The association with a GeV gamma-ray source, 3FGL J1214.0−6236, on the shell of the SNR is discussed, in comparison with other MMSNRs with GeV gamma-ray associations. It is found that the flux ratio between absorption-corrected thermal X-rays and GeV gamma-rays decreases as the physical size of MMSNRs becomes larger. The absorption-corrected thermal X-ray flux of G298.6−0.0 and the GeV gamma-ray flux of 3FGL J1214.0−6236 closely follow this trend, implying that 3FGL J1214.0−6236 is likely to be a GeV counterpart of G298.6−0.0.

ISM: supernova remnants↗

Multispectral Snapshot Imagers Onboard Small Satellite Formations for Multi-Angular Remote Sensing

Multispectral snapshot imagers are capable of producing 2D spatial images with a single exposure at selected, numerous wavelengths using the same camera, therefore operate differently from push broom or whiskbroom imagers. They are payloads of choice in multi-angular, multi-spectral imaging missions that use small satellites flying in controlled formation, to retrieve Earth science measurements dependent on the targets Bidirectional Reflectance-Distribution Function (BRDF). Narrow fields of view are needed to capture images with moderate spatial resolution. This paper quantifies the dependencies of the imagers optical system, spectral elements and camera on the requirements of the formation mission and their impact on performance metrics such as spectral range, swath and signal to noise ratio (SNR). All variables and metrics have been generated from a comprehensive, payload design tool. The baseline optical parameters selected (diameter 7 cm, focal length 10.5 cm, pixel size 20 micron, field of view 1.15 deg) and snapshot imaging technologies are available. The spectral components shortlisted were waveguide spectrometers, acousto-optic tunable filters (AOTF), electronically actuated Fabry-Perot interferometers, and integral field spectrographs. Qualitative evaluation favored AOTFs because of their low weight, small size, and flight heritage. Quantitative analysis showed that waveguide spectrometers perform better in terms of achievable swath (10-90 km) and SNR (greater than 20) for 86 wavebands, but the data volume generated will need very high bandwidth communication to downlink. AOTFs meet the external data volume caps well as the minimum spectral (wavebands) and radiometric (SNR) requirements, therefore are found to be currently feasible in spite of lower swath and SNR.

Nag, Sreeja↗

Uncertainty Quantification for Empirical X-59 Sonic Boom Loudness Levels

Estimates of the total uncertainty for empirically determined loudness levels are documented when GRS (Ground Recording System) noise monitors are used to record X 59 sonic boom waveforms. The total uncertainty is characterized by combining nine different sources of uncertainty that may affect the apparent gain of the measurement chain. These uncertainty estimates are presented as expected measurement error relative to the true loudness level, and separate error estimates are provided for eight different noise metrics in which NASA has interest. The behavior of the Perceived Level (PL) metric is studied within the report body, while the total uncertainties for the seven other noise metrics are summarized in appendices for brevity. The effects of four sources of uncertainty are estimated simply from information found on hardware specification sheets provided by the manufacturer. However, mock acoustic recordings are created to estimate the effects of other sources because those effects are expected to induce spectral coloration, so they may vary with noise metric type and sound level. These sources are not well modeled by simple gain adjustments. Importantly, measurement error is computable when processing mock recordings since the true levels are knowable, which is not the case when processing data recorded in the field. Specifically, the true levels are knowable because the components of the mock recordings are separable – e.g., loudness levels of booms can be computed with or without superimposed background noise. Mock acoustic recordings also have the benefit of allowing analysis of sonic booms from vehicles that are not yet flying, like the X-59, since the mock recordings are created by combining vehicle-specific predicted waveforms with other audio sources. The estimates of total measurement error are documented as a function of the signal-to-noise ratio (SNR) of the loudness level, where the corrected SNR is computed while accounting for the effects of the method that is used to correct for background noise contamination when computing the noise metric values. The corrected SNR calculations used here can be applied to both mock recordings and in-field measurements, so the uncertainty of in-field recordings can be found using pre-computed lookup tables that identify the relationship between metric type, corrected SNR, and the expected measurement error.

Sonic Boom↗

Remote Sensing Low Signal-to-Noise-Ratio Target Detection Enhancement

In real-time remote sensing application, frames of data are continuously flowing into the processing system. The capability of detecting objects of interest and tracking them as they move is crucial to many critical surveillance and monitoring missions. Detecting small objects using remote sensors is an ongoing, challenging problem. Since object(s) are located far away from the sensor, the target’s Signal-to-Noise-Ratio (SNR) is low. The Limit of Detection (LOD) for remote sensors is bounded by what is observable on each image frame. In this paper, we present a new method, a “Multi-frame Moving Object Detection System (MMODS)”, to detect small, low SNR objects that are beyond what a human can observe in a single video frame. This is demonstrated by using simulated data where our technology-detected objects are as small as one pixel with a targeted SNR, close to 1:1. We also demonstrate a similar improvement using live data collected with a remote camera. The MMODS technology fills a major technology gap in remote sensing surveillance applications for small target detection. Our method does not require prior knowledge about the environment, pre-labeled targets, or training data to effectively detect and track slow- and fast-moving targets, regardless of the size or the distance.

47 OTHER INSTRUMENTATION↗

Seamless Data-Rate Change Using Punctured Convolutional Codes for a Time-Varying Signal-to-Noise Ratio

In a time-varying signal-to-noise-ratio (SNR) environment, symbol rate is changed to maximize data return. However, the symbol-rate changes may cause the receiver symbol loop to lose lock, thus losing real-time data. We propose an alternate way of varying the data rate in a seamless fashion by puncturing the convolutionally encoded symbol stream and transmitting the punctured encoded symbols with a constant symbol rate. We systematically searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We concluded that this scheme reduces the symbol-rate changes from 9 to 2 and provides a larger data return and a higher symbol SNR during most of the day.

SNR↗

New Evidence for Efficient Collisionless Heating of Electrons at the Reverse Shock of a Young Supernova Remnant

Although collisionless shocks are ubiquitous in astrophysics, certain key aspects of them are not well understood. In particular, the process known as collisionless electron heating, whereby electrons are rapidly energized at the shock front, is one of the main open issues in shock physics. Here, we present the first clear evidence for efficient collisionless electron heating at the reverse shock of Tycho's supernova remnant (SNR), revealed by Fe K diagnostics using high-quality X-ray data obtained by the Suzaku satellite. We detect K beta (3p yields 1s) fluorescence emission from low-ionization Fe ejecta excited by energetic thermal electrons at the reverse shock front, which peaks at a smaller radius than Fe K alpha (2p yields 1s) emission dominated by a relatively highly ionized component. Comparisons with our hydrodynamical simulations imply instantaneous electron heating to a temperature 1000 times higher than expected from Coulomb collisions alone. The unique environment of the reverse shock, which is propagating with a high Mach number into rarefied ejecta with a low magnetic field strength, puts strong constraints on the physical mechanism responsible for this heating and favors a cross-shock potential created by charge deflection at the shock front. Our sensitive observation also reveals that the reverse shock radius of this SNR is about 10% smaller than the previous measurement using the Fe K alpha morphology from the Chandra observations. Since strong Fe K beta fluorescence is expected only from low-ionization plasma where Fe ions still have many 3p electrons, this feature is key to diagnosing the plasma state and distribution of the immediate postshock ejecta in a young SNR.

Fe K diagnostics↗

Design and characterization of a single-channel microwave interferometer for the Helicon Physics Prototype eXperiment

A heterodyne interferometer for measuring the plasma electron density in Helicon Physics Prototype eXperiment (HPPX) has been developed and characterized in the laboratory. The heterodyne-type interferometer uses a probing beam of 85 GHz and a reference beam of 85.7 GHz by using two Gunn oscillators for facilitating frequency modulation. The cutoff density for this frequency is 8.96 x 10 19 m –3 that is much higher than the nominal electron density of the HPPX plasmas. The maximum deflection angle due to the refraction effect is estimated to be 0.63° assuming a parabolic electron density profile, and the impact on the measurement is negligible for the plasmas with a size of 100 mm. Two identical HDPE lenses act as the vacuum windows, and the lenses working together with the transmitter and receiver horns, form a beam with the beam waist of about 20 mm located at the plasma center. The characterization results of the lens and the critical microwave components show good performance. The plasma electron density measurement results are in line with the expectation. Furthermore, the Signal to Noise Ratio (SNR) of the measurement is defined as SNR = 20lg($\bar{n}_{e}$/S), where $\bar{n}_{e}$ and S are respectively the average electron density and the standard deviation of the signal, and the SNR is 80 dB. Finally, this demonstrates the system's capability of providing a clear and detailed density resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Convergent laser beam shapes: Unveiling the dynamics of Laser-induced elastic waves in composite materials

Overcoming the low signal-to-noise ratio (SNR) in laser ultrasonic testing of composite materials remains a significant challenge. Current efforts focus on enhancing SNR by inserting more energy into the material through temporal and/or spatial modulation of the laser beam. However, potential SNR improvements through wave convergence and wave energy manipulation have been overlooked. This paper addresses this gap by demonstrating the convergence of different wave types to a designated point and by showing the feasibility of directing absorbed laser energy into a specific wave type through spatial modulation of the laser beam. To achieve this, mathematical expressions for the convergent laser beams are derived. Various laser beam profiles are then introduced to the thermoelastic equations and solved using the finite element method. The sample under investigation is a transversely isotropic unidirectional carbon fiber reinforced plastic, characterized by anisotropic thermal expansion coefficients and thermal conductivities. Results reveal pronounced convergence of the intended wave type at the center due to laser beam shaping. This study showcases the ability to direct absorbed laser energy toward a specific wave type through spatial modulation of the laser beam and highlights the role of material anisotropy in energy focusing.

composite materials↗

Exploring Mission Design for Imaging Spectroscopy Retrievals for Land and Aquatic Ecosystems

The retrieval algorithms used for optical remote sensing satellite data to estimate Earth's geophysical properties have specific requirements for spatial resolution, temporal revisit, spectral range and resolution, and instrument signal-to-noise ratio (SNR) performance to meet biogeoscience objectives. Studies to estimate surface properties from hyperspectral data use a range of algorithms sensitive to various sources of spectroscopic uncertainty, which are in turn influenced by mission architecture choices. Retrieval algorithms vary across scientific fields and may be more or less sensitive to mission architecture choices that affect spectral, spatial, or temporal resolutions and spectrometer SNR. We used representative remote sensing algorithms across terrestrial and aquatic study domains to inform aspects of mission design that are most important for impacting accuracy in each scientific area. We simulated the propagation of uncertainties in the retrieval process including the effects of different instrument configuration choices. We found that retrieval accuracy and information content degrade consistently at >10 nm spectral resolution, >30 m spatial resolution, and >8-day revisit. In these studies, the noise reduction associated with lower spatial resolution improved accuracy vis à vis high spatial resolution measurements. The interplay between spatial resolution, temporal revisit, and SNR can be quantitatively assessed for imaging spectroscopy missions and used to identify key components of algorithm performance and mission observing criteria.

54 ENVIRONMENTAL SCIENCES↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Development of an MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete

Abstract Although contactless ultrasonic wavefield imaging shows potential for effective nondestructive inspection of various engineering materials, it has been rarely applied to concrete materials owing to technical challenges including low signal-to-noise ratio (SNR) caused by inherent heterogeneity of concrete. This paper presents development of a multi-channel MEMS ultrasonic microphone array system and its application to compressed wavefield imaging of concrete materials. The developed multi-channel MEMS ultrasonic microphone array system contains eight MEMS ultrasonic microphone elements and a signal conditioning circuit that enables measurements of ultrasonic signals with high SNR. A compressed sensing approach, based on the multiple measurement vector (MMV) concept, is applied to reconstruct a full dense ultrasonic wavefield data from sparsely sampled ultrasonic wavefield data. Experiments are carried out on a laboratory concrete sample to verify the performance of the developed MEMS microphone array system and proposed compressed sensing approach and then large-scale concrete samples to demonstrate practical application. The experimental results demonstrate that the developed MEMS microphone array system provides high-quality (SNR > 20 dB) ultrasonic data collected from concrete elements; furthermore, the proposed compressed sensing approach provides accurate reconstruction of dense wavefield data, as determined by peak signal-to-noise ratio (PSNR), from sparsely measured wavefield data with compression ratios up to 85% and PSNR above 25 dB in data collected form realistic large-scale concrete samples. By combining the MEMS array system and compressed sensing approach, the total ultrasonic data acquisition time needed to produce dense wavefield data can be significantly reduced.

Instruments & Instrumentation↗

Evaluation of a generalized least squares algorithm for infrasound beamforming with coherent background noise

Infrasonic signals of interest can occur during periods with persistent, coherent, background noise, which may be natural or anthropogenic. For high signal-to-noise (SNR) ratio transient signals, an ‘overprinting’ of the coherent background may occur, and the signal may still be detected. However, this approach fails for low SNR signals of interest, which may be obscured by coherent noise. An infrasound beamforming method based on generalized least squares (GLS) is investigated for detecting transient signals of interest in the presence of coherent and incoherent background noise. This approach relies on an estimate of the noise covariance, captured in a covariance matrix, to effectively null contributions to the array response from noisy directions of arrival. Synthetic array data is used to investigate the performance of the GLS beamformer compared to the Bartlett beamformer when coherent and incoherent backgrounds are present. Additionally, the effects of array element number and relative strength of the interfering signal on the GLS estimates is investigated. GLS empirical area under the curve estimates suggest that the beamformer can recover coherent power for a signal of interest lower in amplitude than the coherent background, but this effectiveness degrades more quickly with SNR for a four element array compared to a six or eight element infrasound array. Finally, infrasound from the Forensic Surface Experiment, a bolide signal observed at IMS array I37NO, and a volcanic signal recorded at the Alaska Volcano Observatory array ADKI are used to evaluate GLS performance on recorded data. A ten minute window was used to capture the background noise, and the coherent background signal was nulled in all three examples.

58 GEOSCIENCES↗

Forecasting the Ly-𝛼 forest × CMB lensing bispectrum from ACT, SO, S4, and DESI

We forecast the sensitivity of future correlations between cosmic microwave background (CMB) lensing and the Lyman-𝛼 forest power spectrum. This squeezed-limit bispectrum probes the connection between the Lyman-𝛼 transmission and the underlying large-scale matter density field. We recover the measured signal-to-noise (SNR) ratio obtained with Planck × BOSS, and forecast a SNR of 10.3, 14.8 and 20.2 for DESI combined with ACT, SO, and CMB-S4, respectively. For DESI and SO/CMB-S4, the correlation should be detectable at SNR ≥ 5 in 5 redshift bins, useful for distinguishing our signal from several contaminants. Indeed, our forecast is affected by large theoretical uncertainties in the current modeling of the signal and its contaminants, such as continuum misestimation bias or damped-Lyman-𝛼 absorbers. Quantifying these more accurately will be crucial to enable a reliable cosmological interpretation of this observable in future measurements. We attempt to enumerate the features required in future Lyman-𝛼 forest simulations required to do so.

Cosmic microwave background↗