Search NASA⌕ Search

SEARCH · Search NASA

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Next Generation Multi-Use Heavy-Duty High-Flow Direct-Fill Hydrogen Refueling Station with Standardized Design (CRADA Final Report)

The Contractor will build a liquid hydrogen (LH2) fueling station model that is capable of simulating the amount of hydrogen transferred from the liquid storage tank to the vehicle, depending on the station’s design and control scheme. This modeling work will allow the Parties to seek the design and control scheme of an LH2 station that can fill a targeted number of vehicles while meeting a time-average flow rate of 10 kg/min for each fill. While evaluating a high dispensing performance station design and control scheme, the Contractor will analyze the design and control scheme are economically viable.

08 HYDROGEN↗

Quantum key distribution using card, base station and trusted authority

Techniques and tools for quantum key distribution ("QKD") between a quantum communication ("QC") card, base station and trusted authority are described herein. In example implementations, a QC card contains a miniaturized QC transmitter and couples with a base station. The base station provides a network connection with the trusted authority and can also provide electric power to the QC card. When coupled to the base station, after authentication by the trusted authority, the QC card acquires keys through QKD with a trusted authority. The keys can be used to set up secure communication, for authentication, for access control, or for other purposes. The QC card can be implemented as part of a smart phone or other mobile computing device, or the QC card can be used as a fillgun for distribution of the keys.

97 MATHEMATICS AND COMPUTING↗

DISCRIMINATION CALIBRATION ANALYSIS METHODS FOR REGIONAL STATIONS

For event discrimination, operational implementation of a regional seismic station requires three sequential calibration analyses. 1) Magnitude, distance and amplitude corrections (MDAC) made to observed regional amplitudes are necessary so that what remains in the corrected amplitude is mostly information about the seismic source-type. Corrected amplitudes can be used in ratios to discriminate between earthquakes and explosions. Calibration of MDAC can be accomplished with empirical Bayes estimation, which naturally provides metrics to determine when adequate calibration data have been acquired, and provides statistical assurance that the errors associated with MDAC calibration are negligible in future operational discrimination analysis. 2) MDAC corrected amplitudes can then be used in ratios to discriminate between earthquakes and explosions. However, there remain source effects such as those due to depth, focal mechanism, local material property and apparent stress variability that cannot easily be determined and applied as amplitude corrections. We have developed a mathematical model to capture these near source effects as random (unknown) giving an error partition of three sources: model inadequacy, station noise and amplitude correlation. This mathematical model is the basis for a general multi-station regional discriminant. Calibration analysis for the standard error of the discriminant includes the calculation of the variances of model inadequacy and station noise, and amplitude correlation. 3) Likelihood-based seismic event identification analysis with MDAC discriminants requires estimated source population means and covariance matrices for the discriminants from each of the possible source types (e.g., deep earthquake, shallow earthquake, and explosion). Anderson et al. (2007) note that source population covariance matrices and the pooled covariance matrix are best estimated element-wise to fully utilize available calibration events. We propose an algorithm that may be used to mildly adjust an element-wise covariance matrix to ensure positive definiteness and non-singular behavior. The algorithm uses the Frobenius norm as the calibration metric because it minimally adjusts the variance terms of an element-wise covariance relative to the off-diagonal covariance terms to achieve a stable, positive semi-definite covariance matrix.

Anderson, Dale N.↗

Quantum key distribution using card, base station and trusted authority

Techniques and tools for quantum key distribution ("QKD") between a quantum communication ("QC") card, base station and trusted authority are described herein. In example implementations, a QC card contains a miniaturized QC transmitter and couples with a base station. The base station provides a network connection with the trusted authority and can also provide electric power to the QC card. When coupled to the base station, after authentication by the trusted authority, the QC card acquires keys through QKD with a trust authority. The keys can be used to set up secure communication, for authentication, for access control, or for other purposes. The QC card can be implemented as part of a smart phone or other mobile computing device, or the QC card can be used as a fillgun for distribution of the keys.

97 MATHEMATICS AND COMPUTING↗

Enhanced methods for operating refueling station tube-trailers to reduce refueling cost

A method and apparatus are provided for operating a refueling station including source tube-trailers and at least one compressor to reduce refueling cost. The refueling station includes a gaseous fuel supply source including a plurality of tanks on a tube trailer coupled to a first control unit, and high pressure buffer storage having predefined capacity coupled to a second control unit and the first tanks by a pressure control valve and the first control unit, and at least one compressor. The refueling station is operated at different modes depending on a state of the refueling station at the beginning of each operational mode. The refueling system is assessed at the end of each operational mode to identify the state of the system and select a next mode of operation. The operational modes include consolidating hydrogen, or any gaseous fuel, within the tubes mounted on the trailer.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Evaluating Direct and Indirect Influence on EV Charging Stations Across the US

The adoption of new technology for electric vehicles (EV) and mobility applications can bring underappreciated vulnerabilities to the power grid. One area of potential fraud and adversarial influence is through the business ecosystem of startups that own and deploy EV technology. Yet, there are no models or analyses that map the network of organizations and people that have direct and indirect influence over technologies currently deployed in the grid. To fill this gap, we develop a multilayer network model to measure direct and indirect influence on EV charging stations. First, we create and adversarial socio-technical network (ASTN) model via a data fusion pipeline for different US regions of interest (ROI). Then, we develop an integrated ASTN for Chicago, Los Angeles, New York, and Philadelphia. We rank EV charging companies direct influence within each geographic region as well as indirect influence via social network analysis. While some companies have strong direct and indirect influence (i.e., ChargePoint) others show a mismatch between their influence over charging stations and their position within the social network. For example, Tesla has strong direct influence on stations and weak indirect influence over competitors. In contrast, 7Charge has weak direct influence over stations, but strong indirect influence over competitors.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Brady's Geothermal Field - Map of DAS, Nodal, Vibroseis and Reftek Station Deployment

Map of DAS, nodal, vibroseis and Reftek stations during March 2016 deployment. The plot on the left has nodal stations labeled; the plot on the right has vibroseis observations labeled. Stations are shown in map-view using Brady's rotated X-Y coordinates with side plots denoting elevation with respect to the WGS84 ellipsoid. Blue circles denote vibroseis data, x symbols denote DAS (cyan for horizontal and magenta for vertical), black asterisks denote Reftek data, and red plus signs denote nodal data. This map can be found on UW-Madison's askja server at /PoroTomo/DATA/MAPS/Deployment_Stations.pdf

15 GEOTHERMAL ENERGY↗

Consumer Convenience and the Availability of Retail Stations as a Market Barrier for Alternative Fuel Vehicles: Preprint

The availability of retail stations can be a significant barrier to the adoption of alternative fuel light-duty vehicles in household markets. This is especially the case during early market growth when retail stations are likely to be sparse and when vehicles are dedicated in the sense that they can only be fuelled with a new alternative fuel. For some bi-fuel vehicles, which can also fuel with conventional gasoline or diesel, limited availability will not necessarily limit vehicle sales but can limit fuel use. The impact of limited availability on vehicle purchase decisions is largely a function of geographic coverage and consumer perception. In this paper we review previous attempts to quantify the value of availability and present results from two studies that rely upon distinct methodologies. The first study relies upon stated preference data from a discrete choice survey and the second relies upon a station clustering algorithm and a rational actor value of time framework. Results from the two studies provide an estimate of the discrepancy between stated preference cost penalties and a lower bound on potential revealed cost penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Advanced Hydrogen Fueling Protocols Can Improve Fueling Performance and H2 Station Design

This presentation introduces concepts to lower the cost of hydrogen fueling by making improvements to the existing SAE J2601 protocols and by utilizing completely new protocol approaches that can facilitate customer acceptable fueling at warmer hydrogen pre-cooling temperatures. These methods would reduce the cost of chillers at the station, reduce energy consumption, and increase station reliability without sacrificing fueling performance. These approaches are especially applicable to high flow fueling at 70 MPa, a key aspect of H2@Scale, wherein station energy consumption and customer sensitivity to fuel costs is even more prominent than it is for light-duty fueling.

ADVANCED PROPULSION SYSTEMS↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Operational optimization for multi-functional charging station with electric and hydrogen-powered vehicles

The rapid adoption of electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs), combined with global efforts to reduce carbon emissions, has accelerated the development of EV charging and hydrogen refueling stations. In response to this demand, this paper introduces the concept of Multi-Functional Charging Station (MFCS) that integrates power generation, EV charging, battery swapping, and hydrogen refueling. A comprehensive operational model is developed for the MFCS that couples electricity and hydrogen conversion and storage technologies to enhance infrastructure utilization and improve overall system efficiency. The model also considers multiple revenue streams, including participation in energy and ancillary markets. To validate the effectiveness of the proposed model and evaluate its performance, a series of numerical experiments are conducted with different charger numbers, different electricity purchase limits, and different charger allocations. Numerical results demonstrate that shared charger configurations can lead to 8.11 % improvement in operational profit by improving resource utilization and reducing the number of depleted batteries at the end of operations compared to allocated charger setups. By varying the number of chargers, sensitivity analysis identifies diminishing marginal returns beyond about 45 chargers, suggesting it as an optimal sizing point under current settings. The integration of electricity and hydrogen conversion is also explored under scenarios with limited external electricity purchases. In conclusion, these findings indicate that optimizing charger allocation and energy management can significantly enhance station productivity and profitability, ultimately supporting the broader adoption of electrified and hydrogen-based transportation solutions.

Charging station↗

Finding gaps in the national electric vehicle charging station coverage of the United States

Abstract The United States federal government has invested $7.5 billion into charging infrastructure, including the National Electric Vehicle Infrastructure Program, to build fast charging stations along designated highways for long-distance car travel. We develop a consecutive coverage metric to compute the percent of United States roads (traffic-weighted) that are consecutively accessible within 500 miles of each county. We answer (1) what the state of consecutive coverage is in each county and (2) what the increase in coverage is when designated highways receive fast chargers. In 2023, 10% of counties had at least 75% minimum viable coverage. We find that if all designated highways receive fast-charging stations, 94% of United States counties will reach at least 75% fast charger coverage. However, the remaining counties are rural. This demonstrates that federal funding for fast chargers will help connect most—but not all—counties to the national network of continuously accessible charging stations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a DC Fast Charging Station Model for Use with EV Infrastructure Projection Tool

The deployment of public charging infrastructure networks has been a major factor in enabling electric vehicle (EV) technology transition, and must continue to support the adoption of this technology. DC fast charging (DCFC) increases customer convenience by lowering charging time, enables long-distance EV travel, and could allow the electrification of high-mileage fleets. Yet, high capital costs and uneven power demand have been major challenges to the widespread deployment of DCFC stations. There is a need to better understand DCFC stations' loading, utilization, and customer service quality (i.e. queuing time, charging duration, and queue length). This study aims to analyze these aspects using one million vehicle-days of travel data within the Columbus, OH, region. Monte Carlo analysis is carried out in three types of areas - urban, suburban, and rural- to quantify the effect of uncertain parameters on DCFC station loading and service quality.

25 ENERGY STORAGE↗

Surrogate Modeling for Capacity Planning of Charging Station Equipped With Photovoltaic Panel and Hydropneumatic Energy Storage

Due to the promising potential for environmental sustainability, there has been a significant increase of electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEV) in the market. To support this increasing demand for EVs and PHEVs, challenges related to capacity planning and investment costs of public charging infrastructure must be addressed. Hence, in this paper, a capacity planning problem for charging stations is developed and aims to balance the current capital investment costs and future operational revenue. The charging station is assumed to be equipped with the solar photovoltaic (PV) panel and an energy storage system, which could be electric battery or recently invented hydropneumatic energy storage (ground-level integrated diverse energy storage (GLIDES)) system. A co-optimization model that minimizes investment and operation cost is established to determine optimal solution while considering capacity planning and following operations. EV mobility is modeled as an Erlang-loss system. Meanwhile, stochastic programming is adopted to capture uncertainties from solar radiation and charging demand of EV fleet. To provide a more general and computationally efficient model, main configuration parameters are sampled in design space and then fixed in solving the co-optimization model. Sampled parameters include EV charging slots number, PV area, capacity of energy storage system, and daily mean EV arrival number. Based on the sampled parameter combinations and its responses, black-box mappings are then constructed using surrogate models, which could provide insights for charging station placement in different practical situations. The effectiveness of the proposed surrogate modeling approach is demonstrated in numerical experiments. Here, the results indicate better profit advantage of GLIDES over battery system with the increased power capacity

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CROCUS Low Cost All-in-One Weather Station AMB-001 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-001), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-002 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-002), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗