Search NASA⌕ Search

SEARCH · Search NASA

Results for “STM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A modular ultra-high vacuum millikelvin scanning tunneling microscope

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our design is to achieve a high level of modularity by partitioning the STM system into a set of easily separable, interchangeable components. This naturally segregates the UHV needs of STM instrumentation from the typically non-UHV construction of a dilution refrigerator, facilitating the usage of non-UHV materials while maintaining a fully bakeable UHV chamber that houses the STM. Here, the modular design also permits speedy removal of the microscope head from the rest of the system, allowing for repairs, modifications, and even replacement of the entire microscope head to be made at any time without warming the cryostat or compromising the vacuum. Without using cryogenic filters, we measured an electron temperature of 184 mK on a superconducting Al(100) single crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigating the effect of electric fields on lead halide perovskites by scanning tunneling microscopy

Lead halide perovskites have emerged as promising absorber materials over the last decade to increase the efficiency of photovoltaics beyond its current limits. However, to further optimize the performance of perovskites, more detailed studies need to be performed which allow for the correlation of film morphology and local electronic properties at the nanoscale. In this paper, we present a scanning tunneling microscopy (STM) approach to probe the effect of an applied electric field of a methylammonium formamidinium lead triiodide perovskite thin film on the film response by current-voltage spectroscopy, current imaging tunneling spectroscopy, differential conductance mapping and X-ray absorption spectroscopy (XAS) by means of synchrotron X-ray STM (SX-STM). We find a strong correlation between the measurement conditions and the obtained current-voltage characteristics when imaging under opposite applied bias polarities. In particular, we find similarities to already observed poling effects for perovskites which result in either a positively or negatively charged interface due to ion and vacancy migration. Our results provide insight into the influence of measurement conditions such as bias polarity on the performance assessment of perovskite thin films by STM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Finding simplicity: unsupervised discovery of features, patterns, and order parameters via shift-invariant variational autoencoders *

Abstract Recent advances in scanning tunneling and transmission electron microscopies (STM and STEM) have allowed routine generation of large volumes of imaging data containing information on the structure and functionality of materials. The experimental data sets contain signatures of long-range phenomena such as physical order parameter fields, polarization, and strain gradients in STEM, or standing electronic waves and carrier-mediated exchange interactions in STM, all superimposed onto scanning system distortions and gradual changes of contrast due to drift and/or mis-tilt effects. Correspondingly, while the human eye can readily identify certain patterns in the images such as lattice periodicities, repeating structural elements, or microstructures, their automatic extraction and classification are highly non-trivial and universal pathways to accomplish such analyses are absent. We pose that the most distinctive elements of the patterns observed in STM and (S)TEM images are similarity and (almost-) periodicity, behaviors stemming directly from the parsimony of elementary atomic structures, superimposed on the gradual changes reflective of order parameter distributions. However, the discovery of these elements via global Fourier methods is non-trivial due to variability and lack of ideal discrete translation symmetry. To address this problem, we explore the shift-invariant variational autoencoders (shift-VAEs) that allow disentangling characteristic repeating features in the images, their variations, and shifts that inevitably occur when randomly sampling the image space. Shift-VAEs balance the uncertainty in the position of the object of interest with the uncertainty in shape reconstruction. This approach is illustrated for model 1D data, and further extended to synthetic and experimental STM and STEM 2D data. We further introduce an approach for training shift-VAEs that allows finding the latent variables that comport to known physical behavior. In this specific case, the condition is that the latent variable maps should be smooth on the length scale of the atomic lattice (as expected for physical order parameters), but other conditions can be imposed. The opportunities and limitations of the shift VAE analysis for pattern discovery are elucidated.

97 MATHEMATICS AND COMPUTING↗

Synthesis Structure and Imaging of Oligodeoxyribonucleotides with Tellurium-nucleobase Derivatization

We report here the first synthesis of 5-phenyl-telluride-thymidine derivatives and the Te-phosphoramidite. We also report here the synthesis, structure and STM current-imaging studies of DNA oligonucleotides containing the nucleobases (thymine) derivatized with 5-phenyl-telluride functionality (5-Te). Our results show that the 5-Te-DNA is stable, and that the Te-DNA duplex has the thermo-stability similar to the corresponding native duplex. The crystal structure indicates that the 5-Te-DNA duplex structure is virtually identical to the native one, and that the Te-modified T and native A interact similarly to the native T and A pair. Furthermore, while the corresponding native showed weak signals, the DNA duplex modified with electron-rich tellurium functionality showed strong topographic and current peaks by STM imaging, suggesting a potential strategy to directly image DNA without structural perturbation.

59 BASIC BIOLOGICAL SCIENCES↗

Fingerprints of composite fermion Lambda levels in scanning tunneling microscopy

A composite fermion (CF) is a topological quasiparticle that emerges from a nonperturbative attachment of vortices to electrons in strongly correlated two-dimensional materials. Similar to noninteracting fermions that form Landau levels in a magnetic field, CFs can fill analogous “Lambda” levels, giving rise to the fractional quantum Hall (FQH) effect of electrons. Here, we show that Lambda levels can be directly visualized through the characteristic peak structure in the signal obtained via spectroscopy with scanning tunneling microscopy (STM) on a FQH state. Complementary to transport, which probes the low-energy properties of CFs, we show that high-energy features in STM spectra can be interpreted in terms of Lambda levels. We numerically demonstrate that STM spectra can be accurately modeled using Jain's CF theory. Our results show that STM provides a powerful tool for revealing the anatomy of FQH states and identifying physics beyond the noninteracting CF paradigm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Universality of scanning tunneling microscopy in cuprate superconductors

We consider the problem of local tunneling into cuprate superconductors, combining model-based calculations for the superconducting order parameter with wave function information obtained from first-principles electronic structure. For some time it has been proposed that scanning tunneling microscopy (STM) spectra do not reflect the properties of the superconducting layer in the CuO 2 plane directly beneath the STM tip, but rather a weighted sum of spatially proximate states determined by the details of the tunneling process. These ``filter'' ideas have been countered with the argument that similar conductance patterns have been seen around impurities and charge ordered states in systems with atomically quite different barrier layers. Here we use a recently developed Wannier function-based method to calculate topographies, spectra, conductance maps, and normalized conductance maps close to impurities. We find that it is the local planar Cu d x 2 –y 2 Wannier function, qualitatively similar for many systems, that controls the form of the tunneling spectrum and the spatial patterns near perturbations. Furthermore we explain how, despite the fact that STM observables depend on the materials-specific details of the tunneling process and setup parameters, there is an overall universality in the qualitative features of conductance spectra. In particular, we discuss why STM results on Bi 2 Sr 2 CaCu 2 O 8 (BSCCO) and Ca 2–x Na x CuO 2 Cl 2 (NaCCOC) are essentially identical.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Etching sharp tips from thin metallic wires for tuning-fork-based scanning probe microscopy

Sharp tips are critical for obtaining high resolution images in scanning probe microscopy (SPM), particularly in samples with large variations in topography. For tuning-fork-based SPM, such tips are commonly obtained by electrochemical etching of metallic wires (e.g., tungsten). Electrochemical etching of metallic wires is the preferred means of preparing tips for scanning tunneling microscopy (STM), and techniques for obtaining sharp tips have been investigated extensively. However, the requirements for STM and tuning-fork-based SPM are different. In particular, the wires used in STM are typically 250-500 μ m in diameter, while the wires used for tuning-fork-based SPM are usually an order of magnitude narrower in order to minimize loading of the tuning fork: 25-50 μ m and sometimes down to a few micrometers in diameter. Consequently, many of the recipes developed for etching thicker metallic wires for STM tips do not give optimal results for smaller diameter wires. The authors describe here a modification of the etching circuit of Ibe et al . that significantly improves the reproducibility and reliability of the etching process for thin wires, and discuss the parameters that affect the aspect ratio of produced tips.

42 ENGINEERING↗

High signal-to-noise ratio differential conductance spectroscopy

The scanning tunneling microscope (STM) has enabled manipulation and interrogation of surfaces with atomic-scale resolution. Electronic information about a surface is obtained by combining the imaging capability of the STM with scanning tunneling spectroscopy, i.e., measurement of current-voltage (I/V) characteristics of the surface. We propose a change in the STM feedback loop that enables capturing a higher quality dI/dV image. A high frequency dither voltage is added to the bias voltage of the sample, and the fundamental frequency component of the resulting current is demodulated. The in-phase component of this signal is then plotted along with the X and Y position data, constructing the dI/dV image. Here, we show that by incorporating notch filters in the STM feedback loop, we may utilize a high-amplitude dither voltage to significantly improve the quality of the obtained dI/dV image.

42 ENGINEERING↗

A new approach to removing H atoms in hydrogen depassivation lithography

Hydrogen deppasivation lithography (HDL) carried out by a scanning tunneling microscope (STM) is used to make patterns of Si dimers on a hydrogen passivated silicon surface. In this paper we discuss a new STM mode of operation that is highly suitable for removing single H atoms from the surface. This is made possible by changes we have made to the STM feedback control system that allows the STM to remove hydrogen atoms without switching the operational mode from imaging to lithography. Employing this method can potentially reduce the chance of tip-sample crash and increase the lithography precision.

Moheimani, S. O. Reza↗

Magnification Effects in Scanning Tunneling Microscopy: the Role of Surface Radicals

Scanning tunneling microscopy (STM) is a fundamental tool for determination of the surface atomic structure. However, the interpretation of high resolution microscopy images is not straightforward. In this paper we provide a physical insight on how STM images can suggest atomic locations which are distinctively different from the real ones. This effect should be taken into account when interpreting high-resolution STM images obtained on surfaces with directional bonds. It is shown that spurious images are formed in the presence of polarized surface radicals showing a pronounced angle with respect to the surface normal. This issue has been overlooked within the surface science community and often disregarded by experimentalists working with STM. Without loss of generality, we illustrate this effect by the magnification observed for pentamer-like structures on (110), (113), and (331) surfaces of silicon and germanium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scholarly context not found: One in five articles suffers from reference rot

The emergence of the web has fundamentally affected most aspects of information communication, including scholarly communication. The immediacy that characterizes publishing information to the web, as well as accessing it, allows for a dramatic increase in the speed of dissemination of scholarly knowledge. But, the transition from a paper-based to a web-based scholarly communication system also poses challenges. In this paper, we focus on reference rot, the combination of link rot and content drift to which references to web resources included in Science, Technology, and Medicine (STM) articles are subject. We investigate the extent to which reference rot impacts the ability to revisit the web context that surrounds STM articles some time after their publication. We do so on the basis of a vast collection of articles from three corpora that span publication years 1997 to 2012. For over one million references to web resources extracted from over 3.5 million articles, we determine whether the HTTP URI is still responsive on the live web and whether web archives contain an archived snapshot representative of the state the referenced resource had at the time it was referenced. We observe that the fraction of articles containing references to web resources is growing steadily over time. We find one out of five STM articles suffering from reference rot, meaning it is impossible to revisit the web context that surrounds them some time after their publication. When only considering STM articles that contain references to web resources, this fraction increases to seven out of ten.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Spectroscopic Imaging of Molecular Functions at Surfaces

The focus of this project is on understanding the nature of intramolecular chemical bonds and intermolecular interactions using a unique technique developed in 2014 under DOE support: the inelastic tunneling probe (itProbe) with the scanning tunneling microscope (STM). By operating the STM at ~0.6 K, high energy resolution of ~0.6 meV is achieved, in combination with the inherent atomic scale spatial resolution of the STM. High energy and spatial resolutions of inelastic electron tunneling spectroscopy (IETS) with the STM enables itProbe to monitor energy shifts in the carbon monoxide (CO) hindered translational vibration as the CO-tip is scanned over an adsorbed molecule. Images are obtained that relate to the two-dimensional slices of the potential energy surface for different heights above the substrate, rendering a tomography of the molecule. Comparison of experimental results to density functional theory (DFT) calculations relates itProbe images to the potential energy surface of the CO-tip probing the potential of the adsorbed molecule. Results from this project provide information on the electronic, vibrational, and structural properties of single molecules, as well as how these properties relate to the reactivity, chemical sensing, self-assembly, and other chemical interactions of higher complexity. This research leads to new insights into the fundamental principles of chemistry that can be applied to the understanding of a broad range of phenomena, such as surface chemistry and catalysis, environmental processes and energy generation, electronic processing and electron transport through molecules as in molecular electronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upper ocean mixing, surface heat fluxes, and heat content variability in the upper 150 m during Hurricane Laura (2020)

Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.

Tsai, Senam↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

JOVE NASA-FIT program: Microgravity and aeronomy projects

This semi-annual status report is divided into two sections: Scanning Tunneling Microscopy Lab and Aeronomy Lab. The Scanning Tunneling Microscopy (STM) research involves studying solar cell materials using the STM built at Florida Tech using a portion of our initial Jove equipment funding. One result of the participation in the FSEC project will be to design and build an STM system which is portable. This could serve as a prototype STM system which might be used on the Space Shuttle during a Spacelab mission, or onboard the proposed Space Station. The scanning tunneling microscope is only able to image the surface structure of electrically conductive crystals; by building an atomic force microscope (AFM) the surface structure of any sample, regardless of its conductivity, will be able to be imaged. With regards to the Aeronomy Lab, a total of four different mesospheric oxygen emission codes were created to calculate the intensity along the line of sight of the shuttle observations for 2972A, Herzberg I, Herzberg II, and Chamberlain bands. The thermosphere-ionosphere coupling project was completed with two major accomplishments: collection of 500 data points on modulation of neutral wind with geophysical variables, and establishment of constraints on behavior of the height of the ionosphere as a result of interaction between geophysical and geometrical factors. The magnetotail plasma project has been centered around familiarization with the subject in the form of a literature search and preprocessing of IMP-8 data.

Patterson, James D.↗

An Initial Analysis of Automating Conjunction Assessment and Collision Avoidance Planning in Space Traffic Management

We introduce a framework that automates the process of assessing potential satellite conjunctions in space, and generating collision avoidance maneuvers to support mitigation efforts within a novel space traffic management (STM) architecture. A software implementation of the framework was developed in a MATLAB-STK integrated environment, however, the concept and framework is agnostic to the language or environment. The software pulls from existing catalogs of spaceborne objects and ingests user-defined parameters to produce conjunction data, which could potentially aid collision avoidance planning in the STM architecture. The utility of the software in maneuver planning and exploring a performance-based tradespace of actions is demonstrated using three example cases: one-to-one conjunction, one-versus-four conjunctions, and a near head-on collision. The framework also provides a test-bed for the use of application programming interfaces (APIs) to demonstrate machine-to-machine communication between entities in our proposed STM architecture. Results from this software implementation are expected to aid distributed decision-making among various stakeholders, and inform efficient, autonomous, structured but flexible concept of operations within STM.

Space Systems Engineering↗

Two-Color Ultrafast Photoexcited Scanning Tunneling Microscopy

We report on two-color two-photon photoexcitation of a metal surface driven by ultrafast laser pulses and detected with a scanning tunneling microscope (STM) tip as a proximate anode. Results are presented for two cases: (i) where the tip is retracted from the surface far enough to prohibit tunneling, and (ii) where the tip is within tunneling range of the surface. A delay-modulation technique is implemented to isolate the two-color photoemission from concurrent one-color two-photon photoemission and provide subpicosecond time-resolved detection. When applied with the tip in tunneling range, this approach effectively isolates the two-photon photoexcited current signal from the conventional tunneling current and enables subpicosecond time-resolved detection of the photoexcited surface electrons. The advantage of the two-color approach is highlighted by comparison with the one-color case where optical interference causes thermal modulation of the STM tip length, resulting in tunneling current modulations that are orders of magnitude larger than the current due to photoexcitation of surface electrons. By completely eliminating this interference, and thereby avoiding thermal modulation of the STM tip length, the two-color approach represents an important step toward the ultimate goal of simultaneous subnanometer and subpicosecond measurements of surface electron dynamics by ultrafast-laser-excited STM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lanthanum Bromide Detector System for Mu2e Stopping Target Monitor

The stopping target monitor (STM) in the Mu2e experiment is used to normalize the muon decay branching ratio in the Mu2e experiment, by estimating the number of muons that have been captured on the Mu2e nuclear target. The STM measures the distinctive muonic atomic transition lines and muonic nuclear excitations produced in the Aluminum Stopping Target of Mu2e. These signals must be disentangled in the presence of high rate Bremsstrahlung and other backgrounds produced in the target. An HPGe detector with fine energy resolution, ~0.1% will be employed but has limited count rate capability, ~20kcps. Time-to-Decision, that is the time to make an estimate of the experiments observed luminosity, is inversely proportional to the signal rate squared. For this reason the STM will also use a Lanthanum Bromide(LaBr3) detector, having ~2% energy resolution but capable of ~1 Mcps counting rate. This higher rate will allow not only an orthogonal verification of the HPGe luminosity measurements, but will also yield much finer luminosity measurements as a function of time because of its significantly higher counting rate capabilities. Geant4 simulations are presented comparing the performance of different sized, LaBr3 crystals. The results highly favor the use of the commercially available right circular cylindrical, 3x3-in. detector. Modifications to the STM design are discussed in order to take full advantage of the LaBr3 high rate and fast decision making capabilities. A preliminary design will be presented for a custom read-out system needed to fulfill these requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗