Open-loop nanosecond-synchronization for wideband satellite communications

A synchronization technique for use with an onboard processing satellite communication system is discussed. The satellite oscillator is used both as the system time reference and as the frequency source for all downlink carriers and data clocks. Downlink timing is established at each system earth terminal through a combination of carrier and data-clock tracking and a downlink timing epoch signal consisting of one bit per TDMA data burst. Uplink timing is established by an open-loop range prediction process using precision ephemerides calculated and distributed by the central control station. Overall timing accuracy of the uplink signal at the satellite receiver of + or - 7 nanoseconds permits unambiguous identification of each data bit position in a 128 Mbps TDMA burst. This is accomplished by means of simple, inexpensive terminal hardware using available crystal oscillators for time/frequency references and digital synthesis techniques that may be implemented in digital LSI chips.

Holmes, W. M., Jr.↗

Three-dimensional numerical simulation of thermal tides in the Martian atmosphere

Analysis of the Mariner 9 IRIS and Viking Orbiter IRTM temperature data and of the time series of surface pressure from the Viking landers has indicated that atmospheric thermal tides are a significant component of the martian general circulation. Classical tidal theory, considering only the Sun synchronous components, has been shown to at least roughly account for the amplitudes of the observed diurnal and semidirunal surface pressure oscillations. In particular, Zurek and Leovy have demonstrated that classical tidal theory can reproduce the observed dependence of the strength of the semidiurnal tide on aerosol optical depth. The high-amplitude topograph of Mars, however, can cause longitudinal distortions in the thermotidal forcing, leading to additional tidal modes that are not Sun synchronous. In particular, observation and theory have suggested the likely presence of a diurnal, zonal wavenumber-1 K wave. Hamilton and Garcia noted that the wavenumber-1 K normal mode has a period of close to 24 hr and may be detectable in surface pressure observations. Zurek has discussed the possibility of this mode being resonantly excited for various atmospheric temperature studies. The semidiurnal wavenumber-2 K mode, with roughly a 12-hr period, could also be resonantly excited. A numerical model with finite amplitude topography and a self-consistent thermotidal forcing resulting from the daily heat flux at the surface and atmospheric absorption of solar radiation by aerosols is used here to explore the influence of topography on martian thermal tides and to examine the possibility of Kelvin wave resonance.

Wilson, R. John↗

Curl up with a good B : detecting ultralight dark matter with differential magnetometry

Ultralight dark matter (such as kinetically mixed dark-photon dark matter or axionlike dark matter) can source an oscillating magnetic-field signal at the Earth’s surface, which can be measured by a synchronized array of ground-based magnetometers. The global signal of ultralight dark matter can be robustly predicted for low masses, when the wavelength of the dark matter is larger than the radius of the Earth, $λ_{DM}$ $\gg$ R. However, at higher masses, environmental effects, such as the Schumann resonances, can become relevant, making the global magnetic-field signal B difficult to reliably model. In this work, we show that ∇ × B is robust to global environmental details, and instead only depends on the local dark matter amplitude. We therefore propose to measure the local curl of the magnetic field at the Earth’s surface, as a means for detecting ultralight dark matter with $λ_{DM}$ ≲ R. As this measurement requires vertical gradients, it can be done near a hill/mountain. Our measurement scheme not only allows for a robust prediction, but also acts as a background rejection scheme for external noise sources. We show that our technique can be the most sensitive terrestrial probe of dark-photon dark matter for frequencies 10 Hz ≤ $f_{A'}$ ≤ 1 kHz (corresponding to masses 4 × 10 –14 eV ≤ $m_{A'}$ ≤ 4 × 10 –12 eV). It can also achieve sensitivities to axionlike dark matter comparable to the CAST helioscope, in the same frequency range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operation of the SUPARAMP at 33GHz

A 9mm degenerate parametric amplifier was constructed using a linear, series array of unbiased Josephson junctions as the active, nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable, net gain of 15 dB in an instantaneous bandwith (FWHM) of 3.4 GHz was achieved. A system noise temperature of 220 K + or - 5 K (DSB) was measured with a SUPARAMP contribution of only 20 K x or - 10 K. Output saturation was observed and complicates the interpretation of the noise temperature measurements and may render them upper limits. A comparison was made with the results of an earlier 3 cm suparamp. The data is in substantial agreement with theoretical predictions.

Chiao, R. Y.↗

Operation of the SUPARAMP at 33 GHz

A 9-mm degenerate parametric amplifier has been constructed using a linear series array of unbiased Josephson junctions as the active nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable net gain of 15 dB in an instantaneous bandwidth (FWHM) of 3.4 GHz has been achieved. A system noise temperature of 220 plus or minus 5 K (DSB) was measured with a SUPARAMP contribution of only 20 plus or minus 10 K. Output saturation has been observed. This complicates the interpretation of noise-temperature measurements and may render them upper limits. Comparison is made with the results of an earlier 3-cm SUPARAMP.

Chiao, R. Y.↗

Oscillation Risks of Grid-Following and Grid-Forming Inverter-Based Resources in Series-Compensated Networks

Here, this paper investigates the dynamic behavior of a grid-connected inverter-based resource (IBR) when connected radially to a series compensated line. Potential interactions between the series compensation and the IBR have been identified for both types: grid-following (GFL) or grid-forming (GFM). The study begins with electromagnetic transient (EMT) simulations to demonstrate stability issues. Subsequently, nonlinear analytical models are formulated in the dq frame, validated against the EMT simulation, and leveraged to assess eigenvalues and participation factors. Influencing factors of the dominant oscillation modes have been identified. The analysis results show that series compensation may make a mode associated with the synchronization unit unstable. Furthermore, customized feedback systems are built for the synchronizing loop. Series compensation can increase the sensitivity of the voltage phase angle towards the synchronizing angle, and introduce phase lag in the real power response towards the synchronizing angle. These factors may cause interactions with the phase-locked loop in GFL-IBR systems and with power-based synchronization in GFM-IBR systems, potentially leading to instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Phase Locked High Speed Real-Time Interferometry System for Large Amplitude Unsteady Flows

A high speed phase locked interferometry system has been designed and developed for real-time measurements of the dynamic stall flow over a pitching airfoil. Point diffraction interferograms of incipient flow separation over a sinusoidally oscillating airfoil have been obtained at rates of up to 20 KHz and for free stream Mach numbers of 0.3 and 0.45. The images were recorded on ASA 125 and ASA 400 film using a drum camera. Special electronic timing and synchronizing circuits were developed to trigger the laser light source from the camera, and to initiate acquisition of the interferogram sequence from any desired phase angle of oscillation. The airfoil instantaneous angle of attack data provided by an optical encoder was recorded via a FIFO and in EPROM into a microcomputer. The interferograms have been analyzed using software developed in-house to get quantitative flow density and pressure distributions.

Chandrasekhara, M. S.↗

The free-electron laser in a symmetrical confocal resonator

A tapered wiggler is used in a FEL oscillator to improve the saturation efficiency. During signal buildup the tapered wiggler does not provide optimum phase synchronism between the electron beam and the electromagnetic wave, resulting in an appreciable loss in small-signal gain. This problem can be ameliorated by using a multicomponent wiggler, which is a combination of a uniform wiggler and a tapered section. During buildup, gain is primarily contributed by the linear element, and at high power levels the gain and efficiency are enhanced by the taper. Ideally, one would like to have the optical waist location near the linear section at small-signal levels and at near the tapered section at high power levels. Placing the FEL in a symmetrical confocal resonator approaches this desired effect automatically since it has the unique characteristic that a stable mode exists for all locations of the waist of a Gaussian beam along the axis of the interferometer.

Ozcan, Meric↗

Coupling Light from a High-Q Microsphere Resonator Using a UV-induced Surface Grating

High-Q microspheres with whispering-gallery modes have very narrow resonances that can be used for fiber-optic filters, ultra-compact narrow-linewidth lasers and optical/microwave oscillators. Whispering-gallery modes were previously excited in microspheres using evanescent optical fields. The necessary phase synchronism was obtained by adjusting the incident angle of input light beam (prism coupler) or adjustment of the waveguide propagation constant (fiber taper coupler). For many applications, however, bulky near-field couplers are undesirable. They compromise the symmetry and generate stray fields. Also, the control of coupling is crucial for the performance of microsphere resonators: in analogy with radio frequency circuits, the loading Q-factor should be less than the intrinsic Q-factor, Q(sub L) less than or equal to Q(sub O). Ideally one should combine a stable coupling element and a resonator into a single microsphere component.

Ilchenko, V. S.↗

Synchronized frequency transposer

Transposer operates entirely in analog domain. Input analog signal is serially loaded into analog register at rate determined by voltage-controlled oscillator. At same time, signal is serially unloaded from other register at expanded time rate determined by divider output feeding through switch.

Sutton, J. F.↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators’ rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automatic frequency control for FM transmitter

An automatic frequency control circuit for an FM television transmitter is described. The frequency of the transmitter is sampled during what is termed the back porch portion of the horizontal synchronizing pulse which occurs during the retrace interval, the frequency sample compared with the frequency of a reference oscillator, and a correction applied to the frequency of the transmitter during this portion of the retrace interval.

Honnell, M. A.↗

An investigation of the use of discharge valves and an intake control for improving the performance of N.A.C.A. Roots type supercharger

This report presents the results of an analytical investigation on the practicability of using mechanically operated discharge valves in conjunction with a manually operated intake control for improving the performance of N. A. C. A. Roots type superchargers. These valves, which may be either of the oscillating or rotating type, are placed in the discharge opening of the supercharger and are so shaped and synchronized with the supercharger impellers that they do not open until the air has been compressed to the delivery pressure. The intake control limits the quantity of air compressed to engine requirements by permitting the excess air to escape from the compression chamber before compression begins. The percentage power saving and the actual horsepower saved were computed for altitudes from 0 to 20,000 feet. These computations are based on the pressure-volume cards for the conventional and the modified roots type superchargers and on the results of laboratory tests of the conventional type. The use of discharge valves shows a power saving of approximately 26 per cent at a critical altitude of 20,000 feet. In addition, these valves reduce the amplitude of the discharge pulsations and increase the volumetric efficiency. With slow-speed roots blowers operating at high-pressure differences even better results would be expected. For aircraft engine superchargers operating at high speeds these discharge valves increase the performance as above, but have the disadvantages of increasing the weight and of adding a high-speed mechanism to a simple machine. (author)

Schey, Oscar W↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation: Preprint

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators' rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

61 RADIATION PROTECTION AND DOSIMETRY↗

Self-stabilizing byzantine-fault-tolerant clock synchronization system and method

Systems and methods for rapid Byzantine-fault-tolerant self-stabilizing clock synchronization are provided. The systems and methods are based on a protocol comprising a state machine and a set of monitors that execute once every local oscillator tick. The protocol is independent of specific application specific requirements. The faults are assumed to be arbitrary and/or malicious. All timing measures of variables are based on the node's local clock and thus no central clock or externally generated pulse is used. Instances of the protocol are shown to tolerate bursts of transient failures and deterministically converge with a linear convergence time with respect to the synchronization period as predicted.

Malekpour, Mahyar R.↗