Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Sample Preparation Techniques for Grain Boundary Characterization of Annealed TRISO-Coated Particles

Crystallographic information about chemical vapor deposition layers of silicon carbide (SiC) is essential to understanding layer performance, especially when the layers are in non planar geometries, such as spherical. We performed electron Back Scatter Diffraction (EBSD) analysis of spherical SiC layers using a different approach to sample focus ion beam milling technique to avoid the negative impacts of traditional sample polishing and to address the need of very small samples of irradiated materials for analysis. Mechanical and chemical grinding and polishing of sample surfaces can introduce lattice strains and result in unequal removal of SiC and surrounding layers of different material due to the hardness differences of these materials. The nature of layer interfaces is thought to play a key role in performance of the SiC; therefore, analysis of representative samples at these interfacial areas is crucial. In work reported here, a focused ion beam (FIB) was employed in a novel manner to prepare a more representative sample for EBSD analysis from TRISO layers free of effects introduced by mechanical and chemical preparation methods. In addition, the difficulty of handling neutron irradiated microscopic samples such as those analyzed in this work has been simplified with pre tilted mounting stages. Our study showed that although the average grain size of samples may be similar, the grain boundary characteristics may differ significantly. It was also found that low angle grain boundaries, comprises 25% in the FIB-prepared sample vs only 1-2% in the polished sample measured in the same particle. From this study it was determined that results of FIB prepared sample will provide more repeatable results, as the role of sample preparation is eliminated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ENHANCEMENT OF ENVIRONMENTAL SAMPLING THROUGH AN IMPROVED AIR MONITORING TECHNIQUE

Environmental sampling (ES) is a key component of International Atomic Energy Agency (IAEA) safeguarding approaches throughout the world. Performance of ES (e.g. air, water, vegetation, sediments, soil and biota) supports the IAEAs mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a State and has been available since the introduction of safeguards strengthening measures approved by the IAEA Board of Governors (1992-1997). A recent step-change improvement in the gathering and analysis of air samples at uranium/plutonium bulk handling facilities is an important addition to the international nuclear safeguards inspector's toolkit. Utilizing commonly used equipment throughout the IAEA network of analytical laboratories for particle analysis, researchers are developing the next generation of ES equipment for air grab and constant samples. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) silicon substrate has been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. The new collection equipment will allow IAEA nuclear safeguards inspectors to develop enhanced safeguarding approaches for complicated facilities. This paper will explore the use of air monitoring to establish a baseline environmental signature of a particular facility that could be used for comparison of consistencies in declared operations. The implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Technical aspects of the air monitoring device and the analysis of its environmental samples will demonstrate the essential parameters required for successful application of the system.

54 ENVIRONMENTAL SCIENCES↗

Causal Analysis of the Unanticipated Extremity Exposure at HFEF

This report covers the unintended extremity exposure to an operator while handling a metallurgical mount sample of irradiated fuel following an off-scale high beta radiation reading of the sample. The decision was made to continue working after the meter indicated high off-scale by the HPT Supervisor, which resulted in the operator at the next operation being exposed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molybdenum and Uranium from Remote Continental Origin at Pico Summit, Pico Island, Azores, Portugal

The present study looks into aerosols collected by a land-based, seven-wavelength Aethalometer, from the lower-free troposphere close to the summit of the Pico mountain (top height: 2351 m; sampling height: 2225 m), in Pico island, Azores, Portugal. Following suitable handling and preparation procedures, all samples were put through instrumental neutron activation analysis (INAA; k{sub 0}-variant) for elemental assessment. Archival data have been used as an input to the HYSPLIT model (courtesy of NOAA ARL READY Website) for computing isentropic, backward trajectories of air masses reaching the Pico atmosphere. The results point to significant enrichments of molybdenum and uranium in high-altitude aerosols, especially in the summer samples. A local origin for either element is most unlikely though: Pico is a rural island, and there are no comparable records from low-altitude stations in the Azores at large. On the contrary, long-range transport from remote sources in continental areas--Europe and North-Central America--is rather compatible with the synoptic, elemental pathways converging over the Pico observatory for the period under study.

54 ENVIRONMENTAL SCIENCES↗

The Impact of Sampling Medium and Environment on Particle Morphology

Sampling on different substrates is commonly used in laboratory and field studies to investigate the morphology and mixing state of aerosol particles. Our focus was on the transformations that can occur to the collected particles during storage, handling, and analysis. Particle samples were prepared by electrostatic deposition of size-classified sodium chloride, sulfuric acid, and coated soot aerosols on different substrates. The samples were inspected by electron microscopy before and after exposure to various environments. For coated soot, the imaging results were compared against mass-mobility measurements of airborne particles that underwent similar treatments. The extent of sample alteration ranged from negligible to major, depending on the environment, substrate, and particle composition. We discussed the implications of our findings for cases where morphology and the mixing state of particles must be preserved, and cases where particle transformations are desirable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of a dry-gas meter for measuring air sample volumes in an ambient air monitoring network

Ambient air monitoring for non-research applications (e.g. compliance) occurs at locations throughout the world. Often, the air sampling systems employed for these purposes employee simple yet robust equipment capable of handling the rigors of demanding sampling schedules. At the Hanford Site (near Richland, Washington) concentrations of radionuclides in ambient air are monitored continuously at 44 locations. In 2004, mechanical dry-gas meters were incorporated into the Hanford Site ambient air sample collection system to allow the direct measurement of sample volumes. These meters replaced a portable airflow measurement system that required two manual flow measurements and a sample duration measurement to determine sample volume. A six-month evaluation of the dry-gas meters compared sample volumes calculated using the original flow rate method to the direct sample volume measurement (new method). The results of the evaluation indicate that use of the dry-gas meters result in accurate sample volume measurements and provide greater confidence in the measured sample volumes. In several years of in-network use, the meters have proven to be reliable and have resulted in an improved sampling system.

54 ENVIRONMENTAL SCIENCES↗

ChemCam investigation of the John Klein and Cumberland drill holes and tailings, Gale crater, Mars

The ChemCam instrument on the Mars Science Laboratory rover analyzed the rock surface, drill hole walls, tailings, and unprocessed and sieved dump piles to investigate chemical variations with depth in the first two martian drill holes and possible fractionation or segregation effects of the drilling and sample processing. Furthermore, the drill sites are both in Sheepbed Mudstone, the lowest exposed member of the Yellowknife Bay formation. Yellowknife Bay is composed of detrital basaltic materials in addition to clay minerals and an amorphous component. The drill tailings are a mixture of basaltic sediments and diagenetic material like calcium sulfate veins, while the shots on the drill site surface and walls of the drill holes are closer to those pure end members. The sediment dumped from the sample acquisition, processing, and handling subsystem is of similar composition to the tailings; however, due to the specifics of the drilling process the tailings and dump piles come from different depths within the hole. This then allows the ChemCam instrument to analyze samples representing the bulk composition from different depths. On the pre-drill surfaces, the Cumberland site has a greater amount of CaO and evidence for calcium sulfate veins, than the John Klein site. But, John Klein has a greater amount of calcium sulfate veins below the surface, as seen in mapping, drill hole wall analysis, and observations in the drill tailings and dump pile. In addition, the Cumberland site does not have any evidence of variations in bulk composition with depth down the drill hole, while the John Klein site has evidence for a greater amount of CaO (calcium sulfates) in the top portion of the hole compared to the middle section of the hole, where the drill sample was collected.

79 ASTRONOMY AND ASTROPHYSICS↗

High Thermal Conductivity Resin Systems for High Energy Physics Magnets

In Nb3Sn superconducting magnets, the cable and insulation system dominate the behavior of a completed magnet, with contributions to the mechanical behavior from the stiff, brittle components of the superconductor, the soft annealed copper stabilizer, and the properties of the composite insulation system. As these components are closely integrated on a small scale, it is of value to explore the properties of the entire system at a larger scale, to enable practical magnet design. Subscale composite testing (Stack Testing) has been used extensively to study the bulk material properties of the magnet composite structure. Small samples that mimic the fabrication process of magnets are fabricated and tested to qualify and characterize magnet insulation systems for use in future magnet projects as well as to better inform magnet designers about means for assembly and general handling processes. Subscale composite samples will be fabricated and characterized using various novel resins to work to improve magnet performance. New resin systems will be screened to allow for down selection to one or more highly promising resin systems. The work performed under this agreement at Fermilab will feed via CTD into the fabrication of subscale magnets at Lawrence Berkeley National Laboratory (LBNL) for verification of magnet performance.

43 PARTICLE ACCELERATORS↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

First Examination of Irradiated Fuel with Pulsed Neutrons at LANSCE (Preliminary Results)

We present preliminary results on the characterization of an irradiated U-lOZr-lPd fuel sample that was prepared from the irradiated AFC-3A-R5A sample. U-lOZr metallic fuels are researched as host materials for potential transmutation fuels and the addition of palladium strives to bind lanthanides, thus preventing fuel-cladding chemical interactions (FCCI). These interactions limit the lifetime of metallic fuels and are caused by migration of lanthanide fission products to the periphery of the fuel slug, where they start to interact with the D9 or HT9 steel cladding, ultimately leading to failure of the mechanical integrity of the cladding. Neutrons offer bulk characterization of irradiated materials for which X-ray tomography methods are not suitable due to the immense gamma background emitted from the samples. In particular pulsed neutrons provide information from the ability to resolve the neutron energy using their time-of-flight and thus the potential to utilize neutron absorption resonance to characterize the spatial distribution of isotopes. This, in turn, may allow to characterize the distribution of fission and neutron capture products non-destructively and may ultimately be applied to the bulk of an irradiation capsule prior to destructive post-irradiation examination to identify regions of interest. To allow the characterization of entire irradiation capsules, a cask is under development in the advanced post-irradiation work package at LANL and progress on this development was reported elsewhere. In parallel, an irradiated U-lOZr-lPd sample cut from the AFC-3AR5A irradiation was shipped to LANL and will be fully characterized with an NSUF funded rapid turnaround experiment (RTE) in the 2020 LANSCE run cycle. The sample emits at a dose rate of ~3R/hr on contact and is therefore manageable with remote handling, without requiring a cask. The disk-shaped material is larger than samples prepared for analysis using electron or X-ray methods and is therefore an intermediate step towards characterization of bulk samples at LANSCE. However, since it covers the full diameter of the irradiated fuel slug, some insight on redistribution of elements, spatially resolved information on microstructure, e.g. phase composition and texture, will be possible using the pulsed neutron-based methods developed for fuel characterization at LANSCE. This report describes the development of procedures to handle the sample at LANSCE as well as preliminary data and results from tests conducted in December 2019 on the energy-resolved neutron imaging (ERNI) beam line at flight path 5 and the high pressure-preferred orientation diffractometer (HIPPO) at LANSCE. This effort is a collaboration between LANL, INL, and ORNL. To compare our capabilities with prior work, we present an overview of previously reported bulk characterization of irradiated or spent fuels. The overview addresses neutron diffraction and neutron absorption resonance spectroscopy, both of which have only few reported applications on irradiated or spent nuclear fuel, as well as neutron radiography. This literature review was already described in a previous report but is repeated here to put our current efforts in context of previous work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent results of the investigation of a micro-fluidic sampling chip and sampling system for hot cell aqueous processing streams

A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and micro-fluidic sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. Different sampling volumes have been tested. It appears that the 10 μl volume has produced data that had much smaller relative standard deviations than the 2 μl volume. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The micro-fluidic-based robotic sampling system's mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of micro-fluidic sampling chips. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Soluble and Particulate Mercury Deployment of Analytical Method for the Savannah River Site Liquid Waste System

Savannah River National Laboratory (SRNL) developed, tested, and deployed in a radiological containment unit (CU) an analytical method for quantifying particulate total mercury and soluble total mercury in radioactive samples such as the those generated by the dilution of Savannah River Site (SRS) High-Level Waste. This method relies on direct mercury analysis and other associated capabilities for matrix independent quantification of total mercury in solids or liquids (i.e., any sample that can be introduced into the instrument oven for pyrolysis to release all mercury for measurement). The matrix independence allows for discreet measurements of the starting sample, the collected particulates and the filtrate liquid, thus enabling a mass balance quality check. For example, an analysis of a diluted sample from the SRS liquid waste system (LWS) resulted in a measured total mercury value of 55.0 mg Hg/L and a nearly matching calculated total mercury value of 55.1 mg Hg/L (± 20% 2σ) from the summation of measured soluble mercury (47.8 mg Hg/L ± 20% 2σ) and measured particulate mercury (7.26 mg Hg/L ± 20% 2σ). The advantages of the particulate-soluble mercury analysis method are: waste minimization using small radioactive liquid volumes, minimal radiological sample processing and reduced handling steps protective of workers (ALARA) and improved data quality, syringe filter technology which eliminates vacuum filtration and the potential loss of volatile species, small diameter filters (13 mm nominal to 25 mm if needed to avoid clogging) and small disposable poly filter holders (no need to clean) which minimize waste, flexibility provided for a range of starting concentrations, particulate-soluble ratios, and sample matrix conditions, soluble and particulate are measured results that, when summed, and are in good agreement with the total mercury measurement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remotely Operated Equipment for Post Irradiation Examination of the SNS Target Vessel

The Spallation Neutron Source produces neutrons by accelerating protons into flowing mercury contained inside a stainless steel target vessel. During facility operation the target vessel is degraded by a combination of high-energy neutrons, the proton beam, and cavitation-induced corrosion. The degradation is primarily concentrated at the nose of the target vessel, where the proton beam passes through. Currently, the Spallation Neutron Source has replaced three target vessels and is operating the fourth. To minimize the operational costs of manufacturing and disposing of target vessels, efforts are underway to increase the operational lifetimes of the target vessels by conducting post irradiation examinations of spent vessels. This examination involves remotely removing multiple coupons from the nose of the target vessel using a single piece of equipment, called the Nose Sampling Cutter, installed inside the Spallation Neutron Source s hot cell. The Cutter produces circular coupons approximately 2 inches in diameter using a carbide-tipped hole saw. The nose of the target vessel consists of four layers of material, and the Nose Sampling Cutter is capable of cutting through the layers in a single stroke. This remote operation has been successfully completed twice. In addition to the Nose Sampling Cutter, a large reciprocation saw capable of removing a sizable section of the nose of the target vessel has been constructed and tested, but never implemented. To support this large reciprocation saw other equipment has also been designed. The details of the Nose Sampling Cutter, reciprocation saw, and associated equipment are discussed.

36 MATERIALS SCIENCE↗

Microstructure Characterization of RERTR Fuel

A variety of phases have the potential to develop in the irradiated fuels for the reduced enrichment research test reactor (RERTR) program. To study the radiation stability of these potential phases, three depleted uranium alloys were cast. The phases of interest were identified including U(Si,Al)3, (U,Mo)(Si,Al)3, UMo2Al20, UAl4, and U6Mo4Al43. These alloys were irradiated with 2.6 MeV protons at 200ºC up to 3.0 dpa. The microstructure is characterized using SEM and TEM. Microstructural characterization for an archive dispersion fuel plate (U-7Mo fuel particles in Al-2%Si cladding) was also carried out. TEM sample preparation for the irradiated dispersion fuel has been developed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pre-Viking Swedish Hillfort Glass: A Prospective Long-Term Alteration Analogue for Vitrified Nuclear Waste

Examining ancient anthropogenic glasses altered in natural environments over hundreds of years can inform and verify models for predicting long-term rates of glass corrosion. Understanding corrosion mechanisms is critical for modeling the performance of nuclear waste glasses that are required to retain radionuclides for >1000 years, and will be disposed in shallow subsurface environments. Two types of ancient Swedish hillfort glasses — one clear, iron-poor glass, and one dark, iron-rich glass — have been characterized to evaluate their use as long-term alteration analogues for vitrified nuclear waste disposed under near-surface conditions. These glasses are of interest to the nuclear waste glass community as they have comparable elemental compositions to glasses under development for disposal of nuclear waste at the Hanford Site, USA. They are also of historical importance to Sweden; thus, an analysis protocol, focusing on non-destructive to semi-destructive analyses, has been developed to maintain the historical integrity of the samples. X-ray computed tomography, micro X-ray diffraction, micro X-ray fluorescence, and electron microscopy data are presented for both vitreous and mineralogical components of the hillfort samples. The internal microstructure and elemental distribution of the glasses, including the presence of crystalline inclusions, are discussed in the context of ancient glassmaking technology.

Weaver, Jamie L.↗

Advanced Retrieval Demonstrations of the Hanford Waste End Effector - 19383

This paper describes advanced retrieval demonstrations of the Hanford Waste End Effector (HWEE) at the Washington River Protection Solutions (WRPS) Cold Test Facility conducted by Pacific Northwest National Laboratory (PNNL) in co-operation with the U.S. Department of Energy - Office of River Protection and WRPS. The HWEE is a water-based scarifier originally developed by PNNL for the U.S. Department of Energy tank retrieval systems in the 1990's as the confined sluicing end effector and later used with additional development in the waste retrieval of tanks at Oak Ridge National Laboratory. The HWEE is being assessed for potential use in Hanford tank retrievals because it is expected to use less water during waste retrieval than other water-based methods (e.g., sluicing) previously used in Hanford tanks. This is primarily because the HWEE uses three rotating high-pressure jets for dislodging the waste and a high-velocity conveyance system to retrieve the water and the waste locally at the point of waste dislodging. The retrieval demonstrations build on previous development testing (Phase I) completed in 2017 by addressing key tank waste challenges, including retrieval of a mixed layered simulant and retrieval of uneven simulant profiles like that found near tank walls. The tests involved retrieval of water and kaolin (sludge) simulant to determine pumping rate, dilution factors, and a demonstration of vertical pumping capability. Upgrades to the HWEE for Phase II testing included a more robust inlet screen, internal flush jet modification for lower water usage, and removal of the external flush mole that was not used during Phase I retrieval testing. In addition, a rotational positioning capability was added to the three-dimensional gantry to gain additional movement capability and flexibility needed to implement more complex retrieval mining techniques. Two simulant configuration options using existing simulant materials were defined to represent key Hanford tank waste properties: 1) layered waste (e.g., strong crust over weaker sediment) and 2) topography that is representative of tank waste (uneven surface). Historical information from Hanford waste, including tank history, sampling reports, and images, was investigated to define the simulant characteristics and physical configuration. Using the layered simulant configuration, retrieval tests focused on demonstrating the same operational parameters irrespective of simulant strength. The focus of the topographical retrieval test was to demonstrate the ability to clean next to the tank wall using a tilted HWEE and to demonstrate water confinement using a specific mining strategy. This paper will describe the Phase II test equipment, instrumentation, simulant preparation procedures, and testing methodology. Testing results that will be presented include HWEE water usage versus operating pressure, simulant characterization data, dilution ratios, and retrieval rates. Reaction forces and other factors that would affect the remote operation of the HWEE will also be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-CHIP: an integrated platform for high-throughput protein crystallization and on-the-chip X-ray diffraction data collection

The X-CHIP (X-ray Crystallization High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The system has been designed for crystallization condition screening, visual crystal inspection, initial X-ray screening and data collection in a high-throughput fashion. X-ray diffraction data acquisition can be performed directly on-the-chip at room temperature using an in situ approach. The capabilities of the chip eliminate the necessity for manual crystal handling and cryoprotection of crystal samples, while allowing data collection from multiple crystals in the same drop. This technology would be especially beneficial for projects with large volumes of data, such as protein-complex studies and fragment-based screening. The platform employs hydrophilic and hydrophobic concentric ring surfaces on a miniature plate transparent to visible light and X-rays to create a well defined and stable microbatch crystallization environment. The results of crystallization and data-collection experiments demonstrate that high-quality well diffracting crystals can be grown and high-resolution diffraction data sets can be collected using this technology. Furthermore, the quality of a single-wavelength anomalous dispersion data set collected with the X-CHIP at room temperature was sufficient to generate interpretable electron-density maps. This technology is highly resource-efficient owing to the use of nanolitre-scale drop volumes. It does not require any modification for most in-house and synchrotron beamline systems and offers a promising opportunity for full automation of the X-ray structure-determination process.

59 BASIC BIOLOGICAL SCIENCES↗

Formed Core Sampler Hydraulic Conductivity Testing

A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposed to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗