Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Hard X-ray astrophysics

Past hard X-ray and lower energy satellite instruments are reviewed and it is shown that observation above 20 keV and up to hundreds of keV can provide much valuable information on the astrophysics of cosmic sources. To calculate possible sensitivities of future arrays, the efficiencies of a one-atmosphere inch gas counter (the HEAO-1 A-2 xenon filled HED3) and a 3 mm phoswich scintillator (the HEAO-1 A-4 Na1 LED1) were compared. Above 15 keV, the scintillator was more efficient. In a similar comparison, the sensitivity of germanium detectors did not differ much from that of the scintillators, except at high energies where the sensitivity would remain flat and not rise with loss of efficiency. Questions to be addressed concerning the physics of active galaxies and the diffuse radiation background, black holes, radio pulsars, X-ray pulsars, and galactic clusters are examined.

Rothschild, R. E.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard X-rays

In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle.

Desai, U. D.↗

A burst of energetic gamma rays

A burst of gamma rays with energies greater than 1 MeV occurring on May 14, 1972, at 201247 UT (151247 local time) was detected during a balloon flight from Palestine, Texas, at a float altitude of 4g/sq cm residual atmosphere. The detector was a tank of liquid scintillator 1m x 0.5 m x 15 cm surrounded by a 0.6 cm plastic scintillator in anticoincidence. The signal was 60 standard deviations above a steady background of 600 counts/sec. The flux was 0.12 (+0.07 or -0.04) gamma/sq cm, and the time integrated flux 20(+11 or -7) gamma/sq cm. Only one such event was seen during the 8 hours of observation in the daytime on May 14 and 15. Two sub-flares in H alpha occurred during the burst, but not coincident with the start time. A detector on the Solrad satellite observed X-rays on all channels 2 minutes after the gamma ray start time. This event is similar to three earlier reported events.

Koga, R.↗

The cosmic gamma-ray spectrum between 0.3 and 27 MeV measured on the Apollo 15

The spectrum of the total (diffuse and discrete sources) cosmic gamma-ray background over the 0.3 to 27 MeV range was measured with a 7.0 cm diameter x 7.0 cm long uncollimated NaI(Tl) scintillation counter located on a boom 7.6 m from the Apollo 15 service module. Data on cosmic gamma-rays were taken during transearth coast at various boom extensions, detector gains, and with the plastic anticoincidence scintillator enabled and disabled.

Trombka, J. I.↗

Large area ion chambers for a high energy cosmic ray experiment

High resolution measurement of the iron group nuclei was performed with the intention of determining individual abundances in the cosmic ray flux at the earth of particles with z = 22 to 30. Of the three types of dE/dx detectors used in the experiment, pulse ion chambers, Cerenkov radiators and scintillators, the first has the best z resolution over a wide range of particle z and energy. The plastic scintillators define the particle acceptance cone of the telescope while the Cerenkov detector aids in rejection of low energy particle background and measurement of particle velocity.

Source record↗

Studies of air showers produced by primaries 10(16) eV using a combined scintillation and water-Cerenkov array

An array of 8 x 1.0 sq m plastic scintillation counters and 13 water-Cerenkov detectors (1 to 13.5 sq m) were operated at the center of the Haverah Park array to study some features of air showers produced by 10(16) eV primaries. Measurements of the scintillator lateral distribution function, the water-Cerenkov lateral distribution function, and of the distance dependence of the Cerenkov/scintillator ratio are described.

Brooke, G.↗

A mercuric iodide detector system for X-ray astronomy. II - Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, described by Ricker et al., an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, TX. The second flight of this instrument established a differential background counting rate of 4.2 + or - 0.7 x 10 to the -5th counts/s sq cm keV over the energy range of 40-80 keV. This measurement was within 50 percent of the predicted value. The measured rate is about 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range.

Vallerga, J. V.↗

Detectors for energies greater than 10 MeV

The detector telescopes used in gamma ray astronomy in general are more similar to particle detectors than to optical devices, since the high frequency of the radiation precludes the use of reflection or diffraction techniques, but the high energy content of each photon does enable them to be detected with scintillators, track imaging chambers, and solid state detectors. Within the gamma ray range, the basic design of the instrument changes as the energy of the gamma ray exceeds 10 to 20 MeV, and therefore, moves from the region where the Compton effect predominates in the absorption of the gamma ray to that where electron pair production is most important. In the energy range from 10 to 20 MeV to several times 10,000 MeV, gamma ray telescopes are usually built so that the electron pair may be seen and the properties of the electrons measured.

Source record↗

New concepts for HgI2 scintillator gamma ray spectroscopy

The primary goals of this project are development of the technology for HgI2 photodetectors (PD's), development of a HgI2/scintillator gamma detector, development of electronics, and development of a prototype gamma spectrometer. Work on the HgI2 PD's involved HgI2 purification and crystal growth, detector surface and electrical contact studies, PD structure optimization, encapsulation and packaging, and testing. Work on the HgI2/scintillator gamma detector involved a study of the optical - mechanical coupling for the optimization of CsI(Tl)/HgI2 gamma ray detectors and determination of the relationship between resolution versus scintillator type and size. The development of the electronics focused on low noise amplification circuits using different preamp input FET's and the use of a coincidence technique to maximize the signal, minimize the noise contribution in the gamma spectra, and improve the overall system resolution.

Iwanczyk, Jan S.↗

Mercuric iodine room temperature gamma-ray detectors

high resolution mercuric iodide room temperature gamma-ray detectors have excellent potential as an essential component of space instruments to be used for high energy astrophysics. Mercuric iodide detectors are being developed both as photodetectors used in combination with scintillation crystals to detect gamma-rays, and as direct gamma-ray detectors. These detectors are highly radiation damage resistant. The list of applications includes gamma-ray burst detection, gamma-ray line astronomy, solar flare studies, and elemental analysis.

Patt, Bradley E.↗

Construction of a cosmic ray air shower telescope

The telescope under construction is mainly for the purpose of locating the arrival directions of energetic particles and quanta which generate air showers of sizes 10 to the 5th power to 10 to the 6th power. Both fast timing method and visual track method are incorporated in determining the arrival directions. The telescope is composed of four stations using scintillators and neon flash tubes as detectors. The system directional resolution is better than 1.5 deg.

Ng, L. K.↗

Cosmic-ray elemental abundances from 1 to 10 GeV per amu for boron through nickel

The relative abundances of cosmic-ray nuclei in the charge range boron through nickel over the energy range 1-10 GeV per amu were measured with a balloon-borne detector. The instrument consists of a scintillation and Cerenkov counter telescope with a multiwire proportional chamber hodoscope and has been flown in four high-altitude balloon flights. Good charge resolution (sigma = 0.2 charge units at iron) and high statistical accuracy have been achieved. These data are used to derive the energy dependence of the leakage path length using the leaky box model of propagation and confinement in the galaxy. This energy dependence is found to be best fit by lambda = E(tot) exp -n, where n = 0.49 + or - 0.06 over 1-10 GeV per amu. Relative abundances at the source are consistent with an energy-independent composition.

Dwyer, Robert↗

The solar X-ray/cosmic gamma-ray burst experiment aboard Ulysses

The scientific objectives of the Ulysses solar X-ray/cosmic gamma-ray burst experiment, and the unique features of the Ulysses mission which will help to achieve them are described. After a discussion of the special design constraints imposed by the mission, the sensor systems, consisting of two CsI scintillators and two Si surface barrier detectors covering the energy range 5-150 keV are described. Their operating modes and inflight performance are also given.

Hurley, K.↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

Fast neutrons (energies >0.5 MeV) contribute to the radiation exposure of space hardware and astronaut crew, enable greater understanding of planetary atmospheric and surface compositions and allow unique measurements of solar particle acceleration. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement. These measurements are challenging due to size constraints on satellites, particularly newer small satellites. The SOlar Neutron TRACking instrument (SONTRAC) is a small satellite neutron detector that utilizes fine-grained scintillating fiber bundles with 1-mm pitch silicon photomultiplier (SiPM) array readout. Signal processing is accomplished with multichannel ASICs. SONTRAC is able to image fast neutron (between 20-200 MeV) scatters in a compact scalable package. We discuss below the numerous applications of this technology and recent progress on the development and performance characteristics of the prototype instrument.

Georgia A de Nolfo↗

Telescope for x ray and gamma ray studies in astrophysics

Imaging of x-rays has been achieved by various methods in astrophysics, nuclear physics, medicine, and material science. A new method for imaging x-ray and gamma-ray sources avoids the limitations of previously used imaging devices. Images are formed in optical wavelengths by using mirrors or lenses to reflect and refract the incoming photons. High energy x-ray and gamma-ray photons cannot be reflected except at grazing angles and pass through lenses without being refracted. Therefore, different methods must be used to image x-ray and gamma-ray sources. Techniques using total absorption, or shadow casting, can provide images in x-rays and gamma-rays. This new method uses a coder made of a pair of Fresnel zone plates and a detector consisting of a matrix of CsI scintillators and photodiodes. The Fresnel zone plates produce Moire patterns when illuminated by an off-axis source. These Moire patterns are deconvolved using a stepped sine wave fitting or an inverse Fourier transform. This type of coder provides the capability of an instantaneous image with sub-arcminute resolution while using a detector with only a coarse position-sensitivity. A matrix of the CsI/photodiode detector elements provides the necessary coarse position-sensitivity. The CsI/photodiode detector also allows good energy resolution. This imaging system provides advantages over previously used imaging devices in both performance and efficiency.

Weaver, W. D.↗

Study of muons near shower cores at sea level using the E594 neutrino detector

The E594 neutrino detector has been used to study the lateral distribution of muons of energy 3 GeV near shower cores. The detector consists of a 340 ton fine grain calorimeter with 400,000 cells of flash chamber and dimensions of 3.7 m x 20 m x 3.7 m (height). The average density in the calorimeter is 1.4 gm/sq cm, and the average Z is 21. The detector was triggered by four 0.6 sq m scintillators placed immediately on the top of the calorimeter. The trigger required at least two of these four counters. The accompanying extensive air showers (EAS) was sampled by 14 scintillation counters located up to 15 m from the calorimeter. Several off line cuts have been applied to the data. Demanding five particles in at least two of the trigger detectors, a total of 20 particles in all of them together, and an arrival angle for the shower 450 deg reduced the data sample to 11053 events. Of these in 4869 cases, a computer algorithm found at least three muons in the calorimeter.

Goodman, J. A.↗