Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensible heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Thermal Energy Grid Storage (TEGS) Using Multi-Junction Photovoltaics (MPV) (Final Technical Report)

The project aimed to develop a thermal energy storage battery that converts electricity to heat and stores heat at ultra-high temperatures (>2000°C) in graphite blocks. The thermal battery discharge uses TPV cells that directly convert thermal energy to electrical energy without any moving parts. All components of this technology were successfully demonstrated at the laboratory scale in this project. Development of extremely low cost (< $20/kWh) grid level energy storage is a crucial necessity to reach high penetrations of renewables. The thermal battery technology developed in this project is expected to meet the cost targets that would enable full renewable penetration. The project focused on four key aspects of this technology: Converting electricity to ultra-high temperature heat: This was done through development of graphite Joule heaters. Major issues related to arcing, heater evaporation and deterioration due to long term oxidation were addressed to ensure lifetime exceeding the service lifetime of the battery. Converting ultra-high temperature heat back to electricity: This was done through development of beyond state-of-the-art TPV cells. We demonstrated energy conversion efficiency of >40% that is a world record and exceeds the average energy conversion efficiency of turbines in the USA. The findings are peer-reviewed and published in Nature, and received a wide media attention globally. Protecting the TPV cells to ensure lifetime: Deposition of volatilized material, such as sublimated material or particles, on the TPV cell could greatly reduce the efficiency and lifetime of the TPV cells by blocking their view to the heat source and causing cell overheating. In this project we developed and demonstrated an approach that reduces the deposition rate, ensuring long > 30 year life. Technoeconomic feasibility and commercialization: In collaboration with the project’s technical advisory board, we developed a technoeconomic model. The model shows that, at large scales (> 1GWh) the thermal battery technology is projected to reach a cost of energy stored below $10/kWh-e, with a cost per unit power < $0.5/W-e and a roundtrip efficiency of 50%. These results, along with the technical achievements in the project led to the creation of a startup company (i.e., Fourth Power) that is pursuing commercialization of the technology.

25 ENERGY STORAGE↗

Monthly averages of ED2 model simulations initialized with airborne lidar structure, Jan 1981-Dec 2018, Brazilian Amazon

Deforestation and forest degradation (selective logging, fires, fragmentation) have impacted nearly 40% of the original extent of the Brazilian Amazon, and have markedly impacted forest structure across the region. To date, few studies analysed how shifts in forest structure from degradation influence the forest sensitivity to climate extremes, because of the complex interactions between forest structure and micro-environmental conditions. To address this knowledge gap, we carried out a series of simulations across the Brazilian Amazon using the Ecosystem Demography Model (ED2), using observed forest structure derived from 541 airborne lidar transects (375 ha each) and two scenarios representing forest recovery and expansion of degradation to investigate how shifts in forest structure impact ecosystem function under near-average and extreme climate conditions, as part of the manuscript Longo et al 2025 "Degradation and Deforestation Increase the Sensitivity of the Amazon Forest to Climate Extremes". This dataset provides the output results from the ED2 model simulations for the three simulations at monthly time scales, in NetCDF format. For all simulations, we used bias-corrected hourly reanalyses (WFDE5) for most meteorological drivers, except for precipitation, which was obtained from CHIRPS. The meteorological drivers used in the study span 38 years (Jan 1981–Dec 2018). The output results correspond to the last 38 years of simulation (one full cycle of meteorological drivers), in which ED2 simulations used static stand structure (i.e., the forest structure was held constant). The following files are provided:ED2_emean_Global_R004_BrAmaz_s1c0t0l0f0.nc. This corresponds to the Control simulation. The forest structure was obtained from the airborne lidar.ED2_emean_Global_R005_BrAmaz_s1c0t1l1f0.nc. This corresponds to the Degraded simulation. The forest structure was obtained from a spin-up simulation initialized with airborne lidar and a scenario that expanded deforestation and selective logging across the Amazon.ED2_emean_Global_R006_BrAmaz_s1c0t1l0f0.nc. This corresponds to the Recovery simulation. The forest structure was obtained from a spin-up simulation initialized with airborne lidar and a scenario that completely halted deforestation and degradation, allowing degraded forests to recover for 38 years.We also provide file ED2_zones_R004_BrAmaz_s1c0t0l0f0.nc, which classifies each grid cell into zones used in the reference manuscript: 1: Southeast. 2: South. 3: West. 4: Central. 5: Northeast. 6: North. 7: Northwest". Index 0 corresponds to grid cells excluded from sub-region analyses because they were dominated by flooded forests, deforestation, and naturally non-forest vegetation.

54 ENVIRONMENTAL SCIENCES↗

Observations of surface energy fluxes and meteorology in the seasonally snow-covered high-elevation East River watershed during SPLASH, 2021–2023

Abstract. From autumn 2021 through summer 2023, scientists from the National Oceanic and Atmospheric Administration (NOAA) and partners conducted the Study of Precipitation, the Lower Atmosphere, and Surface for Hydrometeorology (SPLASH) campaign in the East River watershed of Colorado. One objective of SPLASH was to observe the transfer of energy between the atmosphere and the surface, which was done at several locations. Two remote sites were chosen that did not have access to power utilities. These were along the valley floor near the East River in the vicinity of the unincorporated town of Gothic, Colorado. Energy balance measurements were made at these locations using autonomous, single-level flux towers referred to as atmospheric surface flux stations (ASFSs). The ASFSs were deployed on 28 September 2021 at the Kettle Ponds Annex site and on 12 October 2021 at the Avery Picnic site and operated until 19 July and 21 June 2023, respectively. Measurements included basic meteorology; upward and downward longwave and shortwave radiative fluxes and subsurface conductive flux, each at 1 min resolution; 3-D winds from a sonic anemometer and H2O/CO2 from an open-path gas analyzer, both at 20 Hz from which sensible, latent heat, and CO2 fluxes were derived; and profiles of soil properties in the upper 0.5 m (both sites) and temperature profiles through the snow (at Avery Picnic), each reported between 10 min and 6 h. The system uptime was 97 % (Kettle Ponds) and 90 % (Avery Picnic), and collectively 1184 d of data was obtained between the stations. The purpose of this article is to document the ASFS deployment at SPLASH, to document the data acquisition and post-processing of measurements, and to serve as a guide for interested users of the data sets, which are archived at Zenodo (https://doi.org/10.5281/zenodo.10313363, Cox et al., 2023b; https://doi.org/10.5281/zenodo.10327409, Cox et al., 2023c; https://doi.org/10.5281/zenodo.10313894, Cox et al., 2023d; https://doi.org/10.5281/zenodo.10307825, Cox et al., 2023e; https://doi.org/10.5281/zenodo.10310520, Cox et al., 2023f) with the Creative Commons Attribution 4.0 International license.

Cox, Christopher J. (ORCID:0000000322037173)↗

Turbulent Parameters by airborne measurements over BNF in March 2025

The original data were collected during the AAF Engineering Flights (AEF2025) in the vicinity of the ARM Bankhead National Forest (BNF) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/bnf ) in northwestern Alabama in March 2025. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at the public-use airport of Posey Field, Alabama (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from March 10 through March 24, 2025. The ArcticShark UAS performed nine flights, including eight research flights over the AMF3 (BNF Main Site) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents a collection of turbulent parameters in the atmospheric boundary layer or lower free troposphere based on airborne measurement throughout the field campaign. The primary instruments used to create the current data set were the Aircraft Integrated Meteorological Measurement System (AIMMS-30) and the fine-wire thermocouple probe.

Atmosphere↗

CHELAX-BNF: Turbulent Parameters by airborne measurements

The original data were collected on board the ARM Aerial Facility ArcticShark uncrewed aerial system (UAS; https://www.arm.gov/capabilities/observatories/aaf/uas ) during the “Characterizing HEterogeneous Land-Atmosphere eXchanges at BNF” field campaign (CHEAX-BNF; https://arm.gov/research/campaigns/aaf2025CHELAX-BNF ). The ARM Aerial Facility ArcticShark UAS was based at the public-use airport of Posey Field, AL (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from May 28 through June 23, 2025. The ArcticShark UAS performed 5 flights, including 4 research flights over the BNF Main Site (ARM Mobile Facility 3, https://arm.gov/capabilities/observatories/amf ) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration, and aerosol size distribution. The current data set presents a collection of turbulent parameters in the atmospheric boundary layer or lower free troposphere based on airborne measurement throughout the field campaign. The primary instruments used to create the current data set were the Aircraft Integrated Meteorological Measurement System (AIMMS-30) and the fine-wire thermocouple probe.

Aircraft Integrated Meteorological Measurement Sys↗

Influence of Lake Ice Biases in Reanalysis Data on Downscaled Climate Simulations over the Great Lakes Region

This data package contains observation-based and model-simulated datasets (all provided in NetCDF format) for evaluating how wintertime lake-ice representation affects regional weather and climate over the Laurentian Great Lakes (freshwater lake ecosystem) during the high–ice-cover winter of 2009. The observational component includes: (1) Stage IV gridded precipitation at 4 km, hourly resolution for January–February 2009 over the Great Lakes region (radar–gauge multisensor precipitation analyses); (2) Great Lakes Surface Environmental Analysis (GLSEA) satellite-derived lake-ice coverage at 1.3 km, daily resolution for the 2009 winter months, providing ice coverage over Lakes Superior, Michigan, Huron, Erie, and Ontario; and (3) in situ measurements at the Standard Rock site on Lake Superior from the Great Lakes Evaporation Network (GLEN) at hourly resolution, including near-surface atmospheric variables and sensible and latent heat fluxes (air–lake exchange) at a fixed point location. The modeling component provides corresponding fields from two simulations, both archived at 4 km, hourly resolution: a standalone Weather Research Forecasting model (WRF) run driven by the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis 5 (ERA5), and a two-way coupled model using WRF and the Finite Volume Community Ocean Model (WRF-FVCOM, a 3-D hydrodynamic lake model). These outputs include variables relevant to air–lake interaction and lake-effect processes (e.g., near-surface temperature, humidity, wind, precipitation, and surface turbulent fluxes), enabling direct comparison with the observational datasets. Users can analyze and visualize these NetCDF files with common tools such as Python (e.g., xarray, netCDF4, numpy, pandas), NCO/CDO, Panoply, or ncview; NetCDF variables can also be converted to other formats (e.g., CSV, GeoTIFF) using these utilities.

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

ARM Data-Oriented Metrics and Diagnostics Package for Climate Model Evaluation

A Python-based metrics and diagnostics package is currently being developed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Infrastructure Team at Lawrence Livermore National Laboratory (LLNL) to facilitate the use of long-term, high-frequency measurements from the ARM Facility in evaluating the regional climate simulation of clouds, radiation, and precipitation. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The Coupled Model Intercomparison Project (CMIP) model data sets are also included in the package to enable model intercomparison as demonstrated in Zhang et al. (2017). The mean of the CMIP model can serve as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, and radiative fluxes, with plan to extend to more fields, such as aerosol and microphysics properties. Process-oriented diagnostics focusing on individual cloud- and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. The version 1.0 package is designed based on data collected at ARM’s Southern Great Plains (SGP) Research Facility, with the plan to extend to other ARM sites. The metrics and diagnostics package is currently built upon standard Python libraries and additional Python packages developed by DOE (such as CDMS and CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first present the input data, which constitutes the core content of the metrics and diagnostics package in section 2, and a user's guide documenting the workflow/structure of the version 1.0 codes, and including step-by-step instruction for running the package in section 3.

54 ENVIRONMENTAL SCIENCES↗

Thermocatalytic Heat Pipes for Geothermal Resource Recovery

Heat pipes are an important technology that allow orders of magnitude faster heat transfer than simple conduction. However, operating principles in heat pipes place fundamental bounds on their performance (critical heat flux and efficiency). Conventional heat pipe functionality is inherently tied to vaporization and condensation of the working fluid charged in the heat pipe. These fluids each have different operating temperature ranges based on the capillary, entrainment, sonic, and boiling limits of the heat pipe design. These limits, typically the capillary limit, dictate the maximum heat flux a heat pipe can carry, and most importantly for geothermal systems, the distance over which the pipes can operate (100 to 200 m maximum under optimum conditions). A thermocatalytic heat pipe breaks the inherent limitations of phase change thermo- and hydrodynamics and can transform heat pipe technology as a potentially more efficient means of extracting heat from a geothermal resource. The thermocatalytic heat pipe uses a working fluid to transport both sensible and chemical heat. An endothermic chemical reaction at depth removes heat from the reservoir and produces reactive intermediates, which are transported to the surface and used to run a reverse exothermic reaction that releases heat for use in power generation or other useful purposes. This technology offers two distinct advantages over conventional geothermal heat recovery technologies: (1) lower heat loss to the rock outside of the geothermal reservoir, and (2) higher heat transfer rates to the well field within the geothermal reservoir. Both advantages offer opportunity to reduce risks and lower costs of geothermal energy recovery. In this report, we discuss an initial effort to assess the efficacy and limitations of this technology for extracting heat from both porous/permeable and nominally impermeable geothermal reservoirs. Numerical simulation capabilities of the STOMP-GT code were enhanced to enable simulations of thermochemical heat pipes traversing geothermal reservoirs. An array of potential thermochemical reaction systems was evaluated and screened. Of these, an ethanol dehydration reaction was most promising in the vapor-liquid reaction set. A solid-phase dehydration reaction (CuSO4·5H2O) showed the highest reaction enthalpy per unit volume but would require development of a nonaqueous carrier fluid to implement it in a heat pipe. Subsurface reservoir simulations predicted long-term performance of the heat pipes for each geothermal reservoir type. The performance of U-shaped wells and coaxial wells was evaluated for a suite of reactions for both hydrothermal and hot dry rock reservoirs and was compared with a baseline case of simply pumping water through the wells. The heat pipe technology was additionally evaluated for an enhanced geothermal system (EGS) with an injection borehole, production borehole, and intervening hydraulically conductive fracture. All reservoir types showed significant improvement in heat recovered over a 20-year operating period ranging from a 1.8X increase for the hot dry rock case to more than 2.5X more energy recovered for the EGS case.

15 GEOTHERMAL ENERGY↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface Energy Balance System (SEBS) Instrument Handbook

A surface energy balance system (SEBS) has been installed collocated with each deployed eddy correlation flux measurement system (ECOR) after 2010 at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility Southern Great Plains (SGP) observatory, North Slope of Alaska (NSA) observatory, Eastern North Atlantic (ENA) observatory, and the first, second, and third ARM Mobile Facilities (AMF1, AMF2, AMF3). A SEBS was also deployed at the Tropical Western Pacific (TWP) site, before it was decommissioned. Data from these sites, including the retired TWP, are available in the ARM Data Center. The SEBS consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil temperature, soil moisture, and soil heat flow measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

54 ENVIRONMENTAL SCIENCES↗

The influence of surface heat fluxes on the growth of idealized monsoon depressions

This study explores the effect of surface sensible and latent heat fluxes on monsoon depressions using a series of idealized convection-permitting simulations. Each experiment is initialized with a small-amplitude wave that is allowed to grow within an environment representative of the South Asian monsoon. Comparing experiments with and without interactive surface heat fluxes, it is found that these fluxes enhance the growth of the simulated vortices. Without interactive surface fluxes, the strengthening period is short and the vortices fail to reach intensities characteristic of stronger monsoon depressions. Using a large set of experiments in which the vertical and meridional shear are systematically varied, it is found that surface heat fluxes enhance intensity the most when the upper-level shear is weak, the lower-level shear and associated moist static energy (MSE) gradient are sufficiently steep, and the lower-level meridional shear is strong. Here, these experiments reveal two different regimes of convection-coupled monsoon depression growth: one in which convection is driven by MSE advection and one in which it is driven by surface heat fluxes and quasigeostrophic forcing for ascent. Both regimes require sufficiently strong meridional shear to achieve initial growth by barotropic instability.

54 ENVIRONMENTAL SCIENCES↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Effectiveness of Advanced Three Fluid Heat and Mass Exchanger

Advanced internally-cooled membraned-based heat and mass exchangers (HMX), which accounts for three separate fluid streams, are capable of utilizing the sensible and latent heat removed from spacecooling to heat water. The technology provides a unique approach of enhancing the efficiency and cost effectiveness of future HVAC equipment. This paper aims to numerically identify and understand the impact of geometric size, operation conditions, and membrane properties on the overall effectiveness of three-fluid HMXs. The simulations are based on an ORNL in-house open-source HMX model which is capable of simulating such three-fluid HMX components for various flow patterns. The results are expected to enable detailed configuration evaluation and provide in-depth understanding of optimal three-fluid HMX performance at cost effectiveness.

Gao, Zhiming↗

Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces

Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical values for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Enlarged Nonclosure of Surface Energy Balance With Increasing Atmospheric Instabilities Linked to Changes in Coherent Structures

The nonclosure of surface energy balance remains an outstanding problem in eddy covariance (EC) measurements of land-surface fluxes of heat, water vapor, and CO 2 . Our data collected from an EC tower over a semiarid sagebrush ecosystem indicate that under unstable atmospheric conditions, the nonclosure becomes increased with increasing instability, consistent with many other studies. It is demonstrated that the increased nonclosure is not caused by the inadequate sampling of large-scale turbulent motions using a 30-min averaging interval, though the scales of turbulent motions dominating sensible and latent heat fluxes become enlarged with increasing instability. Quadrant analysis is then used to reveal that the flux contributions from ejections remain nearly constant with increasing instability, whereas the flux contributions from sweeps are reduced and their time fractions increase. Our results imply that the increased nonclosure of surface energy balance is associated with changes in turbulent structures including their dominant time scales and flux contributions of ejections and sweeps as the atmospheric instability increases, which require further studies using vertically distributed observations and/or large eddy simulations.

54 ENVIRONMENTAL SCIENCES↗

The influence of recent and future climate change on spring Arctic cyclones

In recent decades, the Arctic has experienced rapid atmospheric warming and sea ice loss, with an ice-free Arctic projected by the end of this century. Cyclones are synoptic weather events that transport heat and moisture into the Arctic, and have complex impacts on sea ice, and the local and global climate. However, the effect of a changing climate on Arctic cyclone behavior remains poorly understood. This study uses high resolution (4 km), regional modeling techniques and downscaled global climate reconstructions and projections to examine how recent and future climatic changes alter cyclone behavior. Results suggest that recent climate change has not yet had an appreciable effect on Arctic cyclone characteristics. However, future sea ice loss and increasing surface temperatures drive large increases in the near-surface temperature gradient, sensible and latent heat fluxes, and convection during cyclones. The future climate can alter cyclone trajectories and increase and prolong intensity with greatly augmented wind speeds, temperatures, and precipitation. Such changes in cyclone characteristics could exacerbate sea ice loss and Arctic warming through positive feedbacks. The increasing extreme nature of these weather events has implications for local ecosystems, communities, and socio-economic activities.

54 ENVIRONMENTAL SCIENCES↗