Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Improved Performance of Zinc Oxide Thin Film Transistor Pressure Sensors and a Demonstration of a Commercial Chip Compatibility with the New Force Sensing Technology

Abstract A zinc oxide thin film transistor is developed and optimized that simultaneously functions as a transistor and a force sensor, thus allowing for scalable integration of sensors into arrays without the need for additional addressing elements. Through systematic material deposition, microscopy, and piezoelectric characterization, it is determined that an O 2 rich deposition condition improves the transistor performance and pressure sensing characteristics. With these optimizations, a sensitivity of 4 nA kPa −1 and a latency of below 1 ms are achieved, exceeding the criteria for successful commercialization of arrayed pressure sensors. The functionality of 16 × 16 pressure sensor arrays on thin bendable glass substrates for integrated low weight and flexible touchscreen displays is fabricated and demonstrated and read‐out electronics to interface with the arrays and to record their response in real‐time are developed. Finally, the application of these sensors for mobile displays via their operation with an existing commercial touch integrated circuit controller is demonstrated.

Vishniakou, Siarhei↗

Ultra-compact hybrid silicon:chalcogenide waveguide temperature sensor

We demonstrate a real-time, reusable, and reversible integrated optical sensor for temperature monitoring within harsh environments. The sensor architecture combines the phase change property of chalcogenide glasses (ChG) with the high-density integration advantages of high index silicon waveguides. To demonstrate sensor feasibility, ChG composition Ge 40 S 60 , which is characterized by a sharp phase transition from amorphous to crystalline phase around 415 °C, is deposited over a 50 µ m section of a single mode optical waveguide. The phase transition changes the behavior of Ge 40 S 60 from a low loss to high loss material, thus significantly affecting the hybrid waveguide loss around the phase transition temperature. A transmission power drop of over 40dB in the crystalline phase compared to the amorphous phase is experimentally measured. Moreover, we recover the amorphous phase through the application of an electrical pulse, thus showing the reversible nature of our compact temperature sensor. Through integrating multiple compositions of ChG with well-defined phases transition temperatures over a silicon waveguide array, it is possible to determine, in real-time, the temperature evolution within a harsh environment, such as within a nuclear reactor cladding.

Badamchi, Bahareh (ORCID:0000000193105300)↗

Thin Film Hydrogen Sensor Development, Testing and Integration Into Low Cost Wireless Sensing Systems (SBIR Phase 1 Final Report)

Element One, Inc. is reporting on the results of its DOE SBIR Phase I project for the development and testing of low-cost thin film hydrogen sensors and their subsequent integration into wireless sensing systems and networks. This work is based on Element One’s chemo-chromic sensing technology which indicates hydrogen presence (leaks) colorimetrically and electronically with no power required. The lack of required power makes them particularly suitable for passive Radio Frequency Identification Device (RFID) technology which can be deployed affordably and abundantly to detect leaks in hazardous environments. Element One built upon its experience with chemochromic materials that change color in the presence of hydrogen. Both thin films and pigments have been used, but thin films have the ability to change conductivity by more than three orders of magnitude making them ideal for resistive sensors. Prototype sensors were fabricated, tested and characterized. For the wireless component, Element One partnered with Esensor, Inc. to construct and test a wireless sensing network. The network was tested and validated at the National Renewable Energy Laboratory (NREL) in February and March. The tests involved exposing the wireless system to hydrogen gas concentrations of 1% and 5%. There were no significant problems encountered, and the system is ready for commercial development. The system demonstrated the viability of wireless hydrogen sensing networks for hydrogen leak detection and other applications.

08 HYDROGEN↗

Direct-Write Printed Current Sensor for Load Monitoring Applications

We report on a flexible current sensor development employing direct-write printing and additive manufacturing techniques. The integrated current sensor unit incorporates sensing, data processing & storage, and in-field calibration capabilities. A combination of direct-write printing technique and low-temperature curable metallic ink is used to print Ag wires around a 12.5-μm -thick permalloy film. The overall thickness of the polyimide substrate and permalloy sheet remains well-below 500 μm enabling wrap-around sensor functionality. Fused deposition modeling (FDM) additive manufacturing is used to build custom parts for sensor mounting, encapsulation, and an in-field calibration unit using heat and chemical-resistant thermoplastic which responds well to mechanical stress. In the present configuration, the integrated current sensor unit can be powered through USB or 4 AAA batteries to allow data collection and sensor calibration in the field. The flexible current sensor employing a continuous sheet of the permalloy exhibited a well-behaved signal output response at peak current levels exceeding 15A and in the applied ac frequency range of 60 Hz–10 kHz. Overall, the combination of direct-write printing, thin permalloy material, and additive manufacturing technique shows promise for the development of a reconfigurable low-cost current sensor that can be deployed in large numbers at locations of interest to avail the cost and energy-saving opportunities in industrial/commercial and residential applications.

Yu, Yongchao↗

A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration

Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. In this paper, we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na + sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na + concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.

47 OTHER INSTRUMENTATION↗

Fabrication and characterization of an undoped GaAs/AlGaAs quantum dot device

We demonstrate the development of a double quantum dot with an integrated charge sensor fabricated in undoped GaAs/AlGaAs heterostructures using a double top-gated design. Based on the evaluation of the integrated charge sensor, the double quantum dot can be tuned to a few-electron region. Additionally, the inter-dot coupling of the double quantum dot can be tuned to a large extent according to the voltage on the middle gate. The quantum dot is shown to be tunable from a single dot to a well-isolated double dot. To assess the stability of such design, the potential fluctuation induced by 1/f noise was measured. Based on the findings herein, the quantum dot design developed in the undoped GaAs/AlGaAs semiconductor shows potential for the future exploitation of nano-devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sensor impact evaluation and verification for fault detection and diagnostics in building energy systems: A review

Sensors are the key information source for fault detection and diagnostics (FDD) in buildings. However, sensors are often not properly designed, installed, calibrated, located, and maintained, which negatively impacts FDD performance. Several sensor-related FDD topics have been widely studied, covering a wide range of fault types and applications. However, it is difficult to get a clear picture of the technical development of sensor-related topics in FDD. A systematic review of sensor topics is needed to summarize the existing research in a logical way, draw conclusions on the current development, and predict the future development of sensors in building FDD. To address this gap, we conducted a comprehensive literature review of more than 100 FDD-sensor-related papers. In this article, we subdivide the FDD tasks into building-level, system-level, and component-level FDD, and review sensor-related topics in each category. Our major conclusions are: (a) current data-driven FDD research focuses more on FDD algorithms than sensors, (b) sensor “hardware” research topics are less studied than sensor “software” topics, (c) very few papers focus on sensor engineering as an integral aspect of FDD development, and (d) some important sensor topics, such as sensor cost-effectiveness and sensor schema/layout/location, are not well studied. Finally, we discuss the need for a systematic framework of FDD sensors and models to integrate sensor design/selection, sensor data analysis/mining, feature selection, physics-based or data-driven algorithm development, sensor fault detection, sensor calibration, and sensor maintenance. Finally, expert interviews are conducted to validate the above findings and conclusions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes in situ polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

61 RADIATION PROTECTION AND DOSIMETRY↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and fabrication of a differential scanning nanocalorimeter

This paper describes the design, fabrication, and characterization of a differential scanning nanocalorimeter that significantly reduces the sample volume to microliters and can potentially improve the temperature sensitivity to 10 µK. The nanocalorimeter consists of a polymeric freestanding membrane, four high-sensitive low-noise thermistors based on silicon carbide (SiC), and a platinum heater and temperature sensor. With the integrated heater and sensors, temperature scanning and power compensation can be achieved for calorimetric measurement. Temperature sensing SiC film was prepared by using sintered SiC target and DC magnetron sputtering under different gas pressures and sputtering power. The SiC sensing material is characterized through the measurement of current–voltage curves and noise levels. The thermal performance of a fabricated nanocalorimeter is studied in simulation and experiment. The experiment results show the device has excellent thermal isolation to hold thermal energy. As a result, the noise test together with the simulation show the device is promising for micro 10 µK temperature sensitivity and nanowatt resolution which will lead to low-volume ultra-sensitive nanocalorimetry for biological processes, such as protein folding and ligand binding.

42 ENGINEERING↗

A wearable patch for continuous analysis of thermoregulatory sweat at rest

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl - , and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson’s disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.

47 OTHER INSTRUMENTATION↗

High-speed imaging at high x-ray energy: CdTe sensors coupled to charge-integrating pixel array detectors

Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we describe the hybridization of CdTe sensors to two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD (MM-PAD), both developed previously in our laboratory. The charge-integrating architecture of each of these PADs extends the instantaneous counting rate by many orders of magnitude beyond that obtainable with photon counting architectures. The Keck PAD chip consists of rapid, 8-frame, in-pixel storage elements with framing periods <150 ns. The second detector, the MM-PAD, has an extended dynamic range by utilizing an in-pixel overflow counter coupled with charge removal circuitry activated at each overflow. This allows the recording of signals from the single-photon level to tens of millions of x-rays/pixel/frame while framing at 1 kHz. Both detector chips consist of a 128×128 pixel array with (150 µm){sup 2} pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust and compact entanglement generation from diode-laser-pumped four-wave mixing

Four-wave-mixing processes are now routinely used to demonstrate multi-spatial-mode Einstein-Podolsky-Rosen entanglement and intensity difference squeezing. Diode-laser-pumped four-wave mixing processes have recently been shown to provide an affordable, compact, and stable source for intensity difference squeezing, but it was unknown if excess phase noise present in power amplifier pump configurations would be an impediment to achieving quadrature entanglement. Here, we demonstrate the operating regimes under which these systems are capable of producing entanglement and under which excess phase noise produced by the amplifier contaminates the output state. We show that Einstein-Podolsky-Rosen entanglement in two mode squeezed states can be generated by a four-wave-mixing source deriving both the pump field and the local oscillators from a tapered-amplifier diode-laser. This robust continuous variable entanglement source is highly scalable and amenable to miniaturization, making it a critical step toward the development of integrated quantum sensors and scalable quantum information processors, such as spatial comb cluster states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy-Harvesting Based Wireless Sensor Using LoRa Protocol

This software can be applied with an integrated wireless sensor node that can sense environmental variables, process the variables, and transmit using the LoRa protocol. The software accompanies an embedded circuit layout that has sensing, processing, and communication circuitry. The software effectively retrieves data from a sensor node, processes them and transmits over the air while conserving on board energy.

Kuruganti, Phani Teja V↗